Histological evaluation of a chronically-implanted electrocorticographic electrode grid in a non-human primate
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Electrocorticography (ECoG), used as a neural recording modality for brain-machine interfaces (BMIs), potentially allows for field potentials to be recorded from the surface of the cerebral cortex for long durations without suffering the host-tissue reaction to the extent that it is common with intracortical microelectrodes. Though the stability of signals obtained from chronically implanted ECoG electrodes has begun receiving attention, to date little work has characterized the effects of long-term implantation of ECoG electrodes on underlying cortical tissue. APPROACH: We implanted and recorded from a high-density ECoG electrode grid subdurally over cortical motor areas of a Rhesus macaque for 666 d. MAIN RESULTS: Histological analysis revealed minimal damage to the cortex underneath the implant, though the grid itself was encapsulated in collagenous tissue. We observed macrophages and foreign body giant cells at the tissue-array interface, indicative of a stereotypical foreign body response. Despite this encapsulation, cortical modulation during reaching movements was observed more than 18 months post-implantation. SIGNIFICANCE: These results suggest that ECoG may provide a means by which stable chronic cortical recordings can be obtained with comparatively little tissue damage, facilitating the development of clinically viable BMI systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“Brain-machine interfaces (BMIs) utilize cortical signals to directly control external devices for restoration of motor function in individuals with disabilities (Wolpaw et al 2002, Leuthardt et al 2006, Schwartz et al 2006, Moran 2010).”
BackgroundForeign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138
Globally optimal stitching of tiled 3D microscopic image acquisitions
Preibisch, S., Saalfeld, S., & Tomancak, P. (2009) · Bioinformatics · doi:10.1093/bioinformatics/btp184 · Cited by 2,452
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Self-citationDissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465 · cited 2×
“It is possible that the persistent, unactivated microglia population was part of the foreign body response to the implanted ECoG array, where increased macrophage density persists in the vicinity of the implant for its lifetime (Sanders et al 2000, Anderson 2001).”
BackgroundResponsive cortical stimulation for the treatment of medically intractable partial epilepsy
Morrell, M. J. (2011) · Neurology · doi:10.1212/wnl.0b013e3182302056 · Cited by 1,282
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Self-citationFunctional organization of human sensorimotor cortex for speech articulation
Bouchard, K. E., Mesgarani, N., Johnson, K., & Chang, E. F. (2013) · Nature · doi:10.1038/nature11911 · Cited by 686
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Reconstructing Speech from Human Auditory Cortex
Pasley, B. N., David, S. V., Mesgarani, N., Flinker, A., Shamma, S. A., Crone, N. E., Knight, R. T., & Chang, E. F. (2012) · PLoS Biology · doi:10.1371/journal.pbio.1001251 · Cited by 604
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Emergence of a stable cortical map for neuroprosthetic control
Ganguly, K., & Carmena, J. M. (2009) · PLoS Biology · doi:10.1371/journal.pbio.1000153 · Cited by 578
Transcranial amelioration of inflammation and cell death after brain injury.
Roth, T. L., Nayak, D., Atanasijevic, T., Koretsky, A. P., Latour, L. L., & McGavern, D. B. (2014) · Nature · doi:10.1038/nature12808 · Cited by 574 · cited 2×
“It is also conceivable that this activation was not in response to a foreign body, but rather from pervasive mechanical stress caused by the fibrous encapsulation compressing the brain (Ding et al 2008, Roth et al 2014).”
BackgroundSimeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480
3-Dimensional imaging of collagen using second harmonic generation
Cox, G., Kable, E., Jones, A., Fraser, I., Manconi, F., & Gorrell, M. D. (2003) · Journal of Structural Biology · doi:10.1016/s1047-8477(02)00576-2 · Cited by 430
A MEMS-based flexible multichannel ECoG-electrode array
Rubehn, B., Bosman, C., Oostenveld, R., Fries, P., & Stieglitz, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/036003 · Cited by 387 · cited 1×
“…the shape of array substrate (Yamakwa et al 2010, Schendel et al 2013, Schendel et al 2014), increasing array flexibility (Yeager et al 2008, Rubehn et al 2009, Kim et al 2010), applying anti-fouling or biomimetic surface treatments (Collier et al 2004, Kolarcik et al 2012), and releasing…”
BackgroundChestek, C. A., Gilja, V., Nuyujukian, P., Foster, J. D., Fan, J. M., Kaufman, M. T., Churchland, M. M., Rivera-Alvidrez, Z., Cunningham, J. P., Ryu, S. I., et al. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/045005 · Cited by 350
Electrocorticographic control of a prosthetic arm in paralyzed patients
Yanagisawa, T., Hirata, M., Saitoh, Y., Kishima, H., Matsushita, K., Goto, T., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2012) · Annals of Neurology · doi:10.1002/ana.22613 · Cited by 256 · cited 1×
“…and nonhuman primate subjects have demonstrated up to threedimensional control of computer cursors or prosthetic limbs using ECoG (Leuthardt et al 2004, Wilson et al 2006, Schalk et al 2008, Leuthardt et al 2011, Schalk and Lethardt 2011, Yanagisawa et al 2012, Wang et al 2013, Hotson et al 2016).”
BackgroundImaging for the diagnosis and management of traumatic brain injury
Kim, J. J., & Gean, A. D. (2011) · Neurotherapeutics · doi:10.1007/s13311-010-0003-3 · Cited by 249
Pei, X., Barbour, D. L., Leuthardt, E. C., & Schalk, G. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046028 · Cited by 237 · cited 1×
“…et al 2013), as well as auditory (Edwards et al 2005, Trautner et al 2006), visual (Lachaux et al 2005), language (Crone et al 2001, Mainy et al 2007, Kellis et al 2010, Pei et al 2011, Wang et al 2011), and attentional processes (Tallon-Baudry et al 2005, Jung et al 2008, Ray et al 2008).”
BackgroundDecoding spoken words using local field potentials recorded from the cortical surface
Kellis, S., Miller, K., Thomson, K., Brown, R., House, P., & Greger, B. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056007 · Cited by 235 · cited 1×
“…et al 2013), as well as auditory (Edwards et al 2005, Trautner et al 2006), visual (Lachaux et al 2005), language (Crone et al 2001, Mainy et al 2007, Kellis et al 2010, Pei et al 2011, Wang et al 2011), and attentional processes (Tallon-Baudry et al 2005, Jung et al 2008, Ray et al 2008).”
BackgroundKozai, T. D. Y., Vazquez, A. L., Weaver, C. L., Kim, S.-G., & Cui, X. T. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066001 · Cited by 215
Self-citationHotson, G., McMullen, D. P., Fifer, M. S., Johannes, M. S., Katyal, K. D., Para, M. P., Armiger, R., Anderson, W. S., Thakor, N. V., Wester, B. A., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026017 · Cited by 201 · cited 1×
“…and nonhuman primate subjects have demonstrated up to threedimensional control of computer cursors or prosthetic limbs using ECoG (Leuthardt et al 2004, Wilson et al 2006, Schalk et al 2008, Leuthardt et al 2011, Schalk and Lethardt 2011, Yanagisawa et al 2012, Wang et al 2013, Hotson et al 2016).”
BackgroundTemporal progression of the host response to implanted poly(ethylene glycol)‐based hydrogels
Lynn, A. D., Blakney, A. K., Kyriakides, T. R., & Bryant, S. J. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.33015 · Cited by 77
Kolarcik, C. L., Bourbeau, D., Azemi, E., Rost, E., Zhang, L., Lagenaur, C. F., Weber, D. J., & Cui, X. T. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.06.034 · Cited by 59 · cited 1×
“…increasing array flexibility (Yeager et al 2008, Rubehn et al 2009, Kim et al 2010), applying anti-fouling or biomimetic surface treatments (Collier et al 2004, Kolarcik et al 2012), and releasing anti-inflammatory drugs from the array substrate or electrodes (Norton et al 2005, Weaver et al 2014).”
BackgroundSelf-citationBrodbeck, W. G., Shive, M. S., Colton, E., Ziats, N. P., & Anderson, J. M. (2002) · Journal of Laboratory and Clinical Medicine · doi:10.1067/mlc.2002.121260 · Cited by 52
Cited by
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Self-citationDegenhart, A. D., Bishop, W. E., Oby, E. R., Tyler-Kabara, E. C., Chase, S. M., Batista, A. P., & Yu, B. M. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0542-9 · Cited by 212
Self-citationPlug-and-play control of a brain–computer interface through neural map stabilization
Silversmith, D. B., Abiri, R., Hardy, N. F., Natraj, N., Tu-Chan, A., Chang, E. F., & Ganguly, K. (2021) · Nature Biotechnology · doi:10.1038/s41587-020-0662-5 · Cited by 126
The Future of Neuroimplantable Devices: A Materials Science and Regulatory Perspective
Obidin, N., Tasnim, F., & Dagdeviren, C. (2020) · Advanced Materials · doi:10.1002/adma.201901482 · Cited by 126
Brain-Computer Interface: Applications to Speech Decoding and Synthesis to Augment Communication
Luo, S., Rabbani, Q., & Crone, N. E. (2022) · Neurotherapeutics · doi:10.1007/s13311-022-01190-2 · Cited by 106
Metadata
- Authors
- Degenhart, A. D., Eles, J., Dum, R., Mischel, J. L., Smalianchuk, I., Endler, B., Ashmore, R. C., Tyler-Kabara, E. C., Hatsopoulos, N. G., Wang, W., Batista, A. P., & Cui, X. T.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-06-28
- Volume
- 13
- Issue
- 4
- Pages
- 046019
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2475055113
- Cited by
- 94
- References
- 30
- FWCI
- 3.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.