Metal Artifact Reduction by Dual-Energy Computed Tomography Using Energetic Extrapolation: A Systematically Optimized Protocol
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: Energetic extrapolation is a promising strategy to reduce metal artifacts in dual-source computed tomography (DSCT). We performed this study to systematically optimize image acquisition parameters for this approach in a hip phantom and assess its value in a clinical study. MATERIALS AND METHODS: Titanium and steel hip prostheses were placed in a standard hip phantom and a water tank and scanned on a DSCT scanner. Tube spectra, tube current ratio, collimation, pitch, and rotation time were optimized in a stepwise process. Artifacts were quantified by measuring the standard deviation of the computed tomography density in a doughnut-shaped region of interest placed around the prosthesis. A total of 22 adult individuals with metallic implants referred for computed tomography for a musculoskeletal indication were scanned using the optimized protocol. Degree of artifacts and diagnostic image quality were rated visually (0-10) and maximum streak intensity was measured. RESULTS: Sn140/100 kVp proved superior to Sn140/80 kVp. There was a benefit for increasing tube current ratio from 1:1 to 3:1, but not beyond, in favor of the Sn140 kVp spectrum. Artifacts were less severe for a collimation of 32 × 0.6 mm as compared with 40 × 0.6 mm. A pitch of 0.5 at a rotation time of 0.5 seconds per rotation was preferable to other combinations with comparable scanning times. In the clinical study, increasing the extrapolated photon energy from 64 to 120 keV decreased the severity of artifacts from 8.0 to 2.0 (P < 0.001) and decreased streak intensity from 871 to 153 HU (P < 0.001). The median diagnostic image quality rating improved from 2.5 to 8.0 (P < 0.001). The median energy level visually perceived as optimal for diagnostic evaluation was 113 keV (range, 100-130 keV). CONCLUSIONS: Sn140/100 kVp with a tube current ratio of 3:1, a collimation of 32 × 0.6 mm, and extrapolated energies of 105 to 120 keV are optimal parameters for a dedicated DSCT protocol that effectively reduces metal artifacts by energetic extrapolation. The protocol effectively reduces metal artifacts in all types of metal implants. The optimized reconstructions yielded relevant additional findings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Artifacts in CT: Recognition and Avoidance
Barrett, J. F., & Keat, N. (2004) · RadioGraphics · doi:10.1148/rg.246045065 · Cited by 1,688 · cited 2×
“The main mechanisms responsible for metal artifacts in CT are beam hardening and photon starvation.(2) However, other factors such as scatter and edge effects may further add to artifacts from metallic hardware.”
BackgroundMaterial differentiation by dual energy CT: initial experience
Johnson, T. R. C., Krauß, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D., Fink, C., Weckbach, S., Lenhard, M., Schmidt, B., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0517-6 · Cited by 1,510 · cited 1×
“Using a combination of 2 different spectra, dual-energy CT allows for the differentiation of matter based on their differential absorption properties at different spectra.(15,16) Dual-energy CT has emerged as a powerful technique in various clinical applications, including the differentiation of renal masses,(17,18) c…”
MethodSelf-citationMetal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
Bamberg, F., Dierks, A., Nikolaou, K., Reiser, M. F., Becker, C. R., & Johnson, T. R. C. (2011) · European Radiology · doi:10.1007/s00330-011-2062-1 · Cited by 537 · cited 2×
“The higher energies had been chosen empirically based on our observation that, in most cases, the optimal extrapolation energy is likely to fall in the 105 to 135 keV range.(27) For the single-energy images, only the B-detector images originating from the Sn140 kVp spectrum were reconstructed.”
BackgroundMethodSelf-citationLee, M.-J., Kim, S., Lee, S.-A., Song, H.-T., Huh, Y.-M., Kim, D.-H., Han, S. H., & Suh, J.-S. (2007) · RadioGraphics · doi:10.1148/rg.273065087 · Cited by 513
Dual Energy CT Characterization of Urinary Calculi: Initial In Vitro and Clinical Experience
Graser, A., Johnson, T. R. C., Bader, M., Staehler, M., Haseke, N., Nikolaou, K., Reiser, M. F., Stief, C. G., & Becker, C. R. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e318157a144 · Cited by 341
Self-citationKachelrieß, M., Watzke, O., & Kalender, W. A. (2001) · Medical Physics · doi:10.1118/1.1358303 · Cited by 311 · cited 1×
“Adaptive filtering algorithms have been introduced to reduce high directional image noise, thus decreasing photon starvation effects.(7) Most other approaches are based on filtered backprojection (FBP) and use varying strategies to correct affected raw data during FBP.”
BackgroundEvaluation of Two Iterative Techniques for Reducing Metal Artifacts in Computed Tomography
Boas, F. E., & Fleischmann, D. (2011) · Radiology · doi:10.1148/radiol.11101782 · Cited by 303 · cited 4×
“However, none of these techniques has gained widespread clinical acceptance, mainly because no single approach can eliminate all sources of artifacts and many interpolation techniques may cause new artifacts.(3,14) In addition, the clinical application of iterative methods is limited by the computational power of curr…”
BackgroundInfluentialAn iterative approach to the beam hardening correction in cone beam CT
Hsieh, J., Molthen, R. C., Dawson, C. A., & Johnson, R. H. (2000) · Medical Physics · doi:10.1118/1.598853 · Cited by 280 · cited 1×
“3Y5 Iterative beam-hardening correction can also reduce beam-hardening effects.(6) Adaptive filtering algorithms have been introduced to reduce high directional image noise, thus decreasing photon starvation effects.”
BackgroundMetal artifact reduction in CT using tissue-class modeling and adaptive prefiltering
Bal, M., & Spies, L. (2006) · Medical Physics · doi:10.1118/1.2218062 · Cited by 234
Mahnken, A. H., Raupach, R., Wildberger, J. E., Jung, B., Heussen, N., Flohr, T. G., Günther, R. W., & Schaller, S. (2003) · Investigative Radiology · doi:10.1097/01.rli.0000086495.96457.54 · Cited by 227
Cited by
Current and Novel Techniques for Metal Artifact Reduction at CT: Practical Guide for Radiologists
Katsura, M., Sato, J., Akahane, M., Kunimatsu, A., & Abe, O. (2018) · RadioGraphics · doi:10.1148/rg.2018170102 · Cited by 343
Metal Artifact Reduction in CT: Where Are We After Four Decades?
Gjesteby, L., De Man, B., Jin, Y., Paganetti, H., Verburg, J., Giantsoudi, D., & Wang, G. (2016) · IEEE Access · doi:10.1109/access.2016.2608621 · Cited by 290
Dual-Energy CT for the Musculoskeletal System
Mallinson, P. I., Coupal, T. M., McLaughlin, P. D., Nicolaou, S., Munk, P. L., & Ouellette, H. A. (2016) · Radiology · doi:10.1148/radiol.2016151109 · Cited by 242
Metadata
- Authors
- Meinel, F. G., Bischoff, B., Zhang, Q., Bamberg, F., Reiser, M. F., & Johnson, T. R. C.
- Venue
- Investigative Radiology
- Published
- 2012-07
- Volume
- 47
- Issue
- 7
- Pages
- 406-414
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2093244586
- Cited by
- 169
- References
- 18
- FWCI
- 6.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.