Systolic Pressure Variation as a Guide to Fluid Therapy in Patients with Sepsis-induced Hypotension
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Background: Monitoring left ventricular preload is critical to achieve adequate fluid resuscitation in patients with hypotension and sepsis. This prospective study tested the correlation of the pulmonary artery occlusion pressure, the left ventricular end-diastolic area index measured by transesophageal echocardiography, the arterial systolic pressure variation (the difference between maximal and minimal systolic blood pressure values during one mechanical breath), and its delta down (dDown) component (= apneic - minimum systolic blood pressure) with the response of cardiac output to volume expansion during sepsis. Methods: Preload parameters were measured at baseline and during graded volume expansion (increments of 500 ml) in 15 patients with sepsis-induced hypotension who required mechanical ventilation. Each volume-loading step (VLS) was classified as a responder (increase in stroke volume index > or = 15%) or a nonresponder. Successive VLSs were performed until a nonresponder VLS was obtained. Results: Thirty-five VLSs (21 responders) were performed. Fluid loading caused an overall significant increase in pulmonary artery occlusion pressure and end-diastolic area index, and a significant decrease in systolic pressure variation and delta down (P < 0.01). There was a significant difference between responder and nonresponder VLSs in end-diastolic area index, systolic pressure variation, and dDown, but not in pulmonary artery occlusion pressure. Receiver-operator curve analysis showed that dDown was a more accurate indicator of the response of stroke volume index to volume loading than end-diastolic area index and pulmonary artery occlusion pressure. A dDown component of more than 5 mmHg indicated that the stroke volume index would increase in response to a subsequent fluid challenge (positive and negative predictive values: 95% and 93%, respectively). Conclusion: The dDown component of the systolic pressure variation is a sensitive indicator of the response of cardiac output to volume infusion in patient with sepsis-induced hypotension who require mechanical ventilation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
Profound but Reversible Myocardial Depression in Patients with Septic Shock
PARKER, M. M., SHELHAMER, J. H., BACHARACH, S. L., GREEN, M. V., NATANSON, C., FREDERICK, T. M., DAMSKE, B. A., & PARRILLO, J. E. (1984) · Annals of Internal Medicine · doi:10.7326/0003-4819-100-4-483 · Cited by 1,585
Pathogenetic Mechanisms of Septic Shock
Epstein, F. H., & Parrillo, J. E. (1993) · New England Journal of Medicine · doi:10.1056/nejm199305203282008 · Cited by 1,548
Pepe, P., & Marini, J. J. (1982) · PubMed · doi:10.1164/arrd.1982.126.1.166 · Cited by 672
Perel, A., Pizov, R., & Cotev, S. (1987) · Anesthesiology · doi:10.1097/00000542-198710000-00009 · Cited by 403
Swenson, J. D., Harkin, C. P., Pace, N. L., Astle, K. L., & Bailey, P. L. (1996) · Anesthesia & Analgesia · doi:10.1213/00000539-199612000-00003 · Cited by 95
Teboul, J., Besbes, M., Andrivet, P., Axler, O., Douguet, D., Zelter, M., Lemaire, F., & Brun‐Buisson, C. (1992) · Journal of Critical Care · doi:10.1016/0883-9441(92)90005-r · Cited by 94
Cited by
MICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458
Predicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367
Marik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272
The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
Feissel, M., Michard, F., Faller, J.-P., & Teboul, J.-L. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2233-5 · Cited by 967
A Rational Approach to Perioperative Fluid Management
Chappell, D., Jacob, M., Hofmann-Kiefer, K., Conzen, P., & Rehm, M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e3181863117 · Cited by 909
Changes in Arterial Pressure during Mechanical Ventilation
Michard, F. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00026 · Cited by 713
Pulse pressure variations to predict fluid responsiveness: influence of tidal volume
De Backer, D., Heenen, S., Piagnerelli, M., Koch, M., & Vincent, J.-L. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2586-4 · Cited by 706
Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge*
Osman, D., Ridel, C., Ray, P., Monnet, X., Anguel, N., Richard, C., & Teboul, J.-L. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000249851.94101.4f · Cited by 695
Feissel, M., Michard, F., Mangin, I., Ruyer, O., Faller, J.-P., & Teboul, J.-L. (2001) · CHEST · doi:10.1378/chest.119.3.867 · Cited by 612
Practice parameters for hemodynamic support of sepsis in adult patients: 2004 update
Hollenberg, S. M., Ahrens, T. S., Annane, D., Astiz, M. E., Chalfin, D. B., Dasta, J. F., Heard, S. O., Martin, C., Napolitano, L. M., Susla, G. M., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000139761.05492.d6 · Cited by 521
Murray, M. J., DeBlock, H., Erstad, B., Gray, A., Jacobi, J., Jordan, C., McGee, W., McManus, C., Meade, M., Nix, S., et al. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000002027 · Cited by 517
Antonelli, M., Levy, M., Andrews, P. J. D., Chastre, J., Hudson, L. D., Manthous, C., Meduri, G. U., Moreno, R. P., Putensen, C., Stewart, T., et al. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0531-4 · Cited by 466
Vincent, J.-L., & Weil, M. H. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000214677.76535.a5 · Cited by 424
Stroke Volume Variation as a Predictor of Fluid Responsiveness in Patients Undergoing Brain Surgery
Berkenstadt, H., Margalit, N., Hadani, M., Friedman, Z., Segal, E., Villa, Y., & Perel, A. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200104000-00034 · Cited by 412
Perioperative Fluid Management and Clinical Outcomes in Adults
Grocott, M. P. W., Mythen, M. G., & Gan, T. J. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000148691.33690.ac · Cited by 404
Lichtenstein, D. A., Mezière, G. A., Lagoueyte, J.-F., Biderman, P., Goldstein, I., & Gepner, A. (2009) · Chest · doi:10.1378/chest.09-0001 · Cited by 401
Lamia, B., Ochagavia, A., Monnet, X., Chemla, D., Richard, C., & Teboul, J.-L. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0646-7 · Cited by 393
Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care
Bendjelid, K., & Romand, J.-A. (2003) · Intensive Care Medicine · doi:10.1007/s00134-002-1615-9 · Cited by 366
Global End-Diastolic Volume as an Indicator of Cardiac Preload in Patients With Septic Shock *
Michard, F., Alaya, S., Zarka, V., Bahloul, M., Richard, C., & Teboul, J.-L. (2003) · Chest · doi:10.1378/chest.124.5.1900 · Cited by 352
Boulain, T., Achard, J.-M., Teboul, J.-L., Richard, C., Perrotin, D., & Ginies, G. (2002) · Chest · doi:10.1378/chest.121.4.1245 · Cited by 351
Muller, L., Toumi, M., Bousquet, P.-J., Riu-Poulenc, B., Louart, G., Candela, D., Zoric, L., Suehs, C., de La Coussaye, J.-E., Molinari, N., et al. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318229a500 · Cited by 343
Monnet, X., Osman, D., Ridel, C., Lamia, B., Richard, C., & Teboul, J.-L. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181968fe1 · Cited by 301
Perioperative fluid therapy: a statement from the international Fluid Optimization Group
Navarro, L. H. C., Bloomstone, J. A., Auler, J. O. C., Cannesson, M., Rocca, G. D., Gan, T. J., Kinsky, M., Magder, S., Miller, T. E., Mythen, M., et al. (2015) · Perioperative Medicine · doi:10.1186/s13741-015-0014-z · Cited by 298
Prometheus® – a new extracorporeal system for the treatment of liver failure☆
Rifai, K., Ernst, T., Kretschmer, U., Bahr, M. J., Schneider, A., Hafer, C., Haller, H., Manns, M. P., & Fliser, D. (2003) · Journal of Hepatology · doi:10.1016/s0168-8278(03)00468-9 · Cited by 291
Preisman, S., Kogan, S., Berkenstadt, H., & Perel, A. (2005) · British Journal of Anaesthesia · doi:10.1093/bja/aei262 · Cited by 269
Reuter, D. A., Bayerlein, J., Goepfert, M. S. G., Weis, F. C., Kilger, E., Lamm, P., & Goetz, A. E. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1649-7 · Cited by 265
Hemodynamic Instability in Sepsis: Bedside Assessment by Doppler Echocardiography
Vieillard-Baron, A., Prin, S., Chergui, K., Dubourg, O., & Jardin, F. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200306-816cc · Cited by 265
Benes, J., Giglio, M., Brienza, N., & Michard, F. (2014) · Critical Care · doi:10.1186/s13054-014-0584-z · Cited by 257
World Interactive Network Focused On Critical UltraSound ECHO-ICU Group, Price, S., Via, G., Sloth, E., Guarracino, F., Breitkreutz, R., Catena, E., & Talmor, D. (2008) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-6-49 · Cited by 255
Cannesson, M., Musard, H., Desebbe, O., Boucau, C., Simon, R., Hénaine, R., & Lehot, J.-J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318192a36b · Cited by 214
Arterial Pulse Pressure Variation with Mechanical Ventilation
Teboul, J.-L., Monnet, X., Chemla, D., & Michard, F. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201801-0088ci · Cited by 200
Heenen, S., De Backer, D., & Vincent, J.-L. (2006) · Critical Care · doi:10.1186/cc4970 · Cited by 197
“These dynamic indices of preload can better predict the individual response to fluid loading than static indices [1-5].”
BackgroundWorkgroup, F. T. P. Q. I. (. I., Thiele, R. H., Raghunathan, K., Brudney, C. S., Lobo, D. N., Martin, D., Senagore, A., Cannesson, M., Gan, T. J., Mythen, M. M. G., et al. (2016) · Perioperative Medicine · doi:10.1186/s13741-016-0049-9 · Cited by 197
“As cardiorespiratory interactions depend on cyclic changes in intrathoracic pressure producing corresponding cyclic changes in venous return, thresholds for “fluid responsiveness” that utilize respiratory variation in pulse pressure or systolic pressure are conditional on tidal volumes of 8–12 mL/kg (predicted body we…”
BackgroundInfluentialCannesson, M., Besnard, C., Durand, P. G., Bohé, J., & Jacques, D. (2005) · Critical Care · doi:10.1186/cc3799 · Cited by 186
“In mechanically ventilated patients, respiratory variations in systemic systolic pressure (∆Ps) have been proposed to be a good indicator of fluid responsiveness [2,3].”
BackgroundRespiratory variations of aortic VTI: a new index of hypovolemia and fluid responsiveness
Slama, M., Masson, H., Teboul, J.-L., Arnout, M.-L., Susic, D., Frohlich, E., & Andrejak, M. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00308.2002 · Cited by 172
“LV end-diastolic area has been shown to be a sensitive index of volume status (4, 5, 8, 14, 16, 18, 19).”
BackgroundResultInfluentialAcute left ventricular dilatation and shock-induced myocardial dysfunction*
Bouhemad, B., Nicolas-Robin, A., Arbelot, C., Arthaud, M., Féger, F., & Rouby, J.-J. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e318194ac44 · Cited by 172
“Another echocardiographic study reported normal values of end-diastolic left ventricular volume at the beginning of septic shock (9, 10).”
BackgroundNon-invasive prediction of fluid responsiveness during major hepatic surgery † ‡
Solus-Biguenet, H., Fleyfel, M., Tavernier, B., Kipnis, E., Onimus, J., Robin, E., Lebuffe, G., Decoene, C., Pruvot, F. R., & Vallet, B. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael250 · Cited by 169
Self-citationFunctional Hemodynamic Monitoring
Pinsky, M. R. (2015) · Critical Care Clinics · doi:10.1016/j.ccc.2014.08.005 · Cited by 168
Echocardiographic measurement of fluid responsiveness
Charron, C., Caille, V., Jardin, F., & Vieillard-Baron, A. (2006) · Current Opinion in Critical Care · doi:10.1097/01.ccx.0000224870.24324.cc · Cited by 167
Monitoring in the Intensive Care
Kipnis, E., Ramsingh, D., Bhargava, M., Dincer, E., Cannesson, M., Broccard, A., Vallet, B., Bendjelid, K., & Thibault, R. (2012) · Critical Care Research and Practice · doi:10.1155/2012/473507 · Cited by 87
“…School, 1211 Geneva 14, Switzerland 5 Centre de Recherche en Nutrition Humaine Auvergne, UMR 1019 Nutrition Humaine, INRA, Clermont Université, Service de Nutrition Clinique, CHU de Clermont-Ferrand, 63009 Clermont-Ferrand, France 6 Intensive Care Division, Geneva University Hospitals, 1211…”
Metadata
- Authors
- Tavernier, B., Makhotine, O., Lebuffe, G., Dupont, J., & Scherpereel, P.
- Venue
- Anesthesiology
- Published
- 1998-12-01
- Volume
- 89
- Issue
- 6
- Pages
- 1313-1321
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2092839265
- Cited by
- 570
- References
- 7
- FWCI
- 15.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.