Risk factors for cardiac implantable electronic device infection: a systematic review and meta-analysis
Open accessAbstract
Infectious complications after cardiac implantable electronic device (CIED) implantation are increasing over time and are associated with substantial mortality and healthcare costs. The aim of this study was to systematically summarize the literature on risk factors for infection after pacemaker, implantable cardioverter-defibrillator, and cardiac resynchronization therapy device implantation. Electronic searches (up to January 2014) were performed in PubMed, Scopus, and Web of Science databases. Sixty studies (21 prospective, 9 case-control, and 30 retrospective cohort studies) met the inclusion criteria. The average device infection rate was 1-1.3%. In the meta-analysis, significant host-related risk factors for infection included diabetes mellitus (odds ratio (OR) [95% confidence interval] = 2.08 [1.62-2.67]), end-stage renal disease (OR = 8.73 [3.42-22.31]), chronic obstructive pulmonary disease (OR = 2.95 [1.78-4.90]), corticosteroid use (OR = 3.44 [1.62-7.32]), history of the previous device infection (OR = 7.84 [1.94-31.60]), renal insufficiency (OR = 3.02 [1.38-6.64]), malignancy (OR = 2.23 [1.26-3.95]), heart failure (OR = 1.65 [1.14-2.39]), pre-procedural fever (OR = 4.27 [1.13-16.12]), anticoagulant drug use (OR = 1.59 [1.01-2.48]), and skin disorders (OR = 2.46 [1.04-5.80]). Regarding procedure-related factors, post-operative haematoma (OR = 8.46 [4.01-17.86]), reintervention for lead dislodgement (OR = 6.37 [2.93-13.82]), device replacement/revision (OR = 1.98 [1.46-2.70]), lack of antibiotic prophylaxis (OR = 0.32 [0.18-0.55]), temporary pacing (OR = 2.31 [1.36-3.92]), inexperienced operator (OR = 2.85 [1.23-6.58]), and procedure duration (weighted mean difference = 9.89 [0.52-19.25]) were all predictors of CIED infection. Among device-related characteristics, abdominal pocket (OR = 4.01 [2.48-6.49]), epicardial leads (OR = 8.09 [3.46-18.92]), positioning of two or more leads (OR = 2.02 [1.11-3.69]), and dual-chamber systems (OR = 1.45 [1.02-2.05]) predisposed to device infection. This systematic review on risk factors for CIED infection may contribute to developing better infection control strategies for high-risk patients and can also help risk assessment in the management of device revisions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
Duval, S., & Tweedie, R. (2000) · Biometrics · doi:10.1111/j.0006-341x.2000.00455.x · Cited by 14,099
Durack, D. T., Lukes, A. S., Bright, D. K., & Service, D. E. (1994) · The American Journal of Medicine · doi:10.1016/0002-9343(94)90143-0 · Cited by 2,572
Perioperative Management of Antithrombotic Therapy
Douketis, J. D., Spyropoulos, A. C., Spencer, F. A., Mayr, M., Jaffer, A. K., Eckman, M. H., Dunn, A. S., & Kunz, R. (2012) · Chest · doi:10.1378/chest.11-2298 · Cited by 1,641
Baddour, L. M., Epstein, A. E., Erickson, C. C., Knight, B. P., Levison, M. E., Lockhart, P. B., Masoudi, F. A., Okum, E. J., Wilson, W. R., Beerman, L. B., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.192665 · Cited by 1,030
Greenspon, A. J., Patel, J. D., Lau, E., Ochoa, J. A., Frisch, D. R., Ho, R. T., Pavri, B. B., & Kurtz, S. M. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.04.033 · Cited by 780
Management and Outcome of Permanent Pacemaker and Implantable Cardioverter-Defibrillator Infections
Sohail, M. R., Uslan, D. Z., Khan, A. H., Friedman, P. A., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., Stoner, S., & Baddour, L. M. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.072 · Cited by 751
Klug, D., Balde, M., Pavin, D., Hidden-Lucet, F., Clementy, J., Sadoul, N., Rey, J. L., Lande, G., Lazarus, A., Victor, J., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.678664 · Cited by 700
Pacemaker or Defibrillator Surgery without Interruption of Anticoagulation
Birnie, D. H., Healey, J. S., Wells, G. A., Verma, A., Tang, A. S., Krahn, A. D., Simpson, C. S., Ayala-Paredes, F., Coutu, B., Leiria, T. L. L., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1302946 · Cited by 579
Daubert, J.-C., Saxon, L., Adamson, P. B., Auricchio, A., Berger, R. D., Beshai, J. F., Breithard, O., Brignole, M., Cleland, J., DeLurgio, D. B., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.07.025 · Cited by 467
Permanent Pacemaker and Implantable Cardioverter Defibrillator Infection: A Population-Based Study
Uslan, D. Z. (2007) · Archives of Internal Medicine · doi:10.1001/archinte.167.7.669 · Cited by 391
Rising Rates of Cardiac Rhythm Management Device Infections in the United States: 1996 through 2003
Voigt, A., Shalaby, A., & Saba, S. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.05.016 · Cited by 379
Johansen, J. B., Jorgensen, O. D., Moller, M., Arnsbo, P., Mortensen, P. T., & Nielsen, J. C. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq497 · Cited by 376
Antibiotic Prophylaxis for Permanent Pacemaker Implantation: A Meta-Analysis
Da Costa, A., Kirkorian, G., Cucherat, M., Delahaye, F., Chevalier, P., Cerisier, A., Isaaz, K., & Touboul, P. (1998) · Circulation · doi:10.1161/01.cir.97.18.1796 · Cited by 362
Mortality and Cost Associated With Cardiovascular Implantable Electronic Device Infections
Sohail, M. R. (2011) · Archives of Internal Medicine · doi:10.1001/archinternmed.2011.441 · Cited by 350
de Oliveira, J. C., Martinelli, M., Nishioka, S. A. D., Varejão, T., Uipe, D., Pedrosa, A. A. A., Costa, R., & Danik, S. B. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.108.795906 · Cited by 349
Chamis, A. L., Peterson, G. E., Cabell, C. H., Corey, G. R., Sorrentino, R. A., Greenfield, R. A., Ryan, T., Reller, L. B., & Fowler, V. G. (2001) · Circulation · doi:10.1161/hc3401.095097 · Cited by 292
Risk Factor Analysis of Permanent Pacemaker Infection
Sohail, M. R., Uslan, D. Z., Khan, A. H., Friedman, P. A., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., Stoner, S. M., & Baddour, L. M. (2007) · Clinical Infectious Diseases · doi:10.1086/518889 · Cited by 288
Cardiac implantable electronic device infections: Presentation, management, and patient outcomes
Tarakji, K. G., Chan, E. J., Cantillon, D. J., Doonan, A. L., Hu, T., Schmitt, S., Fraser, T. G., Kim, A., Gordon, S. M., & Wilkoff, B. L. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2010.05.016 · Cited by 286
Complications Related to Permanent Pacemaker Therapy
KIVINIEMI, M. S., PIRNES, M. A., ERÄNEN, H. J. K., KETTUNEN, R. V. J., & HARTIKAINEN, J. E. K. (1999) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1999.tb00534.x · Cited by 261
Task Force Chairs, Daubert, J.-C., Saxon, L., Adamson, P. B., Auricchio, A., Berger, R. D., Beshai, J. F., Breithard, O., Brignole, M., Cleland, J., et al. (2012) · Europace · doi:10.1093/europace/eus222 · Cited by 256
Aggarwal, R. K., Connelly, D. T., Ray, S. G., Ball, J., & Charles, R. G. (1995) · Heart · doi:10.1136/hrt.73.6.571 · Cited by 254
Risk factors and time delay associated with cardiac device infections: Leiden device registry
Lekkerkerker, J. C., van Nieuwkoop, C., Trines, S. A., van der Bom, J. G., Bernards, A., van de Velde, E. T., Bootsma, M., Zeppenfeld, K., Jukema, J. W., Borleffs, J.-W., et al. (2009) · Heart · doi:10.1136/hrt.2008.151985 · Cited by 234
Pocket Hematoma After Pacemaker or Implantable Cardioverter Defibrillator Surgery
Wiegand, U. K. H., LeJeune, D., Boguschewski, F., Bonnemeier, H., Eberhardt, F., Schunkert, H., & Bode, F. (2004) · Chest · doi:10.1378/chest.126.4.1177 · Cited by 223
Renal Insufficiency and the Risk of Infection from Pacemaker or Defibrillator Surgery
BLOOM, H., HEEKE, B., LEON, A., MERA, F., DELURGIO, D., BESHAI, J., & LANGBERG, J. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00307.x · Cited by 220
Early Complications After Dual Chamber Versus Single Chamber Pacemaker Implantation
CHAUHAN, A., GRACE, A. A., NEWELL, S. A., STONE, D. L., SHAPIRO, L. M., SCHOFIELD, P. M., & PETCH, M. C. (1994) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1994.tb03791.x · Cited by 217
Al-Khatib, S. M., Lucas, F. L., Jollis, J. G., Malenka, D. J., & Wennberg, D. E. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.04.063 · Cited by 194
NERY, P. B., FERNANDES, R., NAIR, G. M., SUMNER, G. L., RIBAS, C. S., MENON, S. M. D., WANG, X., KRAHN, A. D., MORILLO, C. A., CONNOLLY, S. J., et al. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01690.x · Cited by 188
Permanent pacemaker infections: Characterization and management
Choo, M. H., Holmes, D. R., Gersh, B. J., Maloney, J. D., Merideth, J., Pluth, J. R., & Trusty, J. (1981) · The American Journal of Cardiology · doi:10.1016/0002-9149(81)90088-6 · Cited by 177
Krahn, A. D., Lee, D. S., Birnie, D., Healey, J. S., Crystal, E., Dorian, P., Simpson, C. S., Khaykin, Y., Cameron, D., Janmohamed, A., et al. (2011) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.110.959791 · Cited by 168
Late complications following permanent pacemaker implantation or elective unit replacement
Harcombe, A. A., Newell, S. A., Ludman, P. F., Wistow, T. E., Sharples, L. D., Schofield, P. M., Stone, D. L., Shapiro, L. M., Cole, T., & Petch, M. C. (1998) · Heart · doi:10.1136/hrt.80.3.240 · Cited by 163
USLAN, D. Z., GLEVA, M. J., WARREN, D. K., MELA, T., CHUNG, M. K., GOTTIPATY, V., BORGE, R., DAN, D., SHINN, T., MITCHELL, K., et al. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2011.03257.x · Cited by 160
Mittal, S., Shaw, R. E., Michel, K., Palekar, R., Arshad, A., Musat, D., Preminger, M., Sichrovsky, T., & Steinberg, J. S. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2013.12.013 · Cited by 158
Palmisano, P., Accogli, M., Zaccaria, M., Luzzi, G., Nacci, F., Anaclerio, M., & Favale, S. (2013) · EP Europace · doi:10.1093/europace/eus337 · Cited by 155
Microbiology of cardiac implantable electronic device infections
Bongiorni, M. G., Tascini, C., Tagliaferri, E., Cori, A. D., Soldati, E., Leonildi, A., Zucchelli, G., Ciullo, I., & Menichetti, F. (2012) · EP Europace · doi:10.1093/europace/eus044 · Cited by 155
MacFadden, D. R., Crystal, E., Krahn, A. D., Mangat, I., Healey, J. S., Dorian, P., BIRNIE, D. H., Simpson, C. S., Khaykin, Y., Pintér, A., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-156-3-201202070-00007 · Cited by 149
Prevalence and risk factors related to infections of cardiac resynchronization therapy devices
Romeyer-Bouchard, C., Costa, A. D., Dauphinot, V., Messier, M., Bisch, L., Samuel, B., Lafond, P., Ricci, P., & Isaaz, K. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp421 · Cited by 144
Risk Factors for Mortality in Patients With Cardiac Device-Related Infection
Baman, T. S., Gupta, S. K., Valle, J. A., & Yamada, E. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.816868 · Cited by 139
Peterson, P. N., Varosy, P. D., Heidenreich, P. A., Wang, Y., Dewland, T. A., Curtis, J. P., Go, A. S., Greenlee, R. T., Magid, D. J., Normand, S. T., et al. (2013) · JAMA · doi:10.1001/jama.2013.4982 · Cited by 136
End-Stage Renal Disease Predicts Complications in Pacemaker and ICD Implants
TOMPKINS, C. M., McLean, R. C., Cheng, A., Brinker, J., Marine, J. E., Nazarian, S., SPRAGG, D. D., Sinha, S. K., Halperin, H. R., Tomaselli, G. F., et al. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02066.x · Cited by 126
Mela, T., McGovern, B. A., Garan, H., Vlahakes, G. J., Torchiana, D. F., Ruskin, J. N., & Galvin, J. M. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01845-8 · Cited by 122
Charytan, D. M., Patrick, A. R., Liu, J., Setoguchi, S., Herzog, C. A., Brookhart, M. A., & Winkelmayer, W. C. (2011) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2011.03.026 · Cited by 121
Armaganijan, L., Toff, W. D., Nielsen, J. C., Andersen, H., Connolly, S. J., Ellenbogen, K. A., & Healey, J. S. (2011) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2011.03240.x · Cited by 117
Increased Complication Rates of Cardiac Rhythm Management Devices in ESRD Patients
Dasgupta, A., Montalvo, J., Medendorp, S., Lloyd‐Jones, D. M., Ghossein, C., Goldberger, J. J., & PASSMAN, R. S. (2007) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2007.02.272 · Cited by 113
Pakarinen, S., Oikarinen, L., & Toivonen, L. (2009) · EP Europace · doi:10.1093/europace/eup361 · Cited by 111
Bloom, H. L., Constantin, L., DAN, D., Lurgio, D. B. D., El‐Chami, M. F., Ganz, L. I., Gleed, K., Hackett, F. K., Kanuru, N. K., Lerner, D. J., et al. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02931.x · Cited by 109
Implantable Cardiac Device Procedures in Older Patients: Use and In-Hospital Outcomes
Swindle, J. P., Rich, M. W., McCann, P., Burroughs, T. E., & Hauptman, P. J. (2010) · Archives of Internal Medicine · doi:10.1001/archinternmed.2010.30 · Cited by 103
Landolina, M., Gasparini, M., Lunati, M., Iacopino, S., Boriani, G., Bonanno, C., Vado, A., Proclemer, A., Capucci, A., Zucchiatti, C., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.015024 · Cited by 103
Uslan, D. Z., Dowsley, T. F., Sohail, M. R., Hayes, D. L., Friedman, P. A., Wilson, W. R., Steckelberg, J. M., & Baddour, L. M. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02565.x · Cited by 102
Pacemaker Infections: A 10-Year Experience
Catanchin, A., Murdock, C. J., & Athan, E. (2007) · Heart Lung and Circulation · doi:10.1016/j.hlc.2007.02.097 · Cited by 98
Risk factors for infection of implantable cardiac devices: data from a registry of 2496 patients
Herce, B., Nazeyrollas, P., Lesaffre, F., Sandras, R., Chabert, J. P., Martin, A., Tassan‐Mangina, S., Bui, H. T., & Metz, D. (2012) · EP Europace · doi:10.1093/europace/eus284 · Cited by 96
Kolek, M. J., DRESEN, W. F., Wells, Q. S., & Ellis, C. R. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12063 · Cited by 90
Clinical Predictors of Cardiovascular Implantable Electronic Device‐Related Infective Endocarditis
LE, K. Y., Sohail, M. R., Friedman, P. A., Uslan, D. Z., CHA, S. S., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., Baddour, L. M., & for the Mayo Cardiovascular Infections Study Group (2011) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02991.x · Cited by 88
Borleffs, C. J. W., Thijssen, J., de Bie, M. K., van Rees, J. B., van Welsenes, G. H., van Erven, L., Bax, J. J., Cannegieter, S. C., & Schalij, M. J. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02780.x · Cited by 82
Trappe, H., PFITZNER, P., Klein, H., & WENZLAFF, P. (1995) · Heart · doi:10.1136/hrt.73.1.20 · Cited by 79
Infections with Nonthoracotomy Implantable Cardioverter Defibrillators: Can These Be Prevented?
Smith, P. N., Vidaillet, H. J., Jr., Hayes, J. J., WETHINGTON, P. J., VOSHAGE‐STAHL, L., HULL, M. L., & Broste, S. K. (1998) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1998.tb01060.x · Cited by 71
Outcome of advisory implantable cardioverter-defibrillator replacement: One-year follow-up
Gould, P. A., Gula, L. J., Champagne, J., Healey, J. S., Cameron, D., Simpson, C., Thibault, B., Pintér, A., Tung, S., Sterns, L. D., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.09.020 · Cited by 70
Schuchert, A., Muto, C., Maounis, T., Frank, R., Boulogne, E., Polauck, A., Padeletti, L., & for the MASCOT study group (2012) · EP Europace · doi:10.1093/europace/eus247 · Cited by 67
Management of Recalled Pacemakers and Implantable Cardioverter-Defibrillators
Amin, M. S., Matchar, D. B., Wood, M. A., & Ellenbogen, K. A. (2006) · JAMA · doi:10.1001/jama.296.4.412 · Cited by 62
Prophylactic antibiotics and the insertion of permanent transvenous cardiac pacemakers
Hartstein, A. I., Jackson, J., & Gilbert, D. N. (1978) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)41289-0 · Cited by 52
Cengiz, M., Okutucu, S., Aşçıoğlu, S., Şahin, A., Aksoy, H., Deveci, O. S., Kaya, E. B., Aytemir, K., Kabakçı, G., Tokgözoğlu, L., et al. (2010) · Clinical Cardiology · doi:10.1002/clc.20765 · Cited by 52
Bertaglia, E., Zerbo, F., Zardo, S., Barzan, D., Zoppo, F., & Pascotto, P. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00294.x · Cited by 49
Implantable electrophysiologic cardiac device infections: a risk factor analysis
Raad, D., Irani, J., Akl, E., Choueiri, S. C., Azar, E., Abboud, J. M., & Afif, C. (2012) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-012-1655-1 · Cited by 40
Outcome of single-chamber, ventricular pacemakers with transvenous leads implanted in children
Silvetti, M. S., Drago, F., Marcora, S. A., et al. (2007) · EP Europace · doi:10.1093/europace/eum164 · Cited by 35
Economic implications of infections of implantable cardiac devices in a single institution
Kuehn, C., Graf, K., Heuer, W., Hilfiker, A., Chaberny, I. F., Stiesch, M., & Haverich, A. (2009) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2009.10.018 · Cited by 33
Spinler, S. A., Nawarskas, J. J., Foote, E. F., Sabapathi, D., Connors, J. E., & Marchlinski, F. E. (1998) · Clinical Infectious Diseases · doi:10.1086/520299 · Cited by 30
Infrequent physician use of implantable cardioverter-defibrillators risks patient safety
Lyman, S., Sedrakyan, A., Do, H. T., Razzano, R. A., & Mushlin, A. I. (2011) · Heart · doi:10.1136/hrt.2011.226282 · Cited by 21
Obeid, K. M., Szpunar, S. M., & Khatib, R. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2012.03438.x · Cited by 20
Kron, J. (2003) · Cardiac Electrophysiology Review · doi:10.1023/b:cepr.0000023163.67758.b1 · Cited by 19
Marschall, J., Hopkins-Broyles, D., Jones, M., Fraser, V. J., & Warren, D. K. (2007) · Infection Control and Hospital Epidemiology · doi:10.1086/520744 · Cited by 13
Cited by
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
2023 ESC Guidelines for the management of endocarditis
Delgado, V., Ajmone Marsan, N., de Waha, S., Bonaros, N., Brida, M., Burri, H., Caselli, S., Doenst, T., Ederhy, S., Erba, P. A., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad193 · Cited by 1,754
Kusumoto, F. M., Schoenfeld, M. H., Wilkoff, B. L., Berul, C. I., Birgersdotter-Green, U. M., Carrillo, R., Cha, Y.-M., Clancy, J., Deharo, J.-C., Ellenbogen, K. A., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.09.001 · Cited by 1,199
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Metadata
- Authors
- Polyzos, K. A., Konstantelias, A. A., & Falagas, M. E.
- Venue
- EP Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-04-29
- Volume
- 17
- Issue
- 5
- Pages
- 767-777
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2153172728
- Cited by
- 493
- References
- 72
- FWCI
- 6.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.