Pulse Oximetry: Theory and Applications for Noninvasive Monitoring
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Noninvasive measurement of arterial oxygen saturation (SaO2) by pulse oximetry is widely acknowledged to be one of the most important technological advances in monitoring clinical patients. Pulse oximeters compute SaO2 by measuring differences in the visible and near infrared absorbances of fully oxygenated and deoxygenated arterial blood. Unlike clinical blood gas analyzers, which require a sample of blood from the patient and can provide only intermittent measurement of patient oxygenation, pulse oximeters provide continuous, safe, and instantaneous measurement of blood oxygenation. Here I review the theoretical background behind this advanced technology, instrumentation requirements, practical instrument calibration, common features of commercial pulse oximeters, specific clinical applications, and performance limitations of pulse oximeters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
YELDERMAN, M., & NEW, W. (1983) · Anesthesiology · doi:10.1097/00000542-198310000-00015 · Cited by 486
Spectrophotometric monitoring of arterial oxygen saturation in the fingertip
Yoshiya, I., Shimada, Y., & Tanaka, K. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442476 · Cited by 261
History of blood gas analysis.
Jw, S., & Astrup, P. (1987) · PubMed · Cited by 196
Principles of pulse oximetry: theoretical and practical considerations.
Alexander, C. M., Teller, L. E., & Gross, J. B. (1989) · PubMed · Cited by 175
Improvement of the earpiece oximeter
Aoyagi, T. (1974) · Medical Entomology and Zoology · Cited by 86
A clinical evaluation of the accuracy of the Nellcor N-100 and Ohmeda 3700 pulse oximeters
Cecil, W. T., Thorpe, K. J., Fibuch, E. E., & Tuohy, G. F. (1988) · Journal of Clinical Monitoring · doi:10.1007/bf01618105 · Cited by 51
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Lim, H., Kim, H. S., Qazi, R., Kwon, Y., Jeong, J., & Yeo, W. (2020) · Advanced Materials · doi:10.1002/adma.201901924 · Cited by 1,002
Gil, E., Orini, M., Bailón, R., Vergara, J. M., Mainardi, L., & Laguna, P. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/015 · Cited by 461
Physiological parameter monitoring from optical recordings with a mobile phone
Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163157 · Cited by 452
“genated hemoglobin, but the infrared wavelength is less so and is used as a reference [14].”
Self-citationLi, Q., Mark, R. G., & Clifford, G. D. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/1/002 · Cited by 426
Organic Light‐Emitting Diodes: Pushing Toward the Limits and Beyond
Song, J., Lee, H., Jeong, E. G., Choi, K. C., & Yoo, S. (2020) · Advanced Materials · doi:10.1002/adma.201907539 · Cited by 409
Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Khalil, O. S. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.2.165 · Cited by 331
Skin bioelectronics towards long-term, continuous health monitoring
Wang, Y., Haick, H., Guo, S., Wang, C., Lee, S., Yokota, T., & Someya, T. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00207h · Cited by 318
Fantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/6/308 · Cited by 277
“This result supports the hypothesis that the pulsatile component measured in the brain originates from the arterial compartment (Mendelson 1992, Kohl et al 1998), even though more accurate spectral measurements are required to fully address this point.”
Lee, H., Kim, E., Lee, Y., Kim, H., Lee, J., Kim, M., Yoo, H.-J., & Yoo, S. (2018) · Science Advances · doi:10.1126/sciadv.aas9530 · Cited by 274
New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring
van Gastel, M., Stuijk, S., & de Haan, G. (2016) · Scientific Reports · doi:10.1038/srep38609 · Cited by 253
Investigating a smartphone imaging unit for photoplethysmography
Jonathan, E., & Leahy, M. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/11/n01 · Cited by 177
Introducing Contactless Blood Pressure Assessment Using a High Speed Video Camera
Jeong, I. C., & Finkelstein, J. (2016) · Journal of Medical Systems · doi:10.1007/s10916-016-0439-z · Cited by 160
Monitoring in the Intensive Care
Kipnis, E., Ramsingh, D., Bhargava, M., Dincer, E., Cannesson, M., Broccard, A., Vallet, B., Bendjelid, K., & Thibault, R. (2012) · Critical Care Research and Practice · doi:10.1155/2012/473507 · Cited by 87
“, shivering or seizures) [117, 118], and having electromagnetic fields such as those created by MRI machines, cellular phones, and electrocautery [119, 120].”
Device and method for noninvasive glucose assessment
Segman, Y. (. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818763457 · Cited by 55
Investigating the effects of temperature on photoplethysmography
Khan, M., Pretty, C. G., Amies, A. C., Elliott, R., Shaw, G. M., & Chase, J. G. (2015) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2015.10.166 · Cited by 41
Perfusion Changes at the Forehead Measured by Photoplethysmography during a Head-Down Tilt Protocol
Ysehak Abay, T., Shafqat, K., & Kyriacou, P. A. (2019) · Biosensors · doi:10.3390/bios9020071 · Cited by 22
Comparing peripheral limb and forehead vital sign monitoring in newborn infants at birth
Swamy, S. K. N., Stockwell, S. J., Liu, C., Henry, C., Shipley, L., Ward, C., Mirahmadi, S., Correia, R., Morgan, S. P., Crowe, J. A., et al. (2026) · Pediatric Research · doi:10.1038/s41390-024-03651-0 · Cited by 7
Metadata
- Authors
- Mendelson, Y.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-09-01
- Volume
- 38
- Issue
- 9
- Pages
- 1601-1607
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1905603695
- Cited by
- 320
- References
- 6
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.