The determination of atomic force microscope cantilever spring constants via dimensional methods for nanomechanical analysis
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Many papers have been published on methods to determine the normal spring constant, k z , of atomic force microscope (AFM) cantilevers. This is necessary to calibrate force measurements in the AFM, which then lead to a wide variety of applications from measuring the rupture force of protein bonds to determining the Young's modulus of materials such as polymers at surfaces. Manufacturers' nominal values of k z have been found to be up a factor of two in error, therefore practical methods to calibrate k z are required. There are three main categories of methods, with some overlap, which we call: (1) dimensional, (2) static experimental and (3) dynamic experimental. Here, we consider the dimensional aspects of these methods involving the cantilever material properties and geometry. We do this via reviewing the analytical equations of seven publications and comparing them with finite element analysis (FEA) calculations. It is shown that the best analytical equations are those of Neumeister and Ducker but that these need a revision for the bending of the triangular portion of the V-shaped cantilever. This is done and the correlation with FEA is then excellent. Equations are also provided for the effect of a metallized layer and the imaging tip not being at the cantilever apex; these also agree with FEA. We evaluate the relevant uncertainties and provide recommendations as to the best equations to use together with relevant correction parameters based on the assumption that the FEA calculations are valid. We test this assumption elsewhere.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Calibration of rectangular atomic force microscope cantilevers
Sader, J. E., Chon, J. W. M., & Mulvaney, P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150021 · Cited by 2,145
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Method for the calibration of atomic force microscope cantilevers
Sader, J. E., Larson, I., Mulvaney, P., & White, L. R. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145439 · Cited by 1,000
Mechanical Vibrations: Modeling and Measurement
Schmitz, T. L., & Smith, S. (2011) · Springer eBooks · doi:10.1007/978-1-4614-0460-6 · Cited by 903
Mechanical unfolding intermediates in titin modules
Marszalek, P. E., Lu, H., Li, H., Carrion-Vazquez, M., Oberhauser, A. F., Schulten, K., & Fernandez, J. M. (1999) · Nature · doi:10.1038/47083 · Cited by 798
Microfabrication of cantilever styli for the atomic force microscope
Albrecht, T. R., Akamine, S., Carver, T. E., & Quate, C. F. (1990) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.576520 · Cited by 747
Mechanical Properties of Matter
THOMPSON, F. C. (1965) · Nature · doi:10.1038/205219b0 · Cited by 546
Short cantilevers for atomic force microscopy
Walters, D. A., Cleveland, J. P., Thomson, N. H., Hansma, P. K., Wendman, M. A., Gurley, G., & Elings, V. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147177 · Cited by 494
Comparison of calibration methods for atomic-force microscopy cantilevers
Burnham, N. A., Chen, X., Hodges, C. S., Matei, G. A., Thoreson, E. J., Roberts, C. J., Davies, M. C., & Tendler, S. J. B. (2003) · Nanotechnology · doi:10.1088/0957-4484/14/1/301 · Cited by 458
Mechanical Stability of Single DNA Molecules
Clausen-Schaumann, H., Rief, M., Tolksdorf, C., & Gaub, H. E. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76747-6 · Cited by 437
Lateral, normal, and longitudinal spring constants of atomic force microscopy cantilevers
Neumeister, J. M., & Ducker, W. A. (1994) · Review of Scientific Instruments · doi:10.1063/1.1144646 · Cited by 334
Formulas for stress and strain
Roark, R. J. (1965) · CERN Document Server (European Organization for Nuclear Research) · Cited by 328
Theoretical analysis of the static deflection of plates for atomic force microscope applications
Sader, J. E., & White, L. (1993) · Journal of Applied Physics · doi:10.1063/1.354137 · Cited by 268
Parallel beam approximation for V-shaped atomic force microscope cantilevers
Sader, J. E. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145292 · Cited by 260
Scan speed limit in atomic force microscopy
BUTT, H. ‐., SIEDLE, P., SEIFERT, K., FENDLER, K., SEEGER, T., BAMBERG, E., WEISENHORN, A. L., GOLDIE, K., & ENGEL, A. (1993) · Journal of Microscopy · doi:10.1111/j.1365-2818.1993.tb03280.x · Cited by 233
Biomolecular Interactions Measured by Atomic Force Microscopy
Willemsen, O. H., Snel, M. M. E., Cambi, A., Greve, J., De Grooth, B. G., & Figdor, C. G. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76559-3 · Cited by 231
Experimental Determination of Spring Constants in Atomic Force Microscopy
Senden, T., & Ducker, W. (1994) · Langmuir · doi:10.1021/la00016a600 · Cited by 205
Characterization of application-specific probes for SPMs:
Tortonese, M., & Kirk, M. (1997) · SPIE Proceedings · doi:10.1117/12.271229 · Cited by 181
Spring constants of composite ceramic/gold cantilevers for scanning probe microscopy
Hazel, J. L., & Tsukruk, V. V. (1999) · Thin Solid Films · doi:10.1016/s0040-6090(98)00961-4 · Cited by 117
Friction effects in the deflection of atomic force microscope cantilevers
Warmack, R. J. B., Zheng, X.-J., Thundat, T. G., & Allison, D. P. (1994) · Review of Scientific Instruments · doi:10.1063/1.1145144 · Cited by 108
Holbery, J. D., Eden, V. L., Sarıkaya, M., & Fisher, R. M. (2000) · Review of Scientific Instruments · doi:10.1063/1.1289509 · Cited by 81
Hazel, J. L., & Tsukruk, V. V. (1998) · Journal of Tribology · doi:10.1115/1.2833784 · Cited by 80
Susceptibility of atomic force microscope cantilevers to lateral forces
Sader, J. E. (2003) · Review of Scientific Instruments · doi:10.1063/1.1544421 · Cited by 79
Cumpson, P. J., & Hedley, J. (2003) · Nanotechnology · doi:10.1088/0957-4484/14/12/009 · Cited by 76
Cumpson, P. J., Hedley, J., & Zhdan, P. A. (2003) · Nanotechnology · doi:10.1088/0957-4484/14/8/314 · Cited by 71
Degertekin, F. L., Hadimioglu, B. B., Sulchek, T., & Quate, C. F. (2001) · Applied Physics Letters · doi:10.1063/1.1354157 · Cited by 59
Gibson, C. T., Weeks, B. L., Lee, J. R. I., Abell, C., & Rayment, T. (2001) · Review of Scientific Instruments · doi:10.1063/1.1361080 · Cited by 47
Cited by
LaFratta, C. N., Fourkas, J. T., Baldacchini, T., & Farrer, R. A. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603995 · Cited by 589
Mechanical Properties of Collagen Fibrils
Wenger, M. P. E., Bozec, L., Horton, M. A., & Mesquida, P. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.103192 · Cited by 566
Dokukin, M. E., & Sokolov, I. (2012) · Langmuir · doi:10.1021/la302706b · Cited by 385
Spring constant calibration of atomic force microscope cantilevers of arbitrary shape
Sader, J. E., Sanelli, J. A., Adamson, B. D., Monty, J. P., Wei, X., Crawford, S. A., Friend, J. R., Marusic, I., Mulvaney, P., & Bieske, E. J. (2012) · Review of Scientific Instruments · doi:10.1063/1.4757398 · Cited by 283
Cannara, R. J., Eglin, M., & Carpick, R. W. (2006) · Review of Scientific Instruments · doi:10.1063/1.2198768 · Cited by 214
Metadata
- Authors
- Clifford, C. A., & Seah, M. P.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2005-07-06
- Volume
- 16
- Issue
- 9
- Pages
- 1666-1680
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W2087820727
- Cited by
- 181
- References
- 28
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.