The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Comparison of pedometer and accelerometer measures of free-living physical activity
Abstract
PURPOSE: The purpose of this investigation was 1) to evaluate agreement between dual-mode CSA accelerometer outputs and Yamax pedometer outputs assessed concurrently under free-living conditions; 2) to determine the relationship between pedometer-steps per day and CSA-time spent in inactivity and in light-, moderate-, and vigorous-intensity activities; and 3) to identify a value of pedometer-steps per day that corresponds with a minimum of 30 CSA-min x d(-1) of moderate ambulatory activity. METHODS: Data were analyzed from 52 participants (27 men, 25 women; mean age = 38.2 +/- 12.0 yr; mean BMI = 26.4 +/- 4.5 kg x m(-2)) who were enrolled in the International Physical Activity Questionnaire study and wore both motion sensors during waking hours for 7 consecutive days. RESULTS: Participants averaged 415.0+/-159.5 CSA-counts x min(-1) x d(-1), 357,601 +/- 138,425 CSA-counts x d(-1), 11,483 +/- 3,856 CSA-steps x d(-1), and 9,638 +/- 4,030 pedometer-steps x d(-1). There was a strong relationship between all CSA outputs and pedometer outputs (r = 0.74-0.86). The mean difference in steps detected between instruments was 1845+/-2116 steps x d(-1) (CSA > pedometer; t = 6.29, P < 0.0001). There were distinct differences (effect sizes >0.80) in mean CSA-time (min x d(-1)) in moderate and vigorous activity with increasing pedometer-determined activity quartiles; no differences were noted for inactivity or light activity. Approximately 33 CSA-min x d(-1) of moderate activity corresponded with 8000 pedometer-steps x d(-1). CONCLUSION: Differences in mean steps per day detected may be due to differences in set instrument sensitivity thresholds and/or attachment. Additional studies with different populations are needed to confirm a recommended number of steps per day associated with the duration and intensity of public health recommendations for ambulatory activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Accuracy of five electronic pedometers for measuring distance walked
BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199608000-00019 · Cited by 552
Self-citationReliability assessment of pedometer activity measurements
Tryon, W. W., Pinto, L. P., & Morrison, D. F. (1991) · Journal of Psychopathology and Behavioral Assessment · doi:10.1007/bf00960737 · Cited by 34
Cited by
How Many Steps/Day Are Enough?: Preliminary Pedometer Indices for Public Health
Tudor-Locke, C., & Bassett, D. R. (2004) · Sports Medicine · doi:10.2165/00007256-200434010-00001 · Cited by 2,054
Self-citationHow many steps/day are enough? for adults
Tudor-Locke, C., Craig, C. L., Brown, W. J., Clemes, S. A., De Cocker, K., Giles-Corti, B., Hatano, Y., Inoue, S., Matsudo, S. M., Mutrie, N., et al. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-79 · Cited by 1,087
Self-citationUtility of Pedometers for Assessing Physical Activity: Convergent Validity
Tudor-Locke, C., Williams, J. E., Reis, J. P., & Pluto, D. (2002) · Sports Medicine · doi:10.2165/00007256-200232120-00004 · Cited by 649
Self-citationPractical Guide to Measuring Physical Activity
Sylvia, L. G., Bernstein, E. E., Hubbard, J. L., Keating, L., & Anderson, E. J. (2014) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2013.09.018 · Cited by 637
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Comparison of Pedometer and Accelerometer Accuracy under Controlled Conditions
LE MASURIER, G. C., & TUDOR-LOCKE, C. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000064996.63632.10 · Cited by 360
Self-citationAccelerometer-Determined Steps per Day inUS Adults
TUDOR-LOCKE, C., JOHNSON, W. D., & KATZMARZYK, P. T. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318199885c · Cited by 355
Self-citationSpring-Levered versus Piezo-Electric Pedometer Accuracy in Overweight and Obese Adults
CROUTER, S. E., SCHNEIDER, P. L., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000181677.36658.a8 · Cited by 295
Activity-Monitor Accuracy in Measuring Step Number and Cadence in Community-Dwelling Older Adults
Grant, P. M., Dall, P. M., Mitchell, S. L., & Granat, M. H. (2008) · Journal of Aging and Physical Activity · doi:10.1123/japa.16.2.201 · Cited by 297
Dwyer, T., Pezic, A., Sun, C., Cochrane, J., Venn, A., Srikanth, V., Jones, G., Shook, R., Sui, X., Ortaglia, A., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0141274 · Cited by 239
Tully, M. A., McBride, C., Heron, L., & Hunter, R. F. (2014) · BMC Research Notes · doi:10.1186/1756-0500-7-952 · Cited by 172
Effect of Sarcopenia on Cardiovascular Disease Risk Factors in Obese Postmenopausal Women
Aubertin‐Leheudre, M., Lord, C., Goulet, É. D. B., Khalil, A., & Dionne, I. J. (2006) · Obesity · doi:10.1038/oby.2006.267 · Cited by 151
Activity Monitoring and Energy Expenditure in COPD Patients: A Validation Study
Patel, S. A., Benzo, R. P., Slivka, W. A., & Sciurba, F. C. (2007) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550701246658 · Cited by 144
Évaluation de la qualité des podomètres commerciaux
Tudor-Locke, C., Sisson, S. B., Lee, S. M., Craig, C. L., Plotnikoff, R. C., & Bauman, A. (2006) · Canadian Journal of Public Health · doi:10.1007/bf03405359 · Cited by 142
Self-citationComparison of two waist-mounted and two ankle-mounted electronic pedometers
Karabulut, M., Crouter, S. E., & Bassett, D. R. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0018-3 · Cited by 139
Measuring physical activity during pregnancy
Harrison, C. L., Thompson, R. G., Teede, H. J., & Lombard, C. B. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-19 · Cited by 139
Self-citationComparison of Pedometer and Accelerometer Measures of Physical Activity in Preschool Children
Cardon, G., & De Bourdeaudhuij, I. (2007) · Pediatric Exercise Science · doi:10.1123/pes.19.2.205 · Cited by 110
Normative Steps/Day Values for Older Adults: NHANES 2005-2006
Tudor-Locke, C., Schuna, J. M., Barreira, T. V., Mire, E. F., Broyles, S. T., Katzmarzyk, P. T., & Johnson, W. D. (2013) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glt116 · Cited by 110
Self-citationA Persuasive and Social mHealth Application for Physical Activity: A Usability and Feasibility Study
Al Ayubi, S. U., Parmanto, B., Branch, R., & Ding, D. (2014) · JMIR mHealth and uHealth · doi:10.2196/mhealth.2902 · Cited by 108
Pedometer reliability, validity and daily activity targets among 10- to 15-year-old boys
Jago, R., Watson, K., Baranowski, T., Zakeri, I., Yoo, S., Baranowski, J., & Conry, K. (2006) · Journal of Sports Sciences · doi:10.1080/02640410500141661 · Cited by 94
Furlanetto, K. C., Bisca, G. W., Oldemberg, N., Sant'Anna, T. J., Morakami, F. K., Camillo, C. A., Cavalheri, V., Hernandes, N. A., Probst, V. S., Ramos, E. M., et al. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2009.10.024 · Cited by 87
Phillips, S. M., & McAuley, E. (2013) · Cancer Epidemiology, Biomarkers & Prevention · doi:10.1158/1055-9965.epi-12-0983 · Cited by 63
Validity of 2 Devices for Measuring Steps Taken by Older Adults in Assisted-Living Facilities
Bergman, R. J., Bassett, D. R., & Klein, D. A. (2008) · Journal of Physical Activity and Health · doi:10.1123/jpah.5.s1.s166 · Cited by 62
Phillips, S. M., & McAuley, E. (2014) · Psycho-Oncology · doi:10.1002/pon.3366 · Cited by 60
The bit doesn’t fit: Evaluation of a commercial activity-tracker at slower walking speeds
Wong, C. K., Mentis, H. M., & Kuber, R. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2017.10.010 · Cited by 46
Effects of Body Mass Index and Step Rate on Pedometer Error in a Free-Living Environment
TYO, B. M., FITZHUGH, E. C., BASSETT, D. R., JOHN, D., FEITO, Y., & THOMPSON, D. L. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e9b133 · Cited by 46
Metadata
- Authors
- TUDOR-LOCKE, C., AINSWORTH, B. E., THOMPSON, R. W., & MATTHEWS, C. E.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2002-12
- Volume
- 34
- Issue
- 12
- Pages
- 2045-2051
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2063323404
- Cited by
- 386
- References
- 5
- FWCI
- 6.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.