Thin microelectrodes reduce GFAP expression in the implant site in rodent somatosensory cortex
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The objective of this study was to test the hypothesis that neural implants with reduced cross-sectional areas will have less glial scarring associated with implantation injury in long-term experiments. In this study, we implanted nine adult rats with two different implants of 12 microm (n = 6), and 25 microm (n = 6) diameters (cross-sectional areas of 68 microm(2), 232 microm(2) respectively) and the expression of glial fibrilliary acidic protein (GFAP) was assessed after 2 weeks and 4 weeks of implantation. In order to facilitate implantation, the 12 microm diameter implants were coated with poly-glycolic acid (PGA), a biodegradable polymer that degraded within minutes of implantation. In n = 3 animals, 25 microm diameter implants also coated with PGA were implanted and assessed for GFAP expression at the end of 4 weeks of implantation. Statistical analysis of the GFAP expression around the different implants demonstrated that after 2 weeks of implantation there is no statistically significant difference in GFAP expression between the 12 microm and the 25 microm diameter implants. However, after 4 weeks of implantation the implant site of 12 microm diameter implants exhibited a statistically significant reduction in GFAP expression when compared to the implant sites of the 25 microm diameter implants (both with and without the PGA coating). We conclude that in neural implants that are tethered to the skull, implant cross-sectional areas of 68 microm(2) and smaller could lead to a reduced glial scarring under chronic conditions. Future studies with longer implant durations can confirm if this observation remains consistent beyond 4 weeks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Subbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368
Rousche, P. J., & Normann, R. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.750552 · Cited by 187
Ceramic-Based Multisite Electrode Arrays for Chronic Single-Neuron Recording
Moxon, K. A., Leiser, S., Gerhardt, G. A., Barbee, K. A., & Chapin, J. K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821037 · Cited by 129
Cited by
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“Of the contradicting studies, both Stice et al and Thelin et al provided evidence that changing device geometry and reducing presented surface area impact the neuro-inflammatory response [145, 240].”
ResultRelationship between intracortical electrode design and chronic recording function
Karumbaiah, L., Saxena, T., Carlson, D., Patil, K., Patkar, R., Gaupp, E. A., Betancur, M., Stanley, G. B., Carin, L., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.016 · Cited by 241
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
“It is generally admitted that a fine tip decreases tissue dimpling and vessel dragging [11, 183], and that probe dimension plays a major role in the reduction of shear force and inflammatory response [21, 87, 128].”
BackgroundChronic in vivo stability assessment of carbon fiber microelectrode arrays
Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066002 · Cited by 204
“an improved tissue response made use of hard materials, such as silicon [39, 40], and softer materials, such as SU-8 and parylene [38].”
BackgroundImplant Size and Fixation Mode Strongly Influence Tissue Reactions in the CNS
Thelin, J., Jörntell, H., Psouni, E., Garwicz, M., Schouenborg, J., Danielsen, N., & Linsmeier, C. E. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016267 · Cited by 191
“Most experimental rat studies uses rather short evaluation periods with an emphasis on the evaluation periods of 2–4 weeks [5,7,9,10,11], even though some studies have follow up periods up to 16 weeks [14].”
BackgroundResultFlexible, Penetrating Brain Probes Enabled by Advances in Polymer Microfabrication
Weltman, A., Yoo, J., & Meng, E. (2016) · Micromachines · doi:10.3390/mi7100180 · Cited by 184
“Another study of stainless steel microwires coated with poly-glycolic acid (PGA) to aid in insertion found that probes with a 12 μm diameter experienced a significant reduction in GFAP expression at four weeks post implantation into rats compared to 25 μm counterparts [109].”
BackgroundSzostak, K. M., Grand, L., & Constandinou, T. G. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00665 · Cited by 168
“…side, it is suggested that smaller geometries are beneficial and lead to reduction in glial fibrillary acidic protein (GFAP) expression over time (Stice et al., 2007; Kozai et al., 2012); while older studies indicate size reduction is beneficiary only initially, and does not influence the…”
BackgroundBiocompatibility of intracortical microelectrodes: current status and future prospects
Marin, C. (2010) · Frontier in Neuroengineering · doi:10.3389/fneng.2010.00008 · Cited by 160
“, 2010), polymers (Ludwig et al., 2006; Stice et al., 2007; Asplund et al., 2009; Richardson et al., 2009) and carbon nanotubes (Lovat et al.”
Ultra-thin flexible polyimide neural probe embedded in a dissolvable maltose-coated microneedle
Xiang, Z., Yen, S.-C., Xue, N., Sun, T., Tsang, W. M., Zhang, S., Liao, L.-D., Thakor, N. V., & Lee, C. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/6/065015 · Cited by 159
“Coating with biodegradable materials such as silk [54], poly-glycolic acid [55], polyethelene glycol [56] and poly(lactic-co-glycolic) [57] has become a popular approach to improve the stiffness since it is a simple process and does not need any modification of the probe structure.”
BackgroundTien, L. W., Wu, F., Tang‐Schomer, M. D., Yoon, E., Omenetto, F. G., & Kaplan, D. L. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201203716 · Cited by 136
Skousen, J. L., Merriam, S. M. E., Srivannavit, O., Perlin, G., Wise, K. D., & Tresco, P. A. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53815-4.00009-1 · Cited by 111
The density difference between tissue and neural probes is a key factor for glial scarring
Lind, G., Linsmeier, C. E., & Schouenborg, J. (2013) · Scientific Reports · doi:10.1038/srep02942 · Cited by 102
Amorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording
Deku, F., Cohen, Y., Joshi-Imre, A., Kanneganti, A., Gardner, T. J., & Cogan, S. F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8f8b · Cited by 89
Skousen, J. L., Bridge, M. J., & Tresco, P. A. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.039 · Cited by 61
Thinking Small: Progress on Microscale Neurostimulation Technology
Pancrazio, J. J., Deku, F., Ghazavi, A., Stiller, A. M., Rihani, R., Frewin, C. L., Varner, V. D., Gardner, T. J., & Cogan, S. F. (2017) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12716 · Cited by 60
“compared the tissue response evoked by 12 and 25 lm diameter thin microelectrodes showing statistically significant reductions, although not elimination, in activated astrocyte staining for smaller diameter probes after 4 weeks implantation (44).”
Metadata
- Authors
- Stice, P., Gilletti, A., Panitch, A., & Muthuswamy, J.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2007-02-01
- Volume
- 4
- Issue
- 2
- Pages
- 42-53
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2085114419
- Cited by
- 96
- References
- 5
- FWCI
- 1.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.