Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin®
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Background: If invasive measurement of arterial blood pressure is not warranted, finger cuff technology can provide continuous and noninvasive monitoring. Finger and radial artery pressures differ; Nexfin® (BMEYE, Amsterdam, The Netherlands) measures finger arterial pressure and uses physiologic reconstruction methodologies to obtain values comparable to invasive pressures. Methods: Intra-arterial pressure (IAP) and noninvasive Nexfin arterial pressure (NAP) were measured in cardiothoracic surgery patients, because invasive pressures are available. NAP-IAP differences were analyzed during 30 min. Tracking was quantified by within-subject precision (SD of individual NAP-IAP differences) and correlation coefficients. The ranges of pressure change were quantified by within-subject variability (SD of individual averages of NAP and IAP). Accuracy and precision were expressed as group average ± SD of the differences and considered acceptable when smaller than 5 ± 8 mmHg, the Association for the Advancement of Medical Instrumentation criteria. Results: NAP and IAP were obtained in 50 (34-83 yr, 40 men) patients. For systolic, diastolic, mean arterial, and pulse pressure, median (25-75 percentiles) correlation coefficients were 0.96 (0.91-0.98), 0.93 (0.87-0.96), 0.96 (0.90-0.97), and 0.94 (0.85-0.98), respectively. Within-subject precisions were 4 ± 2, 3 ± 1, 3 ± 2, and 3 ± 2 mmHg, and within-subject variations 13 ± 6, 6 ± 3, 9 ± 4, and 7 ± 4 mmHg, indicating precision over a wide range of pressures. Group average ± SD of the NAP-IAP differences were -1 ± 7, 3 ± 6, 2 ± 6, and -3 ± 4 mmHg, meeting criteria. Differences were not related to mean arterial pressure or heart rate. Conclusion: Arterial blood pressure can be measured noninvasively and continuously using physiologic pressure reconstruction. Changes in pressure can be followed and values are comparable to invasive monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Agreement Between Methods of Measurement with Multiple Observations Per Individual
Bland, J. M., & Altman, D. G. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701329422 · Cited by 2,065 · cited 1×
“Work of Bland and Altman includes a method for calculating the confidence of the limits of agreement with multiple measurements per individual but did not focus on simultaneously displaying both individual and group statistics.(33) Thus, each patient contributed one point with horizontal and vertical error bars (fig.”
MethodFifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 834
Analog studies of the human systemic arterial tree
Westerhof, N., Bosman, F., De Vries, C. J., & Noordergraaf, A. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90024-4 · Cited by 684 · cited 1×
“The tube system was divided into seven segments, with length, radius, and wall thickness based on biologic data.(29) Wave propagation and damping followed directly from longitudinal impedance based on Womersley’s theory and from transverse impedance that is based on the (viscoelastic) wall properties.”
MethodDirect Blood Pressure Measurement —Dynamic Response Requirements
Gardner, R. M. (1981) · Anesthesiology · doi:10.1097/00000542-198103000-00010 · Cited by 518
Non‐invasive pulsatile arterial pressure and stroke volume changes from the human finger
Bogert, L. W. J., & van Lieshout, J. J. (2005) · Experimental Physiology · doi:10.1113/expphysiol.2005.030262 · Cited by 413
Self-citationReconstruction of Brachial Artery Pressure From Noninvasive Finger Pressure Measurements
Bos, W. J. W., van Goudoever, J., van Montfrans, G. A., van den Meiracker, A. H., & Wesseling, K. H. (1996) · Circulation · doi:10.1161/01.cir.94.8.1870 · Cited by 365
Self-citationImholz, B. P. M., Settels, J. J., van der Meiracker, A. H., Wesseling, K. H., & Wieling, W. (1990) · Cardiovascular Research · doi:10.1093/cvr/24.3.214 · Cited by 344
Impaired Cerebral Autoregulation in Patients With Malignant Hypertension
Immink, R. V., van den Born, B.-J. H., van Montfrans, G. A., Koopmans, R. P., Karemaker, J. M., & van Lieshout, J. J. (2004) · Circulation · doi:10.1161/01.cir.0000144472.08647.40 · Cited by 243
Self-citationPhysiocal, calibrating finger vascular physiology for finapres
Wesseling, K. H., Wit, B. D., van der Hoeven, G. M. A., Goudoever, J. V., & Settels, J. J. (1995) · TU/e Research Portal · Cited by 229
Nexfin Noninvasive Continuous Blood Pressure Validated Against Riva-Rocci/Korotkoff
Eeftinck Schattenkerk, D. W., van Lieshout, J. J., van den Meiracker, A. H., Wesseling, K. R., Blanc, S., Wieling, W., van Montfrans, G. A., Settels, J. J., Wesseling, K. H., & Westerhof, B. E. (2009) · American Journal of Hypertension · doi:10.1038/ajh.2008.368 · Cited by 222
Self-citationValidation of brachial artery pressure reconstruction from finger arterial pressure
Guelen, I., Westerhof, B. E., van der Sar, G. L., van Montfrans, G. A., Kiemeneij, F., Wesseling, K. H., & Bos, W. J. W. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282fe1d28 · Cited by 186
Self-citationInvasive and Concomitant Noninvasive Intraoperative Blood Pressure Monitoring
Wax, D. B., Lin, H.-M., & Leibowitz, A. B. (2011) · Anesthesiology · doi:10.1097/aln.0b013e3182330286 · Cited by 178
Arterial viscoelasticity: A generalized model
Westerhof, N., & Noordergraaf, A. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90036-9 · Cited by 171
Bur, A., Hirschl, M. M., Herkner, H., Oschatz, E., Kofler, J., Woisetschläger, C., & Laggner, A. N. (2000) · Critical Care Medicine · doi:10.1097/00003246-200002000-00014 · Cited by 154
Models of brachial to finger pulse wave distortion and pressure decrement
Gizdulich, P., Prentza, A., & Wesseling, K. H. (1997) · Cardiovascular Research · doi:10.1016/s0008-6363(97)00003-5 · Cited by 147
Bur, A., Herkner, H., Vlcek, M., Woisetschläger, C., Derhaschnig, U., Delle Karth, G., Laggner, A. N., & Hirschl, M. M. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000053650.12025.1a · Cited by 123
Jellema, W. T., Imholz, B. P. M., Van Goudoever, J., Wesseling, K. H., & Van Lieshout, J. J. (1996) · Clinical Science · doi:10.1042/cs0910193 · Cited by 121
Self-citationStover, J., Stocker, R. A., Lenherr, R., Neff, T. A., Cottini, S. R., Zoller, B., & Béchir, M. (2009) · BMC Anesthesiology · doi:10.1186/1471-2253-9-6 · Cited by 112
Bos, W. J. W., Imholz, B. P. M., van Goudoever, J., Wesseling, K. H., & van Montfrans, G. A. (1992) · American Journal of Hypertension · doi:10.1093/ajh/5.8.529 · Cited by 102
Finapres tracking of systolic pressure and baroreflex sensitivity improved by waveform filtering
Gizdulich, P., Imholz, B. P. M., van den Meiracker, A. H., Parati, G., & Wesseling, K. H. (1996) · Journal of Hypertension · doi:10.1097/00004872-199602000-00014 · Cited by 93
Effects of graded vasoconstriction upon the measurement of finger arterial pressure
Imholz, B. P. M., Parati, G., Mancia, G., & Wesseling, K. H. (1992) · Journal of Hypertension · doi:10.1097/00004872-199209000-00010 · Cited by 72
The Accuracy of Finapres™ Noninvasive Mean Arterial Pressure Measurements in Anesthetized Patients
Gibbs, N. M., Larach, D. R., & Derr, J. A. (1991) · Anesthesiology · doi:10.1097/00000542-199104000-00004 · Cited by 61
Westerhof, B. E., Guelen, I., Stok, W. J., Lasance, H. A. J., Ascoop, C. A. P. L., Wesseling, K. H., Westerhof, N., Bos, W. J. W., Stergiopulos, N., & Spaan, J. A. E. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.91052.2008 · Cited by 60
Self-citationArterial pressure transfer characteristics: effects of travel time
Westerhof, B. E., Guelen, I., Stok, W. J., Wesseling, K. H., Spaan, J. A. E., Westerhof, N., Bos, W. J. W., & Stergiopulos, N. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00443.2006 · Cited by 56
Self-citationEffect of Regional and Systemic Changes in Vasomotor Tone on Finger Pressure Amplification
Bos, W. J. W., van den Meiracker, A. H., Wesseling, K. H., et al. (1995) · Hypertension · doi:10.1161/01.hyp.26.2.315 · Cited by 44
Reconstruction of brachial pressure from finger arterial pressure during orthostasis
Bogert, L. W. J., Harms, M. P. M., Pott, F. C., Secher, N. H., Wesseling, K. H., & LIESHOUT, J. J. V. (2004) · Journal of Hypertension · doi:10.1097/00004872-200410000-00008 · Cited by 33
Cited by
Kinsella, S. M., Carvalho, B., Dyer, R. A., Fernando, R., McDonnell, N., Mercier, F. J., Palanisamy, A., Sia, A. T. H., Van de Velde, M., Vercueil, A., et al. (2018) · Anaesthesia · doi:10.1111/anae.14080 · Cited by 585
Dort, J. C., Farwell, D. G., Findlay, M., Huber, G. F., Kerr, P., Shea-Budgell, M. A., Simon, C., Uppington, J., Zygun, D., Ljungqvist, O., et al. (2017) · JAMA Otolaryngology–Head & Neck Surgery · doi:10.1001/jamaoto.2016.2981 · Cited by 527
A Novel Continuous Blood Pressure Estimation Approach Based on Data Mining Techniques
Miao, F., Fu, N., Zhang, Y.-T., Ding, X.-R., Hong, X., He, Q., & Li, Y. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2691715 · Cited by 174
A Randomized Trial of Continuous Noninvasive Blood Pressure Monitoring During Noncardiac Surgery
Maheshwari, K., Khanna, S., Bajracharya, G. R., Makarova, N., Riter, Q., Raza, S., Cywinski, J. B., Argalious, M., Kurz, A., & Sessler, D. I. (2018) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000003482 · Cited by 173
Current Status and Prospects of Health-Related Sensing Technology in Wearable Devices
Cho, J. (2019) · Journal of Healthcare Engineering · doi:10.1155/2019/3924508 · Cited by 33
Metadata
- Authors
- Martina, J. R., Westerhof, B. E., van Goudoever, J., de Beaumont, E. M. F. H., Truijen, J., Kim, Y.-S., Immink, R. V., Jöbsis, D. A., Hollmann, M. W., Lahpor, J. R., de Mol, B. A. J. M., & van Lieshout, J. J.
- Venue
- Anesthesiology
- Published
- 2012-05-01
- Volume
- 116
- Issue
- 5
- Pages
- 1092-1103
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2028141385
- Cited by
- 292
- References
- 28
- FWCI
- 24.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.