The DOI matches its Crossref record; 95 of the 95 references it cites were found in a registry or an index.
Biomedical photoacoustic imaging
Open accessAbstract
Photoacoustic (PA) imaging, also called optoacoustic imaging, is a new biomedical imaging modality based on the use of laser-generated ultrasound that has emerged over the last decade. It is a hybrid modality, combining the high-contrast and spectroscopic-based specificity of optical imaging with the high spatial resolution of ultrasound imaging. In essence, a PA image can be regarded as an ultrasound image in which the contrast depends not on the mechanical and elastic properties of the tissue, but its optical properties, specifically optical absorption. As a consequence, it offers greater specificity than conventional ultrasound imaging with the ability to detect haemoglobin, lipids, water and other light-absorbing chomophores, but with greater penetration depth than purely optical imaging modalities that rely on ballistic photons. As well as visualizing anatomical structures such as the microvasculature, it can also provide functional information in the form of blood oxygenation, blood flow and temperature. All of this can be achieved over a wide range of length scales from micrometres to centimetres with scalable spatial resolution. These attributes lend PA imaging to a wide variety of applications in clinical medicine, preclinical research and basic biology for studying cancer, cardiovascular disease, abnormalities of the microcirculation and other conditions. With the emergence of a variety of truly compelling in vivo images obtained by a number of groups around the world in the last 2–3 years, the technique has come of age and the promise of PA imaging is now beginning to be realized. Recent highlights include the demonstration of whole-body small-animal imaging, the first demonstrations of molecular imaging, the introduction of new microscopy modes and the first steps towards clinical breast imaging being taken as well as a myriad of in vivo preclinical imaging studies. In this article, the underlying physical principles of the technique, its practical implementation, and a range of clinical and preclinical applications are reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Constants of Water in the 200-nm to 200-μm Wavelength Region
Hale, G. M., & Querry, M. R. (1973) · Applied Optics · doi:10.1364/ao.12.000555 · Cited by 4,468
Photoacoustic imaging in biomedicine
Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700
Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
Wang, X., Pang, Y., Ku, G., Xie, X., Stoica, G., & Wang, L. V. (2003) · Nature Biotechnology · doi:10.1038/nbt839 · Cited by 1,700
Multiscale photoacoustic microscopy and computed tomography
Wang, L. V. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.157 · Cited by 1,400
Applications of photoacoustic sensing techniques
Tam, A. C. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.381 · Cited by 1,306
Carbon nanotubes as photoacoustic molecular imaging agents in living mice
De La Zerda, A., Zavaleta, C., Keren, S., Vaithilingam, S., Bodapati, S., Liu, Z., Levi, J., Smith, B. R., Ma, T.-J., Oralkan, O., et al. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.231 · Cited by 1,271
Universal back-projection algorithm for photoacoustic computed tomography
Xu, M., & Wang, L. V. (2005) · Physical Review E · doi:10.1103/physreve.71.016706 · Cited by 1,243
On the production and reproduction of sound by light
Bell, A. G. (1880) · American Journal of Science · doi:10.2475/ajs.s3-20.118.305 · Cited by 1,082
Wray, S., Cope, M., Delpy, D. T., Wyatt, J. S., & Reynolds, E. O. R. (1988) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/0005-2728(88)90069-2 · Cited by 912
Cited by
Thermo‐plasmonics: using metallic nanostructures as nano‐sources of heat
Baffou, G., & Quidant, R. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200003 · Cited by 1,392
Contrast agents for molecular photoacoustic imaging
Weber, J., Beard, P. C., & Bohndiek, S. E. (2016) · Nature Methods · doi:10.1038/nmeth.3929 · Cited by 1,270
Self-citationGold Nanomaterials at Work in Biomedicine
Yang, X., Yang, M., Pang, B., Vara, M., & Xia, Y. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00193 · Cited by 1,162
A review of clinical photoacoustic imaging: Current and future trends
Attia, A. B. E., Balasundaram, G., Moothanchery, M., Dinish, U. S., Bi, R., Ntziachristos, V., & Olivo, M. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.100144 · Cited by 878
Plasmonic Photothermal Nanoparticles for Biomedical Applications
Kim, M., Lee, J., & Nam, J. (2019) · Advanced Science · doi:10.1002/advs.201900471 · Cited by 751
Quantitative spectroscopic photoacoustic imaging: a review
Cox, B., Laufer, J. G., Arridge, S. R., & Beard, P. C. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.6.061202 · Cited by 720
Self-citationSolving inverse problems using data-driven models
Arridge, S., Maass, P., Öktem, O., & Schönlieb, C.-B. (2019) · Acta Numerica · doi:10.1017/s0962492919000059 · Cited by 686
Photoacoustic Imaging: Contrast Agents and Their Biomedical Applications
Fu, Q., Zhu, R., Song, J., Yang, H., & Chen, X. (2019) · Advanced Materials · doi:10.1002/adma.201805875 · Cited by 681
PHOTOACOUSTIC TOMOGRAPHY: PRINCIPLES AND ADVANCES (Invited Review)
Xia, J., Yao, J., & Wang, L. H. V. (2014) · Progress In Electromagnetics Research · doi:10.2528/pier14032303 · Cited by 646
Yao, J., & Wang, L. V. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200060 · Cited by 616
Song, X., Feng, L., Liang, C., Yang, K., & Liu, Z. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b02365 · Cited by 581
Photoacoustic clinical imaging
Steinberg, I., Huland, D. M., Vermesh, O., Frostig, H. E., Tummers, W. S., & Gambhir, S. S. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.05.001 · Cited by 553
Fully Dense UNet for 2-D Sparse Photoacoustic Tomography Artifact Removal
Guan, S., Khan, A. A., Sikdar, S., & Chitnis, P. V. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2912935 · Cited by 538
Dai, C., Chen, Y., Jing, X., Xiang, L., Yang, D., Lin, H., Liu, Z., Han, X., & Wu, R. (2017) · ACS Nano · doi:10.1021/acsnano.7b07241 · Cited by 520
Fluorescent small organic probes for biosensing
Tian, X., Murfin, L. C., Wu, L., Lewis, S. E., & James, T. D. (2021) · Chemical Science · doi:10.1039/d0sc06928k · Cited by 520
Dong, Z., Feng, L., Hao, Y., Chen, M., Gao, M., Chao, Y., Zhao, H., Zhu, W., Liu, J., Liang, C., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b11036 · Cited by 490
Deep in vivo photoacoustic imaging of mammalian tissues using a tyrosinase-based genetic reporter
Jathoul, A. P., Laufer, J., Ogunlade, O., Treeby, B., Cox, B., Zhang, E., Johnson, P., Pizzey, A. R., Philip, B., Marafioti, T., et al. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.22 · Cited by 442
Self-citationTutorial on photoacoustic tomography
Zhou, Y., Yao, J., & Wang, L. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.6.061007 · Cited by 421
Sensitivity of photoacoustic microscopy
Yao, J., & Wang, L. V. (2014) · Photoacoustics · doi:10.1016/j.pacs.2014.04.002 · Cited by 418
Ultrasensitive plano-concave optical microresonators for ultrasound sensing
Guggenheim, J. A., Li, J., Allen, T. J., Colchester, R. J., Noimark, S., Ogunlade, O., Parkin, I. P., Papakonstantinou, I., Desjardins, A. E., Zhang, E. Z., et al. (2017) · Nature Photonics · doi:10.1038/s41566-017-0027-x · Cited by 391
Self-citationLooking at sound: optoacoustics with all-optical ultrasound detection
Wissmeyer, G., Pleitez, M. A., Rosenthal, A., & Ntziachristos, V. (2018) · Light: Science & Applications · doi:10.1038/s41377-018-0036-7 · Cited by 374
Nanomaterials for Nanotheranostics: Tuning Their Properties According to Disease Needs
Wong, X. Y., Sena-Torralba, A., Álvarez-Diduk, R., Muthoosamy, K., & Merkoçi, A. (2020) · ACS Nano · doi:10.1021/acsnano.9b08133 · Cited by 363
Photoacoustic tomography of blood oxygenation: A mini review
Li, M., Tang, Y., & Yao, J. (2018) · Photoacoustics · doi:10.1016/j.pacs.2018.05.001 · Cited by 359
Model-Based Learning for Accelerated, Limited-View 3-D Photoacoustic Tomography
Hauptmann, A., Lucka, F., Betcke, M., Huynh, N., Adler, J., Cox, B., Beard, P., Ourselin, S., & Arridge, S. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2820382 · Cited by 339
Self-citationAdvanced optoacoustic methods for multiscale imaging of in vivo dynamics
Deán-Ben, X. L., Gottschalk, S., Mc Larney, B., Shoham, S., & Razansky, D. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00765a · Cited by 337
Photoacoustics: a historical review
Manohar, S., & Razansky, D. (2016) · Advances in Optics and Photonics · doi:10.1364/aop.8.000586 · Cited by 319
Systemic Review of Biodegradable Nanomaterials in Nanomedicine
Su, S., & Kang, P. M. (2020) · Nanomaterials · doi:10.3390/nano10040656 · Cited by 312
In vivo preclinical photoacoustic imaging of tumor vasculature development and therapy
Laufer, J. G., Zhang, E. Z., Treeby, B. E., Cox, B. T., Beard, P. C., Johnson, P., & Pedley, B. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.5.056016 · Cited by 308
Self-citationDeep learning for photoacoustic tomography from sparse data
Antholzer, S., Haltmeier, M., & Schwab, J. (2019) · Inverse Problems in Science and Engineering · doi:10.1080/17415977.2018.1518444 · Cited by 301
The Emergence and Evolution of Borophene
Ou, M., Wang, X., Yu, L., Liu, C., Tao, W., Ji, X., & Mei, L. (2021) · Advanced Science · doi:10.1002/advs.202001801 · Cited by 290
Medical Imaging of Microrobots: Toward In Vivo Applications
Aziz, A., Pane, S., Iacovacci, V., Koukourakis, N., Czarske, J., Menciassi, A., Medina-Sánchez, M., & Schmidt, O. G. (2020) · ACS Nano · doi:10.1021/acsnano.0c05530 · Cited by 287
Toi, M., Asao, Y., Matsumoto, Y., Sekiguchi, H., Yoshikawa, A., Takada, M., Kataoka, M., Endo, T., Kawaguchi-Sakita, N., Kawashima, M., et al. (2017) · Scientific Reports · doi:10.1038/srep41970 · Cited by 273
Engineering Plasmonic Nanoparticles for Enhanced Photoacoustic Imaging
Mantri, Y., & Jokerst, J. V. (2020) · ACS Nano · doi:10.1021/acsnano.0c05215 · Cited by 256
Review of Photoacoustic Flow Imaging: Its Current State and Its Promises
van den Berg, P. J., Daoudi, K., & Steenbergen, W. (2015) · Photoacoustics · doi:10.1016/j.pacs.2015.08.001 · Cited by 84
Acoustic resolution photoacoustic Doppler velocimetry in blood-mimicking fluids
Brunker, J., & Beard, P. (2016) · Scientific Reports · doi:10.1038/srep20902 · Cited by 32
Self-citationZhang, R., Yao, J., Maslov, K. I., & Wang, L. V. (2013) · Applied Physics Letters · doi:10.1063/1.4819735 · Cited by 17
Metadata
- Authors
- Beard, P.
- Venue
- Interface Focus
- Publisher
- The Royal Society
- Published
- 2011-06-22
- Volume
- 1
- Issue
- 4
- Pages
- 602-631
- ISSN
- 2042-8898 (ISSN-L)
- 2042-8901
- OpenAlex
- W2157048271
- Cited by
- 2,205
- References
- 95
- FWCI
- 39.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.