Brain–computer interface using a simplified functional near-infrared spectroscopy system
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
A brain-computer interface (BCI) is a device that allows a user to communicate with external devices through thought processes alone. A novel signal acquisition tool for BCIs is near-infrared spectroscopy (NIRS), an optical technique to measure localized cortical brain activity. The benefits of using this non-invasive modality are safety, portability and accessibility. A number of commercial multi-channel NIRS system are available; however we have developed a straightforward custom-built system to investigate the functionality of a fNIRS-BCI system. This work describes the construction of the device, the principles of operation and the implementation of a fNIRS-BCI application, 'Mindswitch' that harnesses motor imagery for control. Analysis is performed online and feedback of performance is presented to the user. Mindswitch presents a basic 'on/off' switching option to the user, where selection of either state takes 1 min. Initial results show that fNIRS can support simple BCI functionality and shows much potential. Although performance may be currently inferior to many EEG systems, there is much scope for development particularly with more sophisticated signal processing and classification techniques. We hope that by presenting fNIRS as an accessible and affordable option, a new avenue of exploration will open within the BCI research community and stimulate further research in fNIRS-BCIs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“for harnessing such tasks for BCI development [1, 5–8].”
MethodBrain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Villringer, A., Planck, J., Hock, C., Schleinkofer, L., & Dirnagl, U. (1993) · Neuroscience Letters · doi:10.1016/0304-3940(93)90181-j · Cited by 1,119
Cope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
Non-invasive neuroimaging using near-infrared light
Strangman, G., Boas, D. A., & Sutton, J. P. (2002) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01550-0 · Cited by 903
Neuper, C., Scherer, R., Reiner, M., & Pfurtscheller, G. (2005) · Cognitive Brain Research · doi:10.1016/j.cogbrainres.2005.08.014 · Cited by 721
Sitaram, R., Zhang, H., Guan, C., Thulasidas, M., Hoshi, Y., Ishikawa, A., Shimizu, K., & Birbaumer, N. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.005 · Cited by 590
Strangman, G., Franceschini, M. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00021-1 · Cited by 581
Brain-computer communication: Unlocking the locked in.
Kübler, A., Kotchoubey, B., Kaiser, J., Wolpaw, J. R., & Birbaumer, N. (2001) · Psychological Bulletin · doi:10.1037//0033-2909.127.3.358 · Cited by 553
Cited by
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“Head motions or hair obstruction can worsen performance and signal quality [91].”
BackgroundInfluentialfNIRS-based brain-computer interfaces: a review
Naseer, N., & Hong, K.-S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00003 · Cited by 988
“The motor imagery tasks include imagination of the squeezing of a soft ball (Coyle et al., 2004, 2007; Stangl et al., 2013), covert imagery of a simple or complex sequence of finger tapping (Sitaram et al., 2007; Holper and Wolf, 2011), imagination of feet tapping (Kaiser et al., 2014), imagination…”
BackgroundMethodInfluentialA quantitative comparison of NIRS and fMRI across multiple cognitive tasks
Cui, X., Bray, S., Bryant, D. M., Glover, G. H., & Reiss, A. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.069 · Cited by 945
Combining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
Cui, X., Bryant, D. M., & Reiss, A. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.003 · Cited by 807
“NIRS is a relatively flexible technology and to date has been successfully applied in several domains [22], including physiological mechanisms of the BOLD response [23-31], non-invasive brain-computer interfaces [32-36], and brain activity in both active tasks and resting states [37-42].”
Cui, X., Bray, S., & Reiss, A. L. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.050 · Cited by 807
Optical brain monitoring for operator training and mental workload assessment
Ayaz, H., Shewokis, P. A., Bunce, S., Izzetoglu, K., Willems, B., & Onaral, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.023 · Cited by 650
“fNIR is safe, highly portable, user-friendly and relatively inexpensive, with rapid application times and near-zero run-time costs (Bunce et al., 2006; Coyle et al., 2007; Izzetoglu et al., 2004; Strangman et al., 2002; Villringer and Chance, 1997).”
Pfurtscheller, G. (2010) · Frontiers in Neuroscience · doi:10.3389/fnpro.2010.00003 · Cited by 625
Enhanced performance by a hybrid NIRS–EEG brain computer interface
Fazli, S., Mehnert, J., Steinbrink, J., Curio, G., Villringer, A., Müller, K.-R., & Blankertz, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.084 · Cited by 599
Rehabilitation of gait after stroke: a review towards a top-down approach
Belda-Lois, J.-M., Mena-del Horno, S., Bermejo-Bosch, I., Moreno, J. C., Pons, J. L., Farina, D., Iosa, M., Molinari, M., Tamburella, F., Ramos, A., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-66 · Cited by 581
Brain-computer interfaces for communication and control
McFarland, D. J., & Wolpaw, J. R. (2011) · Communications of the ACM · doi:10.1145/1941487.1941506 · Cited by 519
Clinical Applications of Brain-Computer Interfaces: Current State and Future Prospects
Mak, J. N., & Wolpaw, J. R. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2035356 · Cited by 509
Mental workload during n-back task—quantified in the prefrontal cortex using fNIRS
Herff, C., Heger, D., Fortmann, O., Hennrich, J., Putze, F., & Schultz, T. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00935 · Cited by 365
Naseer, N., & Hong, K.-S. (2013) · Neuroscience Letters · doi:10.1016/j.neulet.2013.08.021 · Cited by 301
Decoding of four movement directions using hybrid NIRS-EEG brain-computer interface
Khan, M. J., Hong, M. J., & Hong, K.-S. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00244 · Cited by 280
Classification of prefrontal and motor cortex signals for three-class fNIRS-BCI
Hong, K.-S., Naseer, N., & Kim, Y.-H. (2015) · Neuroscience Letters · doi:10.1016/j.neulet.2014.12.029 · Cited by 276
“This is usually done by performing different mental tasks, such as motor imagery [5,7,32], mental singing [6,9,11], mental arithmetic [9,11,16], and others [6].”
BackgroundNoninvasive Brain-Computer Interfaces Based on Sensorimotor Rhythms
He, B., Baxter, B., Edelman, B. J., Cline, C. C., & Ye, W. W. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2407272 · Cited by 233
“[22] Y. Tomita, F.-B. Vialatte, G. Dreyfus, Y. Mitsukura, H. Bakardjian, and A. Cichocki, ‘‘Bimodal BCI using simultaneously NIRS and EEG,’’ IEEE Trans.”
Naseer, N., Hong, M. J., & Hong, K.-S. (2014) · Experimental Brain Research · doi:10.1007/s00221-013-3764-1 · Cited by 228
Passive BCI based on drowsiness detection: an fNIRS study
Khan, M. J., & Hong, K.-S. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.004063 · Cited by 209
Jahani, S., Setarehdan, S. K., Boas, D. A., & Yücel, M. A. (2018) · Neurophotonics · doi:10.1117/1.nph.5.1.015003 · Cited by 208
“Ideally, motion artifacts should be avoided in the first place using various methods such as by stabilizing the optodes by gluing them on the scalp(10) or using a mechanical mounting structure to carry the weight of the optodes.(11,12) Auxiliary measurements, such as accelerometer, can also be used to regress out the…”
MethodUsing MazeSuite and Functional Near Infrared Spectroscopy to Study Learning in Spatial Navigation
Ayaz, H., Shewokis, P. A., Curtin, A., Izzetoglu, M., Izzetoglu, K., & Onaral, B. (2011) · Journal of Visualized Experiments · doi:10.3791/3443 · Cited by 203
Hybrid EEG-fNIRS Asynchronous Brain-Computer Interface for Multiple Motor Tasks
Buccino, A. P., Keles, H. O., & Omurtag, A. (2016) · PLOS ONE · doi:10.1371/journal.pone.0146610 · Cited by 183
Neurotechnologies for Human Cognitive Augmentation: Current State of the Art and Future Prospects
Cinel, C., Valeriani, D., & Poli, R. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00013 · Cited by 178
“These have made this technology suitable for human cognitive augmentation applications (Coyle et al., 2007; Ayaz et al., 2013; McKendrick et al., 2014; Naseer and Hong, 2015), especially when paired with brain stimulation technologies, for example, to enhance spatial working memory (McKendrick et al.”
BackgroundDecoding Individual Finger Movements from One Hand Using Human EEG Signals
Liao, K., Xiao, R., Gonzalez, J., & Ding, L. (2014) · PLoS ONE · doi:10.1371/journal.pone.0085192 · Cited by 174
“Various brain signals have been adopted in BCI, including electroencephalography (EEG) [5,6], electrocorticography (ECoG) [7,8], electromyography (EMG) [9,10], functional magnetic resonance imaging (fMRI) [11,12], magnetoencephalography (MEG) [13], and near-infrared spectroscopy (NIRS) [14].”
MethodReal-Time State Estimation in a Flight Simulator Using fNIRS
Gateau, T., Durantin, G., Lancelot, F., Scannella, S., & Dehais, F. (2015) · PLOS ONE · doi:10.1371/journal.pone.0121279 · Cited by 167
“However, fNIRS has been proven to be a suitable technique for BCI purposes [26–30] although most of the demonstrations were achieved in an off-line manner (e.”
MethodDifferential evolution algorithm as a tool for optimal feature subset selection in motor imagery EEG
Baig, M. Z., Aslam, N., Shum, H. P. H., & Zhang, L. (2017) · Expert Systems with Applications · doi:10.1016/j.eswa.2017.07.033 · Cited by 167
Filtering techniques for channel selection in motor imagery EEG applications: a survey
Baig, M. Z., Aslam, N., & Shum, H. P. H. (2020) · Artificial Intelligence Review · doi:10.1007/s10462-019-09694-8 · Cited by 160
“Electroencephalography (EEG) (Schalk et al. 2004), magnetoencephalography (MEG) (Lal et al. 2005), Functional Magnetic Resonance Imaging (fMRI) (Weiskopf et al. 2004) and Near Infra-red Spectroscopy (NIRS) (Coyle et al. 2007) are examples of noninvasive inputs .”
BackgroundInfluentialPower, S. D., Falk, T. H., & Chau, T. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026002 · Cited by 158
“Measuring functional activity via the PFC rather than the motor cortex is also advantageous in that signal attenuation and motion artefacts due to hair, which have been reported to be the primary factor in system performance degradation [20], are mitigated.”
BackgroundMethodResultInfluentialTranslating the Brain-Machine Interface
Thakor, N. V. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007303 · Cited by 128
Brainput: enhancing interactive systems with streaming fnirs brain input
Solovey, E., Schermerhorn, P., Scheutz, M., Sassaroli, A., Fantini, S., & Jacob, R. (2012) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/2207676.2208372 · Cited by 86
“There have been early demonstrations that fNIRS signals could be sent in realtime from hardware to a user interface [3, 6].”
BackgroundYücel, M. A., Selb, J., Boas, D. A., Cash, S. S., & Cooper, R. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.054 · Cited by 86
“Another approach is to use a mechanical mounting structure to carry the weight of the optodes (Coyle et al., 2007; Giacometti and Diamond, 2013).”
Metadata
- Authors
- Coyle, S. M., Ward, T. E., & Markham, C. M.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2007-04-27
- Volume
- 4
- Issue
- 3
- Pages
- 219-226
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2104946207
- Cited by
- 505
- References
- 26
- FWCI
- 9.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.