Functional Behavior of Primary Rat Liver Cells in a Three-Dimensional Perfused Microarray Bioreactor
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
We have previously described the design and operation of a microfabricated bioreactor that supports perfused 3D culture of liver cells and facilitates evolution of tissue-like morphological structures. Here, we describe the functional viability of cells maintained in this microarray bioreactor and examine the influence of different seeding protocols on the evolution of structure and function in comparison with static culture. Primary rat hepatocytes were seeded into the perfusion reactors either as single-cell suspensions immediately after isolation or as spheroidal aggregates formed over a 2- to 3-day period. Initial studies in which cells were cultured for 7 days postisolation revealed significantly greater functional activity and morphological stability of cells that were preaggregated for up to 3 days before seeding in the reactor, compared with direct seeding of single cells. Total albumin secretion and urea genesis rates in single-cell reactor cultures declined significantly during this initial culture period while remaining constant in preaggregated reactor cultures. Longer term studies indicate that rates of albumin secretion and urea genesis are maintained at constant levels through 15 days postisolation. These metabolic rates are an order of magnitude higher than observed for the same preaggregated structures cultured statically with comparable medium ratio and exchange conditions. The metabolic function data are supported by light microscopy images showing viable tissue structures, and electron microscopy images that reveal tight junctions, glycogen storage, and bile canaliculi.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Further, tumor chips faithfully replicate cancer cell gene expression patterns and have the potential to also model complex cytokine and chemokine signaling networks, which may influence immune cell exhaustion and therapeutic resistance (Powers et al., 2002; Holmes et al., 2011; Marushima et al., 2011; Edmondson et al., 2014; Jensen and Teng, 2020).”
From Microphysiological systems as models for immunologically ‘cold’ tumors (2024) · cites this paper as Powers et al., 2002
Citations
Cites
Chapter 4 Preparation of Isolated Rat Liver Cells
Seglen, P. O. (1976) · Methods in Cell Biology · doi:10.1016/s0091-679x(08)61797-5 · Cited by 5,310 · cited 1×
“Hepatocytes were isolated from 150 to 230-g male Fischer rats by a modification of Seglen’s two-step collagenase perfusion procedure 18 as described previously.”
Principles of Tissue Engineering
(2014) · Elsevier eBooks · doi:10.1016/c2011-0-07193-4 · Cited by 1,906
Long‐Term in Vitro Function of Adult Hepatocytes in a Collagen Sandwich Configuration
Dunn, J. C. Y., Tompkins, R. G., & Yarmush, M. L. (1991) · Biotechnology Progress · doi:10.1021/bp00009a007 · Cited by 694
Controlling cell interactions by micropatterning in co-cultures: Hepatocytes and 3T3 fibroblasts
Bhatia, S. N., Yarmush, M. L., & Toner, M. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199702)34:2<189::aid-jbm8>3.0.co;2-m · Cited by 547 · cited 1×
“Heterotypic cell interactions can be fostered by sequential addition of different cell populations onto patterned surfaces 9 or in multilayers.”
Landry, J., Bernier, D., Ouellet, C., Goyette, R., & Marceau, N. (1985) · The Journal of cell biology · doi:10.1083/jcb.101.3.914 · Cited by 520 · cited 2×
“However, parenchymal and nonparenchymal cells present in the initial cell isolation are often observed to reorganize spontaneously into histotypic structures, 11–15 offering a facile route to set up physiological cultures if the reorganization can be appropriately controlled.”
Block, G. D., Locker, J., Bowen, W. C., Petersen, B. E., Katyal, S., Strom, S. C., Riley, T., Howard, T. A., & Michalopoulos, G. K. (1996) · The Journal of cell biology · doi:10.1083/jcb.132.6.1133 · Cited by 491
A microfabricated array bioreactor for perfused 3D liver culture
Powers, M. J., Domansky, K., Kaazempur‐Mofrad, M. R., Kalezi, A., Capitano, A., Upadhyaya, A., Kurzawski, P., Wack, K. E., Stolz, D. B., Kamm, R., et al. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10143 · Cited by 462
Self-citationKoide, N., Sakaguchi, K., Koide, Y., Asano, K., Kawaguchi, M., Matsushima, H., Takenami, T., Shinji, T., Mori, M., & Tsuji, T. (1990) · Experimental Cell Research · doi:10.1016/0014-4827(90)90300-y · Cited by 434
Hepatocyte behavior within three-dimensional porous alginate scaffolds
Glicklis, R., Shapiro, L., Agbaria, R., Merchuk, J. C., & Cohen, S. (2000) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(20000205)67:3<283::aid-bit4>3.0.co;2-h · Cited by 391
Rage, R., Mitchen, J., & Wilding, G. (1990) · Analytical Biochemistry · doi:10.1016/0003-2697(90)90382-j · Cited by 388 · cited 1×
“Cellular DNA content was determined by a protocol based on the methods of Rago et al. 21 Cells were frozen and stored at 2 70°C.”
Research works printed but not linked: 7
- Nyberg S.L., 1994, Ann. Surg., 220, 59
- 10.1002/(SICI)1097-0029(19981201)43:5<379::AID-JEMT4>3.0.CO;2-0 · DOI · Paper page
- 10.1002/(SICI)1097-0290(19960520)50:4<404::AID-BIT7>3.0.CO;2-P · DOI · Paper page
- 10.1002/(SICI)1097-0290(20000205)67:3<344::AID-BIT11>3.0.CO;2-2 · DOI · Paper page
- Remesy C., 1997, Am. J. Physiol., 272, G257
- Takabatake H., 1991, Artif. Organs, 15, 474
- Matthew H.W., 1991, ASAIO Trans., 37, M328
Cited by
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
Capturing complex 3D tissue physiology in vitro
Griffith, L. G., & Swartz, M. A. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1858 · Cited by 2,290
“4 ), and represents one of the first models that integrates 3D microscale tissue with flo”
BackgroundSelf-citationFrom 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
“For example, a microfluidic device containing a cross-flow bioreactor composed of two parallel arrays of silicon and stainless steel microchannels separated by a thin permeable membrane was developed to study the high metabolic demands of cultured primary rat hepatocytes [29,30].”
Background2D and 3D Cell Cultures - a Comparison of Different Types of Cancer Cell Cultures
Kapałczyńska, M., Kolenda, T., Przybyła, W., Zajączkowska, M., Teresiak, A., Filas, V., Ibbs, M., Bliźniak, R., Łuczewski, Ł., & Lamperska, K. (2016) · Archives of Medical Science · doi:10.5114/aoms.2016.63743 · Cited by 1,499
Billiet, T., Gevaert, E., De Schryver, T., Cornelissen, M., & Dubruel, P. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.09.078 · Cited by 1,015
“shear stress responses) are reported applying 3D culture models [23].”
Lee, P. J., Hung, P. J., & Lee, L. P. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21360 · Cited by 509
Interconnected Microphysiological Systems for Quantitative Biology and Pharmacology Studies
Edington, C. D., Chen, W. L. K., Geishecker, E., Kassis, T., Soenksen, L. R., Bhushan, B. M., Freake, D., Kirschner, J., Maass, C., Tsamandouras, N., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-22749-0 · Cited by 487
Self-citationA microfabricated array bioreactor for perfused 3D liver culture
Powers, M. J., Domansky, K., Kaazempur‐Mofrad, M. R., Kalezi, A., Capitano, A., Upadhyaya, A., Kurzawski, P., Wack, K. E., Stolz, D. B., Kamm, R., et al. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10143 · Cited by 462
Self-citationA practical guide to microfluidic perfusion culture of adherent mammalian cells
Kim, L., Toh, Y.-C., Voldman, J., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b704602b · Cited by 455
Reconfigurable microfluidic hanging drop network for multi-tissue interaction and analysis
Frey, O., Misun, P. M., Fluri, D. A., Hengstler, J. G., & Hierlemann, A. (2014) · Nature Communications · doi:10.1038/ncomms5250 · Cited by 387
Emerging Design Principles in Biomaterials and Scaffolds for Tissue Engineering
GRIFFITH, L. G. (2002) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2002.tb03056.x · Cited by 372
Self-citationOrganotypic liver culture models: meeting current challenges in toxicity testing
LeCluyse, E. L., Witek, R. P., Andersen, M. E., & Powers, M. J. (2012) · Critical Reviews in Toxicology · doi:10.3109/10408444.2012.682115 · Cited by 363
“3-D scaffolds with dynamic flow A culture system that combines dynamic flow and 3-D cellular organization in a scalable platform that attempts to mimic the dynamic environment of the acinus was designed by Griffith and colleagues (Powers et al., 2002a; Powers et al., 2002b; Sivaraman et al., 2005; Hwa et al., 2007; Do…”
BackgroundInfluentialSelf-citationCell Culture in 3-Dimensional Microfluidic Structure of PDMS (polydimethylsiloxane)
Leclerc, E., Sakai, Y., & Fujii, T. (2003) · Biomedical Microdevices · doi:10.1023/a:1024583026925 · Cited by 324
Advances in tissue engineering
Langer, R., & Vacanti, J. (2016) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2015.10.022 · Cited by 316
Noninvasive Acoustic Cell Trapping in a Microfluidic Perfusion System for Online Bioassays
Evander, M., Johansson, L., Lilliehorn, T., Piskur, J., Lindvall, M., Johansson, S., Almqvist, M., Laurell, T., & Nilsson, J. (2007) · Analytical Chemistry · doi:10.1021/ac061576v · Cited by 281
Modelling tissues in 3D: the next future of pharmaco-toxicology and food research?
Mazzoleni, G., Di Lorenzo, D., & Steimberg, N. (2009) · Genes & Nutrition · doi:10.1007/s12263-008-0107-0 · Cited by 253
Biofabrication of a three-dimensional liver micro-organ as an in vitro drug metabolism model
Chang, R., Emami, K., Wu, H., & Sun, W. (2010) · Biofabrication · doi:10.1088/1758-5082/2/4/045004 · Cited by 247
Advances in Tissue Engineering
Levenberg, S., & Langer, R. (2004) · Current Topics in Developmental Biology · doi:10.1016/s0070-2153(04)61005-2 · Cited by 223
Nanoliter scale microbioreactor array for quantitative cell biology
Lee, P. J., Hung, P. J., Rao, V. M., & Lee, L. P. (2006) · Biotechnology and Bioengineering · doi:10.1002/bit.20745 · Cited by 212
“…cell culture (Gu et al., 2004), cellular responses to chemical gradients (Li Jeon et al., 2002), investigation of cellular differentiation (Tourovskaia et al., 2005), tissue bioreactors (Leclerc et al., 2004; Powers et al., 2002a), and observation of dynamic gene expression (Thompson et al., 2004).”
BackgroundAssessment of hepatocellular function within PEG hydrogels
Underhill, G. H., Chen, A. A., Albrecht, D. R., & Bhatia, S. N. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.08.043 · Cited by 206
Yoon No, D., Lee, K.-H., Lee, J., & Lee, S.-H. (2015) · Lab on a Chip · doi:10.1039/c5lc00611b · Cited by 205
Direct Cell Writing of 3D Microorgan for In Vitro Pharmacokinetic Model
Chang, R., Nam, J., & Sun, W. (2008) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2007.0392 · Cited by 203
“In vitro cell culture models with human liver cells have already shown great potential in predicting drug toxicity and metabolism in the pharmaceutical industry.(6,7) For example, Powers et al.”
Kulig, K. M., & Vacanti, J. P. (2004) · Transplant Immunology · doi:10.1016/j.trim.2003.12.005 · Cited by 187
Integrated gut/liver microphysiological systems elucidates inflammatory inter‐tissue crosstalk
Chen, W. L. K., Edington, C., Suter, E., Yu, J., Velazquez, J. J., Velazquez, J. G., Shockley, M., Large, E. M., Venkataramanan, R., Hughes, D. J., et al. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26370 · Cited by 172
“…in the present work was designed with consideration of transport and reaction of nutrients and drugs, with experimental measurements of oxygen and distribution of gene therapy vectors and other agents compared to design models as previously described (Domansky et al., 2010; Powers et al., 2002a,b).”
BackgroundMethodSelf-citationMisun, P. M., Rothe, J., Schmid, Y. R. F., Hierlemann, A., & Frey, O. (2016) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.22 · Cited by 167
Microenvironmental regulation of the sinusoidal endothelial cell phenotype in vitro #
March, S., Hui, E. E., Underhill, G. H., Khetani, S., & Bhatia, S. N. (2009) · Hepatology · doi:10.1002/hep.23085 · Cited by 164
“For example, a small population of SE-1 positive cells was observed over 13 days in a 3D perfused co-culture of hepatocytes and LSECs (13) where the hepatocytes in the 3D perfused environment are more phenotypically stable than in monolayer culture (25).”
Liver tissue engineering in the evaluation of drug safety
Dash, A., Inman, W., Hoffmaster, K., Sevidal, S., Kelly, J., Obach, R. S., Griffith, L. G., & Tannenbaum, S. R. (2009) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1517/17425250903160664 · Cited by 158
“These are being combined with advances in microfluidics to create integrated devices that can be translated into pharmaceuticals labs [34,115,117,119,154,176,177].”
BackgroundInfluentialSelf-citationIn vitro platforms for evaluating liver toxicity
Bale, S. S., Vernetti, L., Senutovitch, N., Jindal, R., Hegde, M., Gough, A., McCarty, W. J., Bakan, A., Bhushan, A., Shun, T. Y., et al. (2014) · Experimental Biology and Medicine · doi:10.1177/1535370214531872 · Cited by 155
Chung, S., Sudo, R., Vickerman, V., Zervantonakis, I. K., & Kamm, R. D. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-9899-3 · Cited by 154
How multi-organ microdevices can help foster drug development
Esch, M. B., Smith, A. S. T., Prot, J.-M., Oleaga, C., Hickman, J. J., & Shuler, M. L. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.12.003 · Cited by 153
3D in vitro models of liver fibrosis
van Grunsven, L. A. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.07.004 · Cited by 177
Ferrell, N., Desai, R. R., Fleischman, A. J., Roy, S., Humes, H. D., & Fissell, W. H. (2010) · Biotechnology and Bioengineering · doi:10.1002/bit.22835 · Cited by 145
“…have been used to study a variety of adherent cell lines for high-throughput cell assays (Hung et al., 2005; Lee et al., 2006), drug and toxin screening (Park and Shuler, 2003; Wang et al., 2007), and tissue engineering (Bettinger et al., 2006; Borenstein et al., 2002; Powers et al., 2002a,b).”
Integration of Technologies for Hepatic Tissue Engineering
Nahmias, Y., Berthiaume, F., & Yarmush, M. L. (2006) · Springer eBooks · doi:10.1007/10_029 · Cited by 165
Leclerc, É., Furukawa, K. S., Miyata, F., Sakai, Y., Ushida, T., & Fujii, T. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.060 · Cited by 142
3D culture of adult mouse neural stem cells within functionalized self-assembling peptide scaffolds
Cunha, Villa, Silva, Gelain, & Panseri, S. (2011) · International Journal of Nanomedicine · doi:10.2147/ijn.s17292 · Cited by 141
Thomas, R. J., Bhandari, R., Barrett, D. A., Bennett, A. J., Fry, J. R., Powe, D., Thomson, B. J., & Shakesheff, K. M. (2005) · Cells Tissues Organs · doi:10.1159/000091096 · Cited by 138
“…particularly successful in the preservation of membrane polarity and cell structure, as well as maintenance of functional attributes and suppression of markers of dedifferentiation such as -fetoprotein [Powers et al., 2002, Hanada et al., 2003; Kudryavtseva and Engelhardt, 2003; Engl et al., 2004].”
BackgroundBioreactor technologies to support liver function in vitro
Ebrahimkhani, M. R., Neiman, J. A. S., Raredon, M. S. B., Hughes, D. J., & Griffith, L. G. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.02.011 · Cited by 135
“microperfusion as evidenced by 2-photon observance of expression of EGFP following adenoviral gene delivery [139][138].”
Self-citationGoral, V. N., Hsieh, Y.-C., Petzold, O. N., Clark, J. S., Yuen, P. K., & Faris, R. A. (2010) · Lab on a Chip · doi:10.1039/c0lc00135j · Cited by 130
A Novel Perfusion Bioreactor Providing a Homogenous Milieu for Tissue Regeneration
Dvir, T., Benishti, N., Shachar, M., & Cohen, S. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.2843 · Cited by 127
3D spherical microtissues and microfluidic technology for multi-tissue experiments and analysis
Kim, J.-Y., Fluri, D. A., Marchan, R., Boonen, K., Mohanty, S., Singh, P., Hammad, S., Landuyt, B., Hengstler, J. G., Kelm, J. M., et al. (2015) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2015.01.003 · Cited by 126
Challenges and Opportunities in the Design of Liver-on-Chip Microdevices
Ehrlich, A., Duche, D., Ouedraogo, G., & Nahmias, Y. (2019) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-060418-052305 · Cited by 125
Membrane-Based PDMS Microbioreactor for Perfused 3D Primary Rat Hepatocyte Cultures
Ostrovidov, S., Jiang, J., Sakai, Y., & Fujii, T. (2004) · Biomedical Microdevices · doi:10.1023/b:bmmd.0000048560.96140.ca · Cited by 145
Fraczek, J., Bolleyn, J., Vanhaecke, T., Rogiers, V., & Vinken, M. (2013) · Archives of Toxicology · doi:10.1007/s00204-012-0983-3 · Cited by 119
Human hepatocyte functions in a crossed hollow fiber membrane bioreactor
Bartolo, L. D., Salerno, S., Curcio, E., Piscioneri, A., Rende, M., Morelli, S., Tasselli, F., Bader, A., & Drioli, E. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.01.011 · Cited by 119
Trends in the development of microfluidic cell biochips for in vitro hepatotoxicity
Baudoin, R., Corlu, A., Griscom, L., Legallais, C., & Leclerc, É. (2006) · Toxicology in Vitro · doi:10.1016/j.tiv.2006.11.004 · Cited by 119
Materne, E.-M., Tonevitsky, A. G., & Marx, U. (2013) · Lab on a Chip · doi:10.1039/c3lc50240f · Cited by 112
Behavior of HepG2/C3A cell cultures in a microfluidic bioreactor
Baudoin, R., Griscom, L., Prot, J. M., Legallais, C., & Leclerc, É. (2010) · Biochemical Engineering Journal · doi:10.1016/j.bej.2010.10.007 · Cited by 111
Hwa, A. J., Fry, R. C., Sivaraman, A., So, P. T., Samson, L. D., Stolz, D. B., & Griffith, L. G. (2007) · The FASEB Journal · doi:10.1096/fj.06-7473com · Cited by 110
Self-citationHemodynamic flow improves rat hepatocyte morphology, function, and metabolic activity in vitro
Dash, A., Simmers, M. B., Deering, T. G., Berry, D. J., Feaver, R. E., Hastings, N. E., Pruett, T. L., LeCluyse, E. L., Blackman, B. R., & Wamhoff, B. R. (2013) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00331.2012 · Cited by 108
“Various groups have begun to incorporate fluid movement (8, 12, 35, 36) and perfusion to overcome these issues as well as to ensure adequate oxygenation to three-dimensional tissue structures.”
BackgroundImprovement of HepG2/C3a cell functions in a microfluidic biochip
Prot, J. M., Aninat, C., Griscom, L., Razan, F., Brochot, C., Guillouzo, C. G., Legallais, C., Corlu, A., & Leclerc, E. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23104 · Cited by 102
“…advanced works progress toward the reconstruction of bioartificial microliver in vitro, so called ‘‘liver on chip’’ (Borenstein et al., 2002; Chao et al., 2009; Domansky et al., 2010; Leclerc et al., 2003, 2004; Park et al., 2005; Powers et al., 2001, 2002; Toh et al., 2009; Zhang et al., 2008).”
BackgroundSchneeberger, K., Spee, B., Costa, P., Sachs, N., Clevers, H., & Malda, J. (2017) · Biofabrication · doi:10.1088/1758-5090/aa6121 · Cited by 100
Metabolomics-on-a-Chip and Predictive Systems Toxicology in Microfluidic Bioartificial Organs
Shintu, L., Baudoin, R., Navratil, V., Prot, J.-M., Pontoizeau, C., Defernez, M., Blaise, B. J., Domange, C., Péry, A. R., Toulhoat, P., et al. (2012) · Analytical Chemistry · doi:10.1021/ac2011075 · Cited by 100
Cell Encapsulation in Sub-mm Sized Gel Modules Using Replica Molding
McGuigan, A. P., Bruzewicz, D. A., Glavan, A. C., Butte, M. J., & Whitesides, G. M. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002258 · Cited by 111
“biopolymers or other matrixes to form an ‘‘engineered tissue’’ [12–15].”
Three-Dimensional Tissue Models for Drug Discovery and Toxicology
Pampaloni, F., Stelzer, E., & Masotti, A. (2009) · Recent Patents on Biotechnology · doi:10.2174/187220809788700201 · Cited by 99
Choucha Snouber, L., Bunescu, A., Naudot, M., Legallais, C., Brochot, C., Dumas, M. E., Elena-Herrmann, B., & Leclerc, E. (2013) · Toxicological Sciences · doi:10.1093/toxsci/kfs230 · Cited by 98
A low shear stress modular bioreactor for connected cell culture under high flow rates
Mazzei, D., Guzzardi, M. A., Giusti, S., & Ahluwalia, A. (2010) · Biotechnology and Bioengineering · doi:10.1002/bit.22671 · Cited by 97
“Several reports describe the effects of flow and shear stress on hepatocyte cultures (Mufti and Shuler, 1995; Nakatsuka et al., 2006; Powers et al., 2002b; Tanaka et al., 2006).”
BackgroundResultTechnique for the control of spheroid diameter using microfabricated chips
Sakai, Y., & Nakazawa, K. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.06.004 · Cited by 94
Foglietta, F., Canaparo, R., Muccioli, G., Terreno, E., & Serpe, L. (2020) · Life Sciences · doi:10.1016/j.lfs.2020.117784 · Cited by 105
“Recently, thanks to the use of a perfused bioreactor of liver cells cultured in 3D models, the metabolic functions and the secretions of specific liver factors (like albumin, glycogen and urea) were detected over time, demonstrating an optimal organization of liver structures in 3D models [9].”
BackgroundSarkar, U., Rivera‐Burgos, D., Large, E. M., Hughes, D. J., Ravindra, K. C., Dyer, R. L., Ebrahimkhani, M. R., Wishnok, J. S., Griffith, L. G., & Tannenbaum, S. R. (2015) · Drug Metabolism and Disposition · doi:10.1124/dmd.115.063495 · Cited by 101
“ABBREVIATIONS: ACN, acetonitrile; AUC, area under the curve; CAS, chemical abstract service; CL, clearance; CLh, predicted hepatic clearance; CLint, intrinsic clearance; CLint-in vivo, in vivo intrinsic clearance; 3D, three-dimensional; FA, formic acid; HC, hydrocortisone; HSA, human serum albumin; IL6, interleukin 6;…”
BackgroundSelf-citationTostões, R. M., Leite, S. B., Miranda, J. P., Sousa, M., Wang, D. I. C., Carrondo, M. J. T., & Alves, P. M. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.22920 · Cited by 86
“Perfused microbioreactors with increased throughput capability for hepatocyte culture have recently been developed (Carraro et al., 2008; Korin et al., 2009; Park et al., 2008; Powers et al., 2002; Sivaraman et al., 2005; Zhang et al., 2008).”
BackgroundUsta, O. B., McCarty, W. J., Bale, S., Hegde, M., Jindal, R., Bhushan, A., Golberg, I., & Yarmush, M. L. (2015) · TECHNOLOGY · doi:10.1142/s2339547815300012 · Cited by 85
Ma, L., Barker, J., Zhou, C., Li, W., Zhang, J., Lin, B., Foltz, G., Küblbeck, J., & Honkakoski, P. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.02.054 · Cited by 83
Yates, C. C., Shepard, C. R., Papworth, G. D., Dash, A., Stolz, D. B., Tannenbaum, S. R., Griffith, L. G., & Wells, A. H. (2007) · Advances in cancer research · doi:10.1016/s0065-230x(06)97010-9 · Cited by 87
Self-citationNeiman, J. A. S., Raman, R., Chan, V., Rhoads, M. G., Raredon, M. S. B., Velazquez, J. J., Dyer, R. L., Bashir, R., Hammond, P. T., & Griffith, L. G. (2015) · Biotechnology and Bioengineering · doi:10.1002/bit.25494 · Cited by 78
“However, because hepatocytes are highly metabolically active – typically residing in close contact with blood through the fenestrated endothelium – controlling mass transfer of nutrients, substrates, and metabolites in 3D aggregates in static culture is challenging [Powers et al., 2002a].”
BackgroundMethodResultInfluentialSelf-citationConsidering new methodologies in strategies for safety assessment of foods and food ingredients
Blaauboer, B. J., Boobis, A. R., Bradford, B., Cockburn, A., Constable, A., Daneshian, M., Edwards, G., Garthoff, J. A., Jeffery, B., Krul, C. A. M., et al. (2016) · Food and Chemical Toxicology · doi:10.1016/j.fct.2016.02.019 · Cited by 91
“Microarray bioreactors involving spheroids with integrated fluid flow could already show to be able to mimic the liver blood flow dynamics (Powers et al., 2002).”
BackgroundIn vitro microscale systems for systematic drug toxicity study
Sung, J. H., & Shuler, M. L. (2009) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-009-0369-y · Cited by 82
“Preaggregation of cells into spheroid-like form prior to seeding into the device further improved the liver-specific cell behavior, such as albumin secretion and urea synthesis [ 91 ].”
BackgroundPerfusion culture of fetal human hepatocytes in microfluidic environments
Leclerc, É., Sakai, Y., & Fujii, T. (2004) · Biochemical Engineering Journal · doi:10.1016/j.bej.2003.09.010 · Cited by 73
Prot, J.-M., Bunescu, A., Elena-Herrmann, B., Aninat, C., Snouber, L. C., Griscom, L., Razan, F., Bois, F. Y., Legallais, C., Brochot, C., et al. (2012) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2011.12.017 · Cited by 71
“…organs can now take advantage of recent developments in microtechnology to produce systems on a very small scale (Griffith and Naughton 2002; Powers et al., 2002; Sivaraman et al., 2005; Chao et al., 2010; Prot et al., 2011a; Baudoin et al., 2007; Novik et al., 2010; Baudoin et al., 2011).”
BackgroundBioprinting for Liver Transplantation
Kryou, C., Leva, C. V., Chatzipetrou, M., & Zergioti, I. (2019) · Bioengineering · doi:10.3390/bioengineering6040095 · Cited by 78
“Conventional liver tissue models have recently been used to fabricate in vitro 3D liver tissue models [17].”
Method3D tissue engineering, an emerging technique for pharmaceutical research
Jensen, G., Morrill, C. C., & Huang, Y. (2018) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2018.03.006 · Cited by 82
Deconstructing Signaling in Three Dimensions
Rubashkin, M. G., Ou, G., & Weaver, V. M. (2014) · Biochemistry · doi:10.1021/bi401710d · Cited by 68
Trapping of Bioparticles via Microvortices in a Microfluidic Device for Bioassay Applications
Lin, C. M., Lai, Y. S., Liu, H. P., Chen, C. Y., & Wo, A. M. (2008) · Analytical Chemistry · doi:10.1021/ac800972t · Cited by 66
Laminar-flow immediate-overlay hepatocyte sandwich perfusion system for drug hepatotoxicity testing
Xia, L., Ng, S., Han, R., Tuo, X., Xiao, G., Leo, H. L., Cheng, T., & Yu, H. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.07.022 · Cited by 67
Vivares, A., Salle-Lefort, S., Arabeyre-Fabre, C., Ngo, R., Penarier, G., Bremond, M., Moliner, P., Gallas, J.-F., Fabre, G., & Klieber, S. (2015) · Xenobiotica · doi:10.3109/00498254.2014.944612 · Cited by 65
“Viability of cultured human hepatocytes was evaluated over time by immunohistochemistry and electron microscopy as well as through studying the common morphological and functional features of human hepatocytes in the device, as previously demonstrated in rat liver cells by Powers et al. (2002).”
MethodNishikawa, M., Yamamoto, T., Kojima, N., Komori, K., Fujii, T., & Sakai, Y. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21690 · Cited by 66
“In relation to 3D aggregates (Powers et al., 2002b; Seo et al., 2005), Chua et al.”
BackgroundMethodNirmalanandhan, V. S., & Sittampalam, G. S. (2009) · SLAS Discovery · doi:10.1177/1087057109336591 · Cited by 65
Integration of in silico and in vitro platforms for pharmacokinetic–pharmacodynamic modeling
Sung, J. H., Esch, M. B., & Shuler, M. L. (2010) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1517/17425255.2010.496251 · Cited by 64
“Interestingly, pre-aggregation of cells into a spheroid-like form prior to seeding into the device improved the liver-specific cell behavior, such as albumin secretion and urea synthesis [70].”
BackgroundTwo-dimensional microarray of HepG2 spheroids using collagen/polyethylene glycol micropatterned chip
Tamura, T., Sakai, Y., & Nakazawa, K. (2007) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-007-3305-1 · Cited by 71
Reconstruction of 3D stacked‐up structures by rat small hepatocytes on microporous membranes
Sudo, R., Mitaka, T., Ikeda, M., & Tanishita, K. (2005) · The FASEB Journal · doi:10.1096/fj.04-3269fje · Cited by 62
“Another method for 3D culture uses scaffolds, such as paper (14), poly-L-lactic-acid scaffolds (15, 16), or 3D-perfused microarray bioreactors (17).”
MethodWhat is regenerative medicine? Emergence of applied stem cell and developmental biology
Mironov, V. A., Visconti, R., & Markwald, R. W. (2004) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.4.6.773 · Cited by 77
“The 3D human perfused tissue engineered constructs suitable for studying circulating stem and progenitor cell recruitment are only at the earliest initial stages of development [7,8].”
Background3D bioprinting for organ and organoid models and disease modeling
Juraski, A. D. C., Sharma, S., Sparanese, S., da Silva, V. A., Wong, J., Laksman, Z., Flannigan, R. K., Rohani, L., & Willerth, S. M. (2023) · Expert Opinion on Drug Discovery · doi:10.1080/17460441.2023.2234280 · Cited by 72
Metabolic Characterization of Primary Rat Hepatocytes Cultivated in Parallel Microfluidic Biochips
Legendre, A., Baudoin, R., Alberto, G., Paullier, P., Naudot, M., Bricks, T., Brocheton, J., Jacques, S., Cotton, J., & Leclerc, É. (2013) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23466 · Cited by 64
3D Cultivation Techniques for Primary Human Hepatocytes
Bachmann, A., Moll, M., Gottwald, E., Nies, C., Zantl, R., Wagner, H., Burkhardt, B., Sánchez, J., Ladurner, R., Thasler, W., et al. (2015) · Microarrays · doi:10.3390/microarrays4010064 · Cited by 59
“The viability of hepatocyte cultures under high shear is lower than for cultures under 2D conditions [62,63].”
BackgroundFunctionalized self‐assembling peptide hydrogel enhance maintenance of hepatocyte activity in vitro
Genové, E., Schmitmeier, S., Sala, A., Borrós, S., Bader, A., Griffith, L. G., & Semino, C. E. (2009) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2009.00970.x · Cited by 59
“Most recently there has been an approach towards the use of synthetic biomaterials such as hydrogels, porous membranes or the potential utility of perfused bioreactors to assess these goals [13–17].”
BackgroundSelf-citationA Review of State-of-the-Art on Enabling Additive Manufacturing Processes for Precision Medicine
Awad, A., Goyanes, Á., Basit, A. W., Zidan, A. S., Xu, C., Li, W., Narayan, R. J., & Chen, R. K. (2022) · Journal of Manufacturing Science and Engineering · doi:10.1115/1.4056199 · Cited by 63
Microfluidic Patterning of Cellular Biopolymer Matrices for Biomimetic 3-D Structures
Tan, W., & Desai, T. A. (2003) · Biomedical Microdevices · doi:10.1023/a:1025764310391 · Cited by 56
Li, W., Li, P., Li, N., Du, Y., Lü, S., Elad, D., & Long, M. (2021) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.00379.2019 · Cited by 53
Hepatocyte spheroid culture on a polydimethylsiloxane chip having microcavities
Nakazawa, K., Izumi, Y., Fukuda, J., & Yasuda, T. (2006) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856206777996853 · Cited by 52
Knowles, D. W., Sudar, D., Bator-Kelly, C. M., Bissell, M. J., & Lelièvre, S. A. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0509944102 · Cited by 51
Freyer, N., Knöspel, F., Strahl, N., Amini, L., Schrade, P., Bachmann, S., Damm, G., Seehofer, D., Jacobs, F., Monshouwer, M., et al. (2016) · BioResearch Open Access · doi:10.1089/biores.2016.0027 · Cited by 50
Peck, Y., & Wang, D. (2013) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2013.751096 · Cited by 52
“These include a perfusion bioreactor incorporated with a novel flow-distributing mesh for higher cell seeding efficiency and even cell distribution throughout the macroporous alginate scaffolds [107], rotating-wall vessel bioreactors that provide continuous flow of culture medium in a simulated microgravity environmen…”
MethodMicropatterned organoid culture of rat hepatocytes and HepG2 cells
Mori, R., Sakai, Y., & Nakazawa, K. (2008) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.106.237 · Cited by 52
Choudhury, D., Mo, X., Iliescu, C., Tan, L. L., Tong, W. H., & Yu, H. (2011) · Biomicrofluidics · doi:10.1063/1.3593407 · Cited by 45
Baudoin, R., Prot, J. M., Nicolas, G., Brocheton, J., Brochot, C., Legallais, C., Benech, H., & Leclerc, E. (2013) · Xenobiotica · doi:10.3109/00498254.2012.706725 · Cited by 45
“…have been made to propose liver microfluidic biochips as a means of investigating drug and xenobiotic metabolisms or hepatotoxicity (Griffith & Naughton 2002; Powers et al. 2002; Sivaraman et al. 2005; Chao et al. 2009; Prot et al. 2011a; Novik et al. 2010; Baudoin et al. 2011, Zhang et al. 2011).”
BackgroundLee, M., Teng, S., Chen, H., Lo, W., Sun, Y., Lin, T.-Y., Chiou, L., Jiang, C., & Dong, C. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.2835 · Cited by 43
In vitro liver model using microfabricated scaffolds in a modular bioreactor
Vinci, B., Cavallone, D., Vozzi, G., Mazzei, D., Domenici, C., Brunetto, M., & Ahluwalia, A. (2010) · Biotechnology Journal · doi:10.1002/biot.200900074 · Cited by 41
3D-bioprinted all-inclusive bioanalytical platforms for cell studies
Mazrouei, R., Velasco, V., & Esfandyarpour, R. (2020) · Scientific Reports · doi:10.1038/s41598-020-71452-6 · Cited by 42
Methods for Predicting Human Drug Metabolism
Jolivette, L. J., & Ekins, S. (2006) · Advances in clinical chemistry · doi:10.1016/s0065-2423(06)43005-5 · Cited by 42
Harada, K., Mitaka, T., Miyamoto, S., Sugimoto, S., Ikeda, S., Takeda, H., Mochizuki, Y., & Hirata, K. (2003) · Journal of Hepatology · doi:10.1016/s0168-8278(03)00412-4 · Cited by 45
Sistare, F. D., Mattes, W. B., & LeCluyse, E. L. (2016) · ILAR Journal · doi:10.1093/ilar/ilw025 · Cited by 40
Metadata
- Authors
- Powers, M. J., Janigian, D. M., Wack, K. E., Baker, C. S., Stolz, D. B., & Griffith, L. G.
- Affiliations
- Massachusetts Institute of Technology (US)
- Genetics Institute, North Andover, Massachusetts
- University of Pittsburgh (US)
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2002-07
- Volume
- 8
- Issue
- 3
- Pages
- 499-513
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W1970857673
- Cited by
- 234
- References
- 46
- Citations by year
- 2025: 2 · 2024: 2 · 2023: 4 · 2022: 2 · 2021: 3 · 2020: 8 · 2019: 8 · 2018: 6 · 2017: 7 · 2016: 8 · 2015: 10 · 2014: 12 · 2013: 14 · 2012: 16
- FWCI
- 8.33
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.liebertpub.com/nv/resources-tools/text-and-data-mining-policy/121/ (tdm)
- Locations
- Tissue Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- Defense Advanced Research Projects Agency
- National Cancer Institute (CA 76541)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Health Sciences › Medicine › Hepatology › Liver physiology and pathology
- Keywords
- primary hepatocytes, 3D cell culture, hepatocyte spheroids, albumin secretion, urea synthesis, tight junctions, bile canaliculi, glycogen storage, rat liver
- MeSH terms
- Albumins, Animals, Cells, Cultured, DNA, Microscopy, Electron, Time Factors, Urea, Spheroids, Cellular, Bioreactors, Hepatocytes, Tissue Engineering, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.