The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature*
Abstract
OBJECTIVES: : A systematic review of the literature to determine the ability of dynamic changes in arterial waveform-derived variables to predict fluid responsiveness and compare these with static indices of fluid responsiveness. The assessment of a patient's intravascular volume is one of the most difficult tasks in critical care medicine. Conventional static hemodynamic variables have proven unreliable as predictors of volume responsiveness. Dynamic changes in systolic pressure, pulse pressure, and stroke volume in patients undergoing mechanical ventilation have emerged as useful techniques to assess volume responsiveness. DATA SOURCES: : MEDLINE, EMBASE, Cochrane Register of Controlled Trials and citation review of relevant primary and review articles. STUDY SELECTION: : Clinical studies that evaluated the association between stroke volume variation, pulse pressure variation, and/or stroke volume variation and the change in stroke volume/cardiac index after a fluid or positive end-expiratory pressure challenge. DATA EXTRACTION AND SYNTHESIS: : Data were abstracted on study design, study size, study setting, patient population, and the correlation coefficient and/or receiver operating characteristic between the baseline systolic pressure variation, stroke volume variation, and/or pulse pressure variation and the change in stroke index/cardiac index after a fluid challenge. When reported, the receiver operating characteristic of the central venous pressure, global end-diastolic volume index, and left ventricular end-diastolic area index were also recorded. Meta-analytic techniques were used to summarize the data. Twenty-nine studies (which enrolled 685 patients) met our inclusion criteria. Overall, 56% of patients responded to a fluid challenge. The pooled correlation coefficients between the baseline pulse pressure variation, stroke volume variation, systolic pressure variation, and the change in stroke/cardiac index were 0.78, 0.72, and 0.72, respectively. The area under the receiver operating characteristic curves were 0.94, 0.84, and 0.86, respectively, compared with 0.55 for the central venous pressure, 0.56 for the global end-diastolic volume index, and 0.64 for the left ventricular end-diastolic area index. The mean threshold values were 12.5 +/- 1.6% for the pulse pressure variation and 11.6 +/- 1.9% for the stroke volume variation. The sensitivity, specificity, and diagnostic odds ratio were 0.89, 0.88, and 59.86 for the pulse pressure variation and 0.82, 0.86, and 27.34 for the stroke volume variation, respectively. CONCLUSIONS: : Dynamic changes of arterial waveform-derived variables during mechanical ventilation are highly accurate in predicting volume responsiveness in critically ill patients with an accuracy greater than that of traditional static indices of volume responsiveness. This technique, however, is limited to patients who receive controlled ventilation and who are not breathing spontaneously.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743
Dellinger, R. P., Levy, M. M., Carlet, J. M., Bion, J., Parker, M. M., Jaeschke, R., Reinhart, K., Angus, D. C., Brun-Buisson, C., Beale, R., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-007-0934-2 · Cited by 6,772
Moher, D., Cook, D. J., Eastwood, S., Olkin, I., Rennie, D., & Stroup, D. F. (1999) · The Lancet · doi:10.1016/s0140-6736(99)04149-5 · Cited by 4,826
Comparison of Two Fluid-Management Strategies in Acute Lung Injury
(2006) · New England Journal of Medicine · doi:10.1056/nejmoa062200 · Cited by 3,538
Sepsis in European intensive care units: Results of the SOAP study*
Vincent, J.-L., Sakr, Y., Sprung, C. L., Ranieri, V. M., Reinhart, K., Gerlach, H., Moreno, R., Carlet, J., Le Gall, J.-R., & Payen, D. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000194725.48928.3a · Cited by 2,836
Brandstrup, B., Tønnesen, H., Beier-Holgersen, R., Hjortsø, E., Ørding, H., Lindorff-Larsen, K., Rasmussen, M. S., Lanng, C., Wallin, L., Iversen, L. H., et al. (2003) · Annals of Surgery · doi:10.1097/01.sla.0000094387.50865.23 · Cited by 1,585
Marik, P. E., Baram, M., & Vahid, B. (2008) · Chest · doi:10.1378/chest.07-2331 · Cited by 1,516
Self-citationMICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458
Predicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367
The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
Feissel, M., Michard, F., Faller, J.-P., & Teboul, J.-L. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2233-5 · Cited by 967
Barbier, C., Loubières, Y., Schmit, C., Hayon, J., Ricôme, J.-L., Jardin, F., & Vieillard-Baron, A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2259-8 · Cited by 940
Kumar, A., Anel, R., Bunnell, E., Habet, K., Zanotti, S., Marshall, S., Neumann, A., Ali, A., Cheang, M., Kavinsky, C., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000114996.68110.c9 · Cited by 800
Pulse pressure variations to predict fluid responsiveness: influence of tidal volume
De Backer, D., Heenen, S., Piagnerelli, M., Koch, M., & Vincent, J.-L. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2586-4 · Cited by 706
Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge*
Osman, D., Ridel, C., Ray, P., Monnet, X., Anguel, N., Richard, C., & Teboul, J.-L. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000249851.94101.4f · Cited by 695
Feissel, M., Michard, F., Mangin, I., Ruyer, O., Faller, J.-P., & Teboul, J.-L. (2001) · CHEST · doi:10.1378/chest.119.3.867 · Cited by 612
Systolic Pressure Variation as a Guide to Fluid Therapy in Patients with Sepsis-induced Hypotension
Tavernier, B., Makhotine, O., Lebuffe, G., Dupont, J., & Scherpereel, P. (1998) · Anesthesiology · doi:10.1097/00000542-199812000-00007 · Cited by 570
Vincent, J.-L., & Weil, M. H. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000214677.76535.a5 · Cited by 424
QUOROM Group, Moher, D., Cook, D. J., Eastwood, S., Olkin, I., Rennie, D., & Stroup, D. F. (2000) · Journal of British Surgery · doi:10.1046/j.1365-2168.2000.01610.x · Cited by 416
Stroke Volume Variation as a Predictor of Fluid Responsiveness in Patients Undergoing Brain Surgery
Berkenstadt, H., Margalit, N., Hadani, M., Friedman, Z., Segal, E., Villa, Y., & Perel, A. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200104000-00034 · Cited by 412
Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation.
Michard, F., & Teboul, J. (2000) · Critical Care · doi:10.1186/cc710 · Cited by 409
Cannesson, M. P., Desebbe, O., Rosamel, P., Delannoy, B., Robin, J., Bastien, O. H., & Lehot, J.-J. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen133 · Cited by 377
Reuter, D. A., Felbinger, T. W., Schmidt, C., et al. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1211-z · Cited by 375
MICHARD, F., CHEMLA, D., RICHARD, C., WYSOCKI, M., PINSKY, M. R., LECARPENTIER, Y., & TEBOUL, J.-L. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.3.9805077 · Cited by 371
Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patients
Feissel, M., Teboul, J., Merlani, P. G., Badie, J. C., Faller, J.-P., & Bendjelid, K. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0602-6 · Cited by 300
Reuter, D. A., Kirchner, A., Felbinger, T. W., Weis, F. C., Kilger, E., Lamm, P., & Goetz, A. E. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000059442.37548.e1 · Cited by 281
Hofer, C. K., Müller, S. M., Furrer, L., Klaghofer, R., Genoni, M., & Zollinger, A. (2005) · Chest · doi:10.1378/chest.128.2.848 · Cited by 279
Preisman, S., Kogan, S., Berkenstadt, H., & Perel, A. (2005) · British Journal of Anaesthesia · doi:10.1093/bja/aei262 · Cited by 269
Reuter, D. A., Bayerlein, J., Goepfert, M. S. G., Weis, F. C., Kilger, E., Lamm, P., & Goetz, A. E. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1649-7 · Cited by 265
Bedside Ultrasonography in the ICU
Beaulieu, Y., & Marik, P. E. (2005) · Chest · doi:10.1378/chest.128.2.881 · Cited by 233
Self-citationHofer, C. K., Senn, A., Weibel, L., & Zollinger, A. (2008) · Critical Care · doi:10.1186/cc6933 · Cited by 222
Cannesson, M., Attof, Y., Rosamel, P., Desebbe, O., Joseph, P., Metton, O., Bastien, O., & Lehot, J.-J. (2007) · Anesthesiology · doi:10.1097/01.anes.0000267593.72744.20 · Cited by 216
Schricker, T., & Carvalho, G. (2005) · Annals of Surgery · doi:10.1097/01.sla.0000149933.22895.96 · Cited by 201
Prediction of fluid responsiveness in patients during cardiac surgery
Rex, S., Brose, S., Metzelder, S., Hu¨neke, R., Scha¨lte, G., Autschbach, R., Rossaint, R., & Buhre, W. (2004) · British Journal of Anaesthesia · doi:10.1093/bja/aeh280 · Cited by 193
Pulse Pressure Variation Predicts Fluid Responsiveness Following Coronary Artery Bypass Surgery
Kramer, A., Zygun, D., Hawes, H., Easton, P., & Ferland, A. (2004) · Chest · doi:10.1378/chest.126.5.1563 · Cited by 192
Mintz, G. S., Kotler, M. N., Parry, W. R., Iskandrian, A. S., & Kane, S. A. (1981) · Circulation · doi:10.1161/01.cir.64.5.1018 · Cited by 181
Biais, M., Nouette-Gaulain, K., Cottenceau, V., Revel, P., & Sztark, F. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen277 · Cited by 180
Non-invasive prediction of fluid responsiveness during major hepatic surgery † ‡
Solus-Biguenet, H., Fleyfel, M., Tavernier, B., Kipnis, E., Onimus, J., Robin, E., Lebuffe, G., Decoene, C., Pruvot, F. R., & Vallet, B. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael250 · Cited by 169
Echocardiographic measurement of fluid responsiveness
Charron, C., Caille, V., Jardin, F., & Vieillard-Baron, A. (2006) · Current Opinion in Critical Care · doi:10.1097/01.ccx.0000224870.24324.cc · Cited by 167
Marx, G., Cope, T., McCrossan, L., Swaraj, S., Cowan, C., Mostafa, S. M., Wenstone, R., & Leuwer, M. (2004) · European Journal of Anaesthesiology · doi:10.1017/s0265021504002091 · Cited by 162
Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients
Wiesenack, C., Fiegl, C., Keyser, A., Prasser, C., & Keyl, C. (2005) · European Journal of Anaesthesiology · doi:10.1017/s0265021505001092 · Cited by 146
Huang, C.-C., Fu, J., Hu, H., Kao, K., Chen, N., Hsieh, M., & Tsai, Y. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e318186b74e · Cited by 143
Natalini, G., Rosanò, A., Taranto, M., Faggian, B., Vittorielli, E., & Bernardini, A. (2006) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000246811.88524.75 · Cited by 136
Reuter, D. A., Felbinger, T. W., Kilger, E., Schmidt, C., Lamm, P., & Goetz, A. E. (2002) · British Journal of Anaesthesia · doi:10.1093/bja/88.1.124 · Cited by 136
Online Monitoring of Pulse Pressure Variation to Guide Fluid Therapy After Cardiac Surgery
Júnior, J. O. C. A., Galas, F. R. B. G., Hajjar, L. A., dos Santos, L. O., Carvalho, T. F. G. D. L., & Michard, F. (2008) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000287664.03547.c6 · Cited by 127
Cannesson, M. P., Slieker, J. C., Desebbe, O., Bauer, C., Chiari, P. C., Hénaine, R., & Lehot, J. (2008) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000297291.01615.5c · Cited by 118
Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness
Lee, J.-H., Kim, J., Yoon, S., Lim, Y., Jeon, Y., Bahk, J.-H., & Kim, C. S. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem179 · Cited by 110
Pre-ejection period variations predict the fluid responsiveness of septic ventilated patients
Feissel, M., Badie, J. C., Merlani, P. G., et al. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000186415.43713.2f · Cited by 103
Perner, A., & Faber, T. (2006) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2006.01120.x · Cited by 98
Fluid-Management Strategies in Acute Lung Injury — Liberal, Conservative, or Both?
Rivers, E. P. (2006) · New England Journal of Medicine · doi:10.1056/nejme068105 · Cited by 94
Belloni, L., Pisano, A., Natale, A., Piccirillo, M. R., Piazza, L., Ismeno, G., & Martino, G. (2007) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2007.07.007 · Cited by 85
Wyffels, P., Durnez, P., Helderweirt, J., Stockman, W., & Kegel, D. D. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000267520.16003.17 · Cited by 80
Perel, A., Minkovich, L. L., Preisman, S., Abiad, M., Segal, E., & Coriat, P. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000146939.66172.ae · Cited by 72
Meta-analysis in Surgery: Methods and Limitations
Ng, T. T., McGory, M. L., Ko, C. Y., & Maggard, M. A. (2006) · Archives of Surgery · doi:10.1001/archsurg.141.11.1125 · Cited by 61
Change in stroke volume in response to fluid challenge: assessment using esophageal Doppler
Roeck, M., Jakob, S. M., Böhlen, T., Brander, L., Knuesel, R., & Takala, J. A. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1720-4 · Cited by 61
Cited by
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
The Surviving Sepsis Campaign Guidelines Committee including The Pediatric Subgroup*, Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2769-8 · Cited by 7,290
Nygren, J., Thacker, J., Carli, F., Fearon, K. C. H., Norderval, S., Lobo, D. N., Ljungqvist, O., Soop, M., & Ramirez, J. (2013) · World Journal of Surgery · doi:10.1007/s00268-012-1787-6 · Cited by 2,171
Vincent, J.-L., & De Backer, D. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1208943 · Cited by 1,425
Gustafsson, U. O., Scott, M. J., Schwenk, W., Demartines, N., Roulin, D., Francis, N., McNaught, C. E., MacFie, J., Liberman, A. S., Soop, M., et al. (2013) · World Journal of Surgery · doi:10.1007/s00268-012-1772-0 · Cited by 1,082
Metadata
- Authors
- Marik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A.
- Venue
- Critical Care Medicine
- Published
- 2009-09
- Volume
- 37
- Issue
- 9
- Pages
- 2642-2647
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2162516878
- Cited by
- 1,272
- References
- 54
- FWCI
- 10.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.