Medical image registration
The DOI matches its Crossref record; 123 of the 123 references it cites were found in a registry or an index.
Abstract
Radiological images are increasingly being used in healthcare and medical research. There is, consequently, widespread interest in accurately relating information in the different images for diagnosis, treatment and basic science. This article reviews registration techniques used to solve this problem, and describes the wide variety of applications to which these techniques are applied. Applications of image registration include combining images of the same subject from different modalities, aligning temporal sequences of images to compensate for motion of the subject between scans, image guidance during interventions and aligning images from multiple subjects in cohort studies. Current registration algorithms can, in many cases, automatically register images that are related by a rigid body transformation (i.e. where tissue deformation can be ignored). There has also been substantial progress in non-rigid registration algorithms that can compensate for tissue deformation, or align images from different subjects. Nevertheless many registration problems remain unsolved, and this is likely to continue to be an active field of research in the future.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“General approaches address multimodal image registration by either performing image synthesis [22, 23] to change the problem to a uni-modal image registration task, or by proposing complex, hand-crafted [24, 25, 26, 27] or learned [28, 29, 30, 31, 32] multi-modal image similarity measures.”
From Quicksilver: Fast predictive image registration – A deep learning approach (2017) · cites this paper as [29]
Citations
Cites
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
A method for registration of 3-D shapes
Besl, P. J., & McKay, N. D. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121791 · Cited by 18,103
Co-Planar Stereotaxic Atlas of the Human Brain
Talairach, J., & Tournoux, P. (1988) · Medical Entomology and Zoology · Cited by 11,798
Communication in the presence of noise
Shannon, C. E. (1949) · Proceedings of the IRE · doi:10.1109/jrproc.1949.232969 · Cited by 6,539
Golub, G. H., & Loan, C. F. V. (1996) · Johns Hopkins University Press eBooks · Cited by 6,027
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Self-citationPrincipal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
Communication In The Presence Of Noise
Shannon, C. E. (1998) · Proceedings of the IEEE · doi:10.1109/jproc.1998.659497 · Cited by 4,804
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Research works printed but not linked: 7
- 10.1016/S1361-8415(96)80006-5 · doi:10.1016/s1361-8415(96)80006-5
- 10.1002/(SICI)1522-712X(1995)1:4<198::AID-IGS2>3.0.CO;2-5 · doi:10.1002/(sici)1522-712x(1995)1:4<198::aid-igs2>3.0.co;2-5
- 10.1002/(SICI)1522-2594(200004)43:4<583::AID-MRM13>3.0.CO;2-B · doi:10.1002/(sici)1522-2594(200004)43:4<583::aid-mrm13>3.0.co;2-b
- Press W H, 1992
- Sibson R, 1978, J. R. Statist. Soc., 40, 234
- 10.1002/(SICI)1522-2586(199910)10:4<582::AID-JMRI12>3.0.CO;2-X · doi:10.1002/(sici)1522-2586(199910)10:4<582::aid-jmri12>3.0.co;2-x
- 10.1016/S1361-8415(96)80004-1 · doi:10.1016/s1361-8415(96)80004-1
Cited by
Items 401–500 of 1,032
Urschler, M., Höller, J., Bornik, A., Paul, T., Giretzlehner, M., Bischof, H., Yen, K., & Scheurer, E. (2014) · Forensic Science International · doi:10.1016/j.forsciint.2014.05.017 · Cited by 23
Validation of a passive stereophotogrammetry system for imaging of the breast: a geometric analysis.
Catherwood, T., McCaughan, E., Greer, E., Spence, R. A. J., McIntosh, S., & Winder, R. (2011) · Medical Engineering and Physics · doi:10.1016/j.medengphy.2011.02.005 · Cited by 23
Balachandran, R., Fitzpatrick, J., & Labadie, R. (2008) · Otology and Neurotology · doi:10.1097/mao.0b013e3181859a08 · Cited by 23
Projection extension for region of interest imaging in cone-beam CT.
Wiegert, J., Bertram, M., Netsch, T., Wulff, J., Weese, J., & Rose, G. (2005) · Academic Radiology · doi:10.1016/j.acra.2005.04.017 · Cited by 23
Hamm, K., Surber, G., Schmücking, M., Wurm, R., Aschenbach, R., Kleinert, G., Niesen, A., & Baum, R. (2004) · Journal of Neurosurgery · doi:10.3171/sup.2004.101.supplement3.0326 · Cited by 23
Galib, S. M., Lee, H., Guy, C. L., Riblett, M. J., & Hugo, G. D. (2019) · Medical Physics · doi:10.1002/mp.13890 · Cited by 29
Image Registration of Structural and Physiological MR Images of Abnormal Anatomy
Mang, A., Cámara, Ó., Caseiras, G. B., Crum, W. R., Schnabel, J. A., Buzug, T. M., Thornton, J. S., Jäger, H. R., & Hawkes, D. J. (2007) · Springer eBooks · doi:10.1007/978-3-540-68764-1_35 · Cited by 24
Self-citationDeformable Image Registration for Radiation Therapy Planning: Algorithms and Applications
Kaus, M., & Brock, K. (2007) · doi:10.1142/9789812770042_0001 · Cited by 23
Motion-correction strategies for enhancing whole-body PET imaging
Wang, J., Bermudez, D. H., Chen, W., Durgavarjhula, D., Randell, C., Uyanik, M., & McMillan, A. B. (2024) · Frontiers in Nuclear Medicine · doi:10.3389/fnume.2024.1257880 · Cited by 22
Ghaffari, A., & Fatemizadeh, E. (2014) · IET Image Processing · doi:10.1049/iet-ipr.2013.0575 · Cited by 22
Jo, H., Hong, H., & Goo, J. (2014) · Comput. Biol. Medicine · doi:10.1016/j.compbiomed.2013.10.028 · Cited by 22
Research and development of medical image fusion
Yang, W., & Liu, J.-R. (2013) · 2013 IEEE International Conference on Medical Imaging Physics and Engineering · doi:10.1109/icmipe.2013.6864557 · Cited by 22
“And the positioning accuracy is higher than the one from single image([4,22]).”
BackgroundIsola, A., Schmitt, H., van Stevendaal, U., Begemann, P. G. C., Coulon, P., Boussel, L., & Grass, M. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/18/010 · Cited by 22
“A post-processing misalignment correction, also called image registration, represents a potential solution to increase time sequence alignment (Rueckert et al. 1999, Hill et al. 2001, Kybic & Unser 2003, Crum et al. 2004).”
BackgroundTsai, C.-L., Lister, J. P., Bjornsson, C. S., SMITH, K., Shain, W. G., Barnes, C. A., & Roysam, B. (2011) · Journal of Microscopy · doi:10.1111/j.1365-2818.2011.03489.x · Cited by 22
Künzler, T., Grezdo, J., Bogner, J., Birkfellner, W., & Georg, D. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/8/008 · Cited by 22
Penning, L., Irwan, R., & Oudkerk, M. (2005) · European spine journal · doi:10.1007/s00586-004-0761-x · Cited by 22
“With the ROIs of the sacrum matched, the ROIs of L5 were in the positions of flexion and extension with respect to the sacrum.”
MethodInfluentialMedical image registration in computational intelligence framework: a review
Ramirez, L., Durdle, N. G., & Raso, V. (2003) · Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2003.1226069 · Cited by 22
Wang, X., Eberl, S., FULHAM, M. J., Som, S. S., & Feng, D. D. (2008) · Elsevier eBooks · doi:10.1016/b978-012373583-6.50012-8 · Cited by 30
Registration of 2D x-ray images to 3D MRI by generating pseudo-CT data
van der Bom, M. J., Pluim, J. P. W., Gounis, M. J., van de Kraats, E. B., Sprinkhuizen, S. M., Timmer, J., Homan, R., & Bartels, L. W. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/010 · Cited by 21
Meenakshi, K., Swaraja, K., & Kora, P. (2020) · Multimedia Tools and Applications · doi:10.1007/s11042-020-09250-5 · Cited by 22
“DE is the most competent and flexible evolutionary computing algorithm used in various domains such as image retrieval [18, 51], watermarking [43], image registration [20], forensic image processing [12] and thermodynamics, process control and industrial automation [19].”
BackgroundAnatomically-adaptive multi-modal image registration for image-guided external-beam radiotherapy
Zachiu, C., de Senneville, B. D., Willigenburg, T., van Zyp, J. V. V. V., de Boer, J. D., Raaymakers, B., & Ries, M. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/abad7d · Cited by 21
Nacereddine, N., Tabbone, S., & Ziou, D. (2015) · Pattern Recognition · doi:10.1016/j.patcog.2015.01.017 · Cited by 21
A survey on image-based continuum-body motion estimation
Liu, W., & Ribeiro, E. (2011) · Image and Vision Computing · doi:10.1016/j.imavis.2011.03.003 · Cited by 21
“Besides stationary Gaussian noise, real-world imagery may contain spatially varying distortions, occlusions, and specular-reflectance artifacts [39].”
BackgroundLaishram, J., Kondra, S., Avossa, D., Migliorini, E., Lazzarino, M., & Torre, V. (2009) · Journal of Structural Biology · doi:10.1016/j.jsb.2009.09.005 · Cited by 21
“The word Registration is used with two different meanings (Hill et al., 2001).”
MethodCurve-based 2D-3D registration of coronary vessels for image guided procedure
Duong, L., Liao, R., Sundar, H., Tailhades, B., Meyer, A., & Xu, C.-Y. (2009) · Medical Imaging · doi:10.1117/12.811874 · Cited by 21
Bhattacharya, M., & Das, A. (2007) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2007.4436755 · Cited by 16
“The gold standard utilizes markers placed on the region of interest [2].”
BackgroundA combined micro-PET/CT scanner for small animal imaging
Jan, M., Ni, Y.-C., Chen, K.-W., Liang, H.-C., Chuang, K., & Fu, Y.-K. (2006) · doi:10.1016/j.nima.2006.08.106 · Cited by 21
Anatomically Guided Registration of Whole Body Mouse MR Images
Kovačević, N., Hamarneh, G., & Henkelman, R. M. (2003) · Lecture notes in computer science · doi:10.1007/978-3-540-39903-2_106 · Cited by 21
Yoo, H., Choi, A., & Mun, J. (2020) · doi:10.1007/s12206-020-0540-6 · Cited by 20
Multivariate Pointwise Information-Driven Data Sampling and Visualization
Dutta, S., Biswas, A., & Ahrens, J. P. (2019) · Entropy · doi:10.3390/e21070699 · Cited by 24
“MI has also been applied successfully for data fusion and image registration [31–35].”
MethodRecent Advances in Hybrid Molecular Imaging Systems
Kim, J., & Lee, J. H. (2014) · Seminars in Musculoskeletal Radiology · doi:10.1055/s-0034-1371014 · Cited by 21
Automatic registration of optical imagery with 3d lidar data using local combined mutual information
Parmehr, E. G., Fraser, C., Zhang, C.-S., & Leach, J. (2013) · doi:10.5194/isprsannals-ii-5-w2-229-2013 · Cited by 20
Reel, P., Dooley, L., Wong, K. C. P., & Börner, A. (2013) · 2013 IEEE International Conference on Image Processing · doi:10.1109/icip.2013.6738293 · Cited by 20
“In medical imaging for example, images firstly need to be registered before image fusion can occur to facilitate disease diagnosis and treatment planning [3].”
BackgroundFusão 3D de imagens de MRI/CT e termografia
Sanches, I. J., Gamba, H. R., de Souza, M. A., Neves, E., & Nohama, P. (2013) · doi:10.4322/rbeb.2013.031 · Cited by 20
Image registration by normalized mapping
Wang, Q., Zou, C., Yuan, Y., Lu, H., & Yan, P. (2012) · Neurocomputing · doi:10.1016/j.neucom.2012.08.012 · Cited by 19
“The rigid registration is under the assumption that the interesting anatomical structures do not distort [14].”
BackgroundAffine image registration guided by particle filter
Arce-Santana, E., Campos-Delgado, D. U., & Alba, A. (2012) · IET Image Processing · doi:10.1049/iet-ipr.2011.0083 · Cited by 21
Böttger, T., Grunewald, K., Schöbinger, M., Fink, C., Risse, F., Kauczor, H.-U., Meinzer, H., & Wolf, I. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/5/004 · Cited by 20
Robust rigid registration of retinal angiograms through optimization
Dréo, J., Nunes, J.-C., & Siarry, P. (2006) · Comput. Medical Imaging Graph. · doi:10.1016/j.compmedimag.2006.07.004 · Cited by 20
“Registering method An overview of several registering algorithms can be found in [4,16,12].”
MethodIntrinsic Random Fields and Image Deformations
Mardia, K., Bookstein, F., Kent, J., & Meyer, C. (2006) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-006-7802-5 · Cited by 20
A Parallel Implementation of 2-D/3-D Image Registration for Computer-Assisted Surgery
Ino, F., Kawasaki, Y., Tashiro, T., Nakajima, Y., Sato, Y., Tamura, S., & Hagihara, K. (2006) · IEEE International Conference on Parallel and Distributed Systems (ICPADS) · doi:10.1109/icpads.2005.40 · Cited by 5
“Image registration (Hajnal et al., 2001) is a technique for finding point correspondences between two different images, usually taken at different times, from different viewing points, and/or in different modalities.”
BackgroundHigh-Performance Computing Service Over the Internet for Intraoperative Image Processing
Kawasaki, Y., Ino, F., Mizutani, Y., Fujimoto, N., Sasama, T., Sato, Y., Sugano, N., Tamura, S., & Hagihara, K. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.824740 · Cited by 19
Yilmaz, A., Sumer, E., & Temeltas, H. (2022) · Robotics Comput. Integr. Manuf. · doi:10.1016/j.rcim.2021.102302 · Cited by 20
Diffusion-Tensor Image Registration
Gee, J., & Alexander, D. (2006) · Visualization and Processing of Tensor Fields · doi:10.1007/3-540-31272-2_20 · Cited by 20
Cristoforetti, A., Stavola, L. D., Fincato, A., Masè, M., Ravelli, F., Nollo, G., & Tessarolo, F. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.103435 · Cited by 21
Remote Sensing Image Registration with Line Segments and Their Intersections
Lyu, C., & Jiang, J. (2017) · Remote Sensing · doi:10.3390/rs9050439 · Cited by 21
“These methods directly use the grayscale distribution information of an image in the registration task; they have been extensively used in the area of medical image registration [8].”
MethodGhaffari, A., & Fatemizadeh, E. (2015) · Signal Processing · doi:10.1016/j.sigpro.2014.10.022 · Cited by 19
“For example, brain magnetic resonance images (MRI) may often be corrupted by slow varying intensity bias fields [16]; or visual band images can have illumination nonhomogeneity and reflectance artifacts [17] and illumination variations in geometric images [18].”
BackgroundScan-Based Volume Animation Driven by Locally Adaptive Articulated Registrations
Rhee, T. J., Lewis, J. P., Neumann, U., & Nayak, K. S. (2010) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/tvcg.2010.39 · Cited by 17
Spatially weighted mutual information image registration for image guided radiation therapy
Park, S. B., Rhee, F. C.-H., Monroe, J. I., & Sohn, J. W. (2010) · Medical Physics · doi:10.1118/1.3463609 · Cited by 23
A flexible registration and evaluation engine (f.r.e.e.)
Floca, R. O., & Dickhaus, H. (2007) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2007.04.009 · Cited by 17
Sra, J., Narayan, G., Krum, D., & Akhtar, M. (2006) · Journal of interventional cardiac electrophysiology · doi:10.1007/s10840-006-9030-8 · Cited by 19
“The term image registration involves a process of aligning images [1, 2].”
BackgroundZarucco, L., Wisner, E., Swanstrom, M., & Stover, S. (2006) · Veterinary Radiology & Ultrasound · doi:10.1111/j.1740-8261.2006.00185.x · Cited by 19
Takao, M., Sugano, N., Nishii, T., Tanaka, H., Masumoto, J., Miki, H., Sato, Y., Tamura, S., & Yoshikawa, H. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.02.002 · Cited by 19
“Noise in MR scans is frequently not Gaussian, and there is also likely to have been change in the object being imaged between acquisitions [1].”
BackgroundMethodInfluentialImage registration in high-dimensional feature space
Neemuchwala, H., & Hero, A. (2005) · IS&T/SPIE Electronic Imaging · doi:10.1117/12.597635 · Cited by 19
Molecular imaging of the embryonic heart: Fables and facts on 3D imaging of gene expression patterns
Ruijter, J. M., Soufan, A. T., Hagoort, J., & Moorman, A. F. M. (2004) · Birth Defects Research Part C Embryo Today Reviews · doi:10.1002/bdrc.20018 · Cited by 17
Mori, S., Kobayashi, M., Kumagai, M., & Minohara, S. (2009) · Radiological Physics and Technology · doi:10.1007/s12194-008-0040-3 · Cited by 20
Image Registration for Breast Imaging: A Review
Guo, Y., Suri, J. S., & Sivaramakrishna, R. (2005) · 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference · doi:10.1109/iembs.2005.1617202 · Cited by 19
“Several survey papers have been published in the field of medical image registration [7][8][9][10].”
BackgroundAn efficient deep learning-based framework for image distortion correction
Li, S. K., Chu, Y., Zhao, Y., & Zhao, P. (2024) · The Visual Computer · doi:10.1007/s00371-024-03580-3 · Cited by 14
On Image Registration using The Radon Transform: Review-and-Improvement
Hjouj, F., & Jouini, M. S. (2021) · DMIP · doi:10.1145/3506651.3506654 · Cited by 18
“In this filed, Image registration involves correlating images from different temporal and spatial sources in order to ensure spatial consistency between given points in all images especially matching anatomical points and detailed information, for example [3-7].”
Luo, X., & Zhuang, X. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-59716-0_15 · Cited by 15
Lee, S., Shim, S., Ha, H.-G., Lee, H., & Hong, J. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2967802 · Cited by 25
Effects of abnormal muscle forces on prenatal joint morphogenesis in mice
Sotiriou, V., Rolfe, R. A., Murphy, P., & Nowlan, N. (2019) · bioRxiv · doi:10.1002/jor.24415 · Cited by 18
Zamyatin, D. A., Shchapova, Y. V., Votyakov, S. L., Nasdala, L., & Lenz, C. (2017) · Mineralogy and Petrology · doi:10.1007/s00710-017-0513-3 · Cited by 25
“Joint probability distribution analysis The joint analysis of images on a quantitative level is mathematically implemented using the JPD analysis method, which is widely used in various fields (Hajnal et al. 2001).”
MethodAn improved discontinuity-preserving image registration model and its fast algorithm
Zhang, J., Chen, K.-L., & Yu, B. (2016) · doi:10.1016/j.apm.2016.08.009 · Cited by 18
Kassab, G. S., An, G. C., Sander, E. A., Miga, M. I., Guccione, J. M., Ji, S., & Vodovotz, Y. (2016) · Annals of Biomedical Engineering · doi:10.1007/s10439-016-1596-4 · Cited by 20
Nonrigid point registration for 2D curves and 3D surfaces and its various applications
Wang, H., & Fei, B. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/12/4315 · Cited by 15
“Generally, the intensity-based deformable registration methods have a limited range of seeking transformation and thus typically require a rigid transformation in order to get two images roughly aligned in the preprocessing step (Hill et al., 2001; Pluim et al., 2003).”
MethodCurrent Status and Future Potential of Neural Networks Used for Medical Image Processing
Shi, Z., & He, L. (2011) · Journal of Multimedia · doi:10.4304/jmm.6.3.244-251 · Cited by 16
“In recent years, image processing techniques pose a far important role in the analysis of medical images in a wide range of modalities because of the reasons below[1]-[4].”
BackgroundMultiresolution Elastic Medical Image Registration in Standard Intensity Scale
Bagci, U., & Bai, L. (2009) · SIBGRAPI Conference on Graphics, Patterns and Images · doi:10.1109/sibgra.2007.4368198 · Cited by 18
“on is considered elastic(deformable) if the transformation is able to express both global and local deformations. For surveys of image registration including nonlinear medical image registration, see [20, 13, 12, 8, 18, 1, 14]. Although rigid and affine transformations are able to align images, they can only handle glo…”
2D XFEM-based modeling of retraction and successive resections for preoperative image update
Vigneron, L. M., Duflot, M., Robe, P. A. J. T., Warfield, S. K., & Verly, J. (2009) · Computer Aided Surgery · doi:10.3109/10929080903052677 · Cited by 19
“However, throughout surgery, the brain deforms, mostly as a result of the leakage of the cerebrospinal fluid out of the skull cavity, modifications in cerebral perfusion, pharmacological modulation of the extracellular fluid, and surgical acts, such as cuts, retractions, and resections [19,31,49].”
BackgroundConsistency of parametric registration in serial MRI studies of brain tumor progression
Mang, A., Schnabel, J., Crum, W., Modat, M., Camara-Rey, O., Palm, C., Caseiras, G. B., Jäger, H., Ourselin, S., Buzug, T., et al. (2008) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-008-0234-5 · Cited by 18
“[18,19] and references therein for further details).”
Self-citationMulti-modal Image Registration Using the Generalized Survival Exponential Entropy
Liao, S., & Chung, A. C. S. (2006) · International Conference on Medical Image Computing and Computer-Assisted Intervention · doi:10.1007/11866763_118 · Cited by 18
Utilization of Miniprobes in Modern Endoscopic Ultrasonography
Cysewska-Sobusiak, A., Skrzywanek, P., Sowier, A., & Cysewska, A. (2006) · IEEE Sensors Journal · doi:10.1109/jsen.2006.877985 · Cited by 18
Magnetic Resonance Image Analysis for Brain CAD Systems with Machine Learning
Arimura, H., Tokunaga, C., Yamashita, Y., & Kuwazuru, J. (2012) · Advances in bioinformatics and biomedical engineering book series · doi:10.4018/978-1-4666-0059-1.ch013 · Cited by 16
The information-theory analysis of Michaelis-Menten constants for detection of breast cancer.
Blokh, D., Stambler, I., Afrimzon, E., Shafran, Y., Korech, E., Sandbank, J., Orda, R., Zurgil, N., & Deutsch, M. (2007) · Cancer Detection and Prevention · doi:10.1016/j.cdp.2007.10.010 · Cited by 18
“In addition, the binarization approach allows the application of the Information Theory [32–34] which is most adequate for describing complex heterogeneous biological systems, mainly because it permits to establish non-linear correlations [23,35–37].”
MethodOse, T., Autio, J., Ohno, M., Frey, S., Uematsu, A., Kawasaki, A., Takeda, C., Hori, Y., Nishigori, K., Nakako, T., et al. (2022) · bioRxiv · doi:10.1101/2022.01.31.478477 · Cited by 17
“MBFR was effective for robust initialization, which has been often problematic in software‐based registration (Greve and Fischl, 2009; Hill et al., 2001).”
BackgroundEfficient Misalignment-Robust Multi-Focus Microscopical Images Fusion
Liang, Y., Mao, Y., Tang, Z., Yan, M., Zhao, Y.-Q., & Liu, J.-F. (2018) · Signal Processing · doi:10.1016/j.sigpro.2019.03.020 · Cited by 17
“Registration Model The feature-based registration [14] aims to set up a parametric transformation T that can relate the position (xs, ys) of features in the sensed image or coordinate space with the position (xr, yr) of the corresponding feature in the reference image or coordinate space.”
BackgroundMethodWang, H.-Y., Su, Z.-H., Xu, X., Sun, Z., Duan, F.-X., Song, Y.-Y., Li, L., Wang, Y.-W., Ma, X., Guo, A.-T., et al. (2016) · Scientific Reports · doi:10.1038/srep29146 · Cited by 17
Medical image registration using sparse coding of image patches
Afzali, M., Ghaffari, A., Fatemizadeh, E., & Soltanian-Zadeh, H. (2016) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2016.03.022 · Cited by 14
Elastic registration of prostate MR images based on estimation of deformation states
Marami, B., Sirouspour, S., Ghoul, S., Cepek, J., Davidson, S. R. H., Capson, D., Trachtenberg, J., & Fenster, A. (2015) · Medical Image Anal. · doi:10.1016/j.media.2014.12.007 · Cited by 17
Carminati, M. C., Maffessanti, F., & Caiani, E. G. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.12.013 · Cited by 21
Modeling tumor growth and treatment response based on quantitative imaging data
Yankeelov, T. E., Atuegwu, N. C., Deane, N. G., & Gore, J. C. (2010) · Integrative Biology · doi:10.1039/b921497f · Cited by 18
Volumetric Image Registration of Multi-modality Images of CT, MRI and PET
Li, G., & Miller, R. W. (2010) · doi:10.5772/8911 · Cited by 17
“So, the x-ray/γ-ray intensity from a particular anatomical site is directly related to the concentration of the radio-labelled molecular marker.”
BackgroundEvaluation of Four Volume-Based Image Registration Algorithms
Zhang, Y., Chu, J. C. H., Hsi, W. C., Khan, A. J., Mehta, P. S., Bernard, D. A., & Abrams, R. A. (2009) · Medical dosimetry · doi:10.1016/j.meddos.2008.12.004 · Cited by 14
Spatial accuracy of surgical robots
Haidegger, T., Kovács, L., Benyó, B., & Benyó, Z. (2009) · International Symposium on Applied Computational Intelligence and Informatics · doi:10.1109/saci.2009.5136227 · Cited by 17
Zeng, Q., & Chen, Y. (2008) · Springer eBooks · doi:10.1007/978-3-540-79450-9_28 · Cited by 17
Automatic hybrid registration for 2-dimensional CT abdominal images
Wang, X.-Y., & Feng, D. (2004) · International Conference on Image and Graphics · doi:10.1109/icig.2004.42 · Cited by 17
Nonrigid medical image registration technique as a composition of local warpings
Castellanos, N. P., del Angel, P. L., & Medina, V. (2004) · Pattern Recognition · doi:10.1016/j.patcog.2003.09.019 · Cited by 17
Thiele, H., Plein, S., Breeuwer, M., Ridgway, J., Higgins, D., Thorley, P., Schuler, G., & Sivananthan, M. (2004) · The International Journal of Cardiovascular Imaging · doi:10.1023/b:caim.0000041938.45383.a4 · Cited by 17
“In brief, image analysis consisted of six steps (Figure 1): (1) Automatic motion compensation by rigid registration [20].”
MethodRegistration of Organ Surface with Intra-operative 3D Ultrasound Image Using Genetic Algorithm
Wu, R.-Y., Ling, K., Shao, W., & Ng, W. (2003) · International Conference on Medical Image Computing and Computer-Assisted Intervention · doi:10.1007/978-3-540-39899-8_48 · Cited by 17
Non-rigid registration of cardiac MR: application to motion modelling and atlas-based segmentation
Rueckert, D., Lorenzo-Valdés, M., Chandrashekara, R., Sanchez-Ortiz, G. I., & Mohiaddin, R. (2002) · Proceedings IEEE International Symposium on Biomedical Imaging · doi:10.1109/isbi.2002.1029299 · Cited by 17
Keuschnigg, P., Kellner, D., Fritscher, K. D., Zechner, A., Mayer, U., Huber, P., Sedlmayer, F., Deutschmann, H., & Steininger, P. A. (2017) · Medical Physics · doi:10.1002/mp.12033 · Cited by 16
Coregistration of Structural and Functional Images
Hawkes, D., Hill, D., Hallpike, L., & Bailey, D. (2005) · doi:10.1007/1-84628-007-9_7 · Cited by 17
“Strictly, T defines a spatial mapping while we need a mapping that maps an accurate estimate of intensity, not just position, by including interpolation [2].”
BackgroundSelf-citationFree-breathing MRI techniques for fat and R2* quantification in the liver
Shih, S., & Wu, H. H. (2024) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-024-01187-2 · Cited by 17
“To achieve this within reasonable acquisition and processing time, some conventional image registration techniques that rely on image similarities, image brightness consistency or low-rank constraints have been used [106, 107].”
Effects of occlusal cavity configuration on 3D shrinkage vectors in a flowable composite
Kaisarly, D., Gezawi, M. E., Lai, G., Jin, J., Rösch, P., & Kunzelmann, K. (2017) · Clinical Oral Investigations · doi:10.1007/s00784-017-2304-y · Cited by 16
Jang, S.-W., Yoo, Y.-S., Lee, H., Kim, Y.-S., Srivastava, P., & Nair, A. (2015) · Arthroscopy: The Journal of Arthroscopy And Related · doi:10.1016/j.arthro.2015.04.082 · Cited by 16
Local interpolation schemes for landmark-based image registration: A comparison
Allasia, G., Cavoretto, R., & Rossi, A. D. (2014) · Mathematics and Computers in Simulation · doi:10.1016/j.matcom.2014.06.002 · Cited by 16
“ne. There is a large number of applications demanding image registration, including astronomy, biology, computer vision, genetics, physics, medicine, robotics, to name a few. For an overview,see e.g. [20, 21, 25, 26, 32, 34, 35, 36, 40, 42, 48] and referencestherein. In medicine, for example, registration is required…”
Automatic Detection of the Magnitude and Spatial Location of Error in Non-rigid Registration
Datteri, R., & Dawant, B. (2012) · Workshop on Biomedical Image Registration · doi:10.1007/978-3-642-31340-0_3 · Cited by 16
Computer and Robot-Assisted Medical Intervention
Troccaz, J. (2009) · Handbook of Automation · doi:10.1007/978-3-540-78831-7_82 · Cited by 16
“ge is data fusion, also called registration, which corresponds to the action of representing all the information in a single reference frame. Registration and in particular medical image registration [2], has been a very active domain for three decades. From this integrated model, the medical action can be planned: fo…”
BackgroundFemur statistical atlas construction based on two-level 3D non-rigid registration
Wu, C., Murtha, P. E., & Jaramaz, B. (2009) · Computer Aided Surgery · doi:10.3109/10929080903246543 · Cited by 16
“It has numerous clinical applications such as statistical atlas construction for group study and statistical parameters analysis [15, 16], mapping anatomical atlases to individual patient images for disease analysis [17, 18, 19] and image segmentation [20, 21].”
Mosaliganti, K. R., Pan, T., Ridgway, R., Sharp, R., Cooper, L. A. D., Gulacy, A., Sharma, A., Irfanoglu, M., Machiraju, R., Kurç, T., et al. (2008) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2008.03.013 · Cited by 16
Ceylan, C., van der Heide, U. A., Bol, G. H., Lagendijk, J., & Kotte, A. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/10/n01 · Cited by 16
“The algorithms for 3D image registration can be divided into groups that utilize corresponding-points registration, surface matching and voxel intensity registration (Hill et al 2001).”
Method
Metadata
- Authors
- Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J.
- Affiliations
- Guy's Hospital (GB)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2001-02-15
- Volume
- 46
- Issue
- 3
- Pages
- R1-R45
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2140139548
- Cited by
- 2,093
- References
- 127
- Citations by year
- 2026: 19 · 2025: 21 · 2024: 40 · 2023: 47 · 2022: 45 · 2021: 44 · 2020: 53 · 2019: 57 · 2018: 66 · 2017: 89 · 2016: 69 · 2015: 100 · 2014: 104 · 2013: 124 · 2012: 105
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Research Portal (King's College London) (submittedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Keywords
- medical image registration, multimodal image fusion, motion compensation, image-guided interventions, rigid transformation, non-rigid registration, tissue deformation, temporal image sequences
- MeSH terms
- Algorithms, Diagnostic Imaging, Humans, Image Processing, Computer-Assisted, Registries, Research
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.