Rapid 3D printing of anatomically accurate and mechanically heterogeneous aortic valve hydrogel scaffolds
Open accessThe DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
The aortic valve exhibits complex three-dimensional (3D) anatomy and heterogeneity essential for the long-term efficient biomechanical function. These are, however, challenging to mimic in de novo engineered living tissue valve strategies. We present a novel simultaneous 3D printing/photocrosslinking technique for rapidly engineering complex, heterogeneous aortic valve scaffolds. Native anatomic and axisymmetric aortic valve geometries (root wall and tri-leaflets) with 12-22 mm inner diameters (ID) were 3D printed with poly-ethylene glycol-diacrylate (PEG-DA) hydrogels (700 or 8000 MW) supplemented with alginate. 3D printing geometric accuracy was quantified and compared using Micro-CT. Porcine aortic valve interstitial cells (PAVIC) seeded scaffolds were cultured for up to 21 days. Results showed that blended PEG-DA scaffolds could achieve over tenfold range in elastic modulus (5.3±0.9 to 74.6±1.5 kPa). 3D printing times for valve conduits with mechanically contrasting hydrogels were optimized to 14 to 45 min, increasing linearly with conduit diameter. Larger printed valves had greater shape fidelity (93.3±2.6, 85.1±2.0 and 73.3±5.2% for 22, 17 and 12 mm ID porcine valves; 89.1±4.0, 84.1±5.6 and 66.6±5.2% for simplified valves). PAVIC seeded scaffolds maintained near 100% viability over 21 days. These results demonstrate that 3D hydrogel printing with controlled photocrosslinking can rapidly fabricate anatomical heterogeneous valve conduits that support cell engraftment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix elasticity directs stem cell lineage specification
Engler, A. J., Sen, S., Sweeney, H. L., & Discher, D. E. (2006) · Cell · doi:10.1016/j.cell.2006.06.044 · Cited by 13,915
The incidence of congenital heart disease.
Hoffman, J. I. E., & Kaplan, S. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01886-7 · Cited by 6,099
Porous scaffold design for tissue engineering
Hollister, S. J. (2005) · Nature Materials · doi:10.1038/nmat1421 · Cited by 3,969
Alginate hydrogels as synthetic extracellular matrix materials
Rowley, J. A., Madlambayan, G., & Mooney, D. J. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00107-0 · Cited by 2,342
Harnessing traction-mediated manipulation of the cell/matrix interface to control stem-cell fate
Huebsch, N., Arany, P. R., Mao, A. S., Shvartsman, D., Ali, O. A., Bencherif, S. A., Rivera-Feliciano, J., & Mooney, D. J. (2010) · Nature Materials · doi:10.1038/nmat2732 · Cited by 1,569
Bryant, S. J., & Anseth, K. S. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1217 · Cited by 845
Gauvin, R., Chen, Y.-C., Lee, J. W., Soman, P., Zorlutuna, P., Nichol, J. W., Bae, H., Chen, S., & Khademhosseini, A. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.01.048 · Cited by 641
Prosthesis-patient mismatch: definition, clinical impact, and prevention
Pibarot, P., & Dumesnil, J. G. (2006) · Heart · doi:10.1136/hrt.2005.067363 · Cited by 606
Dynamic Mechanical Conditioning of Collagen-Gel Blood Vessel Constructs Induces Remodeling In Vitro
Seliktar, D., Black, R. A., Vito, R. P., & Nerem, R. M. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.275 · Cited by 555
Mechanical Properties of Cellularly Responsive Hydrogels and Their Experimental Determination
Kloxin, A. M., Kloxin, C. J., Bowman, C. N., & Anseth, K. S. (2010) · Advanced Materials · doi:10.1002/adma.200904179 · Cited by 481
Chan, V., Zorlutuna, P., Jeong, J. H., Kong, H., & Bashir, R. (2010) · Lab on a Chip · doi:10.1039/c004285d · Cited by 468
Photocrosslinkable Hyaluronan-Gelatin Hydrogels for Two-Step Bioprinting
Skardal, A., Zhang, J., McCoard, L., Xu, X., Oottamasathien, S., & Prestwich, G. D. (2010) · Tissue Engineering Part A · doi:10.1089/ten.tea.2009.0798 · Cited by 424
Scaffolding In Tissue Engineering
(2005) · CRC Press eBooks · doi:10.1201/9781420027563 · Cited by 404
Fedorovich, N. E., Schuurman, W., Wijnberg, H. M., Prins, H.-J., van Weeren, P. R., Malda, J., Alblas, J., & Dhert, W. J. A. (2012) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2011.0060 · Cited by 403
Three-Dimensional Photopatterning of Hydrogels Containing Living Cells
Liu, V. A., & Bhatia, S. N. (2002) · Biomedical Microdevices · doi:10.1023/a:1020932105236 · Cited by 399
Dhariwala, B., Hunt, E., & Boland, T. (2004) · Tissue Engineering · doi:10.1089/1076327042500256 · Cited by 389
Arcaute, K., Mann, B. K., & Wicker, R. B. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9156-y · Cited by 364
Direct Freeform Fabrication of Seeded Hydrogels in Arbitrary Geometries
Cohen, D. L., Malone, E., Lipson, H., & Bonassar, L. J. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.1325 · Cited by 360
Self-citationPeyton, S. R., Raub, C. B., Keschrumrus, V. P., & Putnam, A. J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.05.012 · Cited by 357
Scaffold‐free inkjet printing of three‐dimensional zigzag cellular tubes
Xu, C., Chai, W., Huang, Y., & Markwald, R. R. (2012) · Biotechnology and Bioengineering · doi:10.1002/bit.24591 · Cited by 357
Benton, J. A., DeForest, C. A., Vivekanandan, V., & Anseth, K. S. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0545 · Cited by 349
Early In Vivo Experience With Tissue-Engineered Trileaflet Heart Valves
Sodian, R., Hoerstrup, S. P., Sperling, J. S., Daebritz, S., Martin, D. P., Moran, A. M., Kim, B. S., Schoen, F. J., Vacanti, J. P., & Mayer, J. E. (2000) · Circulation · doi:10.1161/01.cir.102.suppl_3.iii-22 · Cited by 330
Fab@Home: the personal desktop fabricator kit
Malone, E., & Lipson, H. (2007) · Rapid Prototyping Journal · doi:10.1108/13552540710776197 · Cited by 322
Self-citationHutson, C. B., Nichol, J. W., Aubin, H., Bae, H., Yamanlar, S., Al-Haque, S., Koshy, S. T., & Khademhosseini, A. (2011) · Tissue Engineering Part A · doi:10.1089/ten.tea.2010.0666 · Cited by 303
From Stem Cells to Viable Autologous Semilunar Heart Valve
Sutherland, F. W. H., Perry, T. E., Yu, Y., Sherwood, M. C., Rabkin, E., Masuda, Y., Garcia, G. A., McLellan, D. L., Engelmayr, G. C., Sacks, M. S., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.498378 · Cited by 297
Butcher, J. T., Penrod, A. M., García, A. J., & Nerem, R. M. (2004) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000130462.50769.5a · Cited by 295
Self-citationFLUID MECHANICS OF ARTIFICIAL HEART VALVES
Dasi, L. P., Simon, H. A., Sucosky, P., & Yoganathan, A. P. (2009) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2008.05099.x · Cited by 286
Bioengineering Challenges for Heart Valve Tissue Engineering
Sacks, M. S., Schoen, F. J., & Mayer, J. E. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124903 · Cited by 256
3D Cell‐Migration Studies using Two‐Photon Engineered Polymer Scaffolds
Tayalia, P., Mendonca, C. R., Baldacchini, T., Mooney, D. J., & Mazur, E. (2008) · Advanced Materials · doi:10.1002/adma.200801319 · Cited by 253
Tissue-engineered heart valves. Autologous valve leaflet replacement study in a lamb model.
Shinoka, T., Ma, P. X., Shum‐Tim, D., Breuer, C. K., Cusick, R. A., Zünd, G., Langer, R., Vacanti, J. P., & Mayer, J. E. (1996) · PubMed · Cited by 246
Effect of substrate mechanics on chondrocyte adhesion to modified alginate surfaces
Genes, N. G., Rowley, J. A., Mooney, D. J., & Bonassar, L. J. (2004) · Archives of Biochemistry and Biophysics · doi:10.1016/j.abb.2003.11.023 · Cited by 227
Self-citationMinimally-Invasive Implantation of Living Tissue Engineered Heart Valves
Schmidt, D., Dijkman, P. E., Driessen-Mol, A., Stenger, R., Mariani, C., Puolakka, A., Rissanen, M., Deichmann, T., Odermatt, B., Weber, B., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.04.024 · Cited by 221
Aortic valve disease and treatment: The need for naturally engineered solutions
Butcher, J. T., Mahler, G. J., & Hockaday, L. A. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.008 · Cited by 210
Self-citationApplication of Stereolithography for Scaffold Fabrication for Tissue Engineered Heart Valves
Sodian, R., Loebe, M., Hein, A., Martin, D. P., Hoerstrup, S. P., Potapov, E. V., Hausmann, H., Lueth, T., & Hetzer, R. (2002) · ASAIO Journal · doi:10.1097/00002480-200201000-00004 · Cited by 206
Benton, J. A., Fairbanks, B. D., & Anseth, K. S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.08.031 · Cited by 206
Deformational Dynamics of the Aortic Root : Modes and Physiologic Determinants
Dagum, P., Green, G. R., Nistal, F. J., Daughters, G. T., Timek, T. A., Foppiano, L. E., Bolger, A. F., Ingels, N. B., & Miller, D. C. (1999) · Circulation · doi:10.1161/01.cir.100.suppl_2.ii-54 · Cited by 186
Hahn, M. S., McHale, M. K., Wang, E., Schmedlen, R. H., & West, J. L. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9099-3 · Cited by 185
Bowles, R. D., Williams, R. M., Zipfel, W. R., & Bonassar, L. J. (2010) · Tissue Engineering Part A · doi:10.1089/ten.tea.2009.0442 · Cited by 165
Self-citationFlanagan, T. C., Sachweh, J. S., Frese, J., Schnöring, H., Gronloh, N., Koch, S., Tolba, R. H., Schmitz-Rode, T., & Jockenhoevel, S. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2009.0018 · Cited by 160
Mechanobiology of the aortic heart valve.
Butcher, J. T., Simmons, C. A., & Warnock, J. N. (2008) · PubMed · Cited by 154
Self-citationSeliktar, D., Nerem, R. M., & Galis, Z. S. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1415522 · Cited by 149
In vivo monitoring of function of autologous engineered pulmonary valve
Gottlieb, D., Kunal, T., Emani, S., Aikawa, E., Brown, D. W., Powell, A. J., Nedder, A., Engelmayr, G. C., Melero-Martin, J. M., Sacks, M. S., et al. (2010) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2009.11.006 · Cited by 142
Hou, Y., Schoener, C. A., Regan, K. R., Munoz‐Pinto, D. J., Hahn, M. S., & Grunlan, M. A. (2010) · Biomacromolecules · doi:10.1021/bm9012293 · Cited by 134
Porous scaffold architecture guides tissue formation
Cipitria, A., Lange, C., Schell, H., Wagermaier, W., Reichert, J. C., Hutmacher, D. W., Fratzl, P., & Duda, G. N. (2012) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.1589 · Cited by 132
Ballyns, J. J., Gleghorn, J. P., Niebrzydowski, V., Rawlinson, J., Potter, H. G., Maher, S. A., Wright, T. M., & Bonassar, L. J. (2008) · Tissue Engineering Part A · doi:10.1089/ten.tea.2007.0186 · Cited by 130
Self-citationDevelopment of a Biostable Replacement for PEGDA Hydrogels
Browning, M. B., & Cosgriff‐Hernandez, E. (2012) · Biomacromolecules · doi:10.1021/bm201707z · Cited by 127
Robinson, P. S., Johnson, S. L., Evans, M. C., Barocas, V. H., & Tranquillo, R. T. (2008) · Tissue Engineering Part A · doi:10.1089/ten.a.2007.0148 · Cited by 125
Stiffness of photocrosslinked RGD‐alginate gels regulates adipose progenitor cell behavior
Chandler, E. M., Berglund, C. M., Lee, J. S., Polacheck, W. J., Gleghorn, J. P., Kirby, B. J., & Fischbach, C. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23079 · Cited by 109
Tissue-Engineered Valves with Commissural Alignment
Neidert, M. R., & Tranquillo, R. T. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.891 · Cited by 108
Compositional control of poly(ethylene glycol) hydrogel modulus independent of mesh size
Browning, M. B., Wilems, T. S., Hahn, M. S., & Cosgriff‐Hernandez, E. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.33109 · Cited by 105
Zhang, H., Wang, L., Li, S., Niu, G., Cao, H., Wang, G., Yang, H., & Zhu, S. (2011) · Journal of Applied Polymer Science · doi:10.1002/app.33653 · Cited by 93
Ramaswamy, S. D., Gottlieb, D., Engelmayr, G. C., Aïkawa, E., Schmidt, D. E., Gaitan-Leon, D. M., Sales, V. L., Mayer, J. E., & Sacks, M. S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.10.019 · Cited by 92
Guo, K., & Chu, C. C. (2005) · Journal of Polymer Science Part A Polymer Chemistry · doi:10.1002/pola.20781 · Cited by 88
Self-citationEndothelial Progenitor Cells as a Sole Source for Ex Vivo Seeding of Tissue-Engineered Heart Valves
Sales, V. L., Mettler, B. A., Engelmayr, G. C., Aikawa, E. R., Bischoff, J. E., Martin, D. P., Exarhopoulos, A., Moses, M. A., Schöen, F. J., Sacks, M. S., et al. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2009.0424 · Cited by 80
An approach to the optimization of preparation of bioprosthetic heart valves
Mavrilas, D., & Missirlis, Y. F. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90351-m · Cited by 74
Hypoxia Induces Near-Native Mechanical Properties in Engineered Heart Valve Tissue
Balguid, A., Mol, A., van Vlimmeren, M. A. A., Baaijens, F. F., & Bouten, C. V. C. (2009) · Circulation · doi:10.1161/circulationaha.107.749853 · Cited by 55
Ballyns, J. J., Cohen, D. L., Malone, E., Maher, S. A., Potter, H. G., Wright, T. M., Lipson, H., & Bonassar, L. J. (2009) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2009.0441 · Cited by 53
Self-citationGuo, K., & Chu, C. C. (2007) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856207780852569 · Cited by 51
Self-citationEckert, C. E., Mikulis, B. T., Gottlieb, D., Gerneke, D., LeGrice, I. J., Padera, R. F., Mayer, J. E., Schöen, F. J., & Sacks, M. S. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0162-8 · Cited by 32
Effect of Heparin Oligomer Chain Length on the Activation of Valvular Interstitial Cells
Pedrón, S., Kasko, A. M., Peinado, C., & Anseth, K. S. (2010) · Biomacromolecules · doi:10.1021/bm100211k · Cited by 6
Cited by
25th Anniversary Article: Engineering Hydrogels for Biofabrication
Malda, J., Visser, J., Melchels, F. P., Jüngst, T., Hennink, W. E., Dhert, W. J. A., Groll, J., & Hutmacher, D. W. (2013) · Advanced Materials · doi:10.1002/adma.201302042 · Cited by 1,901
Hinton, T. J., Jallerat, Q., Palchesko, R. N., Park, J. H., Grodzicki, M. S., Shue, H.-J., Ramadan, M. H., Hudson, A. R., & Feinberg, A. W. (2015) · Science Advances · doi:10.1126/sciadv.1500758 · Cited by 1,805
Current advances and future perspectives in extrusion-based bioprinting
Ozbolat, I. T., & Hospodiuk, M. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2015.10.076 · Cited by 1,572
The bioink: A comprehensive review on bioprintable materials
Hospodiuk, M., Dey, M., Sosnoski, D., & Ozbolat, I. T. (2017) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.12.006 · Cited by 1,118
Direct 3D Printing of Shear‐Thinning Hydrogels into Self‐Healing Hydrogels
Highley, C. B., Rodell, C. B., & Burdick, J. A. (2015) · Advanced Materials · doi:10.1002/adma.201501234 · Cited by 1,043
Metadata
- Authors
- Hockaday, L. A., Kang, K. H., Colangelo, N. W., Cheung, P. Y. C., Duan, B., Malone, E., Wu, J., Girardi, L. N., Bonassar, L. J., Lipson, H., Chu, C. C., & Butcher, J. T.
- Venue
- Biofabrication
- Publisher
- IOP Publishing
- Published
- 2012-08-23
- Volume
- 4
- Issue
- 3
- Pages
- 035005
- ISSN
- 1758-5082 (ISSN-L)
- 1758-5090
- OpenAlex
- W2157329190
- Cited by
- 683
- References
- 61
- FWCI
- 17.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.