CoChat

Real-time continuous glucose monitoring

Buckingham, Bruce, Caswell, Kimberly, Wilson, Darrell M · 2007 · Current Opinion in Endocrinology, Diabetes & Obesity
Cited by 64

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

PURPOSE OF REVIEW: To summarize the current literature on real-time continuous glucose monitors, focusing on devices that have been approved or are pending approval. RECENT FINDINGS: Real-time continuous glucose sensors are new tools to assist in diabetes management. Several devices are currently being sold and additional monitors are expected to be available shortly. These sensors measure interstitial glucose - a distinct physiologic space when compared with the blood glucose. The ability to recognize trends in blood glucose levels provides a new paradigm for making insulin dose decisions and treating hypo- and hyperglycemia. SUMMARY: Real-time continuous glucose monitoring systems are currently less accurate than home glucose meters, but provide information every 1-5 min throughout the day and night with alarms for hyper- and hypoglycemia, providing information on glucose trends and nocturnal glycemic excursions. Current real-time sensors are behavior modification tools. Thus, improvements in diabetes control depend on the willingness of patients to modify their diabetes management based on information provided by these devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/med.0b013e32825a675e

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 21

  1. Khalil, 2004, Noninvasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium, Diabetes Technol Ther, 6, 660, 10.1089/dia.2004.6.660 · DOI · Paper page
  2. Garg, 2004, Improved glucose excursions using an implantable real-time continuous glucose sensor in adults with type 1 diabetes, Diabetes Care, 27, 734, 10.2337/diacare.27.3.734 · DOI · Paper page
  3. Armour, 1990, Application of chronic intravascular blood glucose sensor in dogs, Diabetes, 39, 1519, 10.2337/diab.39.12.1519 · DOI · Paper page
  4. Renard, 2002, From external to implantable insulin pump, can we close the loop?, Diabetes Metab, 28, 2S19
  5. Boyne, 2003, Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor, Diabetes, 52, 2790, 10.2337/diabetes.52.11.2790 · DOI · Paper page
  6. Nielsen, 2005, Continuous glucose monitoring in interstitial subcutaneous adipose tissue and skeletal muscle reflects excursions in cerebral cortex, Diabetes, 54, 1635, 10.2337/diabetes.54.6.1635 · DOI · Paper page
  7. Buckingham, 2006, Evaluation of factors affecting CGMS calibration, Diabetes Technol Ther, 8, 318, 10.1089/dia.2006.8.318 · DOI · Paper page
  8. Weinstein, 2007, Accuracy of the 5-day FreeStyle Navigator continuous glucose monitoring system: comparison with frequent laboratory reference measurements, Diabetes Care, 30, 1125, 10.2337/dc06-1602 · DOI · Paper page
  9. Bode, 2004, Alarms based on real-time sensor glucose values alert patients to hypo- and hyperglycemia: the guardian continuous monitoring system, Diabetes Technol Ther, 6, 105, 10.1089/152091504773731285 · DOI · Paper page
  10. Piper, 2006, Real-time continuous glucose monitoring in pediatric patients during and after cardiac surgery, Pediatrics, 118, 1176, 10.1542/peds.2006-0347 · DOI · Paper page
  11. Garg, 2006, Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial, Diabetes Care, 29, 44, 10.2337/diacare.29.01.06.dc05-1686 · DOI · Paper page
  12. Garg, 2006, Relationship of fasting and hourly blood glucose levels to HbA1c values: safety, accuracy, and improvements in glucose profiles obtained using a 7-day continuous glucose sensor, Diabetes Care, 29, 2644, 10.2337/dc06-1361 · DOI · Paper page
  13. Wilson, 2007, The accuracy of the FreeStyle Navigator continuous glucose monitoring system in children with type 1 diabetes, Diabetes Care, 30, 59, 10.2337/dc06-1407 · DOI · Paper page
  14. Tsalikian, 2004, GlucoWatch G2 Biographer alarm reliability during hypoglycemia in children, Diabetes Technol Ther, 6, 559, 10.1089/dia.2004.6.559 · DOI
  15. Chase, 2005, A randomized multicenter trial comparing the GlucoWatch Biographer with standard glucose monitoring in children with type 1 diabetes, Diabetes Care, 28, 1101, 10.2337/diacare.28.5.1101 · DOI · Paper page
  16. Halvorson, 2007, A pilot trial in pediatrics with the sensor-augmented pump: combining real-time continuous glucose monitoring with the insulin pump, J Pediatr, 150, 103, 10.1016/j.jpeds.2006.08.069 · DOI
  17. Mastrototaro, 2006, Clinical experience with an integrated continuous glucose sensor/insulin pump platform: a feasibility study, Adv Ther, 23, 725, 10.1007/BF02850312 · DOI
  18. 2005, Youth and parent satisfaction with clinical use of the GlucoWatch G2 Biographer in the management of pediatric type 1 diabetes., Diabetes Care, 28, 1929, 10.2337/diacare.28.8.1929 · DOI · Paper page
  19. Buckingham, 2005, Response to nocturnal alarms using a real-time glucose sensor, Diabetes Technol Ther, 7, 440, 10.1089/dia.2005.7.440 · DOI · Paper page
  20. Van den Berghe, 2001, Intensive insulin therapy in the critically ill patients, N Engl J Med, 345, 1359, 10.1056/NEJMoa011300 · DOI · Paper page
  21. Goldberg, 2004, Experience with the continuous glucose monitoring system in a medical intensive care unit, Diabetes Technol Ther, 6, 339, 10.1089/152091504774198034 · DOI · Paper page

Cited by

See all 64

Metadata

Authors
Buckingham, B., Caswell, K., & Wilson, D. M.
Venue
Current Opinion in Endocrinology, Diabetes & Obesity
Published
2007-08
Volume
14
Issue
4
Pages
288-295
ISSN
1752-296X (ISSN-L)
OpenAlex
W2044912944
Cited by
64
References
2
FWCI
6.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.