High-Resolution MR Venography at 3.0 Tesla
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
PURPOSE: The aim of this study was to investigate the visualization of small venous vessels in the normal human brain at a field strength of 3 Tesla. METHODS: T2*-weighted, three-dimensional gradient-echo images were acquired by exploiting the magnetic susceptibility difference between oxygenated and deoxygenated hemoglobin in the vasculature and microvasculature. The spatial resolution was 0.5 x 0.5 x 1 mm3, and sequence parameters were varied to obtain good vessel delineation. Improved visibility of venous vessels was obtained by creating phase mask images from the magnetic resonance phase images and multiplying these by the magnitude images. Venograms were created by performing a minimum intensity projection over targeted volumes. RESULTS: Highly detailed visualization of venous structures deep in the brain and in the superficial cortical areas were obtained without administration of an exogenous contrast agent; compared with similar studies performed at 1.5 T, the echo time could be reduced from typically 40-50 ms to 17-28 ms. CONCLUSION: Imaging at high-field strength offers the possibility of improved resolution and the delineation of smaller vessels compared with lower field strengths.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,266
Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime
Yablonskiy, D. A., & Haacke, E. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320610 · Cited by 1,198
Self-citationThulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Gadolinium-enhanced MR aortography.
Prince, M. R. (1994) · Radiology · doi:10.1148/radiology.191.1.8134563 · Cited by 884
The sensitivity of the zeugmatographic experiment involving human samples
Hoult, D. I., & Lauterbur, P. C. (1979) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(79)90019-2 · Cited by 776
The intrinsic signal-to-noise ratio in NMR imaging
Edelstein, W. A., Glover, G. H., Hardy, C. J., & Redington, R. W. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030413 · Cited by 758
Small vessels in the human brain: MR venography with deoxyhemoglobin as an intrinsic contrast agent.
Reichenbach, J. R., Venkatesan, R., Schillinger, D. J., Kido, D. K., & Haacke, E. M. (1997) · Radiology · doi:10.1148/radiology.204.1.9205259 · Cited by 605
Self-citationOgawa, S., & Lee, T. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160103 · Cited by 565
Homodyne detection in magnetic resonance imaging
Noll, D. C., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.79473 · Cited by 514
Cited by
Susceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582
Self-citationSusceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1
Haacke, E. M., Mittal, S., Wu, Z., Neelavalli, J., & Cheng, Y.-C. N. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1400 · Cited by 1,113
Self-citationShenton, M. E., Hamoda, H. M., Schneiderman, J. S., Bouix, S., Pasternak, O., Rathi, Y., Vu, M.-A., Purohit, M. P., Helmer, K., Koerte, I., et al. (2012) · Brain Imaging and Behavior · doi:10.1007/s11682-012-9156-5 · Cited by 941
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Self-citationClinical applications of neuroimaging with susceptibility‐weighted imaging
Sehgal, V., Delproposto, Z., Haacke, E. M., Tong, K. A., Wycliffe, N., Kido, D. K., Xu, Y., Neelavalli, J., Haddar, D., & Reichenbach, J. R. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20404 · Cited by 427
Self-citationHigh‐resolution BOLD venographic imaging: a window into brain function
Reichenbach, J. R., & Haacke, E. M. (2001) · NMR in Biomedicine · doi:10.1002/nbm.722 · Cited by 248
“Furthermore, it has recently been demonstrated that BOLD venography is independent of the choice of the scan plane.(30,31) Collecting isotropic data in all three orientations and reformatting the sagittal and coronal image data sets to the transverse plane for comparison revealed no differences in the ability to visua…”
BackgroundMethodSelf-citationLayer-specific BOLD activation in human V1
Koopmans, P. J., Barth, M., & Norris, D. G. (2010) · Human Brain Mapping · doi:10.1002/hbm.20936 · Cited by 220
Self-citationMagnetic Resonance Imaging at 3.0 Tesla: Challenges and Advantages in Clinical Neurological Imaging
Frayne, R., Goodyear, B. G., Dickhoff, P., Lauzon, M. L., & Sevick, R. J. (2003) · Investigative Radiology · doi:10.1097/01.rli.0000073442.88269.c9 · Cited by 212
Sehgal, V., Delproposto, Z., Haddar, D., Haacke, E. M., Sloan, A. E., Zamorano, L. J., Barger, G., Hu, J., Xu, Y., Prabhakaran, K. P., et al. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20598 · Cited by 204
“These characteristics permit SWI to have exquisite sensitivity to the venous vasculature (5), blood products (such as those that occur after hemorrhage), and vascular malformations (6,7).”
BackgroundSelf-citationContribution of Susceptibility-Weighted Imaging to Acute Stroke Assessment
Hermier, M., & Nighoghossian, N. (2004) · Stroke · doi:10.1161/01.str.0000133341.74387.96 · Cited by 192
7‐T MR—from research to clinical applications?
Moser, E., Stahlberg, F., Ladd, M. E., & Trattnig, S. (2012) · NMR in Biomedicine · doi:10.1002/nbm.1794 · Cited by 187
“5 or 3 T (17), and the concept of SWI gives rise to completely new contrast possibilities at 7 T (18).”
BackgroundSelf-citationClinical applications of susceptibility weighted MR imaging of the brain – a pictorial review
Thomas, B., Somasundaram, S., Thamburaj, K., Kesavadas, C., Gupta, A. K., Bodhey, N. K., & Kapilamoorthy, T. R. (2008) · Neuroradiology · doi:10.1007/s00234-007-0316-z · Cited by 180
“About 10% of the CT-proven hematomas show no trace of hemosiderin on routine spin-echo MRI [28].”
BackgroundInfluentialNorris, D. G. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10390 · Cited by 171
“Reprinted with permission from Reichenbach et al (50).”
MethodSusceptibility‐weighted imaging: current status and future directions
Liu, S., Buch, S., Chen, Y., Choi, H., Dai, Y., Habib, C., Hu, J., Jung, J., Luo, Y., Utriainen, D., et al. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3552 · Cited by 170
“φj r ð Þ 1⁄4 γΔB r ð ÞTEþ φ0;j r ð Þ [5]”
Self-citationDeistung, A., Rauscher, A., Sedlacik, J., Stadler, J., Witoszynskyj, S., & Reichenbach, J. R. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21754 · Cited by 169
Self-citationKlohs, J., Deistung, A., Schweser, F., Grandjean, J., Dominietto, M., Waschkies, C., Nitsch, R. M., Knuesel, I., Reichenbach, J. R., & Rudin, M. (2011) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2011.118 · Cited by 83
Self-citation
Metadata
- Authors
- Reichenbach, J. R., Barth, M., Haacke, E. M., Klarhöfer, M., Kaiser, W. A., & Moser, E.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 2000-11
- Volume
- 24
- Issue
- 6
- Pages
- 949-957
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2074479388
- Cited by
- 199
- References
- 32
- FWCI
- 4.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).