Effect of Microneedle Design on Pain in Human Volunteers
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To design microneedles that minimize pain, this study tested the hypothesis that microneedles cause significantly less pain than a 26-gauge hypodermic needle, and that decreasing microneedle length and the number of microneedles reduces pain in normal human volunteers. METHODS: Single microneedles with lengths ranging from 480 to 1450 microm, widths from 160 to 465 microm, thicknesses from 30 to 100 microm, and tip angles from 20 to 90 degrees; and arrays containing 5 or 50 microneedles were inserted into the volar forearms of 10 healthy, human volunteers in a double-blinded, randomized study. Visual analog scale pain scores were recorded and compared with each other and to the pain from a 26-gauge hypodermic needle. RESULTS: All microneedles investigated were significantly less painful than the hypodermic needle with microneedle pain scores varying from 5% to 40% of the hypodermic needle. Microneedle length had the strongest effect on pain, where a 3-fold increase in length increased the pain score by 7-fold. The number of microneedles also affected the pain score, where a 10-fold increase in the number of microneedles increased pain just over 2-fold. Microneedle tip angle, thickness, and width did not significantly influence pain. DISCUSSION: Microneedles are significantly less painful than a 26-gauge hypodermic needle over the range of dimensions investigated. Decreasing microneedle length and number of microneedles reduces pain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applied Linear Statistical Models
Ziegel, E. R., Neter, J., Wasserman, W., & Kutner, M. (1992) · Technometrics · doi:10.2307/1269588 · Cited by 9,907
Applied Linear Statistical Models
(1997) · Technometrics · doi:10.1080/00401706.1997.10485141 · Cited by 7,185
(1994) · PsycEXTRA Dataset · doi:10.1037/e546992006-001 · Cited by 1,714
Microneedles for transdermal drug delivery
Prausnitz, M. R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.023 · Cited by 1,521
Self-citationCurrent status and future potential of transdermal drug delivery
Prausnitz, M. R., Mitragotri, S., & Langer, R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1304 · Cited by 1,462
Self-citationApplied Linear Statistical Models
Ziegel, E. R., Neter, J., Kutner, M., Nachtsheim, C., & Wasserman, W. (1997) · Technometrics · doi:10.2307/1271154 · Cited by 1,309
Biodegradable polymer microneedles: Fabrication, mechanics and transdermal drug delivery
Park, J.-H., Allen, M. G., & Prausnitz, M. R. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.02.002 · Cited by 1,026
Self-citationDavis, S. P., Landis, B. J., Adams, Z. H., Allen, M. G., & Prausnitz, M. R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.010 · Cited by 934
Self-citationMcAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859
Self-citationCoated microneedles for transdermal delivery
Gill, H. S., & Prausnitz, M. R. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.10.017 · Cited by 765
Self-citation
Cited by
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Self-citationMicroneedles: A smart approach and increasing potential for transdermal drug delivery system
Waghule, T., Singhvi, G., Dubey, S. K., Pandey, M. M., Gupta, G., Singh, M., & Dua, K. (2019) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2018.10.078 · Cited by 1,260
Alkilani, A., McCrudden, M. T., & Donnelly, R. (2015) · Pharmaceutics · doi:10.3390/pharmaceutics7040438 · Cited by 1,147
Dissolving polymer microneedle patches for influenza vaccination
Sullivan, S. P., Koutsonanos, D. G., del Pilar Martin, M., Lee, J. W., Zarnitsyn, V., Choi, S.-O., Murthy, N., Compans, R. W., Skountzou, I., & Prausnitz, M. R. (2010) · Nature Medicine · doi:10.1038/nm.2182 · Cited by 948
Self-citationNon-invasive delivery strategies for biologics
Anselmo, A. C., Gokarn, Y., & Mitragotri, S. (2019) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2018.183 · Cited by 665
Rapidly separable microneedle patch for the sustained release of a contraceptive
Li, W., Terry, R. N., Tang, J., Feng, M. R., Schwendeman, S. P., & Prausnitz, M. R. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0337-4 · Cited by 492
Self-citationMicroneedle, bio-microneedle and bio-inspired microneedle: A review
Ma, G., & Wu, C. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.02.011 · Cited by 477
Micro-scale devices for transdermal drug delivery
Arora, A., Prausnitz, M. R., & Mitragotri, S. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2008.08.032 · Cited by 464
Self-citationMakvandi, P., Kirkby, M., Hutton, A. R. J., Shabani, M., Yiu, C. K. Y., Baghbantaraghdari, Z., Jamaledin, R., Carlotti, M., Mazzolai, B., Mattoli, V., et al. (2021) · Nano-Micro Letters · doi:10.1007/s40820-021-00611-9 · Cited by 455
Microneedles: an emerging transdermal drug delivery system
Bariya, S. H., Gohel, M. C., Mehta, T. A., & Sharma, O. P. (2012) · Journal of Pharmacy and Pharmacology · doi:10.1111/j.2042-7158.2011.01369.x · Cited by 455
Engineering Microneedle Patches for Vaccination and Drug Delivery to Skin
Prausnitz, M. R. (2017) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-060816-101514 · Cited by 439
Self-citationHydrogel‐Forming Microneedles: Current Advancements and Future Trends
Turner, J. G., White, L. R., Estrela, P., & Leese, H. S. (2021) · Macromolecular Bioscience · doi:10.1002/mabi.202000307 · Cited by 413
Current advances in the fabrication of microneedles for transdermal delivery
Indermun, S., Luttge, R., Choonara, Y. E., Kumar, P., du Toit, L. C., Modi, G., & Pillay, V. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.04.052 · Cited by 399
Sampling interstitial fluid from human skin using a microneedle patch
Samant, P. P., Niedzwiecki, M. M., Raviele, N., Tran, V., Mena-Lapaix, J., Walker, D. I., Felner, E. I., Jones, D. P., Miller, G. W., & Prausnitz, M. R. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aaw0285 · Cited by 379
Self-citationOpportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 360
Biodegradable 3D printed polymer microneedles for transdermal drug delivery
Luzuriaga, M. A., Berry, D. R., Reagan, J. C., Smaldone, R. A., & Gassensmith, J. J. (2018) · Lab on a Chip · doi:10.1039/c8lc00098k · Cited by 356
Kinetics of skin resealing after insertion of microneedles in human subjects
Gupta, J., Gill, H. S., Andrews, S. N., & Prausnitz, M. R. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.05.021 · Cited by 342
Self-citationDroplet-born air blowing: Novel dissolving microneedle fabrication
Kim, J. D., Kim, M., Yang, H., Lee, K., & Jung, H. (2013) · Journal of Controlled Release · doi:10.1016/j.jconrel.2013.05.026 · Cited by 326
Prausnitz, M. R., Mikszta, J. A., Cormier, M., & Andrianov, A. K. (2009) · Current Topics in Microbiology and Immunology · doi:10.1007/978-3-540-92165-3_18 · Cited by 314
Self-citationLiu, S., Jin, M.-N., Quan, Y.-S., Kamiyama, F., Katsumi, H., Sakane, T., & Yamamoto, A. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.05.030 · Cited by 310
Topical and Transdermal Drug Delivery: From Simple Potions to Smart Technologies
Benson, H. A. E., Grice, J. E., Mohammed, Y., Namjoshi, S., & Roberts, M. S. (2019) · Current Drug Delivery · doi:10.2174/1567201816666190201143457 · Cited by 303
Dissolving Microneedle Patch for Transdermal Delivery of Human Growth Hormone
Lee, J. W., Choi, S., Felner, E. I., & Prausnitz, M. R. (2011) · Small · doi:10.1002/smll.201001091 · Cited by 301
Self-citationBiodegradable Gelatin Methacryloyl Microneedles for Transdermal Drug Delivery
Luo, Z., Sun, W., Fang, J., Lee, K., Li, S., Gu, Z., Dokmeci, M. R., & Khademhosseini, A. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801054 · Cited by 294
Ling, M.-H., & Chen, M.-C. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.06.029 · Cited by 280
Lyu, S., Dong, Z., Xu, X., Bei, H.-P., Yuen, H.-Y., James Cheung, C.-W., Wong, M.-S., He, Y., & Zhao, X. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2023.04.003 · Cited by 266
Johnson, A. R., Caudill, C. L., Tumbleston, J. R., Bloomquist, C. J., Moga, K. A., Ermoshkin, A., Shirvanyants, D., Mecham, S. J., Luft, J. C., & DeSimone, J. M. (2016) · PLOS ONE · doi:10.1371/journal.pone.0162518 · Cited by 264
Chitosan Microneedle Patches for Sustained Transdermal Delivery of Macromolecules
Chen, M.-C., Ling, M.-H., Lai, K.-Y., & Pramudityo, E. (2012) · Biomacromolecules · doi:10.1021/bm301293d · Cited by 259
Chu, L. Y., Choi, S.-O., & Prausnitz, M. R. (2010) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22140 · Cited by 259
Self-citationKim, Y.-C., Quan, F.-S., Compans, R. W., Kang, S.-M., & Prausnitz, M. R. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.10.013 · Cited by 255
Self-citationMicroneedle-Based Delivery: An Overview of Current Applications and Trends
Guillot, A. J., Cordeiro, A. S., Donnelly, R. F., Montesinos, M. C., Garrigues, T. M., & Melero, A. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12060569 · Cited by 254
An overview of microneedle applications, materials, and fabrication methods
Faraji Rad, Z., Prewett, P. D., & Davies, G. J. (2021) · Beilstein Journal of Nanotechnology · doi:10.3762/bjnano.12.77 · Cited by 254
Arya, J., Henry, S., Kalluri, H., McAllister, D. V., Pewin, W. P., & Prausnitz, M. R. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.02.040 · Cited by 237
Self-citationMicroneedles: Characteristics, Materials, Production Methods and Commercial Development
Tucak, A., Sirbubalo, M., Hindija, L., Rahić, O., Hadžiabdić, J., Muhamedagić, K., Čekić, A., & Vranić, E. (2020) · Micromachines · doi:10.3390/mi11110961 · Cited by 231
“Metal MNs can be manufactured by 3D laser cutting [22,25,51,72,93,94], laser ablation [95–97], and electroplating or electroless plating of metal onto positive or negative MN molds [31].”
InfluentialSeparable arrowhead microneedles
Chu, L. Y., & Prausnitz, M. R. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.10.033 · Cited by 221
“, similar to metal microneedles used in other studies [12,13,15,22].”
BackgroundResultSelf-citationFabrication of coated polymer microneedles for transdermal drug delivery
Chen, Y., Chen, B. Z., Wang, Q. L., Jin, X., & Guo, X. D. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.03.383 · Cited by 219
Microneedle-based device for the one-step painless collection of capillary blood samples
Blicharz, T. M., Gong, P., Bunner, B. M., Chu, L. L., Leonard, K. M., Wakefield, J. A., Williams, R. E., Dadgar, M., Tagliabue, C. A., El Khaja, R., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0194-1 · Cited by 216
Design Principles of Ionic Liquids for Transdermal Drug Delivery
Tanner, E. E. L., Curreri, A. M., Balkaran, J. P. R., Selig‐Wober, N. C., Yang, A. B., Kendig, C., Fluhr, M. P., Kim, N., & Mitragotri, S. (2019) · Advanced Materials · doi:10.1002/adma.201901103 · Cited by 196
3D printing: An appealing route for customized drug delivery systems
Elkasabgy, N. A., Mahmoud, A. A., & Maged, A. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.119732 · Cited by 177
Design, Development, and Evaluation of a Novel Microneedle Array-based Continuous Glucose Monitor
Jina, A., Tierney, M. J., Tamada, J. A., McGill, S., Desai, S., Chua, B., Chang, A., & Christiansen, M. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814526191 · Cited by 176
“Microneedles, and specifically microneedle arrays, provide the ability to sample biological fluid with less pain provided that the needles do not penetrate the skin to the depth of the dermis where capillaries and most nerve endings reside.(14) By not penetrating to this depth, the biological fluid sampled is not bloo…”
BackgroundCaffarel-Salvador, E., Brady, A. J., Eltayib, E., Meng, T., Alonso-Vicente, A., Gonzalez-Vazquez, P., Torrisi, B. M., Vicente-Perez, E. M., Mooney, K., Jones, D. S., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0145644 · Cited by 174
“In contrast with conventional blood sampling, MN allow pain-free detection of drug molecules without stimulating the dermal nerves or causing bleeding [5–7].”
BackgroundZhang, Y., Jiang, G., Yu, W., Liu, D., & Xu, B. (2018) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.12.006 · Cited by 173
A self-adherent, bullet-shaped microneedle patch for controlled transdermal delivery of insulin
Seong, K.-Y., Seo, M.-S., Hwang, D. Y., O'Cearbhaill, E. D., Sreenan, S., Karp, J. M., & Yang, S. Y. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.03.041 · Cited by 170
Liu, S., Jin, M.-N., Quan, Y.-S., Kamiyama, F., Kusamori, K., Katsumi, H., Sakane, T., & Yamamoto, A. (2014) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2013.10.001 · Cited by 163
Biosensing in dermal interstitial fluid using microneedle based electrochemical devices
Madden, J., O'Mahony, C., Thompson, M., O'Riordan, A., & Galvin, P. (2020) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2020.100348 · Cited by 161
Rapidly dissolving fibroin microneedles for transdermal drug delivery
You, X., Chang, J.-H., Ju, B.-K., & Pak, J. J. (2011) · Materials Science and Engineering: C · doi:10.1016/j.msec.2011.06.010 · Cited by 58
Metadata
- Authors
- Gill, H. S., Denson, D. D., Burris, B. A., & Prausnitz, M. R.
- Venue
- The Clinical Journal of Pain
- Published
- 2008-09
- Volume
- 24
- Issue
- 7
- Pages
- 585-594
- ISSN
- 0749-8047 (ISSN-L)
- OpenAlex
- W2409984077
- Cited by
- 701
- References
- 29
- FWCI
- 14.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.