High Accuracy Correction of Blackbody Radiation Shift in an Optical Lattice Clock
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
We have determined the frequency shift that blackbody radiation is inducing on the $5{s}^{2}$ $^{1}S_{0}--5s5p$ $^{3}P_{0}$ clock transition in strontium. Previously its uncertainty limited the uncertainty of strontium lattice clocks to $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$. Now the uncertainty associated with the blackbody radiation shift correction translates to a $5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$ relative frequency uncertainty at room temperature. Our evaluation is based on a measurement of the differential dc polarizability of the two clock states and on a modeling of the dynamic contribution using this value and experimental data for other atomic properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Making optical atomic clocks more stable with 10−16-level laser stabilization
Jiang, Y. Y., Ludlow, A. D., Lemke, N. D., Fox, R. W., Sherman, J. A., Ma, L.-S., & Oates, C. W. (2011) · Nature Photonics · doi:10.1038/nphoton.2010.313 · Cited by 462
Optical-Frequency Transfer over a Single-Span 1840 km Fiber Link
Droste, S., Ozimek, F., Udem, T., Predehl, K., Hänsch, T. W., Schnatz, H., Grosche, G., & Holzwarth, R. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.110801 · Cited by 315
Porsev, S. G., & Derevianko, A. (2006) · Physical Review A · doi:10.1103/physreva.74.020502 · Cited by 279
A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Self-citationBjerhammar, A. (1985) · Bulletin Géodésique · doi:10.1007/bf02520327 · Cited by 165
Frequency comparison of optical lattice clocks beyond the Dick limit
Takamoto, M., Takano, T., & Katori, H. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.34 · Cited by 154
The87Sr optical frequency standard at PTB
Falke, S., Schnatz, H., Winfred, J. S. R. V., Middelmann, T., Vogt, S., Weyers, S., Lipphardt, B., Grosche, G., Riehle, F., Sterr, U., et al. (2011) · Metrologia · doi:10.1088/0026-1394/48/5/022 · Cited by 129
Self-citationAccuracy evaluation of an optical lattice clock with bosonic atoms
Baillard, X., Fouché, M., Le Targat, R., Westergaard, P. G., Lecallier, A., Le Coq, Y., Rovera, G. D., Bize, S., & Lemonde, P. (2007) · Optics Letters · doi:10.1364/ol.32.001812 · Cited by 100
Cs-based optical frequency measurement using cross-linked optical and microwave oscillators
Tamm, C., Huntemann, N., Lipphardt, B., Gerginov, V., Nemitz, N., Kazda, M., Weyers, S., & Peik, E. (2014) · Physical Review A · doi:10.1103/physreva.89.023820 · Cited by 72
Research works printed but not linked: 27
- 10.1103/PhysRevLett.93.170801 · DOI · Paper page
- 10.1139/p08-053 · DOI
- 10.1103/PhysRevLett.100.140801 · DOI · Paper page
- 10.1038/nphoton.2011.45 · DOI · Paper page
- 10.1088/0026-1394/45/5/008 · DOI · Paper page
- 10.1103/PhysRevLett.108.153002 · DOI · Paper page
- 10.1140/epjd/e2007-00330-3 · DOI · Paper page
- 10.1143/APEX.4.082203 · DOI · Paper page
- 10.1103/PhysRevA.78.032508 · DOI · Paper page
- 10.1103/PhysRevA.57.436 · DOI · Paper page
- 10.1109/TUFFC.2010.1455 · DOI
- 10.1088/1367-2630/14/7/073020 · DOI
- 10.1109/TIM.2008.2007042 · DOI
- P. Franke, 2010, PTB Mitteilungen, 120, 16
- 10.1103/PhysRevA.72.062111 · DOI · Paper page
- 10.1088/0264-9381/23/7/026 · doi:10.1088/0264-9381/23/7/026
- 10.1063/1.323539 · DOI · Paper page
- 10.1109/TIM.2010.2088470 · DOI · Paper page
- E. U. Condon, 1953, The Theory of Atomic Spectra
- 10.1103/PhysRevA.70.023414 · DOI · Paper page
- 10.1103/PhysRevA.86.029904 · DOI
- 10.1088/0953-4075/24/18/019 · doi:10.1088/0953-4075/24/18/019
- 10.1007/BF01437201 · doi:10.1007/bf01437201
- 10.1103/PhysRevA.28.2051 · doi:10.1103/physreva.28.2051
- 10.1103/PhysRevC.32.2058 · doi:10.1103/physrevc.32.2058
- 10.1007/BF01411600 · doi:10.1007/bf01411600
- 10.1063/1.3077727 · doi:10.1063/1.3077727
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
“After averaging (see Methods), we determine the ratio to be R = ν Yb / ν Sr = 1.207,507,039,343,338,41(34).”
InfluentialSelf-citationJILA SrI optical lattice clock with uncertainty of 2.0 × 10 − 18
Bothwell, T., Kedar, D., Oelker, E., Robinson, J. M., Bromley, S. L., Tew, W. L., Ye, J., & Kennedy, C. J. (2019) · Metrologia · doi:10.1088/1681-7575/ab4089 · Cited by 324
“13023(6) Hz [19], νdyn = −148.”
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“Its uncertainty arises from imprecise knowledge of Δαs (uncertainty δΔαs), obtained from measurements (Dubé et al., 2014; Huntemann et al., 2016; Middelmann et al., 2012; Sherman et al., 2012) or calculations (Safronova et al.”
Self-citationExperimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250
Frequency ratio of Yb and Sr clocks with 5 × 10−17 uncertainty at 150 seconds averaging time
Nemitz, N., Ohkubo, T., Takamoto, M., Ushijima, I., Das, M., Ohmae, N., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.20 · Cited by 221
Clock with 8 × 10 − 19 Systematic Uncertainty
Aeppli, A., Kim, K., Warfield, W., Safronova, M. S., & Ye, J. (2024) · Physical Review Letters · doi:10.1103/physrevlett.133.023401 · Cited by 211
A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Self-citationTowards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174
“A low uncertainty is achievable since the sensitivity coefficient is very well established [34].”
BackgroundMethodOriglia, S., Pramod, M. S., Schiller, S., Singh, Y., Bongs, K., Schwarz, R., Al-Masoudi, A., Dörscher, S., Herbers, S., Häfner, S., et al. (2018) · Physical Review A · doi:10.1103/physreva.98.053443 · Cited by 142
Self-citationAtomic Clock with 1 × 10 − 18 Room-Temperature Blackbody Stark Uncertainty
Beloy, K., Hinkley, N., Phillips, N. B., Sherman, J. A., Schioppo, M., Lehman, J., Feldman, A., Hanssen, L. M., Oates, C. W., & Ludlow, A. D. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.260801 · Cited by 137
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Lodewyck, J., Bilicki, S., Bookjans, E., Robyr, J.-L., Shi, C., Vallet, G., Le Targat, R., Nicolodi, D., Le Coq, Y., Guéna, J., et al. (2016) · Metrologia · doi:10.1088/0026-1394/53/4/1123 · Cited by 102
“the static and dynamic polarizabilities reported in [11].”
BackgroundStrategies for reducing the light shift in atomic clocks
Katori, H., Ovsiannikov, V. D., Marmo, S. I., & Palchikov, V. G. (2015) · Physical Review A · doi:10.1103/physreva.91.052503 · Cited by 74
Intercontinental comparison of optical atomic clocks through very long baseline interferometry
Pizzocaro, M., Sekido, M., Takefuji, K., Ujihara, H., Hachisu, H., Nemitz, N., Tsutsumi, M., Kondo, T., Kawai, E., Ichikawa, R., et al. (2021) · Nature Physics · doi:10.1038/s41567-020-01038-6 · Cited by 64
Lattice-induced photon scattering in an optical lattice clock
Dörscher, S., Schwarz, R., Al-Masoudi, A., Falke, S., Sterr, U., & Lisdat, C. (2018) · Physical Review A · doi:10.1103/physreva.97.063419 · Cited by 60
Self-citationHachisu, H., Petit, G., Nakagawa, F., Hanado, Y., & Ido, T. (2017) · Optics Express · doi:10.1364/oe.25.008511 · Cited by 53
Ca+40 ion optical clock with micromotion-induced shifts below 1×10−18
Huang (2019) · Physical Review A · doi:10.1103/physreva.99.011401 · Cited by 51
Intermittent optical frequency measurements to reduce the dead time uncertainty of frequency link
Hachisu, H., & Ido, T. (2015) · Japanese Journal of Applied Physics · doi:10.7567/jjap.54.112401 · Cited by 48
Polarizabilities of theSr87clock transition
Shi, C., Robyr, J.-L., Eismann, U., Zawada, M., Lorini, L., Le Targat, R., & Lodewyck, J. (2015) · Physical Review A · doi:10.1103/physreva.92.012516 · Cited by 37
“This value is in agreement with the estimation given in [9] from Monte-Carlo simulation using transition strengths and scalar polarizabilities of the clock states at various frequencies.”
BackgroundResultLong-distance chronometric leveling with a portable optical clock
Grotti, J., Nosske, I., Koller, S. B., Herbers, S., Denker, H., Timmen, L., Vishnyakova, G., Grosche, G., Waterholter, T., Kuhl, A., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.l061001 · Cited by 33
“In combination with a deep lattice of 50 E r and more, tunneling is strongly suppressed as are tunneling-related frequency shifts [S16].”
Self-citationFaraday-Shielded dc Stark-Shift-Free Optical Lattice Clock
Beloy, K., Zhang, X., McGrew, W. F., Hinkley, N., Yoon, T. H., Nicolodi, D., Fasano, R. J., Schäffer, S. A., Brown, R. C., & Ludlow, A. D. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.183201 · Cited by 20
A proof-of-concept model of compact and high-performance 87Sr optical lattice clock for space
Guo, F., Tan, W., Zhou, C.-H., Xia, J., Chen, Y.-X., Liang, T., Liu, Q., Liu, Y., He, D.-J., Zhou, Y.-Z., et al. (2021) · AIP Advances · doi:10.1063/5.0064087 · Cited by 16
Progress on the optical lattice clock
Ludlow, A. D., & Ye, J. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.008 · Cited by 14
Metadata
- Authors
- Middelmann, T., Falke, S., Lisdat, C., & Sterr, U.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2012-12-27
- Volume
- 109
- Issue
- 26
- Pages
- 263004-263004
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2058209208
- Cited by
- 154
- References
- 11
- FWCI
- 8.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.