Medical image registration
The DOI matches its Crossref record; 123 of the 123 references it cites were found in a registry or an index.
Abstract
Radiological images are increasingly being used in healthcare and medical research. There is, consequently, widespread interest in accurately relating information in the different images for diagnosis, treatment and basic science. This article reviews registration techniques used to solve this problem, and describes the wide variety of applications to which these techniques are applied. Applications of image registration include combining images of the same subject from different modalities, aligning temporal sequences of images to compensate for motion of the subject between scans, image guidance during interventions and aligning images from multiple subjects in cohort studies. Current registration algorithms can, in many cases, automatically register images that are related by a rigid body transformation (i.e. where tissue deformation can be ignored). There has also been substantial progress in non-rigid registration algorithms that can compensate for tissue deformation, or align images from different subjects. Nevertheless many registration problems remain unsolved, and this is likely to continue to be an active field of research in the future.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“General approaches address multimodal image registration by either performing image synthesis [22, 23] to change the problem to a uni-modal image registration task, or by proposing complex, hand-crafted [24, 25, 26, 27] or learned [28, 29, 30, 31, 32] multi-modal image similarity measures.”
From Quicksilver: Fast predictive image registration – A deep learning approach (2017) · cites this paper as [29]
Citations
Cites
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
A method for registration of 3-D shapes
Besl, P. J., & McKay, N. D. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121791 · Cited by 18,103
Co-Planar Stereotaxic Atlas of the Human Brain
Talairach, J., & Tournoux, P. (1988) · Medical Entomology and Zoology · Cited by 11,798
Communication in the presence of noise
Shannon, C. E. (1949) · Proceedings of the IRE · doi:10.1109/jrproc.1949.232969 · Cited by 6,539
Golub, G. H., & Loan, C. F. V. (1996) · Johns Hopkins University Press eBooks · Cited by 6,027
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Self-citationPrincipal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
Communication In The Presence Of Noise
Shannon, C. E. (1998) · Proceedings of the IEEE · doi:10.1109/jproc.1998.659497 · Cited by 4,804
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Research works printed but not linked: 7
- 10.1016/S1361-8415(96)80006-5 · doi:10.1016/s1361-8415(96)80006-5
- 10.1002/(SICI)1522-712X(1995)1:4<198::AID-IGS2>3.0.CO;2-5 · doi:10.1002/(sici)1522-712x(1995)1:4<198::aid-igs2>3.0.co;2-5
- 10.1002/(SICI)1522-2594(200004)43:4<583::AID-MRM13>3.0.CO;2-B · doi:10.1002/(sici)1522-2594(200004)43:4<583::aid-mrm13>3.0.co;2-b
- Press W H, 1992
- Sibson R, 1978, J. R. Statist. Soc., 40, 234
- 10.1002/(SICI)1522-2586(199910)10:4<582::AID-JMRI12>3.0.CO;2-X · doi:10.1002/(sici)1522-2586(199910)10:4<582::aid-jmri12>3.0.co;2-x
- 10.1016/S1361-8415(96)80004-1 · doi:10.1016/s1361-8415(96)80004-1
Cited by
Items 101–200 of 1,032
Software for image registration: Algorithms, accuracy, efficacy
Hutton, B. F., & Braun, M. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127309 · Cited by 145
Verhey, J., Wisser, J., Warfield, S., Rexilius, J., & Kikinis, R. (2005) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-4-19 · Cited by 136
“We carried out a visual assessment of the accuracy of the registration and assumed the error for each modality to be of the order of half a voxel size in our case [34].”
MethodLearning from Demonstrations Through the Use of Non-rigid Registration
Schulman, J., Ho, J., Lee, C., & Abbeel, P. (2016) · Springer Tracts in Advanced Robotics · doi:10.1007/978-3-319-28872-7_20 · Cited by 133
MRI Superresolution Using Self‐Similarity and Image Priors
Manjón, J. V., Coupé, P., Buades, A., Collins, D. L., & Robles, M. (2010) · International Journal of Biomedical Imaging · doi:10.1155/2010/425891 · Cited by 121
Multimodal Registration via Mutual Information Incorporating Geometric and Spatial Context
Woo, J., Stone, M., & Prince, J. L. (2014) · IEEE Transactions on Image Processing · doi:10.1109/tip.2014.2387019 · Cited by 151
Registration of Multiview Real-Time 3-D Echocardiographic Sequences
Grau, V., Becher, H. H., & Noble, J. A. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.903568 · Cited by 137
Deformable Registration for Dose Accumulation
Chetty, I. J., & Rosu‐Bubulac, M. (2019) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2019.02.002 · Cited by 153
Application of soft tissue modelling to image-guided surgery
Carter, T. J., Maxime Sermesant, B., Cash, D. M., Barratt, D. C., Tanner, C., & Hawkes, D. J. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.10.005 · Cited by 121
“Other techniques which have been developed include passive articulated arms [6,7] and electromagnetic tracking [8–11].”
MethodSelf-citationTsai, C.-L., Li, C.-Y., Yang, G., & Lin, K.-S. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2030324 · Cited by 116
“Image registration is a fundamental component in automatic image analysis, and it is playing an increasingly important role in the medical imaging domain [16], [23], [27], [40], where accurate alignment of intra- and inter-modality images is required for integration of information.”
BackgroundABSORB: Atlas Building by Self-Organized Registration and Bundling
Jia, H., Wu, G.-R., Wang, Q., & Shen, D. (2010) · 2010 IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2010.5540007 · Cited by 127
“Accordingly, many groupwise registration methods have been recently proposed to achieve more accurate and consistent registration among the population by simultaneously registering all images within a single registration framework, thus facilitating the better investigation of the group similarity and variation in the…”
BackgroundMethodThe Role of Registration in Accurate Surgical Guidance
Fitzpatrick, J. (2010) · Proceedings of the Institution of mechanical engineers. Part H, journal of engineering in medicine · doi:10.1243/09544119jeim589 · Cited by 123
Current ICRU definitions of volumes: limitations and future directions.
Purdy, J. (2004) · Seminars in Radiation Oncology · doi:10.1053/j.semradonc.2003.12.002 · Cited by 121
Multimodality image registration with software: state-of-the-art
Slomka, P. J., & Baum, R. P. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0941-8 · Cited by 118
User-friendly software for the analysis of brain lesions (ABLe)
Solomon, J. M., Raymont, V., Braun, A. R., Butman, J. A., & Grafman, J. H. (2007) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2007.02.006 · Cited by 119
“[13], the most practical method of estimating registration accuracy for a single patient may be to visually inspect the images.”
MethodRogelj, P., & Kovacic, S. (2003) · SPIE Medical Imaging · doi:10.1117/12.480122 · Cited by 120
Micro computed tomography for vascular exploration
Zagorchev, L., Oses, P., Zhuang, Z. W., Moodie, K. L., Mulligan‐Kehoe, M. J., Simons, M., & Couffinhal, T. (2010) · Vascular Cell · doi:10.1186/2040-2384-2-7 · Cited by 140
“Image registration computes a transformation or a deformation field that can be applied to one volume to align with another [14-18].”
Real-time Deep Pose Estimation with Geodesic Loss for Image-to-Template Rigid Registration
Salehi, S. S. M., Khan, S., Erdogmus, D., & Gholipour, A. (2018) · arXiv · doi:10.48550/arxiv.1803.05982 · Cited by 118
Inverse-Consistent Deep Networks for Unsupervised Deformable Image RegistrationPreprint
Zhang, J. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1809.03443 · Cited by 157
“arison of anatomical structures across scans, and thus, is crucial for understanding variability across populations and the longitudinal evolution of brain anatomy for individuals with brain diseases [4]–[6]. Over the past few decades, a variety of non-learningbased deformable registration methods have been proposed f…”
MethodSimultaneous multi-modality ROI delineation in clinical practice
Bol, G. H., Kotte, A. N. T. J., van der Heide, U. A., & Lagendijk, J. J. W. (2009) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.04.008 · Cited by 101
Medical image registration in image guided surgery: Issues, challenges and research opportunities
Alam, F., Rahman, S. U., Ullah, S., & Gulati, K. (2017) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2017.10.001 · Cited by 138
Non-rigid registration using free-form deformations
Rueckert, D., & Aljabar, P. (2015) · Springer eBooks · doi:10.1007/978-0-387-09749-7_15 · Cited by 97
“Comprehensive reviews of image registration techniques can be found in [31, 44, 66].”
BackgroundEvaluation of various deformable image registration algorithms for thoracic images
Kadoya, N., Fujita, Y., Katsuta, Y., Dobashi, S., Takeda, K., Kishi, K., Kubozono, M., Umezawa, R., Sugawara, T., Matsushita, H., et al. (2013) · Journal of Radiation Research · doi:10.1093/jrr/rrt093 · Cited by 115
Fast Deformable Registration on the GPU: A CUDA Implementation of Demons
Muyan-Ozcelik, P., Owens, J. D., Xia, J., & Samant, S. S. (2008) · 2008 International Conference on Computational Sciences and Its Applications · doi:10.1109/iccsa.2008.22 · Cited by 115
Contact surface and material nonlinearity modeling of human lungs
Al-Mayah, A., Moseley, J., & Brock, K. K. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/1/022 · Cited by 112
Bhushan, C., Haldar, J. P., Choi, S., Joshi, A. A., Shattuck, D. W., & Leahy, R. M. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.03.050 · Cited by 119
“The choice of dissimilarity measure D(·) is crucial for accurate registration of the images and it is desirable that D(·) be sensitive to slight differences in alignment between the images.”
BackgroundMethodInfluentialKirişli, H. A., Schaap, M., Klein, S., Papadopoulou, S., Bonardi, M., Chen, C. H., Weustink, A. C., Mollet, N. R., Vonken, E.-J. P. A., van der Geest, R. J., et al. (2010) · Medical Physics · doi:10.1118/1.3512795 · Cited by 113
Automatic registration of optical imagery with 3D LiDAR data using statistical similarity
Parmehr, E. G., Fraser, C. S., Chunsun Zhang, A., & Leach, J. (2013) · ISPRS Journal of Photogrammetry and Remote Sensing · doi:10.1016/j.isprsjprs.2013.11.015 · Cited by 103
A method of image registration for small animal, multi-modality imaging
Chow, P. L., Stout, D. B., Komisopoulou, E., & Chatziioannou, A. F. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/2/013 · Cited by 100
“A number of sophisticated software techniques to register sets of related intra- and intermodality images have been developed (Hill et al 2001).”
MethodSykes, J., Amer, A., Czajka, J., & Moore, C. (2005) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2005.05.005 · Cited by 108
Douglas, T. S. (2004) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2004.06.002 · Cited by 111
“[64] Hill DLG, Batchelor PG, Holden M, Hawkes DJ.”
BackgroundAutomatic MR volume registration and its evaluation for the pelvis and prostate
Fei, B., Wheaton, A. J., Lee, Z., Duerk, J. L., & Wilson, D. L. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/5/309 · Cited by 101
“Many reports describe methods and evaluations for registration in the brain (Hill et al 2001); far fewer describe results for the pelvis or prostate.”
BackgroundImaging and machine learning techniques for diagnosis of Alzheimer’s disease
Mirzaei, G., Adeli, A., & Adeli, H. (2016) · Reviews in the Neurosciences · doi:10.1515/revneuro-2016-0029 · Cited by 138
“With advances in registration techniques (Maintz and Viergever, 1998; Lester and Arridge, 1999; Hill et al., 2001; Pluim et al., 2003), more qualified segmented images can be obtained.”
MethodBlackall, J. M., Penney, G., King, A. P., & Hawkes, D. J. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.856751 · Cited by 99
Self-citation3D volume reconstruction of a mouse brain from histological sections using warp filtering
Ju, T., Warren, J. D., Carson, J. P., Bello, M. O., Kakadiaris, I. A., Chiu, W., Christina Thaller, B., & Gregor Eichele, C. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.02.020 · Cited by 95
The Image-Guided Surgery Toolkit IGSTK: An Open Source C++ Software Toolkit
Cheng, P., Ibáñez, L., Gobbi, D., Gary, K., Aylward, S., Jomier, J., Enquobahrie, A., Zhang, H., Kim, H.-S., Blake, M., et al. (2007) · SPIE Medical Imaging · doi:10.1007/s10278-007-9054-3 · Cited by 101
Differential Evolution as a viable tool for satellite image registration
Falco, I. D., Cioppa, A. D., Maisto, D., & Tarantino, E. (2007) · Applied Soft Computing · doi:10.1016/j.asoc.2007.10.013 · Cited by 97
Towards a model of lung biomechanics: pulmonary kinematics via registration of serial lung images
Sundaram, T. A., & Gee, J. C. (2005) · Medical Image Analysis · doi:10.1016/j.media.2005.04.002 · Cited by 88
Multimodal Medical Image Fusion Using Redundant Discrete Wavelet Transform
Singh, R., Mayank Vatsa, A., & Afzel Noore, B. (2009) · International Conference on Advances in Pattern Recognition · doi:10.1109/icapr.2009.97 · Cited by 85
Piecewise affine registration of biological images for volume reconstruction
Pitiot, A., Bardinet, É., Thompson, P. M., & Malandain, G. (2005) · Medical Image Analysis · doi:10.1016/j.media.2005.03.008 · Cited by 100
Selective image similarity measure for bronchoscope tracking based on image registration
Deguchi, D., Mori, K., Feuerstein, M., Kitasaka, T., Maurer, C. R., Suenaga, Y., Takabatake, H., Mori, M., & Natori, H. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.06.001 · Cited by 102
Manifold learning for image-based breathing gating in ultrasound and MRI
Wachinger, C., Yiğitsoy, M., Rijkhorst, E., & Navab, N. (2012) · Medical Image Anal. · doi:10.1016/j.media.2011.11.008 · Cited by 96
A data distributed parallel algorithm for nonrigid image registration
Ino, F., Ooyama, K., & Hagihara, K. (2005) · Parallel Computing · doi:10.1016/j.parco.2004.12.001 · Cited by 76
A rigidity penalty term for nonrigid registration
Staring, M., Klein, S., & Pluim, J. P. W. (2007) · Medical Physics · doi:10.1118/1.2776236 · Cited by 171
Nissen, E., Krishnan, A. K., Arrowsmith, J., & Saripalli, S. (2012) · Geophysical Research Letters · doi:10.1029/2012gl052460 · Cited by 92
“…RESEARCH LETTERS, VOL. 39, L16301, doi:10.1029/2012GL052460, 2012 L16301 1 of 6 images which is widely used in medicine as a way of aligning and comparing multi-temporal scans of a subject’s body [e.g., Hill et al., 2001] as well as in computer graphics [e.g., Levoy et al., 2000].”
MethodInfluentialVerhulp, E. E., van Rietbergen, B., Müller, R., & Huiskes, R. (2008) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840701848756 · Cited by 79
Face recognition from 2D and 3D images using 3D Gabor filters
Wang, Y., & Chua, C.-S. (2005) · Image and Vision Computing · doi:10.1016/j.imavis.2005.07.005 · Cited by 81
Feature and Intensity Based Medical Image Registration Using Particle Swarm Optimization
Abdel‐Basset, M., Fakhry, A. E., Elhenawy, I., Qiu, T., & Sangaiah, A. K. (2017) · Journal of Medical Systems · doi:10.1007/s10916-017-0846-9 · Cited by 103
High Resolution Cerebral Blood Flow Imaging by Registered Laser Speckle Contrast Analysis
Miao, P., Rege, A., Li, N., Thakor, N. V., & Tong, S. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2037434 · Cited by 88
Grover, V. P. B., Dresner, M.-A., Forton, D.-M., Counsell, S. J., Larkman, D.-J., Patel, N., Thomas, H.-C., & Taylor-Robinson, S.-D. (2006) · World Journal of Gastroenterology · doi:10.3748/wjg.v12.i19.2969 · Cited by 74
Sub-pixel registration and estimation of local shifts directly in the fourier domain
Foroosh, H., & Balci, M. (2005) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2004.1421453 · Cited by 35
A Systematic Review on Orthopedic Simulators for Psycho-Motor Skill and Surgical Procedure Training
Ruikar, D. D., Hegadi, R. S., & Santosh, K. (2018) · Journal of Medical Systems · doi:10.1007/s10916-018-1019-1 · Cited by 100
3D nonrigid registration via optimal mass transport on the GPU
Rehman, T. U., Haber, E., Pryor, G., Melonakos, J., & Tannenbaum, A. (2008) · Medical Image Analysis · doi:10.1016/j.media.2008.10.008 · Cited by 82
Astroalign: A Python module for astronomical image registration
Beroiz, M., Cabral, J., & Sánchez, B. (2020) · Astronomy and Computing · doi:10.1016/j.ascom.2020.100384 · Cited by 125
Real-time multi-modal rigid registration based on a novel symmetric-SIFT descriptor
Chen, J., & Tian, J. (2009) · Progress in Natural Science Materials International · doi:10.1016/j.pnsc.2008.06.029 · Cited by 80
“The purpose of image registration is to spatially align two or more single-modality images taken at different times, or several images acquired by multiple imaging modalities [1–5].”
BackgroundMulti-classifier framework for atlas-based image segmentation
Rohlfing, T., & Maurer, C. R. (2005) · Pattern Recognition Letters · doi:10.1016/j.patrec.2005.03.017 · Cited by 80
Non-rigid Image Registration Using Graph-cuts
Tang, T. W. H., & Chung, A. C. S. (2007) · Springer eBooks · doi:10.1007/978-3-540-75757-3_111 · Cited by 85
Dynamic 3D Ultrasound and MR Image Registration of the Beating Heart
Huang, X., Hill, N., Ren, J., Guiraudon, G., Boughner, D., & Peters, T. (2005) · International Conference on Medical Image Computing and Computer-Assisted Intervention · doi:10.1007/11566489_22 · Cited by 80
Providing Integrity and Authenticity in DICOM Images: A Novel Approach
Kobayashi, L. O. M., Furuie, S., & Barreto, P. L. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2014751 · Cited by 79
A deformable image registration method to handle distended rectums in prostate cancer radiotherapy
Gao, S., Zhang, L., Wang, H., de Crevoisier, R., Kuban, D., Mohan, R., & Dong, L. (2006) · Medical Physics · doi:10.1118/1.2222077 · Cited by 73
Nonrigid Registration of Medical Images: Theory, Methods, and Applications [Applications Corner
Rueckert, D., & Aljabar, P. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2010.936850 · Cited by 70
3D kinematic analysis of the acromioclavicular joint during arm abduction using vertically open MRI
Sahara, W., Sugamoto, K., Murai, M., Tanaka, H., & Yoshikawa, H. (2006) · Journal of Orthopaedic Research · doi:10.1002/jor.20208 · Cited by 78
AIRNet: Self-Supervised Affine Registration for 3D Medical Images using Neural NetworksPreprint
Chee, E. Y. L., & Wu, Z. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1810.02583 · Cited by 93
Polymerization composite shrinkage evaluation with 3D deformation analysis from μCT images
Chiang, Y., Rösch, P., Dabanoğlu, A., Lin, C., Hickel, R., & Kunzelmann, K. (2009) · Dental Materials · doi:10.1016/j.dental.2009.09.013 · Cited by 91
Lu, C., Chelikani, S., Papademetris, X., Knisely, J. P. S., Milosevic, M., Chen, Z., Jaffray, D. A., Staib, L. H., & Duncan, J. S. (2011) · Medical Image Analysis · doi:10.1016/j.media.2011.05.010 · Cited by 81
“An alternative voxel-based similarity measure is normalized cross-correlation (NCC) which has been shown to accurately and robustly align intermodality images (Hill et al. (2001); Holden et al. (2000)).”
BackgroundUsing Spanning Graphs for Efficient Image Registration
Sabuncu, M. R., & Ramadge, P. J. (2008) · IEEE Transactions on Image Processing · doi:10.1109/tip.2008.918951 · Cited by 71
Principles and Applications of Computer Graphics in Medicine
Vidal, F. P., Bello, F., Brodlie, K., John, N. W., Gould, D., Phillips, R., & Avis, N. J. (2006) · Computer Graphics Forum · doi:10.1111/j.1467-8659.2006.00822.x · Cited by 75
“This has been attributed to the general difficulty in controlling the geometry of image acquisition [64].”
BackgroundMethodInfluentialDean, C. J., Sykes, J., Cooper, R., Hatfield, P., Carey, B., Swift, S. E., Bacon, S. E., Thwaites, D., Sebag‐Montefiore, D., & Morgan, A. M. (2011) · British Journal of Radiology · doi:10.1259/bjr/11855927 · Cited by 79
“The automated systems offered by OMP and CMS both use mutual information (MI) that seeks solutions with a low joint entropy and high marginal entropies [20].”
BackgroundMethodMultimodal Data Fusion Based on Mutual Information
Bramon, R., Boada, I., Bardera, A., Rodriguez, J., Feixas, M., Puig, J., & Sbert, M. (2011) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/tvcg.2011.280 · Cited by 86
EVolution: an edge-based variational method for non-rigid multi-modal image registration
de Senneville, B. D., Zachiu, C., Ries, M. G., & MOONEN, C. T. W. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/20/7377 · Cited by 86
“A variety of each has already been proposed in the medical image processing literature (Hill et al 2001).”
Salas-Gonzalez, D., Górriz, J. M., Ramírez, J., López, M., Álvarez, I., Segovia, F., Chaves, R., & Puntonet, C. G. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/10/002 · Cited by 57
“In this work, the images have been normalized using a general affine model, with 12 parameters (Hill et al 2001, Salas-Gonzalez et al 2008, Woods et al 1998).”
MethodSurvey of Non-Rigid Registration Tools in Medicine
Keszei, A. P., Berkels, B., & Deserno, T. M. (2016) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-016-9915-8 · Cited by 88
The Integration of Positron Emission Tomography With Magnetic Resonance Imaging
Cherry, S., Louie, A., & Jacobs, R. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2007.913502 · Cited by 72
Cooper, L., Sertel, O., Kong, J., Lozanski, G., Huang, K., & Gürcan, M. N. (2009) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.04.012 · Cited by 70
Sahara, W., Sugamoto, K., Murai, M., Tanaka, H., & Yoshikawa, H. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.04.012 · Cited by 71
“Voxel-based registration is a method for superimposing a 3D image on another image by minimizing the sum of squared intensity differences for segmented voxels (Hill et al., 2001).”
BackgroundMethodA method for generating patient-specific finite element meshes for head modelling
Gibson, A. P., Riley, J., Schweiger, M. J., Hebden, J. C., Arridge, S., & Delpy, D. T. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/4/305 · Cited by 63
“This approach is similar to medical image registration, where an entire 2D or 3D image is warped to fit another image or dense set of points (Hill et al 2001).”
Computing Accurate Correspondences across Groups of Images
Cootes, T. F., Twining, C. J., Petrovic, V. S., Babalola, K. O., & Taylor, C. J. (2010) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2009.193 · Cited by 70
Combined edge detection using wavelet transform and signal registration
Heric, D., & Zazula, D. (2006) · Image and Vision Computing · doi:10.1016/j.imavis.2006.05.008 · Cited by 67
Survey of using GPU CUDA programming model in medical image analysis
Kalaiselvi, T., Sriramakrishnan, P., & Somasundaram, K. (2017) · Informatics in Medicine Unlocked · doi:10.1016/j.imu.2017.08.001 · Cited by 82
State-of-the-Art Medical Image Registration Methodologies: A Survey
Khalifa, F., Beache, G. M., Gimel’farb, G., Suri, J. S., & El-Baz, A. S. (2011) · Springer eBooks · doi:10.1007/978-1-4419-8195-0_9 · Cited by 70
“, if serial magnetic resonance imaging (MRI) scans of a particular patient, acquired over different time intervals, are to be compared in order to follow disease progression, response to treatment, or even dynamic structural change patterns of organ development [1].”
BackgroundThe Clinical Role of Fusion Imaging Using PET, CT, and MR Imaging
Zaidi, H., Montandon, M., & Alavi, A. A. (2008) · PET Clinics · doi:10.1016/j.cpet.2009.03.002 · Cited by 31
Boyd, S. K., Moser, S., Kuhn, M. H., Klinck, R. J., Krauze, P. L., Müller, R., & Gasser, J. A. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9168-7 · Cited by 69
Humm, J. L., Ballon, D., Hu, Y., Ruan, S., Chui, C. S., Tulipano, P. K., Erdi, A. K., Koutcher, J. A., Zakian, K. L., Urano, M., et al. (2003) · Medical Physics · doi:10.1118/1.1600738 · Cited by 55
Multimodal Image Registration for Preoperative Planning and Image-Guided Neurosurgical Procedures
Risholm, P., Golby, A. J., & Wells, W. M. (2011) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2010.12.001 · Cited by 70
Scientific Data Mining - A Practical Perspective
Kamath, C. (2009) · doi:10.1137/1.9780898717693 · Cited by 65
“The solutions to these can be found in several survey papers [423, 406, 195] as well as in several chapters in the Handbook of Medical Imaging, edited by Bankman [20], and the books by Modersitzki [433] and Hajnal, Hill, and Hawkes [238].”
BackgroundRetrospective evaluation of a topology preserving non-rigid registration method
Noblet, V., Heinrich, C., Heitz, F., & Armspach, J. (2006) · Medical Image Analysis · doi:10.1016/j.media.2006.01.001 · Cited by 59
“For a state of the art of registration methods, the reader will refer to (Brown, 1992; Zitova and Flusser, 2003) and more particularly to (Maintz and Viergever, 1998; Lester and Arridge, 1999; Hajnal et al., 2001) for medical image registration.”
MethodChi, Y., Liang, J., & Yan, D. (2006) · Medical Physics · doi:10.1118/1.2163838 · Cited by 59
Hybrid analysis for indicating patients with breast cancer using temperature time series
Silva, L., dos Santos, A. A. S., Bravo, R. S., Silva, A. C., Muchaluat-Saade, D., & Conci, A. (2016) · Comput. Methods Programs Biomed. · doi:10.1016/j.cmpb.2016.03.002 · Cited by 64
Weight Preserving Image Registration for Monitoring Disease Progression in Lung CT
Gorbunova, V., Lo, P., Ashraf, H., Dirksen, A., Nielsen, M., & de Bruijne, M. (2008) · International Conference on Medical Image Computing and Computer-Assisted Intervention · doi:10.1007/978-3-540-85990-1_104 · Cited by 64
“For intra-subject registration of medical images of the same modality the mean sum of squared distances is a suitable similarity measure [9, 10], given in the form”
MethodB-spline registration of 3D images with Levenberg-Marquardt optimization
Kabus, S., Netsch, T., Fischer, B., & Modersitzki, J. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.533976 · Cited by 64
Limited-data image registration for radiotherapy positioning and verification
Ruchala, K., Olivera, G., & Kapatoes, J. M. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02895-x · Cited by 62
Rougon, N. F., Petitjean, C., Preteux, F. J., Cluzel, P., & Greniér, P. (2005) · Medical Image Analysis · doi:10.1016/j.media.2005.01.005 · Cited by 58
Quantitative MRI Biomarkers of Stereotactic Radiotherapy Outcome in Brain Metastasis
Karami, E., Soliman, H., Ruschin, M., Sahgal, A., Myrehaug, S. D., Tseng, C., Czarnota, G. J., Maralani, P. J., Chugh, B. P., Lau, A. Z., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-56185-5 · Cited by 77
“Elham Karami((1,2,3)), Hany Soliman((4,5)), Mark Ruschin((4,5)), Arjun Sahgal((4,5)), Sten Myrehaug((4,5)), Chia-Lin Tseng((4,5)), Gregory J.”
BackgroundDrift estimation for single marker switching based imaging schemes
Geisler, C., Hotz, T., Schönle, A., Hell, S. W., Munk, A., & Egner, A. (2012) · Optics Express · doi:10.1364/oe.20.007274 · Cited by 71
The mixtures of Student’s t-distributions as a robust framework for rigid registration
Gerogiannis, D. P., Nikou, C., & Likas, A. C. (2008) · Image and Vision Computing · doi:10.1016/j.imavis.2008.11.013 · Cited by 56
Rapid registration for wide field of view freehand three-dimensional ultrasound
Gee, A. H., Treece, G. M., Prager, R. W., Cash, C. J. C., & Berman, L. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.819279 · Cited by 53
“There is a lot of literature on medical image registration (see [5] and [6] for recent reviews), but very little of it concerns 3-D US, which differs from the other modalities in three important ways: the often irregular sampling of space by the acquisition protocol, the way the anatomy’s appearance depends on the dir…”
BackgroundPiecewise Affine Registration of Biological Images
Pitiot, A., Malandain, G., Bardinet, É., & Thompson, P. M. (2003) · Lecture notes in computer science · doi:10.1007/978-3-540-39701-4_10 · Cited by 43
End-to-end multimodal image registration via reinforcement learning
Hu, J., Luo, Z., Wang, X., Sun, S., Yin, Y., Cao, K., Song, Q., Lyu, S., & Wu, X. (2020) · Medical Image Analysis · doi:10.1016/j.media.2020.101878 · Cited by 76
Glocker, B., Komodakis, N., Paragios, N., Tziritas, G., & Navab, N. (2007) · Lecture notes in computer science · doi:10.1007/978-3-540-73273-0_34 · Cited by 61
Rigid pairwise 3D point cloud registration: A survey
Lyu, M., Yang, J., Qi, Z., Xu, R., & Liu, J. (2024) · Pattern Recognition · doi:10.1016/j.patcog.2024.110408 · Cited by 73
Linte, C. A., Davenport, K. P., Cleary, K., Peters, C. A., Vosburgh, K. G., Navab, N., Edwards, P., Jannin, P., Peters, T. M., Holmes, D. R., et al. (2013) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2012.12.002 · Cited by 59
Metadata
- Authors
- Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J.
- Affiliations
- Guy's Hospital (GB)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2001-02-15
- Volume
- 46
- Issue
- 3
- Pages
- R1-R45
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2140139548
- Cited by
- 2,093
- References
- 127
- Citations by year
- 2026: 19 · 2025: 21 · 2024: 40 · 2023: 47 · 2022: 45 · 2021: 44 · 2020: 53 · 2019: 57 · 2018: 66 · 2017: 89 · 2016: 69 · 2015: 100 · 2014: 104 · 2013: 124 · 2012: 105
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Research Portal (King's College London) (submittedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Keywords
- medical image registration, multimodal image fusion, motion compensation, image-guided interventions, rigid transformation, non-rigid registration, tissue deformation, temporal image sequences
- MeSH terms
- Algorithms, Diagnostic Imaging, Humans, Image Processing, Computer-Assisted, Registries, Research
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.