The Effect of Temperature and Oligonucleotide Primer Length on the Specificity and Efficiency of Amplification by the Polymerase Chain Reaction
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
The polymerase chain reaction (PCR) is most effectively performed using a thermostable DNA polymerase such as that isolated from Thermus aquaticus. Since temperature and oligonucleotide length are known to control the specificity of oligonucleotide hybridization, we have investigated the effect of oligonucleotide length, base composition, and the annealing temperature on the specificity and efficiency of amplification by the PCR. Generally, the specificity of PCR is controlled by the length of the oligonucleotide and/or the temperature of annealing of the primer to the template. An empirical relationship between oligonucleotide length and ability to support amplification was determined. This relationship allows for the design of specific oligonucleotide primers. A model is proposed which helps explain the observed dependence of PCR on annealing temperature and length of the primer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Primer-Directed Enzymatic Amplification of DNA with a Thermostable DNA Polymerase
Saiki, R. K., Gelfand, D. H., Stoffel, S., Scharf, S. J., Higuchi, R., Horn, G. T., Mullis, K. B., & Erlich, H. A. (1988) · Science · doi:10.1126/science.2448875 · Cited by 17,719
Saiki, R. K., Scharf, S., Faloona, F., Mullis, K. B., Horn, G. T., Erlich, H. A., & Arnheim, N. (1985) · Science · doi:10.1126/science.2999980 · Cited by 8,956
Hypervariable ‘minisatellite’ regions in human DNA
Jeffreys, A. J., Wilson, V., & Thein, S. L. (1985) · Nature · doi:10.1038/314067a0 · Cited by 3,741
Specific Enzymatic Amplification of DNA In Vitro: The Polymerase Chain Reaction
Mullis, K., Faloona, F., Scharf, S., Saiki, R., Horn, G., & Erlich, H. (1986) · Cold Spring Harbor Symposia on Quantitative Biology · doi:10.1101/sqb.1986.051.01.032 · Cited by 3,558
Gyllensten, U. B., & Erlich, H. A. (1988) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.85.20.7652 · Cited by 1,560 · cited 1×
“PCR has been used for the amplification of target DNA templates for subsequent DNA sequencing (Gyllensten and Erlich, 1988) as well as combined with a ligation based analysis of single nucleotide variation (Landegren et ai, 1988; Wu and Wallace, 1989).”
Complete nucleotide sequences of the T24 human bladder carcinoma oncogene and its normal homologue
Capon, D. J., Chen, E. Y., Levinson, A. D., Seeburg, P. H., & Goeddel, D. V. (1983) · Nature · doi:10.1038/302033a0 · Cited by 997
Polymorphic DNA region adjacent to the 5' end of the human insulin gene.
Bell, G. I., Karam, J. H., & Rutter, W. J. (1981) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.78.9.5759 · Cited by 889
A Ligase-Mediated Gene Detection Technique
Landegren, U., Kaiser, R., Sanders, J., & Hood, L. (1988) · Science · doi:10.1126/science.3413476 · Cited by 828
Direct Cloning and Sequence Analysis of Enzymatically Amplified Genomic Sequences
Scharf, S. J., Horn, G. T., & Erlich, H. A. (1986) · Science · doi:10.1126/science.3461561 · Cited by 752
Wallace, R. B., Shaffer, J., Murphy, R. F., Bonner, J., Hirose, T., & Itakura, K. (1979) · Nucleic Acids Research · doi:10.1093/nar/6.11.3543 · Cited by 748
Self-citation
Research works printed but not linked: 3
- 10.1002/bip.1981.360200514 · doi:10.1002/bip.1981.360200514
- 10.1016/0076-6879(87)54072-1 · doi:10.1016/0076-6879(87)54072-1
- 10.1126/science.239.4839.487 · DOI · Paper page
Cited by
Bustin, S. (2000) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0250169 · Cited by 3,872
Real-Time PCR for mRNA Quantitation
Wong, M. L., & Medrano, J. F. (2005) · BioTechniques · doi:10.2144/05391rv01 · Cited by 1,786
Jaque, D., & Vetrone, F. (2012) · Nanoscale · doi:10.1039/c2nr30764b · Cited by 1,507
Multiplex PCR: Optimization and Application in Diagnostic Virology
Elnifro, E. M., Ashshi, A. M., Cooper, R. J., & Klapper, P. E. (2000) · Clinical Microbiology Reviews · doi:10.1128/cmr.13.4.559 · Cited by 961
A PCR primer bank for quantitative gene expression analysis
Wang, X. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng154 · Cited by 859
Effective amplification of long targets from cloned inserts and human genomic DNA.
Cheng, S., Fockler, C., Barnes, W. M., & Higuchi, R. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.12.5695 · Cited by 626
General concepts for PCR primer design.
Dieffenbach, C. W., Lowe, T. M., & Dveksler, G. S. (1993) · Genome Research · doi:10.1101/gr.3.3.s30 · Cited by 484
Vestheim, H., & Jarman, S. N. (2008) · Frontiers in Zoology · doi:10.1186/1742-9994-5-12 · Cited by 481
PCR Biases Distort Bacterial and Archaeal Community Structure in Pyrosequencing Datasets
Pinto, A. J., & Raskin, L. (2012) · PLoS ONE · doi:10.1371/journal.pone.0043093 · Cited by 443
Multiplex PCR: Optimization and Application in Diagnostic Virology
Elnifro, E. M., Ashshi, A. M., Cooper, R. J., & Klapper, P. E. (2000) · Clinical Microbiology Reviews · doi:10.1128/cmr.13.4.559-570.2000 · Cited by 964
Malecaze, F. (1994) · Archives of Ophthalmology · doi:10.1001/archopht.1994.01090230090028 · Cited by 364
Validation of a quantitative method for real time PCR kinetics
Liu, W., & Saint, D. A. (2002) · Biochemical and Biophysical Research Communications · doi:10.1016/s0006-291x(02)00478-3 · Cited by 359
Terahertz Wave Accelerates DNA Unwinding: A Molecular Dynamics Simulation Study
Wu, K., Qi, C., Zhu, Z., Wang, C., Song, B., & Chang, C. (2020) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.0c01850 · Cited by 305
Chun, J.-Y., Kim, K.-J., Hwang, I.-T., Kim, Y.-J., Lee, D.-H., Lee, I.-K., & Kim, J.-K. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm051 · Cited by 208
“In general, primers425 bases are rarely used, since the Tms of 25 mers or the longer primers can be over 708C, which is too high for proper annealing (15).”
BackgroundKaarj, K., Akarapipad, P., & Yoon, J.-Y. (2018) · Scientific Reports · doi:10.1038/s41598-018-30797-9 · Cited by 184
Modlin, I. M., Drozdov, I., & Kidd, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0063364 · Cited by 164
“A consistent protocol for RNA isolation, cDNA synthesis and real-time PCR is considered appropriate to provide a stable platform for target and housekeeping gene analyses [57,62,63,66,67].”
Metadata
- Authors
- WU, D. Y., UGOZZOLI, L., PAL, B. K., QIAN, J., & WALLACE, R. B.
- Venue
- DNA and Cell Biology
- Publisher
- SAGE Publications
- Published
- 1991-04
- Volume
- 10
- Issue
- 3
- Pages
- 233-238
- ISSN
- 1044-5498 (ISSN-L)
- 1557-7430
- OpenAlex
- W2109167494
- Cited by
- 192
- References
- 26
- FWCI
- 2.28
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.liebertpub.com/nv/resources-tools/text-and-data-mining-policy/121/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.