Medical image registration
The DOI matches its Crossref record; 123 of the 123 references it cites were found in a registry or an index.
Abstract
Radiological images are increasingly being used in healthcare and medical research. There is, consequently, widespread interest in accurately relating information in the different images for diagnosis, treatment and basic science. This article reviews registration techniques used to solve this problem, and describes the wide variety of applications to which these techniques are applied. Applications of image registration include combining images of the same subject from different modalities, aligning temporal sequences of images to compensate for motion of the subject between scans, image guidance during interventions and aligning images from multiple subjects in cohort studies. Current registration algorithms can, in many cases, automatically register images that are related by a rigid body transformation (i.e. where tissue deformation can be ignored). There has also been substantial progress in non-rigid registration algorithms that can compensate for tissue deformation, or align images from different subjects. Nevertheless many registration problems remain unsolved, and this is likely to continue to be an active field of research in the future.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“General approaches address multimodal image registration by either performing image synthesis [22, 23] to change the problem to a uni-modal image registration task, or by proposing complex, hand-crafted [24, 25, 26, 27] or learned [28, 29, 30, 31, 32] multi-modal image similarity measures.”
From Quicksilver: Fast predictive image registration – A deep learning approach (2017) · cites this paper as [29]
Citations
Cites
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
A method for registration of 3-D shapes
Besl, P. J., & McKay, N. D. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121791 · Cited by 18,103
Co-Planar Stereotaxic Atlas of the Human Brain
Talairach, J., & Tournoux, P. (1988) · Medical Entomology and Zoology · Cited by 11,798
Communication in the presence of noise
Shannon, C. E. (1949) · Proceedings of the IRE · doi:10.1109/jrproc.1949.232969 · Cited by 6,539
Golub, G. H., & Loan, C. F. V. (1996) · Johns Hopkins University Press eBooks · Cited by 6,027
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Self-citationPrincipal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
Communication In The Presence Of Noise
Shannon, C. E. (1998) · Proceedings of the IEEE · doi:10.1109/jproc.1998.659497 · Cited by 4,804
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Research works printed but not linked: 7
- 10.1016/S1361-8415(96)80006-5 · doi:10.1016/s1361-8415(96)80006-5
- 10.1002/(SICI)1522-712X(1995)1:4<198::AID-IGS2>3.0.CO;2-5 · doi:10.1002/(sici)1522-712x(1995)1:4<198::aid-igs2>3.0.co;2-5
- 10.1002/(SICI)1522-2594(200004)43:4<583::AID-MRM13>3.0.CO;2-B · doi:10.1002/(sici)1522-2594(200004)43:4<583::aid-mrm13>3.0.co;2-b
- Press W H, 1992
- Sibson R, 1978, J. R. Statist. Soc., 40, 234
- 10.1002/(SICI)1522-2586(199910)10:4<582::AID-JMRI12>3.0.CO;2-X · doi:10.1002/(sici)1522-2586(199910)10:4<582::aid-jmri12>3.0.co;2-x
- 10.1016/S1361-8415(96)80004-1 · doi:10.1016/s1361-8415(96)80004-1
Cited by
Items 201–300 of 1,032
State of the Art of Level Set Methods in Segmentation and Registration of Medical Imaging Modalities
Angelini, E. D., Jin, Y., & Laine, A. F. (2007) · Springer eBooks · doi:10.1007/0-306-48608-3_2 · Cited by 46
Linear intensity-based image registration by Markov random fields and discrete optimization
Zikic, D., Glocker, B., Kutter, O., Groher, M., Komodakis, N., Kamen, A., Paragios, N., & Navab, N. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.04.003 · Cited by 59
A faster method for 3D/2D medical image registration—a simulation study
Birkfellner, W., Wirth, J., Burgstaller, W., Baumann, B., Staedele, H., Hammer, B., Gellrich, N. C., Jacob, A. L., Regazzoni, P., & Messmer, P. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/16/307 · Cited by 50
“Surface matching methods (Hill et al 2001) also appear problematic.”
Retinal Image Registration Using Geometrical Features
Gharabaghi, S., Daneshvar, S., & Sedaaghi, M. (2013) · Journal of digital imaging · doi:10.1007/s10278-012-9501-7 · Cited by 58
Elhawary, H., Oguro, S., Tuncali, K., Morrison, P. R., Tatlı, S., Shyn, P. B., Silverman, S. G., & Hata, N. (2010) · Academic Radiology · doi:10.1016/j.acra.2010.06.004 · Cited by 54
FLIRT with Rigidity—Image Registration with a Local Non-rigidity Penalty
Modersitzki, J. (2007) · International Journal of Computer Vision · doi:10.1007/s11263-007-0079-3 · Cited by 51
Computer-aided cephalometric landmark annotation for CBCT data
Codari, M., Caffini, M., Tartaglia, G. M., Sforza, C., & Baselli, G. (2016) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-016-1453-9 · Cited by 66
“21) to obtain the landmark estimate in the patient’s reference system, p̂ i [29]: p̂ i = Tapi (4)”
BackgroundRegistration of bimodal retinal images - improving modifications
Kubecka, L., & Jan, J. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1403510 · Cited by 58
An image-based computational hemodynamics study of the Systolic Anterior Motion of the mitral valve
Fumagalli, I., Fedele, M., Vergara, C., Dede’, L., Ippolito, S., Nicolò, F., Antona, C., Scrofani, R., & Quarteroni, A. M. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103922 · Cited by 55
Hybrid retinal image registration using phase correlation
Kolář, R., Harabiš, V., & Odstrčilík, J. (2012) · The Imaging Science Journal · doi:10.1179/1743131x11y.0000000065 · Cited by 49
Towards applying content-based image retrieval in the clinical routine
Oliveira, M., Cirne, W., & Marques, P. M. D. A. (2007) · Future generations computer systems · doi:10.1016/j.future.2006.06.009 · Cited by 56
Evaluation of image matching techniques for optical fiber specklegram sensor analysis
Fujiwara, E., Ri, Y., Wu, Y. T., Fujimoto, H., & Suzuki, C. K. (2018) · Applied Optics · doi:10.1364/ao.57.009845 · Cited by 73
Development and comparison of new hybrid motion tracking for bronchoscopic navigation
Luó, X., Feuerstein, M., Deguchi, D., Kitasaka, T., Takabatake, H., & Mori, K. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.11.001 · Cited by 57
Groupwise registration based on hierarchical image clustering and atlas synthesis
Wang, Q., Chen, L., Yap, P., Wu, G., & Shen, D. G. (2010) · Human Brain Mapping · doi:10.1002/hbm.20923 · Cited by 52
“…in aiding alignment and comparison of longitudinal and cross-sectional data, thus facilitating diagnosis, guiding treatments, and monitoring disease progression [Woods et al., 1992; Hajnal et al., 1995; Maintz and Viergever, 1998; Holden et al., 2000; Hill et al., 2001; Zitova´ and Flusser, 2003].”
BackgroundA robust and interpretable deep learning framework for multi-modal registration via keypoints
Wang, A. Q., Yu, E. M., Dalca, A. V., & Sabuncu, M. (2023) · Medical Image Anal. · doi:10.48550/arxiv.2304.09941 · Cited by 53
“Pairwise iterative, optimization-based approaches have been extensively studied in medical image registration (Hill et al., 2001; Oliveira and Tavares, 2014).”
Muenzing, S. E. A., van Ginneken, B., Murphy, K., & Pluim, J. P. W. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.06.010 · Cited by 51
“Image registration is a crucial step in many image analysis tasks (Hill et al., 2001; Lester and Arridge, 1999; Maintz and Viergever, 1998).”
BackgroundSegmentation of Brain MRI in Young Children
Deprez, M., Dyet, L. E., Edwards, A. D., Rutherford, M., Hajnal, J. V., & Rueckert, D. (2007) · Academic Radiology · doi:10.1016/j.acra.2007.07.020 · Cited by 62
An enhanced block matching algorithm for fast elastic registration in adaptive radiotherapy
Malsch, U., Thieke, C., Huber, P. E., & Bendl, R. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/19/005 · Cited by 45
Image-based RSA: Roentgen stereophotogrammetric analysis based on 2D–3D image registration
Bruin, P. W. D., Kaptein, B. L., Stoel, B. C., Reiber, J. H. C., Rozing, P. M., & Valstar, E. R. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.07.002 · Cited by 68
Deep learning-based multimodal image analysis for cervical cancer detection
Ming, Y., Dong, X., Zhao, J., Chen, Z., Wang, H. H., & Wu, N. (2022) · Methods · doi:10.1016/j.ymeth.2022.05.004 · Cited by 64
Semiautomated intraocular laser surgery using handheld instruments
Becker, B. C., MacLachlan, R. A., Lobes, L. A., & Riviere, C. N. (2010) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20897 · Cited by 47
The role of intensity standardization in medical image registration
Bağcı, U., Udupa, J. K., & Bai, L. (2009) · Pattern Recognition Letters · doi:10.1016/j.patrec.2009.09.010 · Cited by 44
Torbali, M. E., Zolotas, A. C., & Avdelidis, N. P. (2023) · Applied Sciences · doi:10.3390/app13042732 · Cited by 68
“As a vital matter, especially in the medical image fusion field, registration has been widely investigated with methods ranging from transformation or similarity-based methods [38,39] to novel AI-based strategies [40,41] in the literature.”
MethodDeepReg: a deep learning toolkit for medical image registration
Fu, Y., Montaña-Brown, N., Saeed, S. U., Casamitjana, A., Baum, Z. M. C., Delaunay, R., Yang, Q., Grimwood, A., Min, Z., Blumberg, S. B., et al. (2020) · The Journal of Open Source Software · doi:10.21105/joss.02705 · Cited by 59
“Medical image registration, computational algorithms that align different images together [1], has in recent years turned the research attention towards deep learning.”
Dolz, J., Massoptier, L., & Vermandel, M. (2015) · IRBM · doi:10.1016/j.irbm.2015.06.001 · Cited by 58
Lee, D., Nam, W. H., Lee, J. Y., & Ra, J. B. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/008 · Cited by 51
The accuracy and reliability of 3D CT/MRI co-registration in planning epilepsy surgery.
Tao, J. X., Hawes-Ebersole, S., Baldwin, M. E., Shah, S., Erickson, R., & Ebersole, J. S. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.02.002 · Cited by 51
“, 2005), and 3D CT/MRI co-registration (Hill et al., 2001; Wellmer et al., 2002).”
BackgroundGan, R., & Chung, A. C. S. (2005) · Lecture notes in computer science · doi:10.1007/11505730_18 · Cited by 48
Tanner, C., Schnabel, J., Degenhard, A., Castellano-Smith, A. D., Hayes, C., Leach, M., Hose, D., Hill, D., & Hawkes, D. (2002) · International Conference on Medical Image Computing and Computer-Assisted Intervention · doi:10.1007/3-540-45786-0_38 · Cited by 51
Self-citationFast elastic registration of soft tissues under large deformations
Peterlík, I., Courtecuisse, H., Rohling, R., Abolmaesumi, P., Nguan, C., Cotin, S., & Salcudean, S. (2017) · Medical Image Anal. · doi:10.1016/j.media.2017.12.006 · Cited by 50
“The computer-based methods related to patient diagnosis and pre-and post-operative treatment represent an important set of applications requiring accurate and reliable registration of medical images (Hill et al., 2001; Khalifa et al., 2011; Crum et al., 2014).”
Nonlinear Shape Registration without Correspondences
Domokos, C., Nemeth, J., & Kató, Z. (2011) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2011.200 · Cited by 46
Robust Automatic Knee MR Slice Positioning Through Redundant and Hierarchical Anatomy Detection
Zhan, Y., Dewan, M., Harder, M., Krishnan, A., & Zhou, X. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2162634 · Cited by 50
Balluff, B., Heeren, R. M. A., & Race, A. M. (2021) · Journal of Mass Spectrometry and Advances in the Clinical Lab · doi:10.1016/j.jmsacl.2021.12.006 · Cited by 68
“Image registration is a broad field of research, with applications in medical imaging [11], remote sensing [12] and astronomy [13].”
BackgroundSöhn, M., Birkner, M., Chi, Y., Wang, J., Yan, D., Berger, B., & Alber, M. L. (2008) · Medical Physics · doi:10.1118/1.2836951 · Cited by 41
A contour-guided deformable image registration algorithm for adaptive radiotherapy
Gu, X., Dong, B., Wang, J., Yordy, J. S., Mell, L. K., Jia, X., & Jiang, S. B. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/6/1889 · Cited by 49
“It is a process to precisely establish voxel-to-voxel correspondence of two images collected at different time or with 5 different image modalities (Hill et al., 2001; Crum et al., 2004).”
MethodLu, C., Chelikani, S., Jaffray, D. A., Milosevic, M., Staib, L. H., & Duncan, J. S. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2186976 · Cited by 44
Constrained non-rigid registration for use in image-guided adaptive radiotherapy
Greene, W. H., Chelikani, S., Purushothaman, K., Knisely, J., Chen, Z., Papademetris, X., Staib, L., & Duncan, J. (2009) · Medical Image Anal. · doi:10.1016/j.media.2009.07.004 · Cited by 48
“Although the planning and treatment-day images are inter-modal, the object segmentations are binary which allows a direct comparison of image intensities to be used as a registration metric (Hill et al., 2001).”
Nonrigid registration of brain MRI using NURBS
Wang, J., & Jiang, T. (2007) · Pattern Recognition Letters · doi:10.1016/j.patrec.2006.07.005 · Cited by 48
A review of computer-aided oral and maxillofacial surgery: planning, simulation and navigation
Chen, X., Xu, L., Sun, Y., & Politis, C. (2016) · Expert Review of Medical Devices · doi:10.1080/17434440.2016.1243054 · Cited by 47
“Although the ‘rigid body’ registration simplifies the registration process, it has quite limited applicability since the deformation or distortion of anatomical and pathological structures of interest are not considered between image acquisitions [53].”
BackgroundComputed tomography-magnetic resonance image registration in radiotherapy treatment planning.
Brunt, J. (2010) · Clinics in oncology · doi:10.1016/j.clon.2010.06.016 · Cited by 47
Multi-Modal Medical Image Registration with Full or Partial Data: A Manifold Learning Approach
Bashiri, F. S., Baghaie, A., Rostami, R., Yu, Z., & D’Souza, R. M. (2018) · Journal of Imaging · doi:10.3390/jimaging5010005 · Cited by 46
Alyami, W. M., Kyme, A. Z., & Bourne, R. (2020) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27409 · Cited by 47
A Review on the Extraction of Quantitative Retinal Microvascular Image Feature
Kipli, K., Hoque, M. E., Lim, L. T., Mahmood, M. H., Sahari, S. K., Sapawi, R., Rajaee, N., & Joseph, A. (2018) · Computational and Mathematical Methods in Medicine · doi:10.1155/2018/4019538 · Cited by 55
“In biomedical engineering, digital image processing is being applied in many researches and diagnosing the diseases, planning and supervising treatment for that disease, and monitoring the state of diseases simultaneously [78].”
BackgroundThree-dimensional registration of tomography data for quantification in biomaterials science
Müller, B., Deyhle, H., Lang, S., Schulz, G., Bormann, T., Fierz, F., & Hieber, S. (2012) · doi:10.3139/146.110663 · Cited by 46
A Statistical Parts-Based Model of Anatomical Variability
Toews, M., & Arbel, T. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.892510 · Cited by 48
Hernes, T. A. N., Lindseth, F., Selbekk, T., Wollf, A., Solberg, O. V., Harg, E., Rygh, O. M., Tangen, G. A., Rasmussen, I., Augdal, S., et al. (2006) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.68 · Cited by 34
Tomography-based 3-D anisotropic elastography using boundary measurements
Liu, Y., Sun, L., & Wang, G. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.857232 · Cited by 39
High-Throughput Screening in Primary Neurons
Sharma, P., Ando, D. M., Daub, A. C., Kaye, J., & Finkbeiner, S. M. (2012) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/b978-0-12-391856-7.00041-x · Cited by 52
Kim, S., Feng, L., Grimm, R., Freed, M. E., Block, K. T., Sodickson, D. K., Moy, L. P., & Otazo, R. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24961 · Cited by 53
“and/or offset, as demonstrated in various image co-registration applications.(14,15,17,18) Similar types of measures based on the image gradient, gradient difference (GDF) 14,19 and gradient cross-correlation (GCC),(14,20,21) are also included as these measures give more weight”
BackgroundLeng, S., Shiung, M. S., Ai, S.-T., Qu, M.-L., Vrtiska, T., Grant, K., Krauss, B., Schmidt, B., Lieske, J., & McCollough, C. (2015) · AJR. American journal of roentgenology · doi:10.2214/ajr.13.11911 · Cited by 45
“We hypothesized that the use of commercially available 3D deformable registration techniques [28, 29] can register the data from two separate scans with sufficient accuracy to allow accurate stone differentiation analysis using dual-energy CT techniques.”
Semi-automatic landmark point annotation for geometric morphometrics
Bromiley, P. A., Schunke, A. C., Ragheb, H., Thacker, N. A., & Tautz, D. (2014) · Frontiers in Zoology · doi:10.1186/s12983-014-0061-1 · Cited by 133
“[27] described a hierarchical approach, in which a grid of overlapping sub-regions were independently registered using cost functions based on mutual information (MI; [12], [43], [44]), normalised mutual information (NMI; [40]) and the correlation coefficient (CC; [23]), without a regularisation term.”
BackgroundMethodPallone, M., Poplack, S., Avutu, H. B. R., Paulsen, K., & Barth, R. (2014) · Annals of Surgical Oncology · doi:10.1245/s10434-014-3598-5 · Cited by 45
Validation of three deformable image registration algorithms for the thorax
Latifi, K., Zhang, G. G., Stawicki, M., van Elmpt, W., Dekker, A. L. A. J., & Forster, K. M. (2013) · Journal of Applied Clinical Medical Physics · doi:10.1120/jacmp.v14i1.3834 · Cited by 38
Sykes, J., Brettle, D., Magee, D., & Thwaites, D. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/24/002 · Cited by 45
“Image registration (IR) is the process of establishing correspondence between two images (Hill et al 2001).”
BackgroundMethodHybrid multiscale landmark and deformable image registration.
Paquin, D., Levy, D., & Xing, L. (2007) · Mathematical biosciences and engineering : MBE · doi:10.3934/mbe.2007.4.711 · Cited by 45
A hybrid methodology for breast screening and cancer diagnosis using thermography
Resmini, R., da Silva, L. F., Medeiros, P. R. T., Araújo, A. S., Muchaluat-Saade, D., & Conci, A. (2021) · Comput. Biol. Medicine · doi:10.1016/j.compbiomed.2021.104553 · Cited by 44
A concept for holistic whole body MRI data analysis, Imiomics
Strand, R., Malmberg, F., Johansson, L., Lind, L., Sundbom, M., Ahlström, H. K., & Kullberg, J. (2017) · PLoS ONE · doi:10.1371/journal.pone.0169966 · Cited by 60
Automated threshold-independent cortex segmentation by 3D-texture analysis of HR-pQCT scans
Valentinitsch, A., Patsch, J., Deutschmann, J., Schueller-Weidekamm, C., Resch, H., Kainberger, F. M., & Langs, G. (2012) · Bone · doi:10.1016/j.bone.2012.06.005 · Cited by 42
“sum of squared intensity differences— SSD) by changing the alignment of high- and low resolution volume [14].”
BackgroundAn information-theoretic method for multimodality medical image registration
Khader, M., & Hamza, A. B. (2011) · Expert Systems with Applications · doi:10.1016/j.eswa.2011.11.064 · Cited by 47
“Multimodal image registration is among the most challenging problems in medical imaging, and it is of paramount importance in medical diagnosis and computer aided surgery (Bankman, 2008; Hajnal et al., 2001).”
BackgroundAutomated aortic calcium scoring on low‐dose chest computed tomography
Išgum, I., Rutten, A., Prokop, M., Staring, M., Klein, S., Pluim, J. P. W., Viergever, M. A., & van Ginneken, B. (2010) · Medical Physics · doi:10.1118/1.3284211 · Cited by 48
“The maximum number of features to be selected was set to 3, 5, 15, 25, and 35.”
BackgroundNonrigid registration with tissue-dependent filtering of the deformation field
Staring, M., Klein, S., & Pluim, J. P. W. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/23/007 · Cited by 40
“Nonrigid image registration is an important technique in the field of medical image processing (Hill et al 2001, Lester and Arridge 1999, Maintz and Viergever 1998).”
MethodKnee bone segmentation from MRI: A classification and literature review
Aprovitola, A., & Gallo, L. (2016) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2015.12.007 · Cited by 56
Landmark-Matching Transformation with Large Deformation Via n-dimensional Quasi-conformal Maps
Lee, Y. T., Lam, K. C., & Lui, L. M. (2015) · Journal of Scientific Computing · doi:10.1007/s10915-015-0113-5 · Cited by 42
“Finding an optimal transformation between corresponding data, such as images or geometric shapes, is an important task in various fields, such as computer vision [61], computer graphics [6,22,24], video processing [38,45,59,60] and medical imaging [1,25,28,29,32,49,55].”
BackgroundUltrasound-to-computer-tomography registration for image-guided laparoscopic liver surgery
Bao, P., Warmath, J. R., Galloway, R. L., & Herline, A. (2005) · Surgical Endoscopy · doi:10.1007/s00464-004-8902-1 · Cited by 43
Ruchala, K., Olivera, G., Kapatoes, J., Reckwerdt, P., & Mackie, T. (2002) · Medical Physics (Lancaster) · doi:10.1118/1.1513163 · Cited by 43
Nonrigid Image Registration Using an Entropic Similarity
Khader, M., & Hamza, A. B. (2011) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2159806 · Cited by 42
Tseng, C., Sussman, M., Atenafu, E., Létourneau, D., Ma, L.-J., Soliman, H., Thibault, I., Cho, B. C. J., Simeonov, A., Yu, E., et al. (2015) · International Journal of Radiation Oncology, Biology, Physics · doi:10.1016/j.ijrobp.2014.12.037 · Cited by 41
Automated hexahedral meshing of anatomic structures using deformable registration
Grosland, N. M., Bafna, R., & Magnotta, V. A. (2008) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840802136143 · Cited by 30
“A number of algorithms have been developed for deformable image registration (Brown 1992; Gaens et al. 1998; Hagemann et al. 1999; Hill et al. 2001).”
MethodEvaluation of Brain MRI Alignment with the Robust Hausdorff Distance Measures
Fedorov, A., Billet, E., Prastawa, M. W., Gerig, G., Radmanesh, A., Warfield, S. K., Kikinis, R., & Chrisochoides, N. P. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-89639-5_57 · Cited by 44
“, phantoms, animal studies, cadavers, manually pre-labeled datasets) [1].”
BackgroundChiarelli, A., Maclin, E., Low, K. A., Fabiani, M., & Gratton, G. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.1.016009 · Cited by 41
Information theoretic regularization in diffuse optical tomography
Panagiotou, C., Somayajula, S., Gibson, A. P., Schweiger, M. J., Leahy, R. M., & Arridge, S. (2009) · Journal of the Optical Society of America A · doi:10.1364/josaa.26.001277 · Cited by 37
Symmetric Non-rigid Registration: A Geometric Theory and Some Numerical Techniques
Tagare, H. D., Groisser, D., & Škrinjar, O. M. (2009) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-008-0129-7 · Cited by 43
Liu, H., Lv, T., Wang, N.-N., Zhao, F., Wang, K.-T., & Liu, D.-X. (2011) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2010.07.018 · Cited by 40
Yip, S. S. F., Coroller, T. P., Sanford, N. N., Huynh, E., Mamon, H. J., Aerts, H. J. W. L., & Berbeco, R. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/2/906 · Cited by 51
Medical image registration based on SURF detector
Lukashevich, P., Zalesky, B. A., & Ablameyko, S. (2011) · Pattern Recognition and Image Analysis · doi:10.1134/s1054661811020696 · Cited by 41
Matching of anatomical tree structures for registration of medical images
Metzen, J. H., Kröger, T., Schenk, A., Zidowitz, S., Peitgen, H., & Jiang, X. (2008) · Image and Vision Computing · doi:10.1016/j.imavis.2008.04.002 · Cited by 30
“[2], registration is the process of transforming different image data sets into one coordinate system.”
BackgroundNon-rigid Registration for Large Sets of Microscopic Images on Graphics Processors
Ruiz, A., Ujaldón, M., Cooper, L. A. D., & Huang, K. (2008) · Journal of Signal Processing Systems · doi:10.1007/s11265-008-0208-4 · Cited by 39
3D interfractional patient position verification using 2D‐3D registration of orthogonal images
Jans, H. ‐., Syme, A. M., Rathee, S., & Fallone, B. G. (2006) · Medical Physics · doi:10.1118/1.2192907 · Cited by 36
Multimodal Brain Image Registration Based on Wavelet Transform Using SAD and MI
Wu, J., & Chung, A. C. S. (2004) · Medical Imaging and Augmented Reality · doi:10.1007/978-3-540-28626-4_33 · Cited by 39
Somer, E. J., Marsden, P. K., Benatar, N. A., Goodey, J., O'Doherty, M. J., & Smith, M. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-0994-z · Cited by 38
Performance validation of deformable image registration in the pelvic region
Zambrano, V., Furtado, H., Fabri, D., Lütgendorf‐Caucig, C., Góra, J., Stock, M., Mayer, R., Birkfellner, W., & Georg, D. (2013) · Journal of Radiation Research · doi:10.1093/jrr/rrt045 · Cited by 36
Estimation of the Transverse Strain Tensor in the Arterial Wall Using IVUS Image Registration
Liang, Y., Zhu, H., & Friedman, M. H. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.04.005 · Cited by 35
“This problem can be solved by nonrigid image registration using deformable models (Crum et al. 2004; Zitova and Flusser 2003), which have been widely used in medical image analysis (Hill et al. 2001; Maintz and Viergever 1998).”
Cadaver validation of intensity-based ultrasound to CT registration
Penney, G., Barratt, D. C., Chan, C. S. K., Slomczykowski, M., Carter, T. J., Edwards, P., & Hawkes, D. J. (2006) · Medical Image Analysis · doi:10.1016/j.media.2006.01.003 · Cited by 84
Self-citationEstimation of Organ Motion from 4D CT for 4D Radiation Therapy Planning of Lung Cancer
Kaus, M., Netsch, T., Kabus, S., Pekar, V., McNutt, T., & Fischer, B. (2004) · International Conference on Medical Image Computing and Computer-Assisted Intervention · doi:10.1007/978-3-540-30136-3_123 · Cited by 38
“methods exists, including volumetric intensity-based registration techniques [4] and surface-based techniques [5].”
MethodNeuronavigation accuracy dependence on CT and MR imaging parameters: a phantom-based study
Poggi, S., Pallotta, S., Russo, S., Gallina, P., Torresin, A., & Bucciolini, M. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/14/311 · Cited by 51
“The effect of the image quality on the registration procedure, in contrast is crucial; many registration algorithms are rigid (Hill et al 2001), and heavily depend on the absence of distortions in images.”
BackgroundMethodMeijering, E. H. W., Smal, I., Dzyubachyk, O., & Olivo‐Marín, J. (2008) · Elsevier eBooks · doi:10.1016/b978-0-12-372578-3.00015-5 · Cited by 40
Improving SAR estimations in MRI using subject-specific models
Jin, J., Liu, F., Weber, E., & Crozier, S. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/24/8153 · Cited by 37
Mulé, S., Kachenoura, N., Lucidarme, O., de Oliveira, A. D., Pellot-Barakat, C., Herment, A., & Frouin, F. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/16/005 · Cited by 37
Linte, C. A., White, J. A., Eagleson, R. A., Guiraudon, G. M., & Peters, T. M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2082522 · Cited by 41
Park, H., Meyer, C., Wood, D., Khan, A., Shah, R., Hussain, H., Siddiqui, J., Seo, J., Chenevert, T., & Piert, M. (2010) · Academic Radiology · doi:10.1016/j.acra.2010.01.003 · Cited by 37
“Registration methods were well reviewed by Hill et al (15).”
BackgroundMethodInfluentialCámara, Ó., Delso, G., Olivier Colliot, A., Ingelmo, A. M., & Isabelle Bloch, A. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.889712 · Cited by 38
A Novel Projection Based Approach for Medical Image Registration
Khamene, A., Chisu, R., Wein, W., Navab, N., & Sauer, F. (2006) · Lecture notes in computer science · doi:10.1007/11784012_30 · Cited by 32
Microscopic image analysis for quantitative characterization of muscle fiber type composition
Sertel, O., Dogdas, B., Chiu, C. S., & Gürcan, M. N. (2011) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2011.01.009 · Cited by 35
Integration of confocal and atomic force microscopy images
Kondra, S., Laishram, J., Ban, J., Migliorini, E., Foggia, V. D., Lazzarino, M., Torre, V., & Ruaro, M. E. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.09.034 · Cited by 35
Assessment of dose reconstruction errors in image-guided radiation therapy
Zhong, H., Weiss, E., & Siebers, J. V. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/3/013 · Cited by 34
Geometrical regularization of displacement fields for histological image registration
Pitiot, A., & Guimond, A. (2007) · Medical Image Analysis · doi:10.1016/j.media.2007.06.007 · Cited by 28
A GPGPU Approach for Accelerating 2-D/3-D Rigid Registration of Medical Images
Ino, F., Gomita, J., Kawasaki, Y., & Hagihara, K. (2006) · Lecture notes in computer science · doi:10.1007/11946441_84 · Cited by 32
Illumination insensitive recognition using eigenspaces
Bischof, H., Wildenauer, H., & Leonardis, A. (2004) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2004.01.002 · Cited by 36
Riyahi, S., Choi, W., Liu, C., Zhong, H., Wu, A. J.-C., Mechalakos, J., & Lü, W. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aacd22 · Cited by 48
Laghrib, A., Ezzaki, M., Rhabi, M. E., Hakim, A., Monasse, P., & Raghay, S. (2017) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2017.08.007 · Cited by 38
Metadata
- Authors
- Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J.
- Affiliations
- Guy's Hospital (GB)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2001-02-15
- Volume
- 46
- Issue
- 3
- Pages
- R1-R45
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2140139548
- Cited by
- 2,093
- References
- 127
- Citations by year
- 2026: 19 · 2025: 21 · 2024: 40 · 2023: 47 · 2022: 45 · 2021: 44 · 2020: 53 · 2019: 57 · 2018: 66 · 2017: 89 · 2016: 69 · 2015: 100 · 2014: 104 · 2013: 124 · 2012: 105
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Research Portal (King's College London) (submittedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Keywords
- medical image registration, multimodal image fusion, motion compensation, image-guided interventions, rigid transformation, non-rigid registration, tissue deformation, temporal image sequences
- MeSH terms
- Algorithms, Diagnostic Imaging, Humans, Image Processing, Computer-Assisted, Registries, Research
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.