Medical image registration
The DOI matches its Crossref record; 123 of the 123 references it cites were found in a registry or an index.
Abstract
Radiological images are increasingly being used in healthcare and medical research. There is, consequently, widespread interest in accurately relating information in the different images for diagnosis, treatment and basic science. This article reviews registration techniques used to solve this problem, and describes the wide variety of applications to which these techniques are applied. Applications of image registration include combining images of the same subject from different modalities, aligning temporal sequences of images to compensate for motion of the subject between scans, image guidance during interventions and aligning images from multiple subjects in cohort studies. Current registration algorithms can, in many cases, automatically register images that are related by a rigid body transformation (i.e. where tissue deformation can be ignored). There has also been substantial progress in non-rigid registration algorithms that can compensate for tissue deformation, or align images from different subjects. Nevertheless many registration problems remain unsolved, and this is likely to continue to be an active field of research in the future.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“General approaches address multimodal image registration by either performing image synthesis [22, 23] to change the problem to a uni-modal image registration task, or by proposing complex, hand-crafted [24, 25, 26, 27] or learned [28, 29, 30, 31, 32] multi-modal image similarity measures.”
From Quicksilver: Fast predictive image registration – A deep learning approach (2017) · cites this paper as [29]
Citations
Cites
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
A method for registration of 3-D shapes
Besl, P. J., & McKay, N. D. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121791 · Cited by 18,103
Co-Planar Stereotaxic Atlas of the Human Brain
Talairach, J., & Tournoux, P. (1988) · Medical Entomology and Zoology · Cited by 11,798
Communication in the presence of noise
Shannon, C. E. (1949) · Proceedings of the IRE · doi:10.1109/jrproc.1949.232969 · Cited by 6,539
Golub, G. H., & Loan, C. F. V. (1996) · Johns Hopkins University Press eBooks · Cited by 6,027
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Self-citationPrincipal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
Communication In The Presence Of Noise
Shannon, C. E. (1998) · Proceedings of the IEEE · doi:10.1109/jproc.1998.659497 · Cited by 4,804
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Research works printed but not linked: 7
- 10.1016/S1361-8415(96)80006-5 · doi:10.1016/s1361-8415(96)80006-5
- 10.1002/(SICI)1522-712X(1995)1:4<198::AID-IGS2>3.0.CO;2-5 · doi:10.1002/(sici)1522-712x(1995)1:4<198::aid-igs2>3.0.co;2-5
- 10.1002/(SICI)1522-2594(200004)43:4<583::AID-MRM13>3.0.CO;2-B · doi:10.1002/(sici)1522-2594(200004)43:4<583::aid-mrm13>3.0.co;2-b
- Press W H, 1992
- Sibson R, 1978, J. R. Statist. Soc., 40, 234
- 10.1002/(SICI)1522-2586(199910)10:4<582::AID-JMRI12>3.0.CO;2-X · doi:10.1002/(sici)1522-2586(199910)10:4<582::aid-jmri12>3.0.co;2-x
- 10.1016/S1361-8415(96)80004-1 · doi:10.1016/s1361-8415(96)80004-1
Cited by
Items 801–900 of 1,032
A new similarity measure for intensity-based image registration
Shirpour, M., Aghajani, K., & Manzuri-Shalmani, M. (2014) · International Conference on Computer and Knowledge Engineering · doi:10.1109/iccke.2014.6993361 · Cited by 5
Manifold learning based registration algorithms applied to multimodal images
Azampour, M. F., Ghaffari, A., Hamidinekoo, A., & Fatemizadeh, E. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6943769 · Cited by 5
Features of metamict zircons based on their micrographs and the data of electron microprobe analysis
Votyakov, S., Zamyatin, D. A., Shchapova, Y., Porotnikov, A., & Krasnobaev, A. (2014) · Doklady earth sciences · doi:10.1134/s1028334x14070277 · Cited by 5
Jang, J., Kim, H. W., & Kim, Y. S. (2014) · MITAT. Minimally invasive therapy & allied technologies · doi:10.3109/13645706.2014.925929 · Cited by 5
Comparison of distance measures for manifold learning: Application to Alzheimer’s brain scans
the, A. D. N. I., & Park, H. (2012) · Journal of the Korean Physical Society · doi:10.3938/jkps.61.1148 · Cited by 5
Evaluation of Medical Image Registration by Using 3D SIFT and Phase-Only Correlation
Li, Z.-S., Kurihara, T., Matsuzaki, K., & Irie, T. (2012) · Abdominal Imaging · doi:10.1007/978-3-642-33612-6_27 · Cited by 5
Strickland, C. G., Aguiar, D. E., Nauman, E., & Talavage, T. (2011) · Journal of digital imaging · doi:10.1007/s10278-010-9336-z · Cited by 5
Automated least-squares calibration of the coregistration parameters for a micro PET-CT system
Feng, B., Yan, S., Chen, M., Austin, D. W., Deng, J., & Mintzer, R. (2010) · IEEE Nuclear Science Symposuim & Medical Imaging Conference · doi:10.1109/nssmic.2010.5874251 · Cited by 5
“This way we investigated how the number of measurements (or number of point-sources) affects the co-registration accuracy [8].”
BackgroundMethodSertel, O., Dogdas, B., Chiu, C.-S., & Gürcan, M. (2010) · IEEE International Symposium on Biomedical Imaging · doi:10.1109/isbi.2010.5490266 · Cited by 5
Comparison of Optimisation Algorithms for Deformable Template Matching
Zografos, V. (2009) · International Symposium on Visual Computing · doi:10.1007/978-3-642-10520-3_105 · Cited by 5
Synetic superimposition of dental 3D data: application in twin studies.
Smith, R. N., Townsend, G., Chen, K., & Brook, A. (2009) · Frontiers of oral biology · doi:10.1159/000242407 · Cited by 5
Nonextensive Entropic Image Registration
Mohamed, W., & Hamza, A. B. (2009) · International Conference on Image Analysis and Recognition · doi:10.1007/978-3-642-02611-9_12 · Cited by 5
A method for registration and model-based segmentation of Doppler ultrasound images
Kalinić, H., Lončarić, S., Čikeš, M., Miličić, D., Cikes, I., Sutherland, G., & Bijnens, B. (2009) · Medical Imaging · doi:10.1117/12.811331 · Cited by 5
MR image postprocessing for multiple sclerosis research.
Horsfield, M. (2008) · Neuroimaging clinics of North America · doi:10.1016/j.nic.2008.06.006 · Cited by 5
A New Method for Medical Image Registration Based on Wavelet Multi-scale Transform
Xie, J., Chen, Z.-H., & Xu, G. (2008) · 2008 ISECS International Colloquium on Computing, Communication, Control, and Management · doi:10.1109/cccm.2008.176 · Cited by 5
“Moreover, in feature-based registration, the set of identified points is sparse compared to the original image content, which makes for relatively fast optimization procedures [1, 2, 3].”
BackgroundRole of optical techniques in combined use of selected methods of medical imaging
Cysewska-Sobusiak, A., Wiczyński, G., Krawiecki, Z., & Sowier, A. (2008) · doi:10.2478/s11772-008-0010-7 · Cited by 5
A method for reducing of computational time on image registration employing wavelet transformation
Yamamura, Y., Kim, H., Tan, J., Ishikawa, S., & Yamamoto, A. (2007) · International Conference on Control, Automation and Systems · doi:10.1109/iccas.2007.4406535 · Cited by 5
Quantification of Growth and Motion Using Non-rigid Registration
Rueckert, D., Chandrashekara, R., Aljabar, P., Bhatia, K. K., Boardman, J. P., Srinivasan, L., Rutherford, M., Dyet, L. E., Edwards, A. D., Hajnal, J. V., et al. (2006) · Lecture notes in computer science · doi:10.1007/11889762_5 · Cited by 2
“Comprehensive reviews of image registration techniques can be found in [26, 21, 47].”
BackgroundFlexible Template and Model Matching Using Intensity
Buxton, B. F., & Zografos, V. (2005) · International Conference on Digital Image Computing: Techniques and Applications (DICTA) · doi:10.1109/dicta.2005.38 · Cited by 6
Optimization methods for registration of multimodal images of retina
Kubečka, L., Skokan, M., & Jan, J. (2003) · Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439) · doi:10.1109/iembs.2003.1279818 · Cited by 5
A Protocol for Optimization-Independent Similarity Measure Evaluation
Škerl, D., Likar, B., Bernard, R., & Pernuš, F. (2003) · Lecture notes in computer science · doi:10.1007/978-3-540-39701-4_35 · Cited by 5
Statistical Deformation Model: Theory and Methods
Zhuang, X., & Hu, Y. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-810493-4.00003-1 · Cited by 8
Marengo, E., & Robotti, E. (2016) · Methods in Molecular Biology · doi:10.1007/978-1-4939-3255-9 · Cited by 5
“Methods for power analysis are also available for multivariate statistics [37].”
BackgroundMethodBakker, C., de Leeuw, H., van de Maat, G. H., van Gorp, J. V., Bouwman, J., & Seevinck, P. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.023 · Cited by 5
“, breast biopsy and stereotactic surgery, and for procedures in which MRI data are to be matched with data from other modalities, as in radiotherapy treatment planning [8].”
Background3D curve constrained deformable registration using a neuro-fuzzy transformation model
Huang, X., Bari, A., Zaheer, S., Looi, T., Ren, J., & Drake, J. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6347189 · Cited by 5
“There are similar challenges for other abdominal organs [1,2,3].”
BackgroundMedical Image Registration Based on Improved PSO Algorithm
Zheng, L., Qian, G., & Lin, L. (2011) · Lecture notes in electrical engineering · doi:10.1007/978-3-642-19712-3_62 · Cited by 7
Image Registration Techniques in Nuclear Medicine Imaging
Hutton, B. F., Braun, M., & Slomka, P. J. (2006) · Kluwer Academic Publishers eBooks · doi:10.1007/0-387-25444-7_9 · Cited by 4
Registration of Vibro-acoustography Images and X-ray Mammography
Hosseini, H. G., Fatemi, M., & Alizad, A. (2005) · 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference · doi:10.1109/iembs.2005.1616809 · Cited by 5
Ultra-fast image registration embedded in intraoperative MR imaging
Tokuda, J., Morikawa, S., Dohi, T., & Hata, N. (2002) · doi:10.1007/978-3-642-56168-9_12 · Cited by 5
Scarpolini, M., Piumini, G., Gasparotti, E., Maffei, E., Cademartiri, F., Celi, S., & Viola, F. (2025) · Comput. Biol. Medicine · doi:10.1016/j.compbiomed.2025.109876 · Cited by 4
Huang, T.-M., Qi, X.-Y., Cao, L., Yang, M., Luo, H., Li, Q., Qian, P.-D., Lu, J., Lei, Z.-Q., Luo, Y.-M., et al. (2024) · Advancement of science · doi:10.1002/advs.202400653 · Cited by 4
Mang, A., He, J.-W., & Azencott, R. (2023) · Journal of Computational Physics · doi:10.48550/arxiv.2307.10114 · Cited by 4
“In (bio)medical imaging applications, the automatic matching of k-dimensional deformable shapes across subjects or multi-temporal data of individual patients is a critical step to aid clinical diagnosis [56, 78, 87, 126, 128, 148, 155, 168].”
BackgroundSi, T. (2023) · Pattern Analysis and Applications · doi:10.1007/s10044-023-01153-z · Cited by 6
“Registration is also effectively used in treatment planning [5, 6], in functional brain imaging (fMRI) [5, 7, 8], and in brain atlases and mapping [5].”
MethodThe Optimization of Multimode Fiber Speckle Sensor for Microvibration
Song, H., Sun, F.-Y., Sun, Y., & Liu, W. (2023) · International Journal of Optics · doi:10.1155/2023/3356849 · Cited by 4
“…methods calculate the correlations of specklegrams with outside disturbance, which include normalized inner-product [4], gray-levelco-occurrence matrix [7], frst moment and second moment [9], the sum of squared diferences [8], ratio image uniformity [10], mutual information [11], and so on.”
MethodDufresne, E., Fortun, D., Kremer, S., & Noblet, V. (2022) · Frontiers in Neuroimaging · doi:10.3389/fnimg.2022.1008128 · Cited by 5
“Since the Taylor expansion is valid only for small deformations, we embed the estimation in a coarse-to-fine scheme, which is a common practice in registration and motion estimation (Hill et al., 2001).”
MethodFully Automatic Registration Methods for Chest X-Ray Images
Lee, Y., Khalil, M.-A., Lee, J.-H., Syakura, A., Ding, Y.-F., & Wang, C. (2021) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-021-00666-4 · Cited by 5
Direct 3D ultrasound fusion for transesophageal echocardiography
Mao, Z., Zhao, L., Huang, S., Fan, Y., & Lee, A. P. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104502 · Cited by 8
miRID: Multi-Modal Image Registration Using Modality-Independent and Rotation-Invariant Descriptor
Borvornvitchotikarn, T., & Kurutach, W. (2020) · Symmetry · doi:10.3390/sym12122078 · Cited by 4
“For example, X-ray, ultrasound, computer tomography (CT) and magnetic resonance (MR) provide anatomical structure information, but positron emission tomography (PET) and single-photon emission computed tomography (SPECT) give the metabolism and physiological information [2].”
BackgroundTian, J., Qian, B., Zhang, S., Guo, R., Zhang, H., Jeannon, J., Jin, R., Feng, X., Zhan, Y., Liu, J., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-76081-7 · Cited by 6
Integrating image fusion with nanoparticle contrast agents for diagnosis: a review
Manson, E. N., Hasford, F., Inkoom, S., & Gedel, A. (2020) · The Egyptian Journal of Radiology and Nuclear Medicine · doi:10.1186/s43055-020-00315-x · Cited by 4
Introduction to Medical Image Registration with DeepReg, Between Old and NewPreprint
Montaña-Brown, N., Fu, Y., Saeed, S. U., Casamitjana, A., Baum, Z. M. C., Delaunay, R., Yang, Q., Grimwood, A., Min, Z., Bonmati, E., et al. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2009.01924 · Cited by 4
“rmation. Data may be aligned in many ways - spatially or temporally being two key ones. Image registration is an essential process in many clinical applications and computer-assisted interventions [1][11]. Applications of medical image registration include - but are not limited to: { Multi-modal registration for image…”
BackgroundComparison of intraoperative CT with postoperative MRI for determining DBS electrode coordinates.
Girgis, F., Zarabi, H., Said, M., Zhang, L., Shahlaie, K., & Saez, I. (2020) · World Neurosurgery · doi:10.1016/j.wneu.2020.02.108 · Cited by 4
SCreg: a registration-based platform to compare unicondylar knee arthroplasty SPECT/CT scans
Dandois, F., Buck, S. D., Beckers, L., Shah, D., Slane, L., Vandenneucker, H., & Scheys, L. (2019) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-020-3185-9 · Cited by 4
“By consequence, an image registration problem (23-25) must be solved in order to spatially align SPECT/CT scans and enable full resolution comparisons.”
BackgroundCorrelation Property of Multipartite Quantum Image
Sanchez, M. A. M., Sun, G.-H., & Dong, S.-H. (2019) · International Journal of Theoretical Physics · doi:10.1007/s10773-019-04247-9 · Cited by 4
Automatic Detection of Cervical Spine Ligaments Origin and Insertion Points
Al-Dhamari, I., Bauer, S., Keller, E., & Paulus, D. (2019) · IEEE International Symposium on Biomedical Imaging · doi:10.1109/isbi.2019.8759223 · Cited by 4
“In this paper, we present a fast method to detect all these points automatically using the medical image registration technique[3, 4].”
MethodZamyatin, D. A., Votyakov, S., & Shchapova, Y. (2019) · Doklady earth sciences · doi:10.1134/s1028334x19040111 · Cited by 4
Entropic Graphs for Registration
Neemuchwala, H., & Hero, A. O. (2005) · Signal processing and communications · doi:10.1201/9781420026986.ch6 · Cited by 23
“Several other matching functions have been suggested in the literature [37], [42], [66].”
BackgroundEvolutionary Algorithms for Query Op-timization in Distributed Database Sys-tems: A review
Ali, Z., Kiran, H. M., & Shahzad, W. (2018) · ADCAIJ ADVANCES IN DISTRIBUTED COMPUTING AND ARTIFICIAL INTELLIGENCE JOURNAL · doi:10.14201/adcaij201873115128 · Cited by 5
A stabilized multigrid solver for hyperelastic image registration
Ruthotto, L., Greif, C., & Modersitzki, J. (2017) · Numerical Linear Algebra with Applications · doi:10.1002/nla.2095 · Cited by 5
The implementation of Keren imagie registration system on Raspberry Pi platform
Feng, Z., Guo, Y.-N., Xing, J., & Huo, X. (2017) · Cybersecurity and Cyberforensics Conference · doi:10.23919/chicc.2017.8029144 · Cited by 4
A human visual based binarization technique for histological images
M., S., Rajendran, R., Panetta, K., & Agaian, S. (2017) · Commercial + Scientific Sensing and Imaging · doi:10.1117/12.2262815 · Cited by 4
“Medical image segmentation finds its significance in anatomical research on regular body structure, quantification of tissues into metrics like surface area and volume, localization of abnormalities, prognosis and treatment planning, 2D and 3D registration of imaging data, and computer-aided surgery [11-14].”
BackgroundMultimodal Imaging and Image Fusion
Wehrl, H., Amend, M., & Thielcke, A. (2017) · doi:10.1007/978-3-319-42202-2_17 · Cited by 4
A new optical flow model for motor unit conduction velocity estimation in multichannel surface EMG
Potočnik, B., & Holobar, A. (2017) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.02.006 · Cited by 4
CT thermometry for cone-beam CT guided ablation
Destefano, Z., Abi-Jaoudeh, N., Li, M., Wood, B., Summers, R., & Yao, J.-H. (2016) · SPIE Medical Imaging · doi:10.1117/12.2216302 · Cited by 4
Non‐rigid alignment in electron tomography in materials science
Printemps, T., Bernier, N., Bleuet, P., Mula, G., & Hervé, L. (2016) · Journal of Microscopy · doi:10.1111/jmi.12400 · Cited by 5
“Yet, nonrigid registration has been widely used for medical applications (Hill et al., 2001; Chui & Rangarajan, 2003; Derksen et al., 2015).”
MethodA Literature Survey of Ultrasound and Computed Tomography-Based Cardiac Image Registration
Ming, C. T., Omar, Z., Mahmood, N. H., & Kadiman, S. (2015) · Jurnal Teknologi · doi:10.11113/jt.v74.4672 · Cited by 4
“The cardiac position tends to change with each movement involving body position, respiration and cardiac contraction [14, 46].”
BackgroundAssessment of fiducial markers to enable the co-registration of photographs and MRI data.
Webb, B., Petrovic, A., Urschler, M., & Scheurer, E. (2015) · Forensic Science International · doi:10.1016/j.forsciint.2014.12.027 · Cited by 4
Lee, M.-W., Lin, W.-T., & Chen, Y.-C. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/2/473 · Cited by 4
Image registration guided, sparsity constrained reconstructions for dynamic MRI
Jin, J., Liu, F., & Crozier, . (2014) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.08.006 · Cited by 4
“Registration has been comprehensively reviewed by many authors [38,39].”
Background3D non-rigid surface-based MR-TRUS registration for image-guided prostate biopsy
Sun, Y., Wu, Q., Romagnoli, C., & Fenster, A. (2014) · Medical Imaging · doi:10.1117/12.2043662 · Cited by 4
Rigid point registration circuits
Fitzpatrick, J. (2014) · Medical Imaging · doi:10.1117/12.2043951 · Cited by 4
Coordinate transformation after stereotactic frame reapplication in Gamma Knife radiosurgery.
Park, J., Chung, H.-T., Kim, D. G., Kim, Y.-H., Han, J.-H., Kim, C.-Y., Oh, C., & Suh, T. (2014) · Physica medica (Testo stampato) · doi:10.1016/j.ejmp.2013.05.002 · Cited by 4
“For more reliable results, volumetric image registration techniques based on mutual information should be used [18].”
BackgroundTokunaga, C., Arimura, H., Yoshiura, T., Ohara, T., Yamashita, Y., Kobayashi, K., Magome, T., Nakamura, Y., Honda, H., Hirata, H., et al. (2013) · doi:10.4236/jbise.2013.63a042 · Cited by 4
“The brain parenchymal region was segmented by registering and masking of the brain model image to each head region, in which the BG and CSF regions were removed, based on a global linear registration of an affine transformation [18,19] and a local non-linear registration of the free-form deformation (FFD) [20-23].”
MethodVehicle detection using multimodal imaging sensors from a moving platform
Dickson, C. N., Wallace, A., Kitchin, M., & Connor, B. (2012) · Other Conferences · doi:10.1117/12.971464 · Cited by 4
“This is achieved using the relatively simple voting method where detection maps are combined additively and a threshold is then applied which allows the user to select how many HGs must agree: g (y′ (x)) = { 1 ∑n i αiy ′ i (x) ≥ t 0 otherwise (13)”
MethodCo-registration of MR-mammography and X-ray mammography.
Dietzel, M., Baltzer, P., Hopp, T., Ruiter, N., & Kaiser, W. (2012) · European Journal of Radiology · doi:10.1016/s0720-048x(12)70011-6 · Cited by 4
“This approach allows condensing radiological information provided by various diagnostic exams into one single clinical dataset [2].”
BackgroundMethodSimilarity in Mammography CAD Using CBIR Approach: A Validation Study
Lan, Y., Ren, H.-Z., Zhang, Y., & Yu, H.-B. (2012) · International Conference on Intelligent Human-Machine Systems and Cybernetics · doi:10.1109/ihmsc.2012.185 · Cited by 4
“At last, the DI can be calculated according to the equation 1.”
MethodNon-rigid registration of multiphoton microscopy images using B-splines
Lorenz, K. S., Salama, P., Dunn, K., & Delp, E. (2011) · Medical Imaging · doi:10.1117/12.878304 · Cited by 4
“It is often desirable to transform information obtained from multiple images into a single common coordinate system encompassing the knowledge available from all the various source images.(3) There exists much controversy over approaches to image registration with confocal and multiphoton microscopy.”
BackgroundMedical image registration using TSallis Entropy in Statistical Parametric Mapping (SPM)
Amaral-Silva, H. T., Murta, L., Wichert-Ana, L., Sakamoto, A. C., & Azevedo-Marques, P. (2010) · 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology · doi:10.1109/iembs.2010.5628080 · Cited by 4
Multimodality Image Alignment Using Information-Theoretic Approach
Khader, M., Hamza, A. B., & Bhattacharya, P. (2010) · Lecture notes in computer science · doi:10.1007/978-3-642-13775-4_4 · Cited by 6
A statistical similarity measure for non-rigid multi-modal image registration
Shi, J.-L., Chen, Y., Rao, M., & Lee, J. (2010) · Medical Imaging · doi:10.1117/12.844553 · Cited by 4
Attribute vector guided groupwise registration
Wang, Q., Wu, G., Yap, P., & Shen, D. G. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.01.040 · Cited by 37
Intelligent automated brain image segmentation
Seixas, F. L., Conci, A., Muchaluat-Saade, D. C., & de Souza, A. S. (2009) · International Journal of Innovative Computing and Applications · doi:10.1504/ijica.2009.027994 · Cited by 5
Wu, T.-H., Liang, C.-H., Wu, J., Lien, C.-Y., Yang, B.-H., Huang, Y.-H., & Lee, J. S. (2009) · doi:10.1088/1748-0221/4/07/p07006 · Cited by 4
“To study an image positioning error between center of the CBCT, corresponding to the XVI isocenter Pisoand reference isocenter Oisofrom CT, we took advantage of the build-in XVI software using cross correction algorithm [4] for co-registration.”
Zielińska-Dąbrowska, S., Kukołowicz, P., & Czebek-Szebek, P. (2009) · doi:10.1016/s1507-1367(10)60027-2 · Cited by 4
“125 REP PRACT ONCOL RADIOTHER • 2009 • 14/4/: 122–132 method, the images were registered using a maximization of mutual information algorithm (MMI algorithm) [19, 20].”
BackgroundMethodReconfigurable acceleration of 3D image registration
Tsoi, K.-H., Rueckert, D., Ho, C., & Luk, W. (2009) · Southern Conference Programmable Logic · doi:10.1109/spl.2009.4914908 · Cited by 4
Ultra-low Dose Lung CT Perfusion Regularized by a Previous Scan
Yu, H., Zhao, S., Hoffman, E. A., & Wang, G. (2009) · Academic Radiology · doi:10.1016/j.acra.2008.09.003 · Cited by 65
A Fast and Automatic Method for 3D Rigid Registration of MR Images of the Human Brain
Favretto, F. O., Bergo, F., & Falcão, A. (2008) · 2008 XXI Brazilian Symposium on Computer Graphics and Image Processing · doi:10.1109/sibgrapi.2008.33 · Cited by 4
“Image registration is the process that aligns two or more images in a common reference system of spacial coordinates [12].”
BackgroundPET/CT alignment for small animal scanners based on capillary detection
Rodriguez-Ruano, A., Pascau, J., Chamorro, J., Sisniega, A., García-Vázquez, V., Udias, A., Vaquero, J., & Desco, M. (2008) · IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2008.4774117 · Cited by 4
Continuous Sampling in Mutual-Information Registration
Seppä, M. (2008) · IEEE Transactions on Image Processing · doi:10.1109/tip.2008.920738 · Cited by 14
Grades computacionais na recuperação de imagens médicas baseada em conteúdo
Oliveira, M. C., de Azevedo‐Marques, P. M., & Cirne, W. (2007) · Radiologia Brasileira · doi:10.1590/s0100-39842007000400011 · Cited by 6
A Three-Dimensional Registration Method for MicroUS/MicroPET Multimodality Small-Animal Imaging
Liao, A.-H., Chen, L.-Y., Cheng, W.-F., & Li, P.-C. (2007) · Ultrasonic imaging (Print) · doi:10.1177/016173460702900302 · Cited by 4
Toward Unsupervised Segmentation of Semi-Rigid Low-Resolution Molecular Surfaces
Guibas, L., & Wang, Y.-S. (2006) · Algorithmica · doi:10.1007/s00453-007-0151-y · Cited by 4
Estimating the Pose of a 3D Sensor in a Non-rigid Environment
Bartoli, A. (2006) · WDV · doi:10.1007/978-3-540-70932-9_19 · Cited by 4
“A large body of work has been done in the medical imaging community, see [7] for a review, but with the aim of estimating dense deformation fields from dense, often voxelbased, reconstructions.”
BackgroundReal-time registration by tracking for MR-guided cardiac interventions
Chung, D., Satkunasingham, J., Wright, G., & Radau, P. (2006) · SPIE Medical Imaging · doi:10.1117/12.655601 · Cited by 4
Automated feature-based alignment for 3D volume reconstruction of CLSM imagery
Lee, S.-C., & Bajcsy, P. (2006) · SPIE Medical Imaging · doi:10.1117/12.653881 · Cited by 4
Displacement Correction Scheme for MR-Guided Interstitial Laser Therapy
Suprijanto, S., Vogel, M., Vos, F., Vrooman, H., & Vossepoel, A. (2003) · International Conference on Medical Image Computing and Computer-Assisted Intervention · doi:10.1007/978-3-540-39903-2_49 · Cited by 4
“In this work, the Entropy Correlation Coefficient (ECC)[8], in formula ECC(ST , Sbl) = 2I(ST , Sbl) H(ST ) + H(Sbl) (4) was used, where ST and Sbl represent the intensities of the thermal and the baseline images, I(ST , Sbl) and H(.) represent the mutual information of both images and the entropy of the image, respect…”
MethodInfluentialMedical imaging at Guy's Hospital, King's College London
Hawkes, D. J., & Hill, D. L. G. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815866 · Cited by 260
Self-citationPetrie, I. A., Flynn, A., Pedley, R., Green, A., El-Emir, E., Dearling, J., Boxer, G., Boden, R., & Begent, R. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/20/307 · Cited by 4
Barboriak, D., & Provenzale, J. (2002) · AJR. American journal of roentgenology · doi:10.2214/ajr.179.1.1790245 · Cited by 4
Landman, B. A., Lyu, I., Huo, Y., & Asman, A. J. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816176-0.00011-9 · Cited by 8
Speight, R. (2019) · MRI for Radiotherapy · doi:10.1007/978-3-030-14442-5_2 · Cited by 4
Algorithms for Warping of 2-D PAGE Maps
Manfredi, M., Robotti, E., & Marengo, E. (2015) · Methods in molecular biology · doi:10.1007/978-1-4939-3255-9_8 · Cited by 3
Nonlinear Registration Via Displacement Fields
Modersitzki, J., Heldmann, S., & Papenberg, N. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-397025-1.00300-6 · Cited by 5
Whole-Body Image Registration Using Patient-Specific Nonlinear Finite Element Model
Li, M., Wittek, A., Joldes, G., Zhang, G.-Y., Dong, F., Kikinis, R., & Miller, K. (2014) · doi:10.1007/978-1-4939-0745-8_9 · Cited by 4
“However, before such comparison can be done, the images need to be aligned in a process known as image registration [2].”
BackgroundMagome, T., Arimura, H., Kakeda, S., Yamamoto, D., Kawata, Y., Yamashita, Y., Higashida, Y., Toyofuku, F., Ohki, M., & Korogi, Y. (2010) · Radiological Physics and Technology · doi:10.1007/s12194-010-0106-x · Cited by 4
“The slices including the basal ganglia and thalamus were selected manually, and then the basal ganglia and thalamus template was adjusted to each brain parenchyma using a 2D affine transformation [34].”
MethodEx Vivo and In Vitro Cross Calibration Methods
Dubois, A., Dauguet, J., & Delzescaux, T. (2011) · doi:10.1007/978-3-642-12945-2_23 · Cited by 4
Automated geometric features evaluation method for normal foot skeleton model
Borucki, B., Nowinski, K., Chlebiej, M., Rutkowski, A., Adamczyk, P., & Laskowski, J. (2011) · Ann. UMCS Informatica · doi:10.2478/v10065-011-0034-3 · Cited by 4
Taira, R. K., Iglesias, J. E., & Jahanshad, N. (2009) · Springer eBooks · doi:10.1007/978-1-4419-0385-3_5 · Cited by 5
Registration of 3D ultrasound to computed tomography images of the kidney
Xiang, J. (2010) · doi:10.14288/1.0071184 · Cited by 4
Remeijer, P., & van Herk, M. V. (2006) · doi:10.1007/3-540-30356-1_3 · Cited by 4
Metadata
- Authors
- Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J.
- Affiliations
- Guy's Hospital (GB)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2001-02-15
- Volume
- 46
- Issue
- 3
- Pages
- R1-R45
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2140139548
- Cited by
- 2,093
- References
- 127
- Citations by year
- 2026: 19 · 2025: 21 · 2024: 40 · 2023: 47 · 2022: 45 · 2021: 44 · 2020: 53 · 2019: 57 · 2018: 66 · 2017: 89 · 2016: 69 · 2015: 100 · 2014: 104 · 2013: 124 · 2012: 105
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Research Portal (King's College London) (submittedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Keywords
- medical image registration, multimodal image fusion, motion compensation, image-guided interventions, rigid transformation, non-rigid registration, tissue deformation, temporal image sequences
- MeSH terms
- Algorithms, Diagnostic Imaging, Humans, Image Processing, Computer-Assisted, Registries, Research
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.