Sparse-view x-ray CT reconstruction via total generalized variation regularization
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Sparse-view CT reconstruction algorithms via total variation (TV) optimize the data iteratively on the basis of a noise- and artifact-reducing model, resulting in significant radiation dose reduction while maintaining image quality. However, the piecewise constant assumption of TV minimization often leads to the appearance of noticeable patchy artifacts in reconstructed images. To obviate this drawback, we present a penalized weighted least-squares (PWLS) scheme to retain the image quality by incorporating the new concept of total generalized variation (TGV) regularization. We refer to the proposed scheme as 'PWLS-TGV' for simplicity. Specifically, TGV regularization utilizes higher order derivatives of the objective image, and the weighted least-squares term considers data-dependent variance estimation, which fully contribute to improving the image quality with sparse-view projection measurement. Subsequently, an alternating optimization algorithm was adopted to minimize the associative objective function. To evaluate the PWLS-TGV method, both qualitative and quantitative studies were conducted by using digital and physical phantoms. Experimental results show that the present PWLS-TGV method can achieve images with several noticeable gains over the original TV-based method in terms of accuracy and resolution properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonlinear total variation based noise removal algorithms
Rudin, L. I., Osher, S., & Fatemi, E. (1992) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(92)90242-f · Cited by 15,704
A universal image quality index
Wang, Z., & Bovik, A. C. (2002) · IEEE Signal Processing Letters · doi:10.1109/97.995823 · Cited by 5,757
A First-Order Primal-Dual Algorithm for Convex Problems with Applications to Imaging
Chambolle, A., & Pock, T. (2011) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-010-0251-1 · Cited by 4,336
Sidky, E. Y., & Pan, X. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/021 · Cited by 1,995
Bredies, K., Kunisch, K., & Pock, T. (2010) · SIAM Journal on Imaging Sciences · doi:10.1137/090769521 · Cited by 1,535
Einstein, A. J., Henzlova, M. J., & Rajagopalan, S. (2007) · JAMA · doi:10.1001/jama.298.3.317 · Cited by 1,410
4D XCAT phantom for multimodality imaging research
Segars, W. P., Sturgeon, G., Mendonca, S., Grimes, J., & Tsui, B. M. W. (2010) · Medical Physics · doi:10.1118/1.3480985 · Cited by 1,287
Chen, G.-H., Tang, J., & Leng, S. (2008) · Medical Physics · doi:10.1118/1.2836423 · Cited by 1,141
Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT
Sidky, E. Y., Kao, C.-M., & Pan, X. (2006) · Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · doi:10.3233/xst-2006-00155 · Cited by 1,091
CT Dose Reduction and Dose Management Tools: Overview of Available Options
McCollough, C. H., Bruesewitz, M. R., & Kofler, J. M. (2006) · RadioGraphics · doi:10.1148/rg.262055138 · Cited by 768
Techniques and Applications of Automatic Tube Current Modulation for CT
Kalra, M. K., Maher, M. M., Toth, T. L., Schmidt, B., Westerman, B. L., Morgan, H. T., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2333031150 · Cited by 725
Statistical image reconstruction for polyenergetic X-ray computed tomography
Elbakri, I. A., & Fessler, J. A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993128 · Cited by 691
Low-Dose X-ray CT Reconstruction via Dictionary Learning
Xu, Q., Yu, H., Mou, X., Zhang, L., Hsieh, J., & Wang, G. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2195669 · Cited by 690
Second order total generalized variation (TGV) for MRI
Knoll, F., Bredies, K., Pock, T., & Stollberger, R. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22595 · Cited by 634
Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography
Sukovic, P., & Clinthorne, N. H. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.896783 · Cited by 552
Wang, J., Li, T., Lu, H., & Liang, Z. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.882141 · Cited by 533
Self-citationCompressed sensing based interior tomography
Yu, H., & Wang, G. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/9/014 · Cited by 519
Low-dose CT reconstruction via edge-preserving total variation regularization
Tian, Z., Jia, X., Yuan, K., Pan, T., & Jiang, S. B. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/18/011 · Cited by 396
Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT
Bian, J., Siewerdsen, J. H., Han, X., Sidky, E. Y., Prince, J. L., Pelizzari, C. A., & Pan, X. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/22/001 · Cited by 373
Liu, Y., Ma, J., Fan, Y., & Liang, Z. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/23/7923 · Cited by 335
Self-citationNonlinear sinogram smoothing for low-dose X-ray CT
Li, T., Li, X., Wang, J., Wen, J., Lu, H., Hsieh, J., & Liang, Z. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2004.834824 · Cited by 309
Self-citationTang, J., Nett, B. E., & Chen, G.-H. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/19/008 · Cited by 282
Accelerating popular tomographic reconstruction algorithms on commodity PC graphics hardware
Xu, F., & Mueller, K. (2005) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2005.851398 · Cited by 252
Ma, J., Huang, J., Feng, Q., Zhang, H., Lu, H., Liang, Z., & Chen, W. (2011) · Medical Physics · doi:10.1118/1.3638125 · Cited by 249
Self-citationYu, L., Bruesewitz, M. R., Thomas, K. B., Fletcher, J. G., Kofler, J. M., & McCollough, C. H. (2011) · RadioGraphics · doi:10.1148/rg.313105079 · Cited by 217
Iterative image reconstruction for CBCT using edge‐preserving prior
Wang, J., Li, T., & Xing, L. (2009) · Medical Physics · doi:10.1118/1.3036112 · Cited by 188
Total variation regulated EM algorithm [SPECT reconstruction]
Panin, V. Y., Zeng, G. L., & Gullberg, G. T. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.819305 · Cited by 183
Variance analysis of x-ray CT sinograms in the presence of electronic noise background
Ma, J., Liang, Z., Fan, Y., Liu, Y., Huang, J., Chen, W., & Lu, H. (2012) · Medical Physics · doi:10.1118/1.4722751 · Cited by 177
Self-citationAn experimental study on the noise properties of x-ray CT sinogram data in Radon space
Wang, J., Lu, H., Liang, Z., Eremina, D., Zhang, G., Wang, S., Chen, J., & Manzione, J. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/12/018 · Cited by 165
Self-citationMa, J., Zhang, H., Gao, Y., Huang, J., Liang, Z., Feng, Q., & Chen, W. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/22/7519 · Cited by 163
Self-citationTotal variation norm for three-dimensional iterative reconstruction in limited view angle tomography
Persson, M., Bone, D., & Elmqvist, H. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/318 · Cited by 161
Jørgensen, J. S., Sidky, E. Y., & Pan, X. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2230185 · Cited by 151
Park, J. C., Song, B., Kim, J. S., Park, S. H., Kim, H. K., Liu, Z., Suh, T. S., & Song, W. Y. (2012) · Medical Physics · doi:10.1118/1.3679865 · Cited by 149
Total Variation-Stokes Strategy for Sparse-View X-ray CT Image Reconstruction
Liu, Y., Liang, Z., Ma, J., Lu, H., Wang, K., Zhang, H., & Moore, W. H. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2295738 · Cited by 142
Self-citationPrior image constrained compressed sensing: Implementation and performance evaluation
Thériault-Lauzier, P., Tang, J., & Chen, G. (2011) · Medical Physics · doi:10.1118/1.3666946 · Cited by 120
Optimization-based reconstruction of sparse images from few-view projections
Han, X., Bian, J., Ritman, E. L., Sidky, E. Y., & Pan, X. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/16/5245 · Cited by 108
Total variation regulated EM algorithm
Panin, V., Zeng, G. L., & Gullberg, G. T. (2002) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.1998.773841 · Cited by 100
The meaning of interior tomography
Wang, G., & Yu, H. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/16/r161 · Cited by 94
Niu, T., & Zhu, L. (2012) · Medical Physics · doi:10.1118/1.4729837 · Cited by 86
Bredies, K., Dong, Y., & Hintermüller, M. (2012) · International Journal of Computer Mathematics · doi:10.1080/00207160.2012.700400 · Cited by 81
Huang, J., Zhang, Y., Ma, J., Zeng, D., Bian, Z., Niu, S., Feng, Q., Liang, Z., & Chen, W. (2013) · PLoS ONE · doi:10.1371/journal.pone.0079709 · Cited by 70
Self-citationThériault-Lauzier, P., & Chen, G. (2013) · Medical Physics · doi:10.1118/1.4773866 · Cited by 68
Bian, Z., Ma, J., Huang, J., Zhang, H., Niu, S., Feng, Q., Liang, Z., & Chen, W. (2013) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2013.05.004 · Cited by 51
Self-citationLow-dose x-ray phase-contrast and absorption CT using equally sloped tomography
Fahimian, B., Mao, Y. L., Cloetens, P., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/18/008 · Cited by 47
Wolf, P. A., Jørgensen, J. S., Schmidt, T. G., & Sidky, E. Y. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/16/5629 · Cited by 37
Cited by
A Sparse-View CT Reconstruction Method Based on Combination of DenseNet and Deconvolution
Zhang, Z., Liang, X., Dong, X., Xie, Y., & Cao, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2823338 · Cited by 447
LEARN: Learned Experts’ Assessment-Based Reconstruction Network for Sparse-Data CT
Chen, H., Zhang, Y., Chen, Y., Zhang, J., Zhang, W., Sun, H., Lv, Y., Liao, P., Zhou, J., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2805692 · Cited by 433
CNN-Based Projected Gradient Descent for Consistent CT Image Reconstruction
Gupta, H., Jin, K. H., Nguyen, H. Q., McCann, M. T., & Unser, M. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2832656 · Cited by 380
Optimizing a Parameterized Plug-and-Play ADMM for Iterative Low-Dose CT Reconstruction
He, J., Yang, Y., Wang, Y., Zeng, D., Bian, Z., Zhang, H., Sun, J., Xu, Z., & Ma, J. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2865202 · Cited by 178
“With slight revisions, the proposed 3pADMM could also be applied in other CT applications, such as sparse-view CT reconstruction [44], spectral CT reconstruction [45], and perfusion CT deconvolution [46].”
MethodSelf-citationWavelet-Improved Score-Based Generative Model for Medical Imaging
Wu, W., Wang, Y., Liu, Q., Wang, G., & Zhang, J. (2024) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2023.3325824 · Cited by 105
“(15), we employ the separable quadratic surrogates (SQS) [43], [44] algorithm.”
BackgroundMethod
Metadata
- Authors
- Niu, S., Gao, Y., Bian, Z., Huang, J., Chen, W., Yu, G., Liang, Z., & Ma, J.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2014-05-19
- Volume
- 59
- Issue
- 12
- Pages
- 2997-3017
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2054393756
- Cited by
- 291
- References
- 45
- FWCI
- 12.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.