Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Open accessThe DOI matches its Crossref record; 341 of the 341 references it cites were found in a registry or an index; 24 of the 225 sources its claims cite were checked for support.
Abstract
The issues of monitoring and fault diagnosis of drives with permanent magnet synchronous motors (PMSM) are currently very topical due to the increasing use of these drives in safety-critical devices. Every year, more and more articles on this subject are published. Therefore, the aim of this article is to update the overview of diagnostic methods and techniques for PMSM drives. Each of the main chapters of the article focuses on a specific element of the drive system (motor, power converter, measuring sensors), with particular emphasis on the components of the motor (stator windings, magnets, bearings, rotor). The main sections on PMSM fault diagnosis are divided according to the type of methods used to obtain the symptoms of the damage. In addition, a review of methods using the analysis of control structure signals for the diagnosis of damage to a vector-controlled motor is presented, as well as the latest achievements of researchers in the field of shallow and deep neural networks for the detection and classification of PMSM drives failures. Based on the presented literature analyses, some development trends and challenges related to the development of diagnostics and fault-tolerant control of PMSM drives are discussed in the conclusion part.
Overview
CoChat Summary
TL;DR
This IEEE Access review surveys fault diagnosis and fault-tolerant control (FTC) for permanent magnet synchronous motor (PMSM) drives, covering motor, converter, and sensor faults and methods based on signal analysis, mathematical models, control-structure signals, and artificial intelligence. It synthesizes the literature and identifies future challenges in transient diagnostics, multiple-fault diagnosis, AI/deep learning, hardware implementation, and prognostics.
Key findings
- The review classifies PMSM faults into electrical, magnetic, and mechanical types and cites component failure statistics: stator winding failures account for 36–66% of AC motor breakdowns, bearing faults 13–41%, bearing failures about 40–50% of all electric motor failures, power semiconductor device damages about 35% of all adjustable-speed-drive faults, DC-link capacitors about 30% of frequency-converter failures, and transistor failures 12% of all electric-drive failures.
- Signal-analysis methods dominate PMSM diagnostics: FFT/MCSA/EPVA are widely used for inter-turn short circuits (ITSCs) and demagnetization, while time-frequency methods such as STFT, WT, WVD, CWD, and HHT address non-stationary conditions; control-structure signals can enable sensorless diagnostics but are sensitive to controller bandwidth.
- AI-based diagnostics are reviewed: shallow neural networks (MLP, RBF, SOM, PNN, BNN) require preprocessing, while deep networks (CNN, LSTM) allow direct feature extraction; Table IX reports literature classification accuracies such as MLP 99.02% on vibrations, CNN 99.38% on flux, CNN 99.28% on stator currents, and SOM 93.00% on vibrations.
- FTC is divided into passive and active approaches; active FTC uses fault detection and diagnosis with reconfiguration or compensation, speed-sensor FTC relies on sensorless estimators, current-sensor FTC uses observers, and inverter FTC often uses hardware redundancy; ITSC-FTC strategies remain relatively rare and mostly target torque-ripple or copper-loss reduction, with few limiting short-circuit current.
Methods
- Design: state-of-the-art review/survey; it compares itself with existing PMSM diagnostic surveys in Table I and organizes the literature by fault location and diagnostic method.
- Data or sample: no primary experimental sample; it analyzes published methods and presents tabular summaries (Tables II–X) for ITSC, demagnetization, bearing, eccentricity, unbalance, misalignment, converter, sensor faults, AI methods, and FTC.
- Main analysis: categorizes methods into frequency-domain, time-frequency, time-domain/statistical, model-based, control-structure-signal, and AI-based approaches, discussing advantages, disadvantages, and future trends.
Limitations
- Paper-stated: future challenges include diagnostics during transients, hardware implementation, failure prediction/prognostics, data storage and cloud transfer, multiple-fault diagnosis, AI/deep-learning development for PMSM drives, transfer learning, and real-time fault detection.
- Paper-stated: many PMSM fault diagnosis methods lack hardware implementation; deep neural networks are limited by structural complexity; few papers address ITSC-FTC and fault-current mitigation; control-structure-based mechanical fault diagnosis needs further work.
- Evident from the text: as a review, it reports no new experimental validation; some cited methods are simulation-only or inconclusive (e.g., DWT+NN bearing diagnosis in DTC is described as simulation-only and rather inconclusive), and the AI accuracy table is literature-derived rather than a controlled benchmark.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures

















Verification
Claims the paper makes
19 Valid · 20 Not valid · 149 Not checked · 149 Own results and interpretations
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“Greater sensitivity of this component to the stator winding fault compared to the FFT of the stator phase current is also emphasized.”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > A. FREQUENCY DOMAIN METHODS
What the sources say
- Disputedcites [43] sourceExperimental — accuracy not yet measured
Section 5 (page not provided) compares the fault indicators and identifies the 3fs component in the FFT spectrum of the stator phase current—not the 2fs component—as the most sensitive across the tested load-torque range. The Conclusions likewise describe both indicators as sensitive, without saying that 2fs is more sensitive. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
- Not matchedcites [45]- [47]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“According to [20], the greatest and most obvious increase in the case of this fault is the increase in the amplitude of the 3fs component, which has also been confirmed by the results presented by the authors in [42] and [43].”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > A. FREQUENCY DOMAIN METHODS
What the sources say
- Partly supportedcites [20] sourceExperimental — accuracy not yet measured
Section 3.2.1 (Frequency Domain Methods) says that for an inter-turn short circuit, the most obvious feature is an increase in the third-harmonic amplitude, corresponding to 3fs. It does not establish that this is the greatest increase in magnitude among the components. (LLM, conf=0.83)
- Partly supportedcites [42] sourceExperimental — accuracy not yet measured
Section 6 (Conclusions; page not available in our copy) reports that inter-turn short circuits increase the stator current’s 3fs harmonic and that its amplitude is much greater under field-oriented control than under scalar control. It does not establish that this is the greatest increase among fault-related components; the claim also omits the control-structure qualification. (LLM, conf=0.83)
- Supportedcites [43] source
Section 6 (Conclusions; page not provided) calls the increase in the 3fs component’s amplitude the most significant symptom of stator-winding damage. Section 4.1 also reports a large increase in that component after an interturn short circuit. (LLM, conf=0.94)
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“In all of these papers, the Authors conclude that the increase of the 2fs component amplitude in the stator phase current space vector module spectrum is a symptom of a stator winding fault.”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > A. FREQUENCY DOMAIN METHODS
What the sources say
- Supportedcites [43] source
Section 2.2 states that, following an inter-turn short-circuit, the 2fs component increases in the FFT spectrum of the stator phase current space vector magnitude. This directly supports the attributed symptom of a stator winding fault. (LLM, conf=0.93)
- Not matchedcites [45]- [47]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
boostedstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“The limitation of this approach is mentioned in [60] to measure the ZSVC, the access to the neutral point of the stator winding is needed.”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > A. FREQUENCY DOMAIN METHODS
What the sources say
- Supportedcites [60] source
The Conclusion explicitly states that an accessible neutral point of the stator windings is needed to measure the ZSVC. It also notes that this condition is met in a fault-tolerant PMSM drive system. (LLM, conf=0.95)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“The basic diagnostic signals in eccentricity diagnosis are: stator current [135], [143]- [146], [150], [151], [156]- [159], [161], [162], mechanical vibrations [149], [155], [156], noise [155], an airgap search coil voltage [149], [152], [156], [160], stator voltage [159], speed [159], load torque [159], d-axis stator inductance Ld [147], [148], BEMF [160] and unbalanced magnetic pull [153], [154]”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > B. ECCENTRICITY FAULTS
What the sources say
- Not checked — no full text of the sourcecites [135] source
- Not matchedcites [143]-[146]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Supportedcites [150] source
This source is cited within the stator-current group of references, not for the entire list of signals. The Introduction identifies stator current as a prevalent monitored signal for motor fault detection, and Section 5 analyzes it for static eccentricity diagnosis in LSPMSMs. Page numbers are not available in our copy. (LLM, conf=0.93)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
150 more claims · 5 with their cited sources checked
Create a free account to see all 337 claims and to verify the 1 reference still open.
- It may state two separate claims as one. 113
- Probably not a substantial claim. 91
- The quote only partly states this claim. 3
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > C. DEEP NEURAL NETWORKS APPLICATION IN PMSM DRIVES
“The possibility of direct extraction of the input signal features in the diagnostics of PMSM stator windings faults has been described in [220], [222], [223], [229], [237].”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > B. SHALLOW NEURAL NETWORKS APPLICATION IN PMSM DRIVES
“[237] + + CNN FFT IsABC”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > TABLE I COMPARISON OF THIS PAPER WITH EXISTING SURVEYS AND REVIEW PAPERS ON DIAGNOSTICS OF PMSM DRIVES
“[15] 2015 125 (120) 1997-2016”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > References
“15. M. Cheng, J. Hang, and J.Zhang, "Overview of fault diagnosis theory and method for permanent magnet machine," Chinese Journal of Electrical Eng., vol. 1 no. 1, pp. 21-36, 2015..”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > IX. FAULT DETECTION OF PMSM DRIVE COMPONENTS AND FAULT-TOLERANT CONTROL A. FREQUENCY CONVERTER FAULTS
“The voltage-based method was also applied in [274] for open switch fault diagnosis in a voltage-oriented controlled AC/DC line side converter.”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > References
“274. M. Bourogaoui, H. B. A. Sethom, and I. S. Belkhodja. "Speed/position sensor fault tolerant control in adjustable speed drives -a review." ISA Transactions, vol. 64, pp. 269-284, 2016.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > B. SHALLOW NEURAL NETWORKS APPLICATION IN PMSM DRIVES
“[216] + MLP DIRECT IsABC”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > C. DEEP NEURAL NETWORKS APPLICATION IN PMSM DRIVES
“[216] + + MLP 98,50% (FFT) IsABC + Te + + MLP 96,10% (STAT) IsABC + Te”
Citations
Cites
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
A review of induction motors signature analysis as a medium for faults detection
El Hachemi Benbouzid, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873206 · Cited by 1,602
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278 · cited 1×
“According to [238], [239], power semiconductor device damages account for approximately 35% of all ASD faults.”
BackgroundAdvances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140 · cited 1×
“Additionally, the FFT can even mask components that appear at a given moment of time but are of very short duration [10], [32].”
BackgroundA Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
A High-Speed Sliding-Mode Observer for the Sensorless Speed Control of a PMSM
Kim, H., Son, J., & Lee, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2098357 · Cited by 733 · cited 3×
“In [283] the SMO was developed with sign-type switching function replaced by a sigmoid function with some boundary”
BackgroundMethodWelchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724 · cited 2×
“A detailed overview of fault-tolerant inverter topologies is presented in [307], [308].”
BackgroundNew Sliding-Mode Observer for Position Sensorless Control of Permanent-Magnet Synchronous Motor
Qiao, Z., Shi, T., Wang, Y., Yan, Y., Xia, C., & He, X. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2206359 · Cited by 602 · cited 2×
“These could be: extended observer [279], SMO [280], [283], [284] or super-twisting sliding mode observer (ST-SMO) [285], MRAS estimator [281], KF [282]”
BackgroundMethodTrends in Fault Diagnosis for Electrical Machines: A Review of Diagnostic Techniques
Henao, H., Capolino, G.-A., Fernandez-Cabanas, M., Filippetti, F., Bruzzese, C., Strangas, E., Pusca, R., Estima, J., Riera-Guasp, M., & Hedayati-Kia, S. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2287651 · Cited by 602 · cited 3×
“The popularity of this method is related to its simplicity, low cost and online machine state monitoring capabilities [11].”
MethodReport of Large Motor Reliability Survey of Industrial and Commercial Installations, Part I
(1985) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1985.349532 · Cited by 602
Research works printed but not linked: 7
- Krichen, Fault detection and diagnosis methods in permanent magnet synchronous machines: A review, 229
- Varal, 2017, Bearing fault analysis of permanent magnet synchronous motor (PMSM) using current signature analysis, Int. Res. J. Eng. Technol., 4, 410
- Abbas, 2014, Bearings fault diagnosis in direct torque control permanent magnet synchronous motor based on discrete wavelet transform and artificial neural network, Int. J. Adv. Eng. Technol., 7, 341
- 10.1049/iet-epa.2012.0316 · DOI · Paper page
- 10.1109/TIE.2017.2688973 · DOI · Paper page
- 10.1109/TEC.2017.2726142 · DOI · Paper page
- 10.1109/TEC.2019.2936225 · DOI · Paper page
Cited by
Pietrzak, P., & Wolkiewicz, M. (2023) · Sensors · doi:10.3390/s23041757 · Cited by 76
“Damage to PMs can be divided into mechanical damage of the PM (cracks, chipping) and those associated with the phenomenon of demagnetization [1,8].”
BackgroundSelf-citationCheng, M., Zhou, J., Qian, W., Wang, B., Zhao, C., & Han, P. (2024) · Chinese Journal of Electrical Engineering · doi:10.23919/cjee.2023.000048 · Cited by 80
El-Dalahmeh, M., Al‐Greer, M., Bashir, I., El‐Dalahmeh, M., Demirel, A., & Keysan, O. (2023) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2023.108894 · Cited by 73
Mueller, P. N., Woelfl, L., & Can, S. (2023) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2023.106834 · Cited by 58
Fault Diagnosis of Electric Motors by a Channel-Wise Regulated CNN and Differential of STFT
Mohammad‐Alikhani, A., Jamshidpour, E., Dhale, S., Akrami, M., Pardhan, S., & Nahid‐Mobarakeh, B. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3532556 · Cited by 53
Teler, K., Skowron, M., & Orłowska-Kowalska, T. (2023) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2023.3336348 · Cited by 42
Self-citationMachine Learning-Based Stator Current Data-Driven PMSM Stator Winding Fault Diagnosis
Pietrzak, P., & Wolkiewicz, M. (2022) · Sensors · doi:10.3390/s22249668 · Cited by 44
“Therefore, new methods are still being sought, based on the measurement and processing of diagnostic signals, allowing for real-time monitoring of motors condition and alerting the user in the initial stage of failure [5].”
BackgroundMethodSelf-citationDaas, A., Sari, B., Jia, J., & Rigatos, G. G. (2024) · Measurement · doi:10.1016/j.measurement.2024.116023 · Cited by 43
Fault Detection of Permanent Magnet Synchronous Machines: An Overview
Li, H., Zhu, Z. Q., Azar, Z., Clark, R., & Wu, Z. (2025) · Energies · doi:10.3390/en18030534 · Cited by 42
Öner, M. Ü., Şahin, İ., & Keysan, O. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3274052 · Cited by 38
Ali, N., Wang, Q., Gao, Q., et al. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3266596 · Cited by 31
Pietrzak, P., & Wolkiewicz, M. (2023) · Electronics · doi:10.3390/electronics12071543 · Cited by 33
Self-citationLaadjal, K., Bento, F., Henriques, K., Cardoso, A. J. M., & Sahraoui, M. (2023) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2023.3234339 · Cited by 30
“efficiency, and minimal maintenance and repair costs [1].”
BackgroundSelf-supervised feature learning for motor fault diagnosis under various torque conditions
Lee, S. K., Kim, H., Chae, M., Oh, H. J., Yoon, H., & Youn, B. D. (2024) · Knowledge-Based Systems · doi:10.1016/j.knosys.2024.111465 · Cited by 32
Huang, Y., Yuan, B., Xu, S., & Han, T. (2022) · Processes · doi:10.3390/pr10091679 · Cited by 28
Jiang, Y., Ji, B., Zhang, J., Yan, J., & Li, W. (2024) · World Electric Vehicle Journal · doi:10.3390/wevj15040165 · Cited by 29
“The impacts and losses caused by stator The impacts and losses caused by stator winding short circuits in electric motors are extremely severe [7]. extremely severe [7].”
BackgroundRomdhane, M., Mohamed, N., & Mansouri, A. (2023) · Electronics · doi:10.3390/electronics12183758 · Cited by 28
Novák, Z. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3283690 · Cited by 30
“Themagnitudeofvibrationdependsontherigidity ofarotor,atypeofbearing,arotorbalancinggrade,andother factors[28].”
Ruiz-Sarrio, J. E., Daviu, J. A. A., & Martis, C. S. (2024) · Electronics · doi:10.3390/electronics13020375 · Cited by 27
Fault-Tolerant SRM Drives—A Review
Ali, N., & Narimani, M. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3392713 · Cited by 30
Recent Advances in Fault Detection and Analysis of Synchronous Motors: A Review
Gherghina, I.-S., Bizon, N., Iana, G. V., & Vasilică, B.-V. (2025) · Machines · doi:10.3390/machines13090815 · Cited by 37
Condition monitoring and fault diagnosis of industrial robots: A review
Lei, Y., Liu, H., Li, N., Cao, J., Qiao, Y., & Wang, H. (2024) · Science China Technological Sciences · doi:10.1007/s11431-024-2810-2 · Cited by 45
Double Normalization Fault Diagnosis Method for Open-Circuit Faults of PMSM Drives
Wang, W., Mao, Y., Cui, P., Fu, J., Hua, W., & Cheng, M. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3404402 · Cited by 23
Tang, M., Liang, L., Zheng, H., Chen, J., & Chen, D. (2024) · Sensors · doi:10.3390/s24082553 · Cited by 26
Jankowska, K. A., & Dybkowski, M. (2023) · Electronics · doi:10.3390/electronics12051170 · Cited by 25
Zhu, Y., Cai, S., & Li, B. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3344711 · Cited by 24
“Digital Object Identifier 10.1109/TTE.2023.3344711 The fault diagnostic methodologies for internal faults of PMSMs can be roughly divided into three categories: signal processing method, analytical modeling method, and artificial intelligence method [6].”
MethodInfluentialSkowron, M., Krzysztofiak, M., & Orłowska-Kowalska, T. (2022) · IEEE Access · doi:10.1109/access.2022.3211087 · Cited by 20
“methods, such as the Hilbert-Huang transform or wavelet transform [3].”
MethodSelf-citationFault Detection in Induction Machines Using Learning Models and Fourier Spectrum Image Analysis
Barrera, K., Burriel-Valencia, J., Sapena-Bañó, Á., & Martínez‐Román, J. (2025) · Sensors · doi:10.3390/s25020471 · Cited by 32
“On the other hand, the most common faults in the stator generally occur due to insulation degradation of the windings or overheating, as well as conditions that increase the risk of short circuits and reduce efficiency in energy conversion [5].”
Kamiński, M., & Tarczewski, T. (2023) · Energies · doi:10.3390/en16114441 · Cited by 23
Skowron, M., Teler, K., Adamczyk, M., & Orłowska-Kowalska, T. (2022) · Energies · doi:10.3390/en15186646 · Cited by 18
Self-citationSanter, P., Reinhard, J., Schindler, A., & Graichen, K. (2025) · Mechatronics · doi:10.1016/j.mechatronics.2025.103294 · Cited by 22
Piechocki, M., Pajchrowski, T., Kraft, M., Wolkiewicz, M., & Ewert, P. (2023) · Eksploatacja i Niezawodnosc - Maintenance and Reliability · doi:10.17531/ein/170114 · Cited by 20
“Nowadays, the most widely used strategies for anomaly detection in industrial applications based on induction motors are current signals analysis [31, 11] and mechanical vibration diagnosis [27, 10, 49].”
MethodSelf-citationFast Detection of Power Transistor Faults in SRM Drives Based on Transient Pulse Injection
Ali, N., Wang, Q., Gao, Q., et al. (2023) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2023.3293002 · Cited by 17
Fault diagnosis in electric machines and propellers for electrical propulsion aircraft: A review
Milfont, L. D., Ferreira, G. T. D. C., & Giesbrecht, M. (2024) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2024.109577 · Cited by 29
Challenges and Opportunities in Electric Propulsion Systems for Low-Altitude eVTOL Aircraft
Dai, L., Niu, S., Lyu, Z., Huang, X., & Chau, K. T. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3634566 · Cited by 37
“Classification, causes, impacts, diagnosis, and solutions of the motor system failures [132], [133], [134], [135], [136]. a) Open-circuit faults: Open-circuit faults occur when a phase winding disconnects, often due to connector or winding failures, disrupting magnetic flux generation [138].”
Reliable fuzzy control of uncertain nonlinear networked systems under actuator faults
Echreshavi, Z., Farbood, M., Shasadeghi, M., & Mobayen, S. (2023) · ISA Transactions · doi:10.1016/j.isatra.2023.07.007 · Cited by 19
Vlachou, V. I., Karakatsanis, T. S., & Efstathiou, D. E. (2025) · Applied System Innovation · doi:10.3390/asi8050154 · Cited by 23
Model-Based Luenberger State Observer for Detecting Interturn Short Circuits in PM Machines
Qin, Y., Li, G., Zhu, Z. Q., Foster, M. P., Stone, D. A., Jia, C. J., & Mckeever, P. (2024) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2024.3478840 · Cited by 17
“These methods employ diverse techniques for fault diagnosis, with common approaches, including expert systems, artificial neural networks (ANNs), and fuzzy logic [22].”
Sensor Fault Tolerant Control in Modern and Green Power Applications: A Review
Chandra, M. V. S. S., & Mohapatro, S. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3462971 · Cited by 22
“On similar lines, the research progress of the fault diagnostic methods for the PMSM drives is presented [10].”
BackgroundPermanent magnet synchronous motor demagnetization fault diagnosis based on PCA-ISSA-PNN
Yu, Y., Li, Y., Zeng, D., Hu, Y., & Yang, J. (2024) · Scientific Reports · doi:10.1038/s41598-024-72596-5 · Cited by 21
Vlachou, V. I., Karakatsanis, T. S., Efstathiou, D. E., Vlachou, E. I., Vologiannidis, S. D., Balaska, V. E., & Gasteratos, A. C. (2025) · Machines · doi:10.3390/machines13070549 · Cited by 22
Ding, B., Lu, Y., Lai, C., & Feng, G. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3519589 · Cited by 17
“The winding faults have been a common fault in the electrical machine [4], [5], [6], [7].”
Choi, Y., & Joe, I. (2024) · Electronics · doi:10.3390/electronics13193946 · Cited by 20
Fault Detection of Servo Motor Bearing Based on Speed Signal Under Variable-Speed Conditions
Huang, X. S., Zhang, J., & Cheng, M. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3381274 · Cited by 14
“W ITH the vigorous development of industrial automation, safety monitoring and diagnostic technologies in the servo system have gained increasing attention [1].”
BackgroundRuiz-Sarrió, J. E., Daviu, J. A. A., & Martis, C. S. (2024) · Sensors · doi:10.3390/s24216935 · Cited by 14
Gmati, B., Rhouma, A. B., Meddeb, H., & Khil, S. K. E. (2024) · World Electric Vehicle Journal · doi:10.3390/wevj15020053 · Cited by 14
A Few-Shot Open-Circuit Fault Diagnosis of F-Type Inverters Using CGAN-Based Vision Transformer
Mahmoud, M. S., Salem, A., Khang, H. V., & Robbersmyr, K. G. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3478378 · Cited by 16
“These fuses operate swiftly, avoiding additional computational delays, by quickly bypassing the fault effects and converting SC faults to OC faults [13].”
Navarro-Navarro, Á., Ruiz-Sarrio, J. E., Biot-Monterde, V., Daviu, J. A. A., Becker, V., & Urschel, S. (2023) · Machines · doi:10.3390/machines11020288 · Cited by 17
Time-Frequency Domain Lightweight Dual-Branch MSCFormer for PMSM ITSC Fault Diagnosis
Yu, H., Li, S., Xu, Y., Zhang, Z., Mu, H., & Han, W. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3579108 · Cited by 17
Overview of IoT Security Challenges and Sensors Specifications in PMSM for Elevator Applications
Vlachou, E. I., Vlachou, V. I., Efstathiou, D. E., & Karakatsanis, T. S. (2024) · Machines · doi:10.3390/machines12120839 · Cited by 13
Niu, F., Xu, M., Zhou, F., Huang, S., Xu, Z., Zhang, L., & Aggarwal, A. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3487628 · Cited by 13
Demirel, A., Keysan, O., El-Dalahmeh, M., & Al‐Greer, M. (2024) · Measurement · doi:10.1016/j.measurement.2024.114684 · Cited by 14
“In existing literature, many PMSM fault diagnosis techniques fail to address the potential for hardware implementation, often requiring additional hardware or expensive software [1].”
BackgroundMethodInfluentialZhao, Y., Zhang, S., Zhang, C., et al. (2024) · IEEE Access · doi:10.1109/access.2024.3351174 · Cited by 12
Li, Z., Wang, F., Xie, H., Ke, D., Ye, T., Davari, S. A., & Kennel, R. M. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3331580 · Cited by 13
“Implementing such techniques can increase service time and ensure system stability [5].”
BackgroundModeling, Control and Monitoring of Automotive Electric Drives
Dini, P., Saponara, S., Chakraborty, S., & Hegazy, O. (2025) · Electronics · doi:10.3390/electronics14193950 · Cited by 17
Zheng, B., Liu, B., Yan, J., Tang, M., Zanchetta, P., & Yu, H. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3599747 · Cited by 12
Zhan, H., Wu, L., Lyu, Z., Du, Y., & Duan, R. (2024) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2024.3428468 · Cited by 12
Yan, J., Wu, X., Zhu, Z. Q., & Liu, C. (2024) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2024.3397960 · Cited by 14
Moniruzzaman, M., Okilly, A. H., Choi, S., Baek, J., Mannan, T. I., & Islam, Z. (2024) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48139.2024.10509167 · Cited by 20
“In the data-driven paradigm, IGBT power modules are treated as black boxes, and system parameters can be identified through a model-free approach, eliminating the necessity for prior knowledge of specific IGBT devices [14-15].”
BackgroundChu, K. S. K., Chew, K. W., Chang, Y. C., & Morris, S. (2024) · World Electric Vehicle Journal · doi:10.3390/wevj15020071 · Cited by 16
Zhou, X., Hu, Q., Cui, P., Xu, X., & Mao, K. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3281683 · Cited by 11
“It is found that the residual magnitude varies with motor operation states [4] and it may deviate from zero without fault [33].”
BackgroundVlachou, V. I., & Karakatsanis, T. S. (2025) · Machines · doi:10.3390/machines13050427 · Cited by 11
“The collected data can then be processed using either traditional techniques, such as Fast Fourier Transform (FFT), Short-Time Fourier Transform (STFT), Continuous Wavelet Transform (CWT) [14], or more advanced methods based on machine-learning algorithms and multimodal data [15].”
Marcos-Andrade, D., Beltrán-Carbajal, F., Esquivel-Cruz, J. E., et al. (2024) · World Electric Vehicle Journal · doi:10.3390/wevj15040159 · Cited by 11
Singh, A., & Khosla, A. (2025) · Propulsion and Power Research · doi:10.1016/j.jppr.2025.06.001 · Cited by 10
Vlachou, V. I., Efstathiou, D. E., & Karakatsanis, T. S. (2024) · Machines · doi:10.3390/machines12080560 · Cited by 10
Diagnostics of Interturn Short Circuits in PMSMs With Online Fault Indicators Estimation
Zezula, L., Kozovský, M., & Bláha, P. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3363775 · Cited by 17
Pietrzak, P., Pietrzak, P., & Wolkiewicz, M. (2024) · Energies · doi:10.3390/en17020387 · Cited by 10
Self-citationPietrzak, P., & Wolkiewicz, M. (2024) · Power Electronics and Drives · doi:10.2478/pead-2024-0007 · Cited by 10
“Stator winging faults are highly destructive in nature (Orlowska-Kowalska et al., 2022).”
BackgroundSelf-citationXu, H., Liu, Z., Jiang, D., Qu, R., & Tian, J. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3595437 · Cited by 12
“This mechanistic similarity provides a theoretical foundation for extracting common knowledge across datasets and facilitating the reuse of maintenance knowledge [16].”
Speed Signature Analysis for Servo Motor Bearing Fault Detection Under Dynamic Load Conditions
Huang, X. S., Zhang, J., Wu, Y., Xu, Z., & Cheng, M. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3531376 · Cited by 11
“W ITH the rapid development of industrial automation and computer science, the online status monitoring of servo motorshasattractedmuchattentionfromvariousinstitutions[1], [2],[3].”
Walch, D., Blechinger, C., Schellenberger, M., Hofmann, M., Eckardt, B., & Lorentz, V. (2024) · Machines · doi:10.3390/machines12070468 · Cited by 10
Ewert, P., Wicher, B., & Pajchrowski, T. (2024) · Electronics · doi:10.3390/electronics13020441 · Cited by 14
Self-citationSuti, A., & Rito, G. D. (2024) · Actuators · doi:10.3390/act13010025 · Cited by 10
Detection of External Rotor PMSM Inter-Turn Short Circuit Fault using Extended Kalman Filter
Belkhadir, A., Pusca, R., Romary, R., Belkhayat, D., & Zidani, Y. (2023) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/sdemped54949.2023.10271465 · Cited by 13
Belkhadir, A., Pusca, R., Belkhayat, D., Romary, R., & Zidani, Y. (2023) · Energies · doi:10.3390/en16073198 · Cited by 13
Online Short-Circuit Fault Detector of the Induction Motor Winding Based on MRAS Technique
Benlaloui, I., Fezzani, A., Orłowska-Kowalska, T., Chrifi‐Alaoui, L., & Drid, S. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3508086 · Cited by 12
“Diagnostics based on circuit mathematical models use different estimators of motor state variables and parameters and is presently applied especially in fault-tolerant control (FTC) systems, where observers are used in online failure detection and compensation [4], [18].”
InfluentialSelf-citationAn Extremely Close Vibration Frequency Signal Recognition Using Deep Neural Networks
Jati, M. P., Luthfi, M. I., Yao, C.-K., Dehnaw, A. M., Manie, Y. C., & Peng, P. (2024) · Applied Sciences · doi:10.3390/app14072855 · Cited by 9
Zhan, H., Liu, W., Lyu, Z., Niu, S., Wu, L., & Chau, K. T. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3574542 · Cited by 10
“Torealizethe effective diagnosis of eccentricity fault, lots of methods have been proposed in academia and applied in industry [6], [7], [13], as shown in Fig.”
Morenas, J. D. L., Belmonte, L. M., & Morales, R. (2025) · Machines · doi:10.3390/machines13050357 · Cited by 13
Deep-Learning Techniques Applied for State-Variables Estimation of Two-Mass System
Kaczmarczyk, G., Stanisławski, R., & Kamiński, M. (2025) · Energies · doi:10.3390/en18030568 · Cited by 8
Kılıç, A., & Weiss, F. (2023) · Journal of the Brazilian Society of Mechanical Sciences and Engineering · doi:10.1007/s40430-023-04420-6 · Cited by 8
“Therefore, these PMSM faults must be considered safety critical [22]: Winding short circuit, Phase-to-phase short circuit, Interruption of a phase, Fig.”
BackgroundHalabi, L. M., Alsofyani, I. M., & Lee, K. (2023) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2023.3315273 · Cited by 8
“Other methods involve adding components to the original topology [43], [44], [45].”
MethodMargin-Maximized Hyperspace for Fault Detection and Prediction: A Case Study With an Elevator Door
Kim, M., Son, S., & Oh, K. (2023) · IEEE Access · doi:10.1109/access.2023.3330137 · Cited by 9
“Fault detection and diagnosis (FDD) on a variety of mechatronics systems, including motors [1], [2], [3], [4], [5], [6], [7], [8], wind turbines [9], [10], automobiles [11], gas turbines [12], [13], [14], and HVAC systems [15], [16], [17], [18] have been investigated worldwide because manufacturers…”
BackgroundLenz, R., Deutschmann, A., Kugi, A., & Kemmetmüller, W. (2024) · Control Engineering Practice · doi:10.1016/j.conengprac.2024.105924 · Cited by 12
Diagnosis of Stator Interturn Fault in SPMSM Using Machine Learning
Kapgate, B. A., & Praveen Kumar, N. (2023) · IEEE India Council International Conference (INDICON) · doi:10.1109/indicon59947.2023.10440789 · Cited by 7
“They can operate in both motoring and generating modes, making them ideal for applications that require energy recovery, such as regenerative braking [3], [4].”
BackgroundSkowron, M., Kowalski, C. T., & Orłowska-Kowalska, T. (2022) · Energies · doi:10.3390/en15197008 · Cited by 9
Self-citationKoutrakos, K., & Mitronikas, E. D. (2024) · Applied Sciences · doi:10.3390/app14104318 · Cited by 9
Fault Diagnosis in Electrical Machines for Traction Applications: Current Trends and Challenges
Pastura, M., & Zigliotto, M. (2024) · Energies · doi:10.3390/en17215440 · Cited by 10
Current- and Vibration-Based Detection of Misalignment Faults in Synchronous Reluctance Motors
Navarro-Navarro, Á., Biot-Monterde, V., Ruiz-Sarrio, J. E., & Daviu, J. A. A. (2025) · Machines · doi:10.3390/machines13040319 · Cited by 18
“These effects are closely related to the rotational speed of the motor [25].”
Rathor, K., Keerthika, V., Sunanda, K., et al. (2024) · doi:10.1109/iccds60734.2024.10560434 · Cited by 6
“Since PMSMs are increasingly used in safety-critical applications, this paper [11] discusses their monitoring and fault diagnostics in drives.”
BackgroundMahmoud, M. S., Salem, A., Khang, H. V., Robbersmyr, K. G., & Pomarnacki, R. (2023) · International Middle East Power Systems Conference (MEPCON) · doi:10.1109/mepcon58725.2023.10462369 · Cited by 6
“Hardware-based protection like fast-acting fuses are adopted due to their fast operation without additional computational delay, bypassing the fault effects and converting the SC faults to OC faults [24].”
BackgroundAdamczyk, M., & Orłowska-Kowalska, T. (2022) · Sensors · doi:10.3390/s22249813 · Cited by 6
Self-citationThapa, K. B., Korta, P., Toulabi, M. S., et al. (2022) · IEEE Industrial Electronics Society Annual On-Line Conference (ONCON) · doi:10.1109/oncon56984.2022.10126863 · Cited by 6
“Among various faults, the resistive unbalance fault in which the phase resistance is increased while the phase inductance remains constant, is a general fault that can appear in any power connection of electric machines in industries [2].”
BackgroundHuang, Y., Xie, Y., & Han, W. (2025) · Sensors · doi:10.3390/s25123623 · Cited by 7
“Research efforts primarily focus on developing advanced algorithms that adapt to the nonlinear behavior of PMSMs [7].”
Salman, M., Riccio, J., Khil, S. K. E., Zanchetta, P., & Boccaletti, C. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3577113 · Cited by 8
“Common fault types include electrical faults such as open and short circuits, which can occur in the motor windings or within the VSI [5].”
Inter-Turn Short Circuit Faults and Mitigation Measures for Dual-Three Phase Machines
Walch, D., Geiger, A., & Sültrop, C. (2024) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icem60801.2024.10700240 · Cited by 7
“Inter-turn short circuits are a common cause of failure in electrical machines [13].”
BackgroundEnhancing Speed Estimation in DC Motors using the Kalman Filter Method: A Comprehensive Analysis
Setiawan, M. H., Ma’arif, A., Rekik, C., et al. (2024) · Jurnal Ilmiah Teknik Elektro Komputer dan Informatika · doi:10.26555/jiteki.v10i1.26591 · Cited by 5
Skowron, M., Jamshidpour, E., Teler, K., Orłowska-Kowalska, T., & Haghgooei, P. (2023) · IEEE Transportation Electrification Conference and Expo, Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itecasia-pacific59272.2023.10372315 · Cited by 6
Self-citationReviewing Fault Diagnosis Methods in Electric Drives: Power Subsystem and Electrical Machine
Demidova, G., Chen, H., Li, Y., Lukichev, D. V., & Anuchin, A. (2023) · International Siberian workshops and tutorials on electron devices and materials · doi:10.1109/edm58354.2023.10225122 · Cited by 5
“Teresa OrlowskaKowalska has made a significant contribution to the field of electrical drive fault diagnosis systems review through her extensive work spanning several decades, which has been reviewed in [1].”
BackgroundHusnayain, F., Noguchi, T., Akaki, R., et al. (2023) · Energies · doi:10.3390/en16124712 · Cited by 5
Metadata
- Authors
- Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T.
- Affiliations
- Department of Electrical Machines, Drives and Measurements, Wrocław University of Science and Technology, Wrocław, Poland
- Wrocław University of Science and Technology (PL)
- ORCID
- Venue
- IEEE Access
- Published
- 2022
- Volume
- 10
- Pages
- 59979-60024
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W4285271556
- Semantic Scholar
- dc069ddc2dd7fed25b6db8df368599dab4ad9d8b
- Cited by
- 328
- References
- 335
- Citations by year
- 2026: 72 · 2025: 112 · 2024: 81 · 2023: 52 · 2022: 11
- FWCI
- 21.95
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- IEEE Access (publishedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- National Science Centre Poland (2017/27/B/ST7/00816)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Keywords
- permanent magnet synchronous motor, fault diagnosis, fault-tolerant control, motor drives, stator winding faults, bearing defects, rotor faults, power converter faults, sensor faults, artificial neural networks, safety-critical systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-06, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-06 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.