Considerations for safety in the use of extracranial stimulation for motor evoked potentials
The DOI matches its Crossref record.
Abstract
The possibility of neural damage during extracranial brain stimulation for motor evoked potentials (MEPs) is discussed from the perspective of animal studies in which the stimulating electrodes were in direct contact with the brain. These data indicate that the charge per phase used in most of the extracranial MEP protocols is sufficient to induce neural damage if the stimulation is applied continuously for several hours. However, in most cases dispersion of the stimulus current in the extracranial tissue and skull is probably adequate to attenuate the stimulus charge density at the brain surface to a safe level (less than approximately 40 microC/cm2 X ph). However, the possibility exists that low resistance paths between the stimulating electrode and the brain may give rise to foci of high charge density. The possibility of such focusing may be less with magnetic field than with direct electrical field stimulation. We stress the need for additional animal studies designed to delineate a range of safe stimulus parameters for this particular technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656
Transcranial direct current stimulation: State of the art 2008
Nitsche, M. A., Cohen, L. G., Wassermann, E. M., Priori, A., Lang, N., Antal, A., Paulus, W., Hummel, F., Boggio, P. S., Fregni, F., et al. (2008) · Brain Stimulation · doi:10.1016/j.brs.2008.06.004 · Cited by 3,057
“Conventional electrical brain stimulation can cause excitotoxic damage to overdriven neurons.(46) This is not applicable to tDCS for the following reasons: (1) The effects of tDCS inducing changes in cortical excitability are most probably caused by a mild effect on cation channels and not being able to induce firing…”
BackgroundRossini, P. M., Barker, A. T., Berardelli, A., Caramia, M. D., Caruso, G., Cracco, R. Q., Dimitrijević, M. R., Hallett, M., Katayama, Y., Lücking, C. H., et al. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90029-9 · Cited by 3,030
Sustained excitability elevations induced by transcranial DC motor cortex stimulation in humans
Nitsche, M. A., & Paulus, W. (2001) · Neurology · doi:10.1212/wnl.57.10.1899 · Cited by 2,617
Wassermann, E. M. (1998) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/s0168-5597(97)00096-8 · Cited by 2,293
Physiological basis of transcranial direct current stimulation
Stagg, C. J., & Nitsche, M. A. (2011) · The Neuroscientist · doi:10.1177/1073858410386614 · Cited by 1,719
“Although a number of safety limits were defined for direct electrical stimulation of the cortex in humans (Agnew and McCreery 1987), it is not clear how these relate to tDCS, which does not involve direct contact between the electrodes and the cortex.”
BackgroundA technical guide to tDCS, and related non-invasive brain stimulation tools
Woods, A. J., Antal, A., Bikson, M., Boggio, P. S., Brunoni, A. R., Celnik, P., Cohen, L. G., Fregni, F., Herrmann, C. S., Kappenman, E. S., et al. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.11.012 · Cited by 1,439
Brunoni, A. R., Amadera, J., Berbel, B., Volz, M. S., Rizzerio, B. G., & Fregni, F. (2011) · International Journal of Neuropsychopharmacology · doi:10.1017/s1461145710001690 · Cited by 1,234
Shaping the Effects of Transcranial Direct Current Stimulation of the Human Motor Cortex
Nitsche, M. A., Doemkes, S., Karaköse, T., Antal, A., Liebetanz, D., Lang, N., Tergau, F., & Paulus, W. (2007) · Journal of Neurophysiology · doi:10.1152/jn.01312.2006 · Cited by 738
Direct effects of transcranial electric stimulation on brain circuits in rats and humans
Vöröslakos, M., Takeuchi, Y., Brinyiczki, K., Zombori, T., Oliva, A., Fernández-Ruiz, A., Kozák, G., Kincses, Z. T., Iványi, B., Buzsáki, G., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-02928-3 · Cited by 735
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Self-citationSafety criteria for transcranial direct current stimulation (tDCS) in humans
Nitsche, M. A., Liebetanz, D., Lang, N., Antal, A., Tergau, F., & Paulus, W. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00235-9 · Cited by 697
Stimulation of the human motor cortex through the scalp
Rothwell, J., Thompson, P., Day, B., Boyd, S., & Marsden, C. (1991) · Experimental Physiology · doi:10.1113/expphysiol.1991.sp003485 · Cited by 664
Nitsche, M. A., Liebetanz, D., Antal, A., Lang, N., Tergau, F., & Paulus, W. (2003) · Supplements to Clinical Neurophysiology · doi:10.1016/s1567-424x(09)70230-2 · Cited by 601
Modification of Cortical Stimulation for Motor Evoked Potentials under General Anesthesia
Taniguchi, M., Cedzich, C., Taniguchi, M., Cedzich, C., & Schramm, J. (1993) · Neurosurgery · doi:10.1227/00006123-199302000-00011 · Cited by 554
Priori, A. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00437-6 · Cited by 508
Peterchev, A. V., Wagner, T. A., Miranda, P. C., Nitsche, M. A., Paulus, W., Lisanby, S. H., Pascual-Leone, A., & Bikson, M. (2012) · Brain Stimulation · doi:10.1016/j.brs.2011.10.001 · Cited by 429
Safety limits of cathodal transcranial direct current stimulation in rats
Liebetanz, D., Koch, R., Mayenfels, S., König, F., Paulus, W., & Nitsche, M. A. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.01.022 · Cited by 401
Szelényi, A., Bello, L., Duffau, H., Fava, E., Feigl, G. C., Galanda, M., Neuloh, G., Signorelli, F., & Sala, F. (2010) · Neurosurgical Focus · doi:10.3171/2009.12.focus09237 · Cited by 368
Cedzich, C., Taniguchi, M., Schäfer, S., & Schramm, J. (1996) · Neurosurgery · doi:10.1097/00006123-199605000-00023 · Cited by 344
Safety of Intraoperative Transcranial Electrical Stimulation Motor Evoked Potential Monitoring
MacDonald, D. B. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200210000-00005 · Cited by 342
Coil design considerations for deep transcranial magnetic stimulation
Deng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.11.038 · Cited by 308
Establishing safety limits for transcranial direct current stimulation
Bikson, M., Datta, A., & Elwassif, M. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.03.018 · Cited by 298
Antal, A., Terney, D., Poreisz, C., & Paulus, W. (2007) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2007.05896.x · Cited by 293
Velasco, M., Velasco, F., Velasco, A. L., Boleaga, B., Jimenez, F., Brito, F., & Marquez, I. (2000) · Epilepsia · doi:10.1111/j.1528-1157.2000.tb00135.x · Cited by 290
Animal models of transcranial direct current stimulation: Methods and mechanisms
Jackson, M. P., Rahman, A., Lafon, B., Kronberg, G., Ling, D., Parra, L. C., & Bikson, M. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2016.08.016 · Cited by 289
Minhas, P., Bansal, V., Patel, J., Ho, J. S., Diaz, J., Datta, A., & Bikson, M. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.05.007 · Cited by 267
Pechstein, U., Ceclzich, C., Nadstawek, J., & Schramm, J. (1996) · Neurosurgery · doi:10.1097/00006123-199608000-00020 · Cited by 246
Höflich, G., Kasper, S., Hufnagel, A., Ruhrmann, S., & Möller, H. ‐. (1993) · Human Psychopharmacology: Clinical and Experimental · doi:10.1002/hup.470080510 · Cited by 245
Baudewig, J., Nitsche, M. A., Paulus, W., & Frahm, J. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200102)45:2<196::aid-mrm1026>3.0.co;2-1 · Cited by 238
“The intensity and duration of the direct current used in these human tDCS applications were 1 mA and 5 min, i.e., within the safety range for electric stimulation ( 16 ) and below the values tested in animals.”
BackgroundParameters for direct cortical electrical stimulation in the human: histopathologic confirmation
Gordon, B., Lesser, R. P., Rance, N. E., Hart, J., Webber, R., Uematsu, S., & Fisher, R. S. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90082-u · Cited by 232
Electroconvulsive Therapy Stimulus Parameters: Rethinking Dosage
Peterchev, A. V., Rosa, M. A., Deng, Z.-D., Prudic, J., & Lisanby, S. H. (2010) · The Journal of ECT · doi:10.1097/yct.0b013e3181e48165 · Cited by 213
Duffau, H. (2007) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2007.09.003 · Cited by 196
Transcranial magnetic stimulation and epilepsy
Tassinari, C. A., Cincotta, M., Zaccara, G., & Michelucci, R. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00004-x · Cited by 192
Scheufler, K.-M., & Zentner, J. (2002) · Journal of Neurosurgery · doi:10.3171/jns.2002.96.3.0571 · Cited by 177
Peterchev, A. V., Jalinous, R., & Lisanby, S. H. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.900540 · Cited by 174
“The induced charge density, which is directly linked to tissue damage, is well below the recommended safety limit of 40 C/cm per pulse for all devices [20].”
BackgroundNezua, A., Kimura, S., Uehara, S., Kobayashia, T., Tanaka, M., & Saito, K. (1997) · Brain and Development · doi:10.1016/s0387-7604(96)00552-9 · Cited by 169
de Haan, P., Kalkman, C. J., de Mol, B. A., Ubags, L. H., Veldman, D. J., & Jacobs, M. J. H. M. (1997) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(97)70403-3 · Cited by 167
Comparison of neural damage induced by electrical stimulation with faradaic and capacitor electrodes
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. A. (1988) · Annals of Biomedical Engineering · doi:10.1007/bf02368010 · Cited by 163
“occurrence of neural damage at relatively low charge densities, using charge balanced stimulation, suggests that in many systems, other processes may contribute most of the damage (1,17,24,31).”
BackgroundSelf-citation
Metadata
- Authors
- Agnew, W. F., & McCreery, D. B.
- Venue
- Neurosurgery
- Published
- 1987-01
- Volume
- 20
- Issue
- 1
- Pages
- 143???7
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W2071198693
- Cited by
- 265
- References
- 0
- FWCI
- 12.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.