Skin contact force information in sensory nerve signals recorded by implanted cuff electrodes
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
When functional neuromuscular stimulation (FNS) is used to restore the use of paralyzed limbs after a spinal cord injury or stroke, it may be possible to control the stimulation using feedback information relayed by natural sensors in the skin. In this study the authors tested the hypothesis that the force applied on glabrous skin can be extracted from the electroneurographic (ENG) signal recorded from the sensory nerve. They used the central footpad of the cat hindlimb as a model of the human fingertip and recorded sensory activity with a cuff electrode chronically implanted around the tibial nerve. Their results showed that the tibial ENG signal, suitably filtered, rectified, and smoothed carries detailed static and dynamic information related to the force applied on the footpad. The authors derived a mathematical model of the force-ENG relation that provided accurate estimates of the ENG signal for a wide range of force profiles, amplitudes, and frequencies. Once fitted to data obtained in one recording session, the model could be made to fit data obtained in other sessions from the same cat, as well as from other cats, by simply adjusting its overall gain and offset. However, the model was noninvertible; i.e., the force could not be similarly predicted from the ENG signal, unless additional assumptions or restrictions were introduced. The authors discuss the reasons for these findings and their implications on the potential use of nerve signals as a source of continuous force feedback information suitable for closed-loop control of FNS.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Somatosensory, proprioceptive, and sympathetic activity in human peripheral nerves
Vallbo, A. B., Hagbarth, K. E., Torebjork, H. E., & Wallin, B. G. (1979) · Physiological Reviews · doi:10.1152/physrev.1979.59.4.919 · Cited by 1,507
Johansson, R. S., & Vallbo, A. B. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012619 · Cited by 1,291
Johansson, R. S. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012411 · Cited by 430
Tactile detection of slip: surface microgeometry and peripheral neural codes
Srinivasan, M. A., Whitehouse, J. M., & LaMotte, R. H. (1990) · Journal of Neurophysiology · doi:10.1152/jn.1990.63.6.1323 · Cited by 290
Long‐term effects of axotomy on neural activity during cat locomotion.
Gordon, T., Hoffer, J. A., Jhamandas, J., & Stein, R. B. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013283 · Cited by 65
Self-citationDiaphragm pacing by electrical stimulation of the phrenic nerve
Glenn, W. W., & Phelps, M. L. (1985) · Neurosurgery · doi:10.1097/00006123-198512000-00021 · Cited by 15
Research works printed but not linked: 42
- 10.1007/BF00236209 · DOI · Paper page
- webster, 1992, Neural Prostheses Replacing Motor Function After Disease or Disability, 88
- thomas, 1992, Tactile afferent function after human cervical spinal cord injury, 30th Annu Meeting Soc Neuroscience, 831
- 10.1109/TBME.1987.325979 · DOI · Paper page
- skoglund, 1973, Handbook of physiology, ii, 111, 10.1007/978-3-642-65438-1_5 · DOI
- vallbo, 1984, Properties of cutaneous mechanoreceptors in the human hand related to touch sensation, Human Neurobiology, 3, 3
- 10.1016/0014-4886(68)90041-1 · DOI · Paper page
- 10.1126/science.183.4121.161 · DOI
- hensel, 1973, Handbook of Sensory Physiology, ii, 79, 10.1007/978-3-642-65438-1_4 · DOI
- 10.1007/978-1-4899-0597-0 · DOI · Paper page
- 10.1385/0-89603-185-3:65 · DOI · Paper page
- hoffer, 1986, A natural 'force sensor' suitable for closed-loop control of functional neuromuscular stimulation, Proc 5th Vienna Int Workshop Functional Electrostimulation, 47
- 10.1109/IEMBS.1989.96052 · DOI · Paper page
- 10.1109/IEMBS.1991.684250 · DOI
- hoffer, 1992, Neural Prostheses Replacing Motor Function After Disease or Disability, 99
- horch, 1985, Long term adaptation of cutaneous type I and type II mechanoreceptors in the cat, Chin J of Physiol Sci, 1, 54
- 10.1113/jphysiol.1979.sp012809 · DOI · Paper page
- 10.1111/j.1748-1716.1970.tb04783.x · DOI · Paper page
- sinkjaer, 1991, Whole sensory nerve recordings in human?An application for neural prostheses, Proc Annu Int Conf IEEE EMBS, 13, 900
- donaldson, 1986, A 24-output implantable stimulator for FES, Proc 5th Vienna Int Workshop Functional Electrostimulation, 197
- 10.1111/j.1748-1716.1990.tb08969.x · DOI
- 10.1111/1523-1747.ep12544620 · DOI
- sinkjaer, 1992, The use of natural sensory nerve signals as an advanced heel-swithc in drop-foot patients, Proc 5th Vienna Int Workshop Functional Electrostimulation, 134
- 10.1227/00006123-198512000-00021 · doi:10.1227/00006123-198512000-00021 · Paper page
- haugland, 1989, Natural Sensory Feedback for Closed-loop Control of Paralyzed Muscles
- 1977, Functional Electrical Stimulation Applications in Neural Prostheses
- 10.1109/10.68205 · DOI
- haugland, 1992, Force information in whole human sensory nerve recordings, Proc 5th Vienna Int Workshop Functional Electrostimulation, 130
- burgess, 1973, Handbook of physiology, ii, 29, 10.1007/978-3-642-65438-1_3 · DOI · Paper page
- 10.1113/jphysiol.1971.sp009598 · DOI
- 10.1007/BF02446866 · DOI
- mountcastle, 1974, Medical Physiology, 1, 285
- peckham, 1992, Neural Prostheses Replacing Motor Function After Disease or Disability, 162
- 10.1016/0006-8993(91)91126-L · DOI
- 10.1109/TBME.1986.325808 · DOI · Paper page
- press, 1988, Numerical Recipes in C The Art of Scientific Computing
- 10.1109/86.296344 · DOI · Paper page
- 10.1007/BF02423508 · DOI
- 10.1016/0006-8993(71)90655-X · DOI
- sakata, 1972, Compressive behaviour of a physiological tissue, Biorheology, 9, 173, 10.3233/BIR-1972-9309 · doi:10.3233/bir-1972-9309
- 10.1113/jphysiol.1977.sp011768 · DOI · Paper page
- 10.1016/0304-3940(90)90792-8 · doi:10.1016/0304-3940(90)90792-8
Cited by
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Simulating tactile signals from the whole hand with millisecond precision
Saal, H. P., Delhaye, B. P., Rayhaun, B. C., & Bensmaia, S. J. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1704856114 · Cited by 264
Cuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215
Ortiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144
“In animal experiments, cuff electrodes have been successfully used to measure respiratory output [37] and forces applied to the footpad [38,39].”
MethodYoo, P. B., & Durand, D. M. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851482 · Cited by 106
“and distinguish between different active fascicles [23], [24].”
Metadata
- Authors
- Haugland, M. K., Hoffer, J. A., & Sinkjaer, T.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1994-03
- Volume
- 2
- Issue
- 1
- Pages
- 18-28
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2032670029
- Cited by
- 122
- References
- 6
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Skin contact force information in sensory nerve signals recorded by implanted cuff electrodes. https://app.cochat.ai/papers/10.1109/86.296346
- The paper
- Haugland, M. K., Hoffer, J. A., & Sinkjaer, T. (1994). Skin contact force information in sensory nerve signals recorded by implanted cuff electrodes. IEEE Transactions on Rehabilitation Engineering. https://doi.org/10.1109/86.296346
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.