Microprocessor-based ambulatory activity monitoring in stroke patients
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
PURPOSE: Recovery of ambulatory function after stroke is routinely assessed using standardized subject- or observer-rated instruments that do not directly measure ambulatory activities in the home-community setting. Accuracy of conventional pedometers in stroke patients is not established, limiting their application in mobility outcomes monitoring. This study investigates the accuracy and reliability of a mechanical pedometer versus microprocessor-based step activity monitoring (SAM) in gait-impaired hemiparetic stroke patients. METHODS: Accuracy and test-retest reliability of ankle-worn SAM and belt-worn pedometer were tested directly against hand tallied stride counts and cadence during a battery of timed walks in 16 chronic hemiparetic stroke patients. Patients performed replicate 1-min floor walks at self-selected and fastest comfortable paces, and two 6-min walks on separate days. RESULTS: SAM cadence and total stride counts are more accurate than pedometers during 1-min walks at self-selected (99 +/- 1 vs 87 +/- 11.3%, mean +/- SD, P < 0.01); fast pace (98 +/- 2.3% vs 85 +/- 15%, P < 0.01); and repeated 6-min walks performed on separate days (99 +/- 1% vs 89 +/- 12%, P < 0.01). Although SAM is highly reliable (r = 0.97, P < 0.0001) and accurate in all patients under every walking condition tested, the mechanical pedometer demonstrates this high level of accuracy in only half of stroke patients and has poor test-retest reliability (r = 0.64, P < 0.05). CONCLUSION: SAM, but not the conventional pedometer, provides accurate and reliable measures of cadence and total stride counts in hemiparetic stroke patients. Portable microprocessor-based gait monitoring offers potential to quantitatively measure home-community-based ambulatory activity levels in this population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fletcher, G. F., Balady, G., Blair, S. N., Blumenthal, J., Caspersen, C., Chaitman, B., Epstein, S., Froelicher, E. S. S., Froelicher, V. F., Pina, I. L., et al. (1996) · Circulation · doi:10.1161/01.cir.94.4.857 · Cited by 1,319
Fletcher, G. F., Blair, S. N., Blumenthal, J., Caspersen, C., Chaitman, B., Epstein, S., Falls, H., Froelicher, E. S., Froelicher, V. F., & Pina, I. L. (1992) · Circulation · doi:10.1161/01.cir.86.1.340 · Cited by 416
Sequeira, M. M., Rickenbach, M., Wietlisbach, V., Tullen, B., & Schutz, Y. (1995) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a117748 · Cited by 250
Cited by
Direct measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Reduced Ambulatory Activity After Stroke: The Role of Balance, Gait, and Cardiovascular Fitness
Michael, K. M., Allen, J. K., & Macko, R. F. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2004.12.026 · Cited by 505
Self-citationThe validity and reliability of a novel activity monitor as a measure of walking
Ryan, C. G., Grant, P. M., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.027276 · Cited by 490
Mercer, K., Giangregorio, L., Schneider, E., Chilana, P., Li, M., & Grindrod, K. (2016) · JMIR mHealth and uHealth · doi:10.2196/mhealth.4225 · Cited by 419
“However, activity trackers may be less accurate for older adults with a shuffling, abnormal, or slow gait caused by conditions such as stroke or Parkinson’s disease [31-34].”
Factors Associated With Post-Stroke Physical Activity: A Systematic Review and Meta-Analysis
Thilarajah, S., Mentiplay, B. F., Bower, K. J., Tan, D., Pua, Y. H., Williams, G., Koh, G., & Clark, R. A. (2018) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2017.09.117 · Cited by 310
How humans walk: Bout duration, steps per bout, and rest duration
Orendurff, M. S. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.11.0197 · Cited by 306
“SAMs have step count accuracy of better than 98 percent [39–41].”
BackgroundPredicting Home and Community Walking Activity Poststroke
Fulk, G. D., He, Y., Boyne, P., & Dunning, K. (2017) · Stroke · doi:10.1161/strokeaha.116.015309 · Cited by 306
Bowden, M. G., Balasubramanian, C. K., Behrman, A. L., & Kautz, S. A. (2008) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968308318837 · Cited by 305
Monitoring of Physical Activity after Stroke: A Systematic Review of Accelerometry-Based Measures
Gebruers, N., Vanroy, C., Truijen, S., Engelborghs, S., & De Deyn, P. P. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2009.10.025 · Cited by 293
Pedometer Accuracy in Nursing Home and Community-Dwelling Older Adults
CYARTO, E. V., MYERS, A. M., & TUDOR-LOCKE, C. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000113476.62469.98 · Cited by 236
Using Activity Monitors to Measure Physical Activity in Free-Living Conditions
Berlin, J. E., Storti, K. L., & Brach, J. S. (2006) · Physical Therapy · doi:10.1093/ptj/86.8.1137 · Cited by 209
George Hornby, T., Straube, D. S., Kinnaird, C. R., Holleran, C. L., Echauz, A. J., Rodriguez, K. S., Wagner, E. J., & Narducci, E. A. (2011) · Topics in Stroke Rehabilitation · doi:10.1310/tsr1804-293 · Cited by 204
Locomotor Training Progression and Outcomes After Incomplete Spinal Cord Injury
Behrman, A. L., Lawless-Dixon, A. R., Davis, S. B., Bowden, M. G., Nair, P., Phadke, C., Hannold, E. M., Plummer, P., & Harkema, S. J. (2005) · Physical Therapy · doi:10.1093/ptj/85.12.1356 · Cited by 190
Haeuber, E., Shaughnessy, M., Forrester, L. W., Coleman, K. L., & Macko, R. F. (2004) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2003.11.035 · Cited by 182
Self-citationAccuracy of 2 Activity Monitors in Detecting Steps in People With Stroke and Traumatic Brain Injury
Fulk, G. D., Combs, S. A., Danks, K. A., Nirider, C. D., Raja, B., & Reisman, D. S. (2014) · Physical Therapy · doi:10.2522/ptj.20120525 · Cited by 182
Quantification of walking mobility in neurological disorders
Pearson, O. R., Busse, M. E., van Deursen, R. W. M., & Wiles, C. M. (2004) · QJM · doi:10.1093/qjmed/hch084 · Cited by 181
“Such devices have been used successfully in populations with notable gait asymmetry, particularly amputee subjects and individuals following a stroke.(53) The accuracy and reliability of the SAM in stroke patients has been investigated, and found to offer good potential to quantify home- or community-based activity le…”
BackgroundBrandes, M., Ringling, M., Winter, C., Hillmann, A., & Rosenbaum, D. (2011) · Arthritis Care & Research · doi:10.1002/acr.20384 · Cited by 172
Factors Associated With Exercise Behavior in People With Parkinson Disease
Ellis, T., Cavanaugh, J. T., Earhart, G. M., Ford, M. P., Foreman, K. B., Fredman, L., Boudreau, J. K., & Dibble, L. E. (2011) · Physical Therapy · doi:10.2522/ptj.20100390 · Cited by 171
Ambulatory Activity Intensity Profiles, Fitness, and Fatigue in Chronic Stroke
Michael, K., & Macko, R. F. (2007) · Topics in Stroke Rehabilitation · doi:10.1310/tsr1402-5 · Cited by 166
Self-citationPhysical Activity after Stroke: A Systematic Review and Meta-Analysis
Field, M. J., Gebruers, N., Shanmuga Sundaram, T., Nicholson, S., & Mead, G. (2013) · ISRN Stroke · doi:10.1155/2013/464176 · Cited by 143
Capturing Ambulatory Activity Decline in Parkinson's Disease
Cavanaugh, J. T., Ellis, T. D., Earhart, G. M., Ford, M. P., Foreman, K. B., & Dibble, L. E. (2012) · Journal of Neurologic Physical Therapy · doi:10.1097/npt.0b013e318254ba7a · Cited by 141
Comparison of two waist-mounted and two ankle-mounted electronic pedometers
Karabulut, M., Crouter, S. E., & Bassett, D. R. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0018-3 · Cited by 139
Mudge, S., Stott, N. S., & Walt, S. E. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.07.039 · Cited by 105
Test—retest reliability of the StepWatch Activity Monitor outputs in individuals with chronic stroke
Mudge, S., & Stott, N. S. (2008) · Clinical Rehabilitation · doi:10.1177/0269215508092822 · Cited by 77
Steins, D., Dawes, H., Esser, P., & Collett, J. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-36 · Cited by 71
Validity of 2 Devices for Measuring Steps Taken by Older Adults in Assisted-Living Facilities
Bergman, R. J., Bassett, D. R., & Klein, D. A. (2008) · Journal of Physical Activity and Health · doi:10.1123/jpah.5.s1.s166 · Cited by 62
“Researchers previously changed sensitivity settings of the SAM when it was <90% accurate.(16) For this study, these parameters were set at the most-sensitive settings.”
BackgroundSkidmore, F. M. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2006.10.0130 · Cited by 60
Step count accuracy and reliability of two activity tracking devices in people after stroke
Schaffer, S. D., Holzapfel, S. D., Fulk, G., & Bosch, P. R. (2017) · Physiotherapy Theory and Practice · doi:10.1080/09593985.2017.1354412 · Cited by 54
Vanroy, C., Vissers, D., Cras, P., Beyne, S., Feys, H., Vanlandewijck, Y., & Truijen, S. (2014) · Disability and Rehabilitation · doi:10.3109/09638288.2013.859307 · Cited by 46
Adherence to Accelerometry Measurement of Community Ambulation Poststroke
Barak, S., Wu, S. S., Dai, Y., Duncan, P. W., & Behrman, A. L. (2014) · Physical Therapy · doi:10.2522/ptj.20120473 · Cited by 27
Metadata
- Authors
- MACKO, R. F., HAEUBER, E., SHAUGHNESSY, M., COLEMAN, K. L., BOONE, D. A., SMITH, G. V., & SILVER, K. H.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2002-03
- Volume
- 34
- Issue
- 3
- Pages
- 394-399
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2071857252
- Cited by
- 185
- References
- 4
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.