A review and update on the current status of retinal prostheses (bionic eye)
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
INTRODUCTION/BACKGROUND: The Argus® II is the first retinal prosthesis approved for the treatment of patients blind from retinitis pigmentosa (RP), receiving CE (Conformité Européenne) marking in March 2011 and FDA approval in February 2013. Alpha-IMS followed closely and obtained CE marking in July 2013. Other devices are being developed, some of which are currently in clinical trials. SOURCES OF DATA: A systematic literature search was conducted on PubMED, Google Scholar and IEEExplore. AREAS OF AGREEMENT: Retinal prostheses play a part in restoring vision in blind RP patients providing stable, safe and long-term retinal stimulation. AREAS OF CONTROVERSY: Objective improvement in visual function does not always translate into consistent improvement in the patient's quality of life. Controversy exists over the use of an external image-capturing device versus internally placed photodiode devices. GROWING POINTS: The alpha-IMS, a photovoltaic-based retinal prosthesis recently obtained its CE marking in July 2013. AREAS TIMELY FOR DEVELOPING RESEARCH: Improvement in retinal prosthetic vision depends on: (i) improving visual resolution, (ii) improving the visual field, (iii) developing an accurate neural code for image processing and (iv) improving the biocompatibility of the device to ensure longevity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819 · cited 5×
“The alpha-IMS subretinal implant consists of 1500 MPDA elements, each coupled to a square microelectrode of 50 μm × 50 μm (2500 μm(2)).(19) Stimulation of one electrode 35 Retinal prostheses: a review, 2014, Vol.”
BackgroundMethodInfluentialInterim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700
Electrical stimulation of neural tissue to evoke behavioral responses
Tehovnik, E. J. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00131-x · Cited by 478
da Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359 · cited 1×
“Four subjects were able to consistently read unrehearsed short words of up to four letters.(43) The best grating visual acuity is logMAR 1.”
BackgroundAhuja, A. K., Dorn, J. D., Caspi, A., McMahon, M. J., Dagnelie, G., daCruz, L., Stanga, P., Humayun, M. S., Greenberg, R. J., & Argus II Study Group (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.179622 · Cited by 289 · cited 1×
“Although this may initially be an issue, there is evidence that Argus II subjects showed functional improvement in orientation and mobility,(18) as well as their ability to localize squares by pointing on the LCD flat screen, with the use of the device.(41) Conversely, the use of an external image capture and processi…”
BackgroundVisual acuity impairment in patients with retinitis pigmentosa at age 45 years or older
Grover, S., Fishman, G. A., Anderson, R. J., Tozatti, M. S. V., Heckenlively, J. R., Weleber, R. G., Edwards, A. O., & Brown, J. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)90342-1 · Cited by 235
Retinal prosthetic strategy with the capacity to restore normal vision
Nirenberg, S., & Pandarinath, C. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1207035109 · Cited by 207
Brummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205
Dorn, J. D., Ahuja, A. K., Caspi, A., da Cruz, L., Dagnelie, G., Sahel, J.-A., Greenberg, R. J., McMahon, M. J., & Argus II Study Group, F. T. (2013) · JAMA Ophthalmology · doi:10.1001/2013.jamaophthalmol.221 · Cited by 177
Wilke, R., Gabel, V.-P., Sachs, H., Bartz Schmidt, K.-U., Gekeler, F., Besch, D., Szurman, P., Stett, A., Wilhelm, B., Peters, T., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6946 · Cited by 155 · cited 1×
“gov NCT00515814).(44) It consisted of a 16 electrode array for direct electrical stimulation of the retina, as well as the light-sensitive photovoltaic MPDA.”
MethodToward the development of a cortically based visual neuroprosthesis
Normann, R. A., Greger, B. A., House, P., Romero, S. F., Pelayo, F., & Fernandez, E. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/035001 · Cited by 143 · cited 1×
“These alternative approaches may be necessary in cases whereby the entire retina has been destroyed due to the disease nature, and include stimulation of the optic nerve head,1–3 the lateral geniculate nucleus(4) and the primary visual cortex.(5,6) The visual pathway functions as a complex image processor as well as a…”
BackgroundTemporal properties of visual perception on electrical stimulation of the retina
Pérez Fornos, A., Sommerhalder, J., da Cruz, L., Sahel, J. A., Mohand-Said, S., Hafezi, F., & Pelizzone, M. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-9344 · Cited by 113
Panetsos, F., Sanchez-Jimenez, A., Cerio, E. D.-D., Diaz-Guemes, I., & Sanchez, F. M. (2011) · Frontiers in Neuroscience · doi:10.3389/fnins.2011.00084 · Cited by 65
Cited by
Organic Bioelectronics: Bridging the Signaling Gap between Biology and Technology
Simon, D. T., Gabrielsson, E. O., Tybrandt, K., & Berggren, M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00146 · Cited by 568
Subretinal visual implant alpha IMS - clinical trial interim report
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Chee, C. K., Cottriall, C. L., Gekeler, F., Groppe, M., Jackson, T. L., MacLaren, R. E., Koitschev, A., et al. (2015) · Vision Research · doi:10.1016/j.visres.2015.03.001 · Cited by 387
Bhowmick, A., & Hazarika, S. M. (2017) · Journal on Multimodal User Interfaces · doi:10.1007/s12193-016-0235-6 · Cited by 271
Bioengineering strategies for restoring vision
Cehajic-Kapetanovic, J., Singh, M. S., Zrenner, E., & MacLaren, R. E. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00836-4 · Cited by 79
Li, H., Su, X., Wang, J., Kan, H., Han, T., Zeng, Y., & Chai, X. (2018) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2017.11.001 · Cited by 59
Metadata
- Authors
- Luo, Y. H. L., & da Cruz, L.
- Venue
- British Medical Bulletin
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-02-12
- Volume
- 109
- Issue
- 1
- Pages
- 31-44
- ISSN
- 0007-1420 (ISSN-L)
- 1471-8391
- OpenAlex
- W2150151463
- Cited by
- 89
- References
- 13
- FWCI
- 5.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.