Medical image registration
The DOI matches its Crossref record; 123 of the 123 references it cites were found in a registry or an index.
Abstract
Radiological images are increasingly being used in healthcare and medical research. There is, consequently, widespread interest in accurately relating information in the different images for diagnosis, treatment and basic science. This article reviews registration techniques used to solve this problem, and describes the wide variety of applications to which these techniques are applied. Applications of image registration include combining images of the same subject from different modalities, aligning temporal sequences of images to compensate for motion of the subject between scans, image guidance during interventions and aligning images from multiple subjects in cohort studies. Current registration algorithms can, in many cases, automatically register images that are related by a rigid body transformation (i.e. where tissue deformation can be ignored). There has also been substantial progress in non-rigid registration algorithms that can compensate for tissue deformation, or align images from different subjects. Nevertheless many registration problems remain unsolved, and this is likely to continue to be an active field of research in the future.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“General approaches address multimodal image registration by either performing image synthesis [22, 23] to change the problem to a uni-modal image registration task, or by proposing complex, hand-crafted [24, 25, 26, 27] or learned [28, 29, 30, 31, 32] multi-modal image similarity measures.”
From Quicksilver: Fast predictive image registration – A deep learning approach (2017) · cites this paper as [29]
Citations
Cites
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
A method for registration of 3-D shapes
Besl, P. J., & McKay, N. D. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121791 · Cited by 18,103
Co-Planar Stereotaxic Atlas of the Human Brain
Talairach, J., & Tournoux, P. (1988) · Medical Entomology and Zoology · Cited by 11,798
Communication in the presence of noise
Shannon, C. E. (1949) · Proceedings of the IRE · doi:10.1109/jrproc.1949.232969 · Cited by 6,539
Golub, G. H., & Loan, C. F. V. (1996) · Johns Hopkins University Press eBooks · Cited by 6,027
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Self-citationPrincipal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
Communication In The Presence Of Noise
Shannon, C. E. (1998) · Proceedings of the IEEE · doi:10.1109/jproc.1998.659497 · Cited by 4,804
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Research works printed but not linked: 7
- 10.1016/S1361-8415(96)80006-5 · doi:10.1016/s1361-8415(96)80006-5
- 10.1002/(SICI)1522-712X(1995)1:4<198::AID-IGS2>3.0.CO;2-5 · doi:10.1002/(sici)1522-712x(1995)1:4<198::aid-igs2>3.0.co;2-5
- 10.1002/(SICI)1522-2594(200004)43:4<583::AID-MRM13>3.0.CO;2-B · doi:10.1002/(sici)1522-2594(200004)43:4<583::aid-mrm13>3.0.co;2-b
- Press W H, 1992
- Sibson R, 1978, J. R. Statist. Soc., 40, 234
- 10.1002/(SICI)1522-2586(199910)10:4<582::AID-JMRI12>3.0.CO;2-X · doi:10.1002/(sici)1522-2586(199910)10:4<582::aid-jmri12>3.0.co;2-x
- 10.1016/S1361-8415(96)80004-1 · doi:10.1016/s1361-8415(96)80004-1
Cited by
Items 701–800 of 1,032
eHUGS: Enhanced Hierarchical Unbiased Graph Shrinkage for Efficient Groupwise Registration
Guorong Wu, A., Peng, X., Ying, S., Wang, Q., Yap, P., Shen, D., & Shen, D. (2016) · PLoS ONE · doi:10.1371/journal.pone.0146870 · Cited by 6
3D nonrigid medical image registration using a new information theoretic measure
Li, B., Yang, G., Coatrieux, J.-L., Li, B., & Shu, H. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/22/8767 · Cited by 7
“It plays a major role in medicine for multimodal diagnosis and computer-aided surgery (Maintz et al 1998, Hill et al 2001).”
BackgroundDeformable Image Registration and Intensity Correction of Cardiac Perfusion MRI
Ebrahimi, M., & Kulaseharan, S. (2014) · International Workshop on Statistical Atlases and Computational Models of the Heart · doi:10.1007/978-3-319-14678-2_2 · Cited by 7
Analysis of linear filtering techniques on X-Ray image
Agarwal, S., Joshi, Y., Singh, D., & Nagaria, D. (2014) · International Conference on Computer and Communication Technology · doi:10.1109/iccct.2014.7001511 · Cited by 6
Effects of rigid, affine, b-splines and demons registration on video content: A review
Chakraborty, S., Nath, S., Acharjee, S., Dey, N., & Roy, S. (2014) · International Conference on Control, Instrumentation, Communication and Computational Technologies · doi:10.1109/iccicct.2014.6993013 · Cited by 7
Bonarrigo, F., & Signoroni, A. (2014) · Image and Vision Computing · doi:10.1016/j.imavis.2014.02.012 · Cited by 5
Preliminary results in large bone segmentation from 3D freehand ultrasound
Fanti, Z., Torres, F., & Cosío, F. A. (2013) · Other Conferences · doi:10.1117/12.2041809 · Cited by 7
“Some approaches to made registration between images are well described in literature.(7,8) Commercial CAOS systems with images based registration, used intraoperative images from CT, MRI or fluoroscopy(9) and it has been reported that the use of imaging approach to make the registration has less error that those who u…”
BackgroundAnalysis of Compactly Supported Transformations for Landmark-based Image Registration
Cavoretto, R., & Rossi, A. D. (2013) · doi:10.12785/amis/070602 · Cited by 7
“[8, 9, 12–14, 17–19, 22, 23, 26] and references therein.”
Image registration and atlas-based segmentation of cardiac outflow velocity profiles
Kalinić, H., Lončarić, S., Čikeš, M., Miličić, D., & Bijnens, B. (2012) · Comput. Methods Programs Biomed. · doi:10.1016/j.cmpb.2010.11.001 · Cited by 7
Composite radiation dose representation using Fuzzy Set theory
Park, S., Monroe, J., Yao, M., Machtay, M., & Sohn, J. (2012) · Information Sciences · doi:10.1016/j.ins.2011.10.025 · Cited by 7
Leung, L. H. T., Wong, W., Cheng, A. C. K., Kan, M. W. K., Cheung, J. Y. C., Lam, N., Yuen, K., & Yau, C. C. (2010) · Medical dosimetry · doi:10.1016/j.meddos.2010.02.005 · Cited by 4
Accurate Image Registration Using SIFT for Extended-Field-of-View Sonography
Kong, L., Huang, Q., Lu, M.-H., Zheng, S., Jin, L., & Chen, S. (2010) · International Conferences on Biomedical and Bioinformatics Engineering · doi:10.1109/icbbe.2010.5517503 · Cited by 7
An Improved Medical Image Registration Framework Based on Mutual Information
Yang, A., Lin, C.-X., Wang, C., & Li, H.-Q. (2009) · Global Congress on Intelligent Systems · doi:10.1109/gcis.2009.32 · Cited by 7
“This flexibility makes MI well suited as a criterion of multi-modality registration [7] [8].”
BackgroundBansal, R., Staib, L. H., Laine, A. F., Xu, D., Liu, J., Posecion, L. F., & Peterson, B. S. (2008) · Medical Image Analysis · doi:10.1016/j.media.2008.09.002 · Cited by 8
“registration have been proposed (Brown, 1992; Viola and Wells, 1997; Lester and Arridge, 1999; Hanjal et al., 2001; West et al., 1996).”
BackgroundNonlinear registration using variational principle for mutual information
Zhilkin, P., Alexander, M., & Sun, J.-K. (2008) · Pattern Recognition · doi:10.1016/j.patcog.2008.02.001 · Cited by 7
Stochastic optimization approach for entropic image alignment
Mohamed, W., Zhang, Y., Hamza, A. B., & Bouguila, N. (2008) · 2008 IEEE International Symposium on Information Theory · doi:10.1109/isit.2008.4595365 · Cited by 7
Tanaka, R., Sanada, S., Matsui, T., Hayashi, N., & Matsui, O. (2008) · Radiological Physics and Technology · doi:10.1007/s12194-008-0021-6 · Cited by 7
Adaptive non-rigid registration of 3D knee MRI in different pose spaces
Rhee, T., Lewis, J. P., Nayak, K., & Neumann, U. (2008) · IEEE International Symposium on Biomedical Imaging · doi:10.1109/isbi.2008.4541195 · Cited by 7
Computer-generated fMRI phantoms with motion–distortion interaction
Xu, N., Fitzpatrick, J. M., Li, Y., Dawant, B. M., Pickens, D. R., & Morgan, V. L. (2007) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.03.032 · Cited by 8
Modeling Aceto-White Temporal Patterns to Segment Colposcopic Images
Acosta-Mesa, H.-G., Cruz-Ramírez, N., Hernández-Jiménez, R., & García-López, D.-A. (2007) · Iberian Conference on Pattern Recognition and Image Analysis · doi:10.1007/978-3-540-72849-8_69 · Cited by 7
“Medical registration methods are covered in more detail for example in [13].”
MethodMultimodality imaging combination in small animal via point-based registration
Yang, C.-C., Wu, T.-H., Lin, M., Huang, Y.-H., Guo, W.-Y., Chen, C.-L., Wang, T.-C., Yin, W.-H., & Lee, J. S. (2006) · doi:10.1016/j.nima.2006.08.045 · Cited by 7
Dominich, S., Góth, J., & Kiezer, T. (2006) · Comput. Medical Imaging Graph. · doi:10.1016/j.compmedimag.2006.04.001 · Cited by 7
“[7] Hajnal J, Hawkes DJ, Hill D.”
Elasto-mammography: Theory, Algorithm, and Phantom Study
Wang, Z.-G., Liu, Y., Sun, L., Wang, G., & Fajardo, L. (2006) · International Journal of Biomedical Imaging · doi:10.1155/ijbi/2006/53050 · Cited by 7
The Role of Non-Overlap in Image Registration
August, J., & Kanade, T. (2005) · Information Processing in Medical Imaging · doi:10.1007/11505730_59 · Cited by 7
Rajasekar, D., Datta, N., Gupta, R. K., & Rao, S. B. (2004) · Medical Dosimetry · doi:10.1016/j.meddos.2004.04.002 · Cited by 7
Multi-Modal Medical Image Integration to Optimize Radiotherapy Planning in Lung Cancer Treatment
Rizzo, G., Cattaneo, G., Castellone, P., Castiglioni, I., Ceresoli, G., Messa, C., Landoni, C., Gilardi, M., Arienti, R., Cerutti, S., et al. (2004) · Annals of Biomedical Engineering · doi:10.1114/b:abme.0000042227.37183.1c · Cited by 7
Evaluation of nine similarity measures used in rigid registration
Skerl, D., Likar, B., & Pernus, F. (2004) · Proceedings of the 17th International Conference on Pattern Recognition, 2004. ICPR 2004. · doi:10.1109/icpr.2004.1334648 · Cited by 7
“The study of normal and pathological states, diagnosis, and therapy planning, execution, and evaluation can be improved by the integration of complementary information from images acquired by different modalities, like CT, MRI, PET, or US [1, 2].”
BackgroundOatridge, A., Hajnal, J., Saeed, N., Newlands, E., Curati, W., White, S., Puri, B. K., & Bydder, G. (2002) · Clinical Radiology · doi:10.1053/crad.2002.1103 · Cited by 7
Medical Imaging for Three-Dimensional Computer-Aided Models
Amorim, P. H. J., de Moraes, T. F., Rezende, R. A., da Silva, J. V. L., & Pedrini, H. (2018) · Springer eBooks · doi:10.1007/978-3-319-45444-3_6 · Cited by 6
PET Physics and Instrumentation
Krishnamoorthy, S., Schmall, J. P., & Surti, S. (2016) · Springer eBooks · doi:10.1007/978-3-319-40070-9_8 · Cited by 10
Role of Computers and Image Processing in Image-Guided Brain Tumor Surgery
Farhat, N., Kapur, T., & Kikinis, R. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-800870-6.00006-6 · Cited by 4
Deformable multi-modal image registration by maximizing Rényi's statistical dependence measure
Chen, Y., Shi, J.-L., Rao, M., & Lee, J. (2015) · Inverse Problems and Imaging · doi:10.3934/ipi.2015.9.79 · Cited by 7
Parallel Implementation of Total-FETI DDM with Application to Medical Image Registration
Merta, M., Vasatová, A., Hapla, V., & Hořák, D. (2014) · doi:10.1007/978-3-319-05789-7_89 · Cited by 7
“For more examples of usage of medical image registration see [8].”
BackgroundMotion Complexity Analysis with Automated Lung Field Tracking in MRI Temporal Sequences
Gotoh, T., Hosoda, Y., Yanagita, T., Kagei, S., Iwasawa, T., Inoue, T., & Tsuzuki, M. D. S. G. (2011) · doi:10.3182/20110828-6-it-1002.01653 · Cited by 7
“The first step creates an initial registration scheme based on the pattern matching (Hill et al., 2001), and the second step uses some robust constraints to avoid mistracking.”
BackgroundMultimodality Image Registration Using Spatial Procrustes Analysis and Modified Conditional Entropy
Cho, W., Kim, S., Lee, M., Kim, S.-H., Park, S., & Jeong, C.-B. (2008) · Journal of Signal Processing Systems · doi:10.1007/s11265-008-0203-9 · Cited by 8
Multi-modal non-rigid registration of volumetric medical images
Andronache, A. (2006) · doi:10.3929/ethz-a-005266962 · Cited by 7
“For more details, the reader should refer to [Hajnal et al. 2001] and the references therein.”
BackgroundMethodInfluentialDeng, L., Lan, Q., Yang, X. N., Wang, J., & Huang, S. (2024) · Abdominal Radiology · doi:10.1007/s00261-024-04602-3 · Cited by 7
Do Pulmonary Cavity Shapes Influence Lung Function?
Minaeizaeim, H., Kumar, H., Tawhai, M. H., King, C., Hoffman, E. A., WILSHER, M. L., Milne, D. G., & Clark, A. R. (2019) · Journal of Biomechanical Engineering · doi:10.1115/1.4044092 · Cited by 8
Goetz, J., Fieguth, P., Kasiri, K., Bodin, X., Marcer, M., & Brenning, A. (2019) · Remote Sensing of Environment · doi:10.1016/j.rse.2019.111275 · Cited by 6
Non-linear Approach for MRI to intra-operative US Registration Using Structural Skeleton
Hong, J., & Park, H. (2018) · Lecture notes in computer science · doi:10.1007/978-3-030-01045-4_16 · Cited by 7
Sugawara, Y., Tachibana, H., Kadoya, N., Kitamura, N., Sawant, A., & Jingu, K. (2017) · Medical Dosimetry · doi:10.1016/j.meddos.2017.07.004 · Cited by 6
Fast computation of residual complexity image similarity metric using low‐complexity transforms
Pauchard, Y., Cintra, R. J., Madanayake, A., & Bayer, F. M. (2015) · IET Image Processing · doi:10.1049/iet-ipr.2014.0939 · Cited by 6
A Review of Ultrasound and Computed Tomography Registration Approaches
Mazaheri, S., Sulaiman, P. S., Rahmat, R. W. O. K., Dimon, M. Z., Khalid, F., & Tayebi, R. M. (2014) · International Conference on Computer Assisted System in Health (CASH) · doi:10.1109/cash.2014.17 · Cited by 6
Automatic co-registration of satellite imagery and LiDAR data using local Mutual Information
Parmehr, E. G., Fraser, C., Zhang, C.-S., & Leach, J. (2013) · IEEE International Geoscience and Remote Sensing Symposium · doi:10.1109/igarss.2013.6721356 · Cited by 6
“MI has been used as a similarity measure for multisensor data registration in medical imaging for some two decades [8].”
BackgroundMethodJoint Learning of Appearance and Transformation for Predicting Brain MR Image Registration
Wang, Q., Kim, M., Guorong Wu, A., & Shen, D. G. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-38868-2_42 · Cited by 6
Automatic Registration of Aerial Images with 3D LiDAR Data Using a Hybrid Intensity-Based Method
Parmehr, E. G., Fraser, C., Zhang, C.-S., & Leach, J. (2012) · International Conference on Digital Image Computing: Techniques and Applications · doi:10.1109/dicta.2012.6411697 · Cited by 6
Constrained 2-D/3-D Registration for Motion Compensation in AFib Ablation Procedures
Brost, A., Wimmer, A., Liao, R., Hornegger, J., & Strobel, N. (2011) · International Conference on Information Processing in Computer-Assisted Interventions · doi:10.1007/978-3-642-21504-9_13 · Cited by 6
Deformation models for registering MR and 3D ultrasound breast images
Tanner, C., Karssemeijer, N., & Székely, G. (2011) · IEEE International Symposium on Biomedical Imaging · doi:10.1109/isbi.2011.5872474 · Cited by 6
“The main components of a feature-based image registration are the transformation model, the feature extraction and correlation, and the optimization strategy [3].”
MethodHoegele, W., Loeschel, R., Dobler, B., Hesser, J., Koelbl, O., & Zygmanski, P. (2011) · Medical Physics · doi:10.1118/1.3532959 · Cited by 6
Fast free-form registration based on Kullback-Leibler distance for multimodal medical image
Al-Azzawi, N. A., Sakim, H. A. M., & Abdullah, W. A. K. W. (2010) · IEEE Symposium on Industrial Electronics & Applications (ISIEA) · doi:10.1109/isiea.2010.5679413 · Cited by 5
A Learning-Based Approach to Evaluate Registration Success
Vetter, C., Kamen, A., Khurd, P., & Westermann, R. (2010) · Medical Imaging and Augmented Reality · doi:10.1007/978-3-642-15699-1_45 · Cited by 6
Park, H., Hero, A., Bland, P. H., Kessler, M., Seo, J., & Meyer, C. (2010) · IEICE Trans. Inf. Syst. · doi:10.1587/transinf.e93.d.2291 · Cited by 6
“Registration has been well reviewed in Hill’s paper [24].”
BackgroundOptimal discrete multi-resolution deformable image registration
van Stralen, M., & Pluim, J. P. W. (2009) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2009.5193210 · Cited by 4
“We target image registration problems in biomedical applications [1].”
BackgroundMass preserving registration for lung CT
Gorbunova, V., Lo, P., Loeve, M., Tiddens, H., Sporring, J., Nielsen, M., & de Bruijne, M. (2009) · Medical Imaging · doi:10.1117/12.812504 · Cited by 6
Follow-up segmentation of lung tumors in PET and CT data
Opfer, R., Kabus, S., Schneider, T., Carlsen, I., Renisch, S., & Sabczynski, J. (2009) · Medical Imaging · doi:10.1117/12.811599 · Cited by 6
Donizete, R., de Pádua, S. D., de Oliveira, L. F., Georges, J.-J., de Groote, S., Ana, L. W., & Simões, M. (2008) · doi:10.1590/s0100-39842008000600010 · Cited by 6
“So, the image registration algorithm will generate parameters for spatial transformation of images performing several interactions until the C value achieves the nearest possible to 1((9)).”
MethodQuaia, E., Krug, L. M., Pandit-Taskar, N. D., Nagel, A., Reuter, V. E., Humm, J. L., & Divgi, C. R. (2007) · European Journal of Radiology · doi:10.1016/j.ejrad.2007.07.004 · Cited by 7
Rigid Image Registration based on Pixel Grouping
Gerogiannis, D., Nikou, C., & Likas, A. (2007) · International Conference on Image Analysis and Processing · doi:10.1109/iciap.2007.111 · Cited by 6
“Medical imaging, with its wide variety of sensors (MRI, nuclear, ultrasonic, X-Ray) is probably one of the first application fields [14, 7].”
BackgroundImproved elastic medical image registration using mutual information
Ens, K., Schumacher, H., Franz, A., & Fischer, B. (2007) · SPIE Medical Imaging · doi:10.1117/12.707632 · Cited by 6
Registration of DCE MR Images for Computer-Aided Diagnosis of Breast Cancer
Wu, Q., Whitman, G., Fussell, D., & Markey, M. (2006) · 2006 Fortieth Asilomar Conference on Signals, Systems and Computers · doi:10.1109/acssc.2006.354865 · Cited by 6
“Registration is an essential tool in medical imaging [6]-[7].”
MethodPerformance Study of Nonrigid Registration Algorithm for Investigating Lung Disease on Clusters
Ino, F., Tanaka, Y., Hagihara, K., & Kitaoka, H. (2005) · International Conference on Parallel and Distributed Computing: Applications and Technologies · doi:10.1109/pdcat.2005.188 · Cited by 6
“Image registration [1] is a technique for establishing point-to-point correspondences between different images taken at different time, from different viewing points, in different modalities.”
BackgroundRohlfing, T., Schaupp, F., Haddad, D., Brandt, R., Haase, A., Menzel, R., & Maurer, C. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1896025 · Cited by 6
Fast intensity-based fluoroscopy-to-CT registration using pattern search optimization
Roth, M., Dötter, M., Burgkart, R., & Schweikard, A. (2004) · International Congress Series · doi:10.1016/j.ics.2004.03.260 · Cited by 5
Zamburlini, M., Camborde, M.-L., de la Fuente‐Fernández, R., Stoessl, A. J., Ruth, T. J., & Sossi, V. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.823030 · Cited by 6
“In particular, it uses a first order Taylor series to approximate the effect of the transformation [7].”
MethodNon-rigid Registration of Vessel Structures in IVUS Images
Amores, J., & Radeva, P. (2003) · Iberian Conference on Pattern Recognition and Image Analysis · doi:10.1007/978-3-540-44871-6_6 · Cited by 6
A high-performance computing service over the Internet for nonrigid image registration
Ino, F., Ooyama, K., Kawasaki, Y., Takeuchi, A., Mizutani, Y., Masumoto, J., Sato, Y., Sugano, N., Nishii, T., Miki, H., et al. (2003) · Computer Assisted Radiology and Surgery - International Congress and Exhibition · doi:10.1016/s0531-5131(03)00337-6 · Cited by 6
Wachowiak, M. P., Smolikova, R., Żurada, J. M., & Elmaghraby, A. S. (2003) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2002.1007761 · Cited by 7
“For this approach, linear combinations of polynomials, basis functions, B-spline and Bézier-spline techniques have been reported [4-5].”
MethodSegmentation of Shoulder MRI Data for Musculoskeletal Model Adaptation
Ryba, T., & Krňoul, Z. (2019) · Bioimaging (Bristol. Print) · doi:10.5220/0007580701550160 · Cited by 6
“As another form of segmentation, the image registration can be considered (Hajnal and Hill, 2001).”
BackgroundImage and surface registration
Chen, K., Lui, L. M., & Modersitzki, J. (2019) · Handbook of numerical analysis · doi:10.1016/bs.hna.2019.07.001 · Cited by 14
Deformable regions of interest with multiple points for tissue tracking in echocardiography
Cui, X., Washio, T., Chono, T., Baba, H., Okada, J., Sugiura, S., & Hisada, T. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.08.002 · Cited by 7
“…registration methods have been divided into a “rigid” regstration method (only rotation and translation are considered) Maintz and Viergever, 1998; Hill et al., 2001 ) and a “non-rigid” egistration method (besides the rotation and translation, defor- ation is also considered) ( Zitová and…”
Medical Image Processing and Analysis
Tian, J., Wang, Y., Dai, X., & Zhang, X. (2013) · Advanced topics in science and technology in China · doi:10.1007/978-3-642-34303-2_11 · Cited by 59
Mechanical and optical methods for breast cancer imaging
Wang, Z. (2010) · doi:10.17077/etd.tkw7yxhj · Cited by 7
“However, pinpoint tracking of large number of material points in an object is still a challenge in medical imaging (Hajnal et al., 2001), in particular for simple mammography projections that lack natural landmarks.”
BackgroundA Novel Optimization Algorithm Based on Reinforcement Learning
Starzyk, J. A., Liu, Y., & Batog, S. (2010) · Adaptation, learning, and optimization · doi:10.1007/978-3-642-12775-5_2 · Cited by 7
The Role of High Frequency Ultrasound in Multimodality Small Animal Imaging for Cancer Research
Liao, A.-H., & Li, P.-C. (2009) · doi:10.1016/s0929-6441(09)60115-6 · Cited by 6
Probabilistic Micro-earthquake Location For Reservoir Monitoring
Xuan, R., & Sava, P. (2009) · doi:10.1190/1.3255164 · Cited by 6
“Because MID is sensitive to a small number of voxels that have large intensity differences between two images (Hill et al., 2001), the plot of MID without a threshold (shown in Figure 2.”
Shape Modelling of Bones: Application to the Primate Shoulder
Yang, Y. (2008) · Spiral (Imperial College London) · doi:10.25560/4270 · Cited by 7
Normal Vector Information Registration and Comparisons with Mutual Information
Zhuang, X., & Gu, L. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260129 · Cited by 3
“As for the sampling which determines the accuracy in evaluating the similarity, NIV and MIM both sample 5-10% of the total pixels and NMI uses all pixels [10].”
MethodInfluentialNanayakkara, N., Chiu, B., Samani, A., Spence, J., Samarabandu, J., & Fenster, A. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.259219 · Cited by 6
Analyses of trabecular bone failure
Verhulp, E. E. (2006) · TU/e Research Portal · doi:10.6100/ir608109 · Cited by 8
Dual-Modality PET/CT Acquisition Systems for Clinical Oncology
Beyer, T., & Townsend, D. (2004) · doi:10.1007/978-3-642-18803-9_2 · Cited by 6
Schnabel, J. A., Tanner, C., Smith, A. D., Andreas Degenhard, B., Hayes, C., Leach, M. O., Hose, D. R., Hill, D., & Hawkes, D. J. (2002) · Informatik aktuell · doi:10.1007/978-3-642-55983-9_33 · Cited by 6
Self-citationGuo, W., Wang, L., Zeng, J., Han, Q., Jin, K., & Wang, X. (2025) · Neurocomputing · doi:10.1016/j.neucom.2025.131039 · Cited by 6
Shur, J. D., Porta, N., Kafaei, L., Pendower, L., McCall, J., Khan, N., Oyen, W. J. G., Koh, D., & Johnston, E. W. (2025) · Radiology Imaging Cancer · doi:10.1148/rycan.230147 · Cited by 7
Comparative analysis of alignment algorithms for macular optical coherence tomography imaging
Jones, C. K., Li, B., Wu, J., Nakaguchi, T., Xuan, P., & Liu, T. Y. A. (2023) · International Journal of Retina and Vitreous · doi:10.1186/s40942-023-00497-2 · Cited by 6
“Image alignment has many practical applications in medical image processing and analysis [13–15].”
BackgroundZhang, X., Gosnell, J. M., Nainamalai, V., Page, S., Huang, S., Haw, M. P., Peng, B., Vettukattil, J. J., & Jiang, J. (2023) · Diagnostics · doi:10.3390/diagnostics13182981 · Cited by 5
“Image Registration Image Registration One important step in multimodal image integration is image registration [48], as shown in 4.”
Background3D ultrasound guided navigation system with hybrid image fusion
Iommi, D., Valladares, A., Figl, M., Grahovac, M., Gabor Fichtinger, A., & Hummel, J. B. (2021) · Scientific Reports · doi:10.1038/s41598-021-86848-1 · Cited by 5
A novel Tungsten-based fiducial marker for multi-modal brain imaging
Ose, T., Autio, J. A., Ohno, M., Nishigori, K., Tanki, N., Igesaka, A., Mori, T., Doi, H., Wada, Y., Nakajima, I., et al. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.04.014 · Cited by 7
Seated versus supine: consideration of the optimum measurement posture for brain-dedicated PET
Iwao, Y., Tashima, H., Yoshida, E., Nishikido, F., Ida, T., & Yamaya, T. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab221d · Cited by 5
Eresen, A., Birch, S. M., Alić, L., Griffin, J. F., Kornegay, J. N., & Ji, J. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2870711 · Cited by 7
An Effective Diffeomorphic Model and Its Fast Multigrid Algorithm for Registration of Lung CT Images
Thompson, T., & Chen, K. (2019) · Computational Methods in Applied Mathematics · doi:10.1515/cmam-2018-0126 · Cited by 5
“The important role that registration plays in many aspects of medical imaging problems can be seen in recent works of [1, 16, 25, 27, 33].”
BackgroundSimilarity Metrics for Intensity-Based Registration Using Breast Density Maps
García, E., Oliver, A., Diez, Y., Díaz, O., Lladó, X., Martí, R., & Martí, J. (2017) · Iberian Conference on Pattern Recognition and Image Analysis · doi:10.1007/978-3-319-58838-4_24 · Cited by 5
Jiang, Z., Witz, J., Lecomte‐Grosbras, P., Dequidt, J., Cotin, S., Rubod, C., Christian Duriez, A., & Brieu, M. (2017) · Strain · doi:10.1111/str.12224 · Cited by 10
“Whereas the technique of full-field measurement based on IR and DIC has become mature in mechanical experiments and its application in medical images has been widely developed [12, 13, 14, 15], the issue of its limitations and inconveniences in our study should still be addressed.”
MethodMonocular LSD-SLAM Integration within AR System
Höll, M., & Lepetit, V. (2017) · arXiv.org · doi:10.13140/rg.2.2.10054.27205 · Cited by 5
“We lean here mainly on the book Medical Image Registration from Hill [6].”
Improvement of Lesion Detection by Complete Angular Compound Ultrasonic Elastography
Liu, C., & Zhou, Y. (2016) · Ultrasonic Imaging · doi:10.1177/0161734615627419 · Cited by 3
Nonrigid registration of remote sensing images via sparse and dense feature matching
Chen, J., Luo, L., Liu, C., Yu, J.-G., & Ma, J. (2016) · Journal of the Optical Society of America A · doi:10.1364/josaa.33.001313 · Cited by 5
Miri, M. S., Ghayoor, A., Johnson, H., & Sonka, M. (2016) · SPIE Medical Imaging · doi:10.1117/12.2214209 · Cited by 5
A novel approach to assess the treatment response using Gaussian random field in PET
Wang, M., Guo, N., Hu, G., Fakhri, G. E., Zhang, H., & Li, Q. (2016) · Medical Physics · doi:10.1118/1.4939879 · Cited by 3
Image registration using mutual information with correlation for medical image
Sahoo, P. K., & Pati, U. C. (2015) · Global Conference on Communication Technologies · doi:10.1109/gcct.2015.7342619 · Cited by 7
Image registration quality assessment with similarity measures - A research study
SindhuMadhuri, G., & Gandhi, M. P. I. (2015) · International Conference on Intelligent Cloud Computing · doi:10.1109/iccsp.2015.7322613 · Cited by 5
Sun, Y., Qiu, W., Yuan, J., Romagnoli, C., & Fenster, A. (2015) · Journal of medical imaging · doi:10.1117/1.jmi.2.2.025002 · Cited by 6
Metadata
- Authors
- Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J.
- Affiliations
- Guy's Hospital (GB)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2001-02-15
- Volume
- 46
- Issue
- 3
- Pages
- R1-R45
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2140139548
- Cited by
- 2,093
- References
- 127
- Citations by year
- 2026: 19 · 2025: 21 · 2024: 40 · 2023: 47 · 2022: 45 · 2021: 44 · 2020: 53 · 2019: 57 · 2018: 66 · 2017: 89 · 2016: 69 · 2015: 100 · 2014: 104 · 2013: 124 · 2012: 105
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Research Portal (King's College London) (submittedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Keywords
- medical image registration, multimodal image fusion, motion compensation, image-guided interventions, rigid transformation, non-rigid registration, tissue deformation, temporal image sequences
- MeSH terms
- Algorithms, Diagnostic Imaging, Humans, Image Processing, Computer-Assisted, Registries, Research
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.