Flexible, high-resolution thin-film electrodes for human and animal neural research
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Objective. Brain functions such as perception, motor control, learning, and memory arise from the coordinated activity of neuronal assemblies distributed across multiple brain regions. While major progress has been made in understanding the function of individual neurons, circuit interactions remain poorly understood. A fundamental obstacle to deciphering circuit interactions is the limited availability of research tools to observe and manipulate the activity of large, distributed neuronal populations in humans. Here we describe the development, validation, and dissemination of flexible, high-resolution, thin-film (TF) electrodes for recording neural activity in animals and humans. Approach. We leveraged standard flexible printed-circuit manufacturing processes to build high-resolution TF electrode arrays. We used biocompatible materials to form the substrate (liquid crystal polymer; LCP), metals (Au, PtIr, and Pd), molding (medical-grade silicone), and 3D-printed housing (nylon). We designed a custom, miniaturized, digitizing headstage to reduce the number of cables required to connect to the acquisition system and reduce the distance between the electrodes and the amplifiers. A custom mechanical system enabled the electrodes and headstages to be pre-assembled prior to sterilization, minimizing the setup time required in the operating room. PtIr electrode coatings lowered impedance and enabled stimulation. High-volume, commercial manufacturing enables cost-effective production of LCP-TF electrodes in large quantities. Main Results . Our LCP-TF arrays achieve 25× higher electrode density, 20× higher channel count, and 11× reduced stiffness than conventional clinical electrodes. We validated our LCP-TF electrodes in multiple human intraoperative recording sessions and have disseminated this technology to >10 research groups. Using these arrays, we have observed high-frequency neural activity with sub-millimeter resolution. Significance. Our LCP-TF electrodes will advance human neuroscience research and improve clinical care by enabling broad access to transformative, high-resolution electrode arrays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
Fully integrated silicon probes for high-density recording of neural activity
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., et al. (2017) · Nature · doi:10.1038/nature24636 · Cited by 2,190
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136
Self-citationNeuroGrid: recording action potentials from the surface of the brain
Khodagholy, D., Gelinas, J. N., Thesen, T., Doyle, W., Devinsky, O., Malliaras, G. G., & Buzsáki, G. (2015) · Nature Neuroscience · doi:10.1038/nn.3905 · Cited by 938
Self-citationRay, S., Crone, N. E., Niebur, E., Franaszczuk, P. J., & Hsiao, S. S. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.2848-08.2008 · Cited by 722
Long-term treatment with responsive brain stimulation in adults with refractory partial seizures
Bergey, G. K., Morrell, M. J., Mizrahi, E. M., Goldman, A., King-Stephens, D., Nair, D., Srinivasan, S., Jobst, B., Gross, R. E., Shields, D. C., et al. (2015) · Neurology · doi:10.1212/wnl.0000000000001280 · Cited by 634
Induced electrocorticographic gamma activity during auditory perception
Crone, N. E., Boatman, D., Gordon, B., & Hao, L. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00545-9 · Cited by 494
Tissue damage thresholds during therapeutic electrical stimulation
Cogan, S. F., Ludwig, K. A., Welle, C. G., & Takmakov, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/021001 · Cited by 386
Sensory–motor transformations for speech occur bilaterally
Cogan, G. B., Thesen, T., Carlson, C., Doyle, W., Devinsky, O., & Pesaran, B. (2014) · Nature · doi:10.1038/nature12935 · Cited by 273
Self-citationDynamic Stimulation of Visual Cortex Produces Form Vision in Sighted and Blind Humans
Beauchamp, M. S., Oswalt, D., Sun, P., Foster, B. L., Magnotti, J. F., Niketeghad, S., Pouratian, N., Bosking, W. H., & Yoshor, D. (2020) · Cell · doi:10.1016/j.cell.2020.04.033 · Cited by 257
Decoding spoken words using local field potentials recorded from the cortical surface
Kellis, S., Miller, K., Thomson, K., Brown, R., House, P., & Greger, B. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056007 · Cited by 235
Towards reconstructing intelligible speech from the human auditory cortex
Akbari, H., Khalighinejad, B., Herrero, J. L., Mehta, A. D., & Mesgarani, N. (2019) · Scientific Reports · doi:10.1038/s41598-018-37359-z · Cited by 221
Flexible Neural Electrode Array Based-on Porous Graphene for Cortical Microstimulation and Sensing
Lu, Y., Lyu, H., Richardson, A. G., Lucas, T. H., & Kuzum, D. (2016) · Scientific Reports · doi:10.1038/srep33526 · Cited by 213
Chiang, C.-H., Won, S. M., Orsborn, A. L., Yu, K. J., Trumpis, M., Bent, B., Wang, C., Xue, Y., Min, S., Woods, V., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay4682 · Cited by 211
Self-citationLe Van Quyen, M., Staba, R., Bragin, A., Dickson, C., Valderrama, M., Fried, I., & Engel, J. (2010) · Journal of Neuroscience · doi:10.1523/jneurosci.5049-09.2010 · Cited by 189
Rao, V. R., Sellers, K. K., Wallace, D. L., Lee, M. B., Bijanzadeh, M., Sani, O. G., Yang, Y., Shanechi, M. M., Dawes, H. E., & Chang, E. F. (2018) · Current Biology · doi:10.1016/j.cub.2018.10.026 · Cited by 181
Optogenetics through windows on the brain in the nonhuman primate
Ruiz, O., Lustig, B. R., Nassi, J. J., Cetin, A., Reynolds, J. H., Albright, T. D., Callaway, E. M., Stoner, G. R., & Roe, A. W. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00153.2013 · Cited by 132 · cited 1×
“For LCP-TF electrodes used in human intraoperative research, we have molded the electrode in medical grade silicone (MDX4-4210, Dow Corning) to provide soft, rounded edges [33, 45, 46], reducing the possibility of the thin LCP edges damaging the cortex during surgical placement.”
Long-term recording reliability of liquid crystal polymer µ ECoG arrays
Woods, V., Trumpis, M., Bent, B., Palopoli-Trojani, K., Chiang, C.-H., Wang, C., Yu, C., Insanally, M. N., Froemke, R. C., & Viventi, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae39d · Cited by 63
Self-citationPothof, F., Bonini, L., Lanzilotto, M., Livi, A., Fogassi, L., Orban, G. A., Paul, O., & Ruther, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046006 · Cited by 56 · cited 1×
“As a proof of concept, we have developed a 61ch LCP-TF SEEG electrode that included both micro-and macroelectrodes, similar to other efforts [64].”
Cited by
Human brain mapping with multithousand-channel PtNRGrids resolves spatiotemporal dynamics
Tchoe, Y., Bourhis, A. M., Cleary, D. R., Stedelin, B., Lee, J., Tonsfeldt, K. J., Brown, E. C., Siler, D. A., Paulk, A. C., Yang, J. C., et al. (2022) · Science Translational Medicine · doi:10.1126/scitranslmed.abj1441 · Cited by 135
High-resolution neural recordings improve the accuracy of speech decoding
Duraivel, S., Rahimpour, S., Chiang, C.-H., Trumpis, M., Wang, C., Barth, K., Harward, S. C., Lad, S. P., Friedman, A. H., Southwell, D. G., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-42555-1 · Cited by 75
Self-citationSun, J., Barth, K., Qiao, S., Chiang, C.-H., Wang, C., Rahimpour, S., Trumpis, M., Duraivel, S., Dubey, A., Wingel, K. E., et al. (2022) · Brain Communications · doi:10.1093/braincomms/fcac122 · Cited by 31
Self-citationThe Layer 7 Cortical Interface: A Scalable and Minimally Invasive Brain–Computer Interface Platform
Hettick, M., Ho, E., Poole, A. J., Monge, M., Papageorgiou, D., Takahashi, K., LaMarca, M., Trietsch, D., Reed, K., Murphy, M., et al. (2022) · doi:10.1101/2022.01.02.474656 · Cited by 31
“For this reason, non-penetrating cortical surface microelectrodes represent a potentially attractive alternative 69,79,80 .”
BackgroundHigh-Density, Actively Multiplexed µECoG Array on Reinforced Silicone Substrate
Rachinskiy, I., Wong, L., Chiang, C.-H., Wang, C., Trumpis, M., Ogren, J. I., Hu, Z., McLaughlin, B., & Viventi, J. (2022) · Frontiers in Nanotechnology · doi:10.3389/fnano.2022.837328 · Cited by 14
Self-citation
Metadata
- Authors
- Chiang, C.-H., Wang, C., Barth, K., Rahimpour, S., Trumpis, M., Duraivel, S., Rachinskiy, I., Dubey, A., Wingel, K. E., Wong, M., Witham, N. S., Odell, T., Woods, V., Bent, B., Doyle, W., Friedman, D., Bihler, E., Reiche, C. F., Southwell, D. G., Haglund, M. M., Friedman, A. H., Lad, S. P., Devore, S., Devinsky, O., Solzbacher, F., Pesaran, B., Cogan, G., & Viventi, J.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2021-06-17
- Volume
- 18
- Issue
- 4
- Pages
- 045009
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W3160162593
- Cited by
- 49
- References
- 19
- FWCI
- 3.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.