Diffuse optics for tissue monitoring and tomography
Open accessThe DOI matches its Crossref record; 311 of the 311 references it cites were found in a registry or an index.
Abstract
This review describes the diffusion model for light transport in tissues and the medical applications of diffuse light. Diffuse optics is particularly useful for measurement of tissue hemodynamics, wherein quantitative assessment of oxy- and deoxy-hemoglobin concentrations and blood flow are desired. The theoretical basis for near-infrared or diffuse optical spectroscopy (NIRS or DOS, respectively) is developed, and the basic elements of diffuse optical tomography (DOT) are outlined. We also discuss diffuse correlation spectroscopy (DCS), a technique whereby temporal correlation functions of diffusing light are transported through tissue and are used to measure blood flow. Essential instrumentation is described, and representative brain and breast functional imaging and monitoring results illustrate the workings of these new tissue diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hanahan, D., & Weinberg, R. A. (2000) · Cell · doi:10.1016/s0092-8674(00)81683-9 · Cited by 29,219
Carslaw, H. S., & Jaeger, J. C. (1947) · International Linear Collider · Cited by 21,232
Chandrasekhar, S. (1950) · CERN Document Server (European Organization for Nuclear Research) · Cited by 8,702
Einstein, A. (1905) · Annalen der Physik · doi:10.1002/andp.19053220806 · Cited by 8,265
Encyclopedia of Analytical Chemistry: Applications, Theory and Instrumentation
(2006) · Wiley eBooks · doi:10.1002/9780470027318 · Cited by 7,403
Statistical Methods in Cancer Research
Breslow, N. E. (1980) · Cited by 7,332
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Dougherty, T. J., Gomer, C. J., Henderson, B. W., Jori, G., Kessel, D., Korbelik, M., Moan, J., & Peng, Q. (1998) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/90.12.889 · Cited by 4,716
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-10906-3 · Cited by 4,709
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Cited by
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274
“The literature on the diffusion model of light transport in tissues has been recently reviewed (Durduran et al., 2010).”
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Vibrational spectroscopic imaging of living systems: An emerging platform for biology and medicine
Cheng, J.-X., & Xie, X. S. (2015) · Science · doi:10.1126/science.aaa8870 · Cited by 874
Hemmer, E., Benayas, A., Légaré, F., & Vetrone, F. (2016) · Nanoscale Horizons · doi:10.1039/c5nh00073d · Cited by 731
Broadband (550–1350 nm) diffuse optical characterization of thyroid chromophores
Konugolu Venkata Sekar, S., Farina, A., Dalla Mora, A., Lindner, C., Pagliazzi, M., Mora, M., Aranda, G., Dehghani, H., Durduran, T., Taroni, P., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-27684-8 · Cited by 549
Self-citationDiffuse correlation spectroscopy for non-invasive, micro-vascular cerebral blood flow measurement
Durduran, T., & Yodh, A. G. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.017 · Cited by 536
Self-citationTime domain functional NIRS imaging for human brain mapping
Torricelli, A., Contini, D., Pifferi, A., Caffini, M., Re, R., Zucchelli, L., & Spinelli, L. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.106 · Cited by 466
Modified Beer-Lambert law for blood flow
Baker, W. B., Parthasarathy, A. B., Busch, D. R., Mesquita, R. C., Greenberg, J. H., & Yodh, A. G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.004053 · Cited by 283
Self-citationEigenspectra optoacoustic tomography achieves quantitative blood oxygenation imaging deep in tissues
Tzoumas, S., Nunes, A., Olefir, I., Stangl, S., Symvoulidis, P., Glasl, S., Bayer, C., Multhoff, G., & Ntziachristos, V. (2016) · Nature Communications · doi:10.1038/ncomms12121 · Cited by 248
New frontiers in time-domain diffuse optics, a review
Pifferi, A., Contini, D., Mora, A. D., Farina, A., Spinelli, L., & Torricelli, A. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091310 · Cited by 245
“The study of photon propagation in highly scattering media (diffuse optics) is a powerful tool to noninvasively investigate biological tissues in depth.(1,2) For most biological media in the”
BackgroundCarbon Nanomaterial Fluorescent Probes and Their Biological Applications
Krasley, A. T., Li, E., Galeana, J. M., Bulumulla, C., Beyene, A. G., & Demirer, G. S. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00581 · Cited by 242
Hemmer, E., Acosta-Mora, P., Méndez-Ramos, J., & Fischer, S. (2017) · Journal of Materials Chemistry B · doi:10.1039/c7tb00403f · Cited by 231
Wang, X., Tian, F., Soni, S. S., Gonzalez-Lima, F., & Liu, H. (2016) · Scientific Reports · doi:10.1038/srep30540 · Cited by 219
“This may lead to a greater differential hemoglobin concentration in the LLLT-stimulated brain region, with a relative [HbO] increase and [Hb] decrease [24].”
Diffuse correlation spectroscopy for measurement of cerebral blood flow: future prospects
Buckley, E. M., Parthasarathy, A. B., Grant, P. E., Yodh, A. G., & Franceschini, M. A. (2014) · Neurophotonics · doi:10.1117/1.nph.1.1.011009 · Cited by 216
Self-citationSmart optical coherence tomography for ultra-deep imaging through highly scattering media
Badon, A., Li, D., Lerosey, G., Boccara, A. C., Fink, M., & Aubry, A. (2016) · Science Advances · doi:10.1126/sciadv.1600370 · Cited by 207
Cerebral Oxygen Metabolism in Neonates with Congenital Heart Disease Quantified by MRI and Optics
Jain, V., Buckley, E. M., Licht, D. J., Lynch, J. M., Schwab, P. J., Naim, M. Y., Lavin, N. A., Nicolson, S. C., Montenegro, L. M., Yodh, A. G., et al. (2014) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2013.214 · Cited by 198
Self-citationDirect measurement of tissue blood flow and metabolism with diffuse optics
Mesquita, R. C., Durduran, T., Yu, G., Buckley, E. M., Kim, M. N., Zhou, C., Choe, R., Sunar, U., & Yodh, A. G. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0232 · Cited by 195
Self-citationReview of optical breast imaging and spectroscopy
Grosenick, D., Rinneberg, H., Cubeddu, R., & Taroni, P. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091311 · Cited by 187
“Although a detailed microscopic model relating the drop in the field autocorrelation function with correlation time is missing up to now,(123) changes in this index are taken as a quantitative measure for changes in blood flow.(122) The drop in the field autocorrelation is best fitted to a Brownian motion model, rathe…”
MethodOxygen‐Sensing Methods in Biomedicine from the Macroscale to the Microscale
Roussakis, E., Li, Z., Nichols, A. J., & Evans, C. L. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201410646 · Cited by 184
Hybrid EEG-fNIRS Asynchronous Brain-Computer Interface for Multiple Motor Tasks
Buccino, A. P., Keles, H. O., & Omurtag, A. (2016) · PLOS ONE · doi:10.1371/journal.pone.0146610 · Cited by 183
“In most fNIRS studies the use of two distinct wavelengths allows the extraction of the concentration changes of oxy- and deoxyhemoglobin (HbO and HbR) in the outer layers of the cortex [13].”
BackgroundEstablishing the diffuse correlation spectroscopy signal relationship with blood flow
Boas, D. A., Sakadžic, S., Selb, J., Farzam, P., Franceschini, M. A., & Carp, S. A. (2016) · Neurophotonics · doi:10.1117/1.nph.3.3.031412 · Cited by 181
“This is justified by experimental studies in animals, which showed that cessation of blood flow results in a nearly 100-fold reduction in the observed dynamics.(4) In this paper, we will assume that RBCs are the only source of dynamic scattering events, and we will use PRBC instead of α to denote the probability of sc…”
MethodSpinelli, L., Botwicz, M., Zolek, N., Kacprzak, M., Milej, D., Sawosz, P., Liebert, A., Weigel, U., Durduran, T., Foschum, F., et al. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002037 · Cited by 173
Self-citationOptical imaging and spectroscopy for the study of the human brain: status report
Ayaz, H., Baker, W. B., Blaney, G., Boas, D. A., Bortfeld, H., Brady, K., Brake, J., Brigadoi, S., Buckley, E. M., Carp, S. A., et al. (2022) · Neurophotonics · doi:10.1117/1.nph.9.s2.s24001 · Cited by 170
“Briefly, DCS typically uses fluctuations of collected light intensity to measure motions of scatterers in the light path.(22) Measurement of these fluctuations is often derived from the temporal autocorrelation functions of the diffuse light, but”
BackgroundSelf-citationDiffuse optical characterization of collagen absorption from 500 to 1700 nm
Sekar, S. K. V., Bargigia, I., Mora, A. D., Taroni, P., Ruggeri, A., Tosi, A., Pifferi, A., & Farina, A. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.1.015006 · Cited by 168
High-density diffuse optical tomography for imaging human brain function
Wheelock, M. D., Culver, J. P., & Eggebrecht, A. T. (2019) · Review of Scientific Instruments · doi:10.1063/1.5086809 · Cited by 168
Selb, J., Boas, D. A., Chan, S.-T., Evans, K. C., Buckley, E. M., & Carp, S. A. (2014) · Neurophotonics · doi:10.1117/1.nph.1.1.015005 · Cited by 165
Lee, J. Y. K., Thawani, J. P., Pierce, J., Zeh, R., Martinez-Lage, M., Chanin, M., Venegas, O., Nims, S., Learned, K., Keating, J., et al. (2016) · Neurosurgery · doi:10.1227/neu.0000000000001450 · Cited by 160
Lynch, J. M., Buckley, E. M., Schwab, P. J., McCarthy, A. L., Winters, M. E., Busch, D. R., Xiao, R., Goff, D. A., Nicolson, S. C., Montenegro, L. M., et al. (2014) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2014.05.081 · Cited by 144
“DCS measures the temporal fluctuations of the reflected light intensity at the tissue surface, which are primarily caused by moving red blood cells.(15,26,27)”
BackgroundMethodSelf-citationFarzam, P., Starkweather, Z., & Franceschini, M. A. (2018) · Physiological Reports · doi:10.14814/phy2.13664 · Cited by 107
Pulsatile and steady-state hemodynamics of the human patella bone by diffuse optical spectroscopy
Farzam, P., Zirak, P., Binzoni, T., & Durduran, T. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/8/839 · Cited by 28
Self-citationImpact of cutaneous blood flow on NIR-DCS measures of skeletal muscle blood flow index
Bartlett, M. F., Akins, J. D., Oneglia, A. P., Brothers, R. M., Wilkes, D., & Nelson, M. D. (2021) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00337.2021 · Cited by 9
Metadata
- Authors
- Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G.
- Venue
- Reports on Progress in Physics
- Publisher
- IOP Publishing
- Published
- 2010-06-02
- Volume
- 73
- Issue
- 7
- Pages
- 076701
- ISSN
- 0034-4885 (ISSN-L)
- 1361-6633
- OpenAlex
- W2061135416
- Cited by
- 1,161
- References
- 311
- FWCI
- 24.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.