The DOI matches its Crossref record; 341 of the 341 references it cites were found in a registry or an index; 24 of the 225 sources its claims cite were checked for support.
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Open accessAbstract
The issues of monitoring and fault diagnosis of drives with permanent magnet synchronous motors (PMSM) are currently very topical due to the increasing use of these drives in safety-critical devices. Every year, more and more articles on this subject are published. Therefore, the aim of this article is to update the overview of diagnostic methods and techniques for PMSM drives. Each of the main chapters of the article focuses on a specific element of the drive system (motor, power converter, measuring sensors), with particular emphasis on the components of the motor (stator windings, magnets, bearings, rotor). The main sections on PMSM fault diagnosis are divided according to the type of methods used to obtain the symptoms of the damage. In addition, a review of methods using the analysis of control structure signals for the diagnosis of damage to a vector-controlled motor is presented, as well as the latest achievements of researchers in the field of shallow and deep neural networks for the detection and classification of PMSM drives failures. Based on the presented literature analyses, some development trends and challenges related to the development of diagnostics and fault-tolerant control of PMSM drives are discussed in the conclusion part.
Overview
CoChat Summary
TL;DR
This IEEE Access review surveys fault diagnosis and fault-tolerant control (FTC) for permanent magnet synchronous motor (PMSM) drives, covering motor, converter, and sensor faults and methods based on signal analysis, mathematical models, control-structure signals, and artificial intelligence. It synthesizes the literature and identifies future challenges in transient diagnostics, multiple-fault diagnosis, AI/deep learning, hardware implementation, and prognostics.
Key findings
- The review classifies PMSM faults into electrical, magnetic, and mechanical types and cites component failure statistics: stator winding failures account for 36–66% of AC motor breakdowns, bearing faults 13–41%, bearing failures about 40–50% of all electric motor failures, power semiconductor device damages about 35% of all adjustable-speed-drive faults, DC-link capacitors about 30% of frequency-converter failures, and transistor failures 12% of all electric-drive failures.
- Signal-analysis methods dominate PMSM diagnostics: FFT/MCSA/EPVA are widely used for inter-turn short circuits (ITSCs) and demagnetization, while time-frequency methods such as STFT, WT, WVD, CWD, and HHT address non-stationary conditions; control-structure signals can enable sensorless diagnostics but are sensitive to controller bandwidth.
- AI-based diagnostics are reviewed: shallow neural networks (MLP, RBF, SOM, PNN, BNN) require preprocessing, while deep networks (CNN, LSTM) allow direct feature extraction; Table IX reports literature classification accuracies such as MLP 99.02% on vibrations, CNN 99.38% on flux, CNN 99.28% on stator currents, and SOM 93.00% on vibrations.
- FTC is divided into passive and active approaches; active FTC uses fault detection and diagnosis with reconfiguration or compensation, speed-sensor FTC relies on sensorless estimators, current-sensor FTC uses observers, and inverter FTC often uses hardware redundancy; ITSC-FTC strategies remain relatively rare and mostly target torque-ripple or copper-loss reduction, with few limiting short-circuit current.
Methods
- Design: state-of-the-art review/survey; it compares itself with existing PMSM diagnostic surveys in Table I and organizes the literature by fault location and diagnostic method.
- Data or sample: no primary experimental sample; it analyzes published methods and presents tabular summaries (Tables II–X) for ITSC, demagnetization, bearing, eccentricity, unbalance, misalignment, converter, sensor faults, AI methods, and FTC.
- Main analysis: categorizes methods into frequency-domain, time-frequency, time-domain/statistical, model-based, control-structure-signal, and AI-based approaches, discussing advantages, disadvantages, and future trends.
Limitations
- Paper-stated: future challenges include diagnostics during transients, hardware implementation, failure prediction/prognostics, data storage and cloud transfer, multiple-fault diagnosis, AI/deep-learning development for PMSM drives, transfer learning, and real-time fault detection.
- Paper-stated: many PMSM fault diagnosis methods lack hardware implementation; deep neural networks are limited by structural complexity; few papers address ITSC-FTC and fault-current mitigation; control-structure-based mechanical fault diagnosis needs further work.
- Evident from the text: as a review, it reports no new experimental validation; some cited methods are simulation-only or inconclusive (e.g., DWT+NN bearing diagnosis in DTC is described as simulation-only and rather inconclusive), and the AI accuracy table is literature-derived rather than a controlled benchmark.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures

















Verification
Claims the paper makes
19 Valid · 20 Not valid · 149 Not checked · 149 Own results and interpretations
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“Greater sensitivity of this component to the stator winding fault compared to the FFT of the stator phase current is also emphasized.”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > A. FREQUENCY DOMAIN METHODS
What the sources say
- Disputedcites [43] sourceExperimental — accuracy not yet measured
Section 5 (page not provided) compares the fault indicators and identifies the 3fs component in the FFT spectrum of the stator phase current—not the 2fs component—as the most sensitive across the tested load-torque range. The Conclusions likewise describe both indicators as sensitive, without saying that 2fs is more sensitive. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
- Not matchedcites [45]- [47]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“According to [20], the greatest and most obvious increase in the case of this fault is the increase in the amplitude of the 3fs component, which has also been confirmed by the results presented by the authors in [42] and [43].”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > A. FREQUENCY DOMAIN METHODS
What the sources say
- Partly supportedcites [20] sourceExperimental — accuracy not yet measured
Section 3.2.1 (Frequency Domain Methods) says that for an inter-turn short circuit, the most obvious feature is an increase in the third-harmonic amplitude, corresponding to 3fs. It does not establish that this is the greatest increase in magnitude among the components. (LLM, conf=0.83)
- Partly supportedcites [42] sourceExperimental — accuracy not yet measured
Section 6 (Conclusions; page not available in our copy) reports that inter-turn short circuits increase the stator current’s 3fs harmonic and that its amplitude is much greater under field-oriented control than under scalar control. It does not establish that this is the greatest increase among fault-related components; the claim also omits the control-structure qualification. (LLM, conf=0.83)
- Supportedcites [43] source
Section 6 (Conclusions; page not provided) calls the increase in the 3fs component’s amplitude the most significant symptom of stator-winding damage. Section 4.1 also reports a large increase in that component after an interturn short circuit. (LLM, conf=0.94)
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“In all of these papers, the Authors conclude that the increase of the 2fs component amplitude in the stator phase current space vector module spectrum is a symptom of a stator winding fault.”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > A. FREQUENCY DOMAIN METHODS
What the sources say
- Supportedcites [43] source
Section 2.2 states that, following an inter-turn short-circuit, the 2fs component increases in the FFT spectrum of the stator phase current space vector magnitude. This directly supports the attributed symptom of a stator winding fault. (LLM, conf=0.93)
- Not matchedcites [45]- [47]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
boostedstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“The limitation of this approach is mentioned in [60] to measure the ZSVC, the access to the neutral point of the stator winding is needed.”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > A. FREQUENCY DOMAIN METHODS
What the sources say
- Supportedcites [60] source
The Conclusion explicitly states that an accessible neutral point of the stator windings is needed to measure the ZSVC. It also notes that this condition is met in a fault-tolerant PMSM drive system. (LLM, conf=0.95)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“The basic diagnostic signals in eccentricity diagnosis are: stator current [135], [143]- [146], [150], [151], [156]- [159], [161], [162], mechanical vibrations [149], [155], [156], noise [155], an airgap search coil voltage [149], [152], [156], [160], stator voltage [159], speed [159], load torque [159], d-axis stator inductance Ld [147], [148], BEMF [160] and unbalanced magnetic pull [153], [154]”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > B. ECCENTRICITY FAULTS
What the sources say
- Not checked — no full text of the sourcecites [135] source
- Not matchedcites [143]-[146]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Supportedcites [150] source
This source is cited within the stator-current group of references, not for the entire list of signals. The Introduction identifies stator current as a prevalent monitored signal for motor fault detection, and Section 5 analyzes it for static eccentricity diagnosis in LSPMSMs. Page numbers are not available in our copy. (LLM, conf=0.93)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
150 more claims · 5 with their cited sources checked
Create a free account to see all 337 claims and to verify the 1 reference still open.
- It may state two separate claims as one. 113
- Probably not a substantial claim. 91
- The quote only partly states this claim. 3
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > C. DEEP NEURAL NETWORKS APPLICATION IN PMSM DRIVES
“The possibility of direct extraction of the input signal features in the diagnostics of PMSM stator windings faults has been described in [220], [222], [223], [229], [237].”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > B. SHALLOW NEURAL NETWORKS APPLICATION IN PMSM DRIVES
“[237] + + CNN FFT IsABC”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > TABLE I COMPARISON OF THIS PAPER WITH EXISTING SURVEYS AND REVIEW PAPERS ON DIAGNOSTICS OF PMSM DRIVES
“[15] 2015 125 (120) 1997-2016”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > References
“15. M. Cheng, J. Hang, and J.Zhang, "Overview of fault diagnosis theory and method for permanent magnet machine," Chinese Journal of Electrical Eng., vol. 1 no. 1, pp. 21-36, 2015..”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > IX. FAULT DETECTION OF PMSM DRIVE COMPONENTS AND FAULT-TOLERANT CONTROL A. FREQUENCY CONVERTER FAULTS
“The voltage-based method was also applied in [274] for open switch fault diagnosis in a voltage-oriented controlled AC/DC line side converter.”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > References
“274. M. Bourogaoui, H. B. A. Sethom, and I. S. Belkhodja. "Speed/position sensor fault tolerant control in adjustable speed drives -a review." ISA Transactions, vol. 64, pp. 269-284, 2016.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > B. SHALLOW NEURAL NETWORKS APPLICATION IN PMSM DRIVES
“[216] + MLP DIRECT IsABC”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > C. DEEP NEURAL NETWORKS APPLICATION IN PMSM DRIVES
“[216] + + MLP 98,50% (FFT) IsABC + Te + + MLP 96,10% (STAT) IsABC + Te”
Citations
Cites
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
A review of induction motors signature analysis as a medium for faults detection
El Hachemi Benbouzid, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873206 · Cited by 1,602
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278 · cited 1×
“According to [238], [239], power semiconductor device damages account for approximately 35% of all ASD faults.”
BackgroundAdvances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140 · cited 1×
“Additionally, the FFT can even mask components that appear at a given moment of time but are of very short duration [10], [32].”
BackgroundA Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
A High-Speed Sliding-Mode Observer for the Sensorless Speed Control of a PMSM
Kim, H., Son, J., & Lee, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2098357 · Cited by 733 · cited 3×
“In [283] the SMO was developed with sign-type switching function replaced by a sigmoid function with some boundary”
BackgroundMethodWelchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724 · cited 2×
“A detailed overview of fault-tolerant inverter topologies is presented in [307], [308].”
BackgroundNew Sliding-Mode Observer for Position Sensorless Control of Permanent-Magnet Synchronous Motor
Qiao, Z., Shi, T., Wang, Y., Yan, Y., Xia, C., & He, X. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2206359 · Cited by 602 · cited 2×
“These could be: extended observer [279], SMO [280], [283], [284] or super-twisting sliding mode observer (ST-SMO) [285], MRAS estimator [281], KF [282]”
BackgroundMethodTrends in Fault Diagnosis for Electrical Machines: A Review of Diagnostic Techniques
Henao, H., Capolino, G.-A., Fernandez-Cabanas, M., Filippetti, F., Bruzzese, C., Strangas, E., Pusca, R., Estima, J., Riera-Guasp, M., & Hedayati-Kia, S. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2287651 · Cited by 602 · cited 3×
“The popularity of this method is related to its simplicity, low cost and online machine state monitoring capabilities [11].”
MethodReport of Large Motor Reliability Survey of Industrial and Commercial Installations, Part I
(1985) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1985.349532 · Cited by 602
Survey on Fault-Tolerant Techniques for Power Electronic Converters
Zhang, W., Xu, D., Enjeti, P. N., Li, H., Hawke, J. T., & Krishnamoorthy, H. S. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2304561 · Cited by 587 · cited 2×
“A detailed overview of fault-tolerant inverter topologies is presented in [307], [308].”
BackgroundRiera-Guasp, M., Antonino-Daviu, J. A., & Capolino, G.-A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2375853 · Cited by 573 · cited 1×
“Over the last 30 years, many review articles on the FDD of electrical machines have been published, however, most of them concern the induction motors (IM) [7]-[13], due to the fact that, until recently, they accounted for more than 90% of all electric motors installed in industry [1]-[3].”
BackgroundRecent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544 · cited 2×
“Other time-frequency signal analysis methods applied in the diagnostics use a quadratic time-frequency distribution [19], [27], [29], [32].”
BackgroundMethodReview of condition monitoring of rotating electrical machines
Tavner, P. J. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070280 · Cited by 531
Electric and Hybrid Vehicles: Design Fundamentals
Husain, I. (2021) · Cited by 517
Hybrid Electric Vehicles: Architecture and Motor Drives
Ehsani, M., Gao, Y., & Miller, J. M. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2007.892492 · Cited by 490
A Data-Driven Fault Diagnosis Methodology in Three-Phase Inverters for PMSM Drive Systems
Cai, B., Zhao, Y., Liu, H., & Xie, M. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2608842 · Cited by 471 · cited 1×
“[66] Line-to-line voltage FFT+PCA Eigenvalues of line-toline voltage components EV, ON, RL, RS SC for FFT”
BackgroundFault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441 · cited 4×
“The literature review shows that the open-circuit FDD methods may be classified as current signatures [254]–[260], [267]-[272] and voltage signatures based methods [261]– [264], [273].”
BackgroundMethodInfluentialEstima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377 · cited 5×
“Because the open-circuit fault causes an erroneous value of the output voltage, an increase in current harmonics and torque pulsations, its diagnosis is of research interest so that the PM machine can safely operate in critical systems application [254].”
BackgroundMethodInfluentialFault-tolerant permanent magnet machinedrives
Mecrow, B. C., Jack, A. G., Haylock, J. A., & Coles, J. (1996) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19960796 · Cited by 376 · cited 1×
“This concept appeared in the mid-1990s [311] and since then intensive research has been carried out on such design aspects of PMFT machines, such as:”
BackgroundFoo, G. H. B., Zhang, X., & Vilathgamuwa, D. M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2244537 · Cited by 369
Induction machine drive condition monitoring and diagnostic research—a survey
Singh, G. K., & Ahmed Saleh Al Kazzaz, S. (2003) · Electric Power Systems Research · doi:10.1016/s0378-7796(02)00172-4 · Cited by 362
Da, Y., Shi, X., & Krishnamurthy, M. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227808 · Cited by 303 · cited 3×
“[91]-[93] Axial flux FFT PDF, UDF, ON, HS, NAOF SC, INV or ACR”
BackgroundMethodJlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284 · cited 2×
“Another way to deal with switch short-circuit faults is the application of fast fuses [248].”
BackgroundModeling of Surface-Mounted Permanent Magnet Synchronous Motors With Stator Winding Interturn Faults
Romeral, L., Urresty, J. C., Riba Ruiz, J.-R., & Garcia Espinosa, A. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2062480 · Cited by 282 · cited 4×
“The models presented in the literature are described by differential equations, in a three-phase system A-B-C [42], [47], [83], [195], [196], [198], in a synchronous reference frame d-q for 3-phase motors [44], [72], [193], [194], [197], and also for multi-phase motors [213].”
MethodInfluentialFault-Tolerant Voltage Source Inverter for Permanent Magnet Drives
Errabelli, R. R., & Mutschler, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2135866 · Cited by 278 · cited 2×
“According to [238], [239], power semiconductor device damages account for approximately 35% of all ASD faults.”
BackgroundDetecting Rotor Faults in Low Power Permanent Magnet Synchronous Machines
le Roux, W., Harley, R. G., & Habetler, T. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886620 · Cited by 274 · cited 1×
“However, the visibility of this symptom is strongly dependent on the configuration of the winding, and sometimes even in the case of demagnetization there are no harmonics or subharmonics other than those that occur in a healthy motor due to the natural existing asymmetries of the machine [19], [29], [84], [85].”
BackgroundEbrahimi, B. M., Javan Roshtkhari, M., Faiz, J., & Khatami, S. V. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2263777 · Cited by 271
Reliability Improvement of a T-Type Three-Level Inverter With Fault-Tolerant Control Strategy
Choi, U.-M., Blaabjerg, F., & Lee, K.-B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2325891 · Cited by 258 · cited 1×
“However, it has been shown in [310], that also much less complicated solutions are possible”
BackgroundGuzman, H., Duran, M. J., Barrero, F., Bogado, B., & Toral, S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2289882 · Cited by 258 · cited 1×
“Chapter IXB, in a part concerning CS fault detection presents, among others the possibilities of using model-based stator current estimators in CS-FDD systems [317]-[322].”
MethodFPGA-Based Real-Time Power Converter Failure Diagnosis for Wind Energy Conversion Systems
Karimi, S., Gaillard, A., Poure, P., & Saadate, S. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2005244 · Cited by 245
Espinosa, A. G., Rosero, J. A., Cusido, J., Romeral, L., & Ortega, J. A. (2010) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2009.2037922 · Cited by 243 · cited 2×
“In conference papers [109], [110] and following articles [111], [112] the HHT was applied to stator current signal obtained from FEM simulation model of the PMSM with DF under different speed and load torque values.”
BackgroundMethodJeong, Y.-S., Sul, S.-K., Schulz, S. E., & Patel, N. R. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.840947 · Cited by 240 · cited 3×
“In [276] the simple method based on calculated power balance was used.”
BackgroundMethodInfluentialSmet, V., Forest, F., Huselstein, J.-J., Rashed, A., & Richardeau, F. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2196894 · Cited by 232 · cited 1×
“its frequent overloads [19], [243], [244].”
Ruiz, J.-R. R., Rosero, J. A., Espinosa, A. G., & Romeral, L. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2015942 · Cited by 231 · cited 1×
“In [102] and [103] the DF is analyzed through stator currents (obtained from FEM simulations and experimental tests) at different speeds using CWT and DWT.”
MethodFault-tolerant control in variable speed drives: a survey
Campos-Delgado, D. U., Espinoza-Trejo, D. R., & Palacios, E. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070203 · Cited by 228 · cited 1×
“The main problem for model-based techniques is their robustness to system parameter changes and the threshold choice for the particular failure types in a given system [275].”
BackgroundCurrent Residual Vector-Based Open-Switch Fault Diagnosis of Inverters in PMSM Drive Systems
An, Q.-T., Sun, L., & Sun, L.-Z. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2360834 · Cited by 226 · cited 2×
“These methods can be also classified as modelfree [184], [254]-[257], [261]-[263], [267]-[273] and modelbased methods [252], [258]-[260], [264], [265].”
MethodAnalysis of Permanent Magnet Synchronous Motor Fault Diagnosis Based on Learning
Kao, I.-H., Wang, W.-J., Lai, Y.-H., & Perng, J.-W. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2847800 · Cited by 221
Hong, J., Park, S., Hyun, D., Kang, T.-J., Lee, S. B., Kral, C., & Haumer, A. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2191253 · Cited by 219 · cited 1×
“damaging vibrations, and thus affects bearing wear and rotor damage [19], [37].”
BackgroundHang, J., Zhang, J., Cheng, M., & Huang, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2388493 · Cited by 218
Acquisition of Position Error and Magnet Polarity for Sensorless Control of PM Synchronous Machines
Holtz, J. (2008) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2008.921418 · Cited by 217 · cited 1×
“[330], [331] and HF signal injection, e.”
PWM-VSI Fault Diagnosis for a PMSM Drive Based on the Fuzzy Logic Approach
Yan, H., Xu, Y., Cai, F., Zhang, H., Zhao, W., & Gerada, C. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2814615 · Cited by 216
A Model-Based Strategy for Interturn Short-Circuit Fault Diagnosis in PMSM
Mazzoletti, M. A., Bossio, G. R., De Angelo, C. H., & Espinoza-Trejo, D. R. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2688973 · Cited by 214 · cited 1×
“A state observer for stator current estimation of PMSM is proposed in [192] for ITSC fault detection.”
MethodRosero, J. A., Romeral, L., Ortega, J. A., & Rosero, E. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2011580 · Cited by 214 · cited 3×
“detection based on the EMD and WVD is proposed in [78].”
MethodInfluentialMendes, A. M. S., & Marques Cardoso, A. J. (2003) · IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272) · doi:10.1109/iemdc.1999.769220 · Cited by 213 · cited 2×
“In [249] the motor supply current PVA is proposed for the VSI short-circuit and open switch fault diagnosis in variable speed AC drives.”
BackgroundMethodJlassi, I., Estima, J. O., Khojet El Khil, S., Mrabet Bellaaj, N., & Marques Cardoso, A. J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2342506 · Cited by 212 · cited 1×
“This observation provides sufficient information to detect faulty transistors in power converters [269], [270].”
BackgroundEbrahimi, B. M., & Faiz, J. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2050496 · Cited by 208
Faiz, J., & Mazaheri-Tehrani, E. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2608950 · Cited by 207 · cited 9×
“The PM demagnetization can be uniform over all poles or partial over certain region or poles [15], [18], [29], [32].”
BackgroundMethodInfluentialFault-tolerant permanent magnet machines: a review
El-Refaie, A. M. (2011) · IET Electric Power Applications · doi:10.1049/iet-epa.2009.0117 · Cited by 207 · cited 1×
“In [312] a detailed review and summary on the PMFT machine design is presented, with an emphasis on limiting the short-circuit current.”
BackgroundPiippo, A., Hinkkanen, M., & Luomi, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911949 · Cited by 201 · cited 2×
“VOLUME XX, 2017 45 adaptive system (MRAS) concept, is proposed in [281].”
BackgroundFoo, G., & Rahman, M. F. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030815 · Cited by 198 · cited 2×
“Classical speed/position observers based on stator flux estimation, including extended observer [279] or sliding mode observer (SMO) [280], can be used for speed residuum generation.”
BackgroundMethodEasy and Fast Sensor Fault Detection and Isolation Algorithm for Electrical Drives
Berriri, H., Naouar, M. W., & Slama-Belkhodja, I. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2140333 · Cited by 197 · cited 1×
“In [302] another FDD method for CSs using the parity space approach is introduced, however, the procedure of the design is mathematically complicated.”
MethodFaults and Diagnosis Methods of Permanent Magnet Synchronous Motors: A Review
Chen, Y., Liang, S., Li, W., Liang, H., & Wang, C. (2019) · Applied Sciences · doi:10.3390/app9102116 · Cited by 194
Choi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
Foo, G. H. B., & Rahman, M. F. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2036354 · Cited by 190 · cited 19×
“For more information, see https://creativecommons.org/licenses/by-nc-nd/4.0/ VOLUME XX, 2017 45 SMO is utilized to estimate the rotor position/speed using the restructured current only for a single phase CS fault.”
BackgroundMethodInfluentialPu, X.-S., Nguyen, T. H., Lee, D.-C., Lee, K.-B., & Kim, J.-M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2218561 · Cited by 189
Kim, K.-H. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2060463 · Cited by 184 · cited 5×
“In [38] the component has been used in order to diagnose the ITSC fault.”
BackgroundMethodInfluentialUrresty, J.-C., Riba, J.-R., Delgado, M., & Romeral, L. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2011.2176127 · Cited by 181 · cited 3×
“For this reason, studies of different FIs were analyzed, namely ZSCC/ZSVC [87], [89], [90].”
BackgroundMethodSarikhani, A., & Mohammed, O. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222857 · Cited by 177 · cited 3×
“[81] BEMF Residual analysis FI based on the difference between the estimated and reference BEMF EV, ON, TC, RL, RS The estimation of the BEMF is necessary”
MethodInfluentialTorregrossa, D., Khoobroo, A., & Fahimi, B. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2151810 · Cited by 169 · cited 3×
“and static eccentricity based on spectrum analysis in [100].”
BackgroundMethodFreire, N. M. A., Estima, J. O., & Cardoso, A. J. M. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2279383 · Cited by 167 · cited 4×
“The literature review shows that the open-circuit FDD methods may be classified as current signatures [254]–[260], [267]-[272] and voltage signatures based methods [261]– [264], [273].”
BackgroundMethodInfluentialUrresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2198077 · Cited by 164 · cited 1×
“The interesting approach is presented in [63] where the novel VKF-OT algorithm is introduced and applied to track the 3th harmonic of stator phase current and first one of the ZSVC for on-line detection of this failure.”
MethodRajagopalan, S., Roux, W. L., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904183 · Cited by 164 · cited 3×
“However, the visibility of this symptom is strongly dependent on the configuration of the winding, and sometimes even in the case of demagnetization there are no harmonics or subharmonics other than those that occur in a healthy motor due to the natural existing asymmetries of the machine [19], [29], [84], [85].”
BackgroundKhan, M., & Rahman, M. A. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004662 · Cited by 163 · cited 1×
“[71] WPT Second level approximates and details EV, ON, TC, RL, RS SC”
BackgroundA Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. (2008) · 2008 IEEE Industry Applications Society Annual Meeting · doi:10.1109/08ias.2008.349 · Cited by 160
Hang, J., Zhang, J., Xia, M., Ding, S., & Hua, W. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2953269 · Cited by 159
Haddad, R. Z., & Strangas, E. G. (2016) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2016.2558183 · Cited by 158 · cited 9×
“The usage of FFT analysis requires a compromise between the precision of the assessment of damage symptoms and the minimum computational effort [86], [88].”
BackgroundMethodInfluentialDynamic Permanent Magnet Flux Estimation of Permanent Magnet Synchronous Machines
Xiao, X., Chen, C., & Zhang, M. (2010) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2010.2041435 · Cited by 157 · cited 2×
“PARAMETER AND STATE OBSERVERS IN MOTOR DIAGNOSTICS Among the methods that use parameter estimators to detect PMSM motor failures, extended Kalman filters (EKF) are the most frequently used – to diagnose ITSC faults [188], [189], open phase failure [190] and demagnetization failure [191].”
MethodDesign of a Fault-Tolerant Controller Based on Observers for a PMSM Drive
Akrad, A., Hilairet, M., & Diallo, D. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2050756 · Cited by 155 · cited 1×
“Some authors propose the use of double software redundancy, as in [336].”
BackgroundLee, H., Jeong, H., Koo, G., Ban, J., & Kim, S. W. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2978690 · Cited by 153
A Simple Offline Technique for Evaluating the Condition of Aluminum–Electrolytic–Capacitors
Amaral, A. M. R., & Cardoso, A. J. M. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2022077 · Cited by 152 · cited 2×
“[242], [240] ESR calculation off-line Capacitor model Hardware measurement”
MethodA Back-emf Based Method to Detect Magnet Failures in PMSMs
Urresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2207731 · Cited by 151 · cited 1×
“The use of BEMF analysis is characterized by the lack of robustness to temperature changes of PMs [3], but the method is simple to implement [29], [95].”
MethodModeling and Control of Three-Phase PMSMs Under Open-Phase Fault
Gaeta, A., Scelba, G., & Consoli, A. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2228614 · Cited by 151
Discernment of Broken Magnet and Static Eccentricity Faults in Permanent Magnet Synchronous Motors
Goktas, T., Zafarani, M., & Akin, B. (2016) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2015.2512602 · Cited by 150 · cited 2×
“using bearings with off-center bushings [142], [144], [151], [156]-[158], shims mounted in the bearing housing [145] or on the motor shaft [147], [148], by modelling misalignment [159], by moving the rotor relative to the stator [153], [154], [160] or by eccentric shaft housings [152].”
MethodWang, B., Wang, J., Griffo, A., & Sen, B. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2793188 · Cited by 150
Strangas, E. G., Aviyente, S., & Zaidi, S. S. H. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007529 · Cited by 148 · cited 3×
“[5], [67] Stator current in qaxis STFT The first 31 harmonics EV, ON, RL, RS, TC, FL TR, stator current in q-axis has to be calculated”
BackgroundResultDiagnosis of Open-Switch and Current Sensor Faults in PMSM Drives Through Stator Current Analysis
Khojet El Khil, S., Jlassi, I., Marques Cardoso, A. J., Estima, J. O., & Mrabet-Bellaaj, N. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2930592 · Cited by 147
Performance of diagnosis methods for IGBT open circuit faults in voltage source active rectifiers
Rothenhagen, K., & Fuchs, F. W. (2004) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2004.1354769 · Cited by 146 · cited 2×
“The literature review shows that the open-circuit FDD methods may be classified as current signatures [254]–[260], [267]-[272] and voltage signatures based methods [261]– [264], [273].”
BackgroundMethodZanardelli, W. G., Strangas, E. G., & Aviyente, S. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900446 · Cited by 145 · cited 3×
“However, in [67] the significant disadvantage of this method is mentioned.”
BackgroundMethodLin, F.-J., Hung, Y.-C., & Tsai, M.-T. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2238877 · Cited by 145 · cited 2×
“Different control strategies were used including simple reconfiguration of the controller input and outputs [315], sliding-mode controller (SMC) [316] or MPC [317]-[319].”
MethodMinimum-Voltage Vector Injection Method for Sensorless Control of PMSM for Low-Speed Operations
Xie, G., Lu, K., Dwivedi, S. K., et al. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2426200 · Cited by 145 · cited 1×
“Moreover, speed estimation methods with increased accuracy in the range of low speeds, which combine classical observers with the HF injection methods [334], [335] can be used in FTC strategies.”
MethodDetection of Rotor Faults in Brushless DC Motors Operating Under Nonstationary Conditions
Rajagopalan, S., Aller, J. M., Restrepo, J. A., Habetler, T. G., & Harley, R. G. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.882613 · Cited by 143 · cited 29×
“In [67] the STFT based method of detection of electrical and mechanical faults of permanent magnet AC drives is discussed in detail and compared with wavelet analysis.”
BackgroundMethodInfluentialMwasilu, F. A., & Jung, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2495240 · Cited by 143
A Signal-Based Fault Detection and Tolerance Control Method of Current Sensor for PMSM Drive
Wu, C., Guo, C., Xie, Z., Ni, F., & Liu, H. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2813991 · Cited by 143
A review of induction motors signature analysis as a medium for faults detection
Benbouzid, M. (2002) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.1998.724016 · Cited by 142
Robust Sensors-Fault-Tolerance With Sliding Mode Estimation and Control for PMSM Drives
Kommuri, S. K., Lee, S. B., & Veluvolu, K. C. (2018) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2783888 · Cited by 140 · cited 1×
“A model reference adaptive observer to estimate the phase current of PMSM by using the information of position, speed, and voltage in α-β frame was introduced in [293], whereas a SMOs were suggested to diagnose the CS faults of PMSM drive in [294] and [295].”
MethodCurrent-Based Open-Circuit Fault Diagnosis for PMSM Drives With Model Predictive Control
Huang, W., Du, J., Hua, W., Lu, W., Bi, K., Zhu, Y., & Fan, Q. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3061448 · Cited by 140
Salehifar, M., Arashloo, R. S., Moreno‐Eguilaz, M., Sala, V., & Romeral, L. (2014) · IET Power Electronics · doi:10.1049/iet-pel.2013.0949 · Cited by 139 · cited 3×
“[258] IGBT Correlation of current residuum”
MethodAubert, B., Régnier, J., Caux, S., & Aléjo, D. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2348934 · Cited by 137
Data-driven early fault diagnostic methodology of permanent magnet synchronous motor
Cai, B., Hao, K., Wang, Z., Yang, C., Kong, X., Liu, Z., Ji, R., & Liu, Y. (2021) · Expert Systems with Applications · doi:10.1016/j.eswa.2021.115000 · Cited by 136
Mbo'o, C. P., & Hameyer, K. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2581139 · Cited by 135 · cited 5×
“[116], [131], [132], [135]-[137] Stator current FFT fb =fs±kfu fu – characteristic failure frequency of the bearing k=1,2,3.”
BackgroundMethodInfluentialDynamic Modeling and Control for SPMSMs With Internal Turn Short Fault
Jeong, I., Hyon, B. J., & Nam, K. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2222049 · Cited by 130 · cited 3×
“34 VOLUME XX, 2017 strategies presented in [324]-[326] concern mainly the reduction of the electromagnetic torque ripple or copper losses, but they do not limit the value of the short-circuit current, which is dangerous for the machine.”
BackgroundMethodA Comprehensive Analysis of Short-Circuit Current Behavior in PMSM Interturn Short-Circuit Faults
Yuan, Q., Bostancı, E., Gurusamy, V., & Akin, B. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2809668 · Cited by 129
Moon, S., Jeong, H., Lee, H., & Kim, S. W. (2018) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2017.2726142 · Cited by 123
Comprehensive Analysis of Magnet Defect Fault Monitoring Through Leakage Flux
Göktaş, T., Zafarani, M., Lee, K. W., Akin, B., & Sculley, T. L. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2016.2617318 · Cited by 122 · cited 2×
“In the case of stray flux measurement it has been shown in [93] that PM demagnetization can be detected through stray flux analysis similarly to wound rotor synchronous machines by using both time and frequency analysis.”
MethodDemagnetization Fault Indexes in Permanent Magnet Synchronous Motors—An Overview
Faiz, J., & Nejadi-Koti, H. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2015.2480379 · Cited by 119 · cited 3×
“The source of the PM temperature increase is the operation of the motor with a high load torque in difficult environmental conditions, but also damage to the stator winding in the form of ITSCs [15], [19], [20], [28]-[30], [32].”
BackgroundPark, Y., Fernandez, D., Lee, S. B., Hyun, D., Jeong, M., Kommuri, S. K., Cho, C., Diaz Reigosa, D., & Briz, F. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2886772 · Cited by 116 · cited 4×
“The eccentricity is most often modelled using FEM models [142]-”
BackgroundMethodInfluentialSeverity Estimation of Interturn Short Circuit Fault for PMSM
Yuan, Q., Bostancı, E., Zafarani, M., & Akin, B. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2879281 · Cited by 116
A New Approach for Current Sensor Fault Diagnosis in PMSG Drives for Wind Energy Conversion Systems
Freire, N. M. A., Estima, J. O., & Cardoso, A. J. M. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2271992 · Cited by 115
Skowron, M., Orłowska-Kowalska, T., & Kowalski, C. T. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3146557 · Cited by 113
Self-citationANN based fault diagnosis of permanent magnet synchronous motor under stator winding shorted turn
Moosavi, S. S., Djerdir, A., Ait-Amirat, Y., & Khaburi, D. A. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2015.03.024 · Cited by 112 · cited 11×
“[217] + + MLP FFT IsABC + Te + + MLP STAT IsABC + Te [218] + MLP FFT IsABC [219] + CNN WPT+FFT IsABC”
BackgroundInfluentialLu, S., Wang, X., He, Q., Liu, F., & Liu, Y. (2016) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2016.09.012 · Cited by 109 · cited 5×
“In [117], [122], [129] the information about the rotation direction is obtained from the phase current waveform, in [118] from a magnetic sensor mounted on the motor housing, in [123] from a mechanical vibration signal, while in [130] from an acoustic signal.”
BackgroundMethodInfluentialModern Diagnostics Techniques for Electrical Machines, Power Electronics, and Drives
Capolino, G., Daviu, J. A. A., & Riera‐Guasp, M. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2391186 · Cited by 109
Cost-Effective Three-Phase PMSM Drive Tolerant to Open-Phase Fault
Kontarcek, A., Bajec, P., Nemec, M., Ambrozic, V., & Nedeljkovic, D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2437357 · Cited by 106 · cited 2×
“Chapter IXB, in a part concerning CS fault detection presents, among others the possibilities of using model-based stator current estimators in CS-FDD systems [317]-[322].”
MethodAwadallah, M. A., Morcos, M. M., Gopalakrishnan, S., & Nehl, T. W. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847976 · Cited by 105 · cited 2×
“[56] Summation of phase voltages DFT fs EV, ON, RL, RS SC, summation of phase voltages has to be calculated”
BackgroundMitigation of Turn-to-Turn Faults in Fault Tolerant Permanent Magnet Synchronous Motors
Cintron-Rivera, J. G., Foster, S. N., & Strangas, E. G. (2015) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2360813 · Cited by 104
Hong, J., Lee, S. B., Kral, C., & Haumer, A. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2176145 · Cited by 103 · cited 4×
“The basic diagnostic signals in eccentricity diagnosis are: stator current [135], [143]-[146], [150], [151], [156]-[159], [161], [162], mechanical vibrations [149], [155], [156], noise [155], an airgap search coil voltage [149], [152], [156], [160], stator voltage [159], speed [159], load torque [159], d-axis stator i…”
BackgroundMethodInfluentialDelgado-Prieto, M., Espinosa, A. G., Ruiz, J.-R. R., Urresty, J.-C., & Ortega, J. A. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066538 · Cited by 101 · cited 9×
“Then, these CWD-prepared damage characteristics are extracted using the box counting method.”
MethodInfluentialComprehensive Evaluation of Inter-Turn Short Circuit Faults in PMSM Used for Electric Vehicles
Zhao, J., Guan, X., Li, C., Mou, Q., & Chen, Z. (2021) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2020.2987637 · Cited by 101
Haje Obeid, N., Battiston, A., Boileau, T., & Nahid-Mobarakeh, B. (2017) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2017.2743419 · Cited by 98 · cited 4×
“The quadrature component of the reference voltage vector is used as the diagnostic signal in [69] and [73].”
BackgroundMethodInfluentialBaudart, F., Dehez, B., Matagne, E., Telteu-Nedelcu, D., Alexandre, P., & Labrique, F. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2170393 · Cited by 98 · cited 1×
“Different control strategies were used including simple reconfiguration of the controller input and outputs [315], sliding-mode controller (SMC) [316]”
MethodMohammed, O. A., Liu, Z., Liu, S., & Abed, N. Y. (2007) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2006.892301 · Cited by 97 · cited 2×
“[74], [75] DWT fDC, 2fs, RMS values of selected details coefficients EV, ON, RL SC”
BackgroundMethodLu, S., He, Q., & Zhao, J. (2017) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2017.02.046 · Cited by 97 · cited 4×
“In [117], [122], [129] the information about the rotation direction is obtained from the phase current waveform, in [118] from a magnetic sensor mounted on the motor housing, in [123] from a mechanical vibration signal, while in [130] from an acoustic signal.”
BackgroundMethodInfluentialMoosavi, S. S., Djerdir, A., Amirat, Y. A., & Khaburi, D. A. (2015) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2015.04.062 · Cited by 96 · cited 6×
“PM are sensitive to too high working temperature [29], [30], [32].”
BackgroundMethodInfluentialDa, Y., Shi, X., & Krishnamurthy, M. (2011) · 2011 IEEE Vehicle Power and Propulsion Conference · doi:10.1109/vppc.2011.6043248 · Cited by 96 · cited 7×
“Damage to the insulation results from abrasion caused by mechanical stress or overheating of the winding as a result of excessive loads on the motor [14]-[20], [23], [26], [27].”
BackgroundMethodInfluentialNyanteh, Y. D., Edrington, C. S., Srivastava, S., & Cartes, D. A. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2253081 · Cited by 95 · cited 3×
“The MLP network is characterized by an extremely simple mathematical description, thanks to which it is used in the case of mechanical damages: bearing damage [121, 231], eccentricity [231], and in the case of the damage to the stator electrical circuits [215-218], [224], [225], [232], supply voltage unbalance [219],…”
MethodInfluentialDemagnetization Fault Diagnosis in Surface Mounted Permanent Magnet Synchronous Motors
Ebrahimi, B. M., & Faiz, J. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2217978 · Cited by 95 · cited 2×
“[114] Torque TDE radius of gyration in phase-space PDF, UDF, NINV, ON AOF, TEM, LS”
MethodDuan, P., Xie, K., Zhang, L., & Rong, X. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2095470 · Cited by 95 · cited 2×
“30 VOLUME XX, 2017 [268] Average values of current signals”
BackgroundChoi, C., & Lee, W. (2012) · IET Electric Power Applications · doi:10.1049/iet-epa.2011.0315 · Cited by 95
Wang, S., Yang, K., & Chen, K. (2019) · IEEE Access · doi:10.1109/access.2019.2925214 · Cited by 95
Gurusamy, V., Bostanci, E., Li, C., Qi, Y., & Akin, B. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3013128 · Cited by 93
Real-Time Detection of Interturn Faults in PM Drives Using Back-EMF Estimation and Residual Analysis
Leboeuf, N., Boileau, T., Nahid-Mobarakeh, B., Clerc, G., & Meibody-Tabar, F. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168929 · Cited by 92 · cited 2×
“In [80], an on-line time domain ITSC fault detection method is proposed, which is based on a residual analysis between the estimated stator currents obtained by a healthy model, accounting for BEMF estimation, inverter model and unbalanced inductance matrix and the real currents of the PMSM.”
BackgroundMethodKang, K., Song, J., Kang, C., Sung, S., & Jang, G. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2686376 · Cited by 91
Synchronous Demodulation of Control Voltages for Stator Interturn Fault Detection in PMSM
Boileau, T., Leboeuf, N., Nahid-Mobarakeh, B., & Meibody-Tabar, F. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2254132 · Cited by 90
Finite-Control-Set MPC for Open-Phase Fault-Tolerant Control of PM Synchronous Motor Drives
Kiselev, A., Catuogno, G. R., Kuznietsov, A., & Leidhold, R. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2931285 · Cited by 88
A Fast and Robust Open-Switch Fault Diagnosis Method for Variable-Speed PMSM System
Zhou, X., Sun, J., Cui, P., Lu, Y., Lu, M. L., & Yu, Y. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3013628 · Cited by 88
Comprehensive review on inter‐turn fault indexes in permanent magnet motors
Faiz, J., Nejadi‐Koti, H., & Valipour, Z. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0196 · Cited by 86 · cited 3×
“Analysing the survey-type articles, it should be mentioned that the excellent reviews of single faults in PMSM are presented in [26]-[31], concerning ITSCs, demagnetization and eccentricity faults, including description of the physical phenomena connected with particular defects and fault indices used for their detect…”
BackgroundMethodLuo, Y., & Liu, C. (2019) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2018.2883665 · Cited by 84 · cited 1×
“On the other hand, the modular motor is designed to have a number of three-phase modules, each controlled by an independent three-phase inverter [320].”
BackgroundWu, F., & Zhao, J. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2587339 · Cited by 82 · cited 3×
“[270] Topology symmetry analysis based on signal statistical parameters”
BackgroundMethodAnalysis and Experimental Verification of a Fault-Tolerant HEV Powertrain
Song, Y., & Wang, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2245513 · Cited by 81
Overview of fault diagnosis theory and method for permanent magnet machine
(2015) · Chinese Journal of Electrical Engineering · doi:10.23919/cjee.2015.7933135 · Cited by 81
Detection of Partial Demagnetization Fault in PMSMs Operating Under Nonstationary Conditions
Wang, C., Delgado-Prieto, M., Romeral, L., Chen, Z., Blaabjerg, F., & Liu, X. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2015.2511003 · Cited by 79 · cited 2×
“[113] Stator current VKF-OT amplitude of ENVs of fault characteristic orders PDF, NINV, ON”
BackgroundMethodZhang, G., Zhou, H., Wang, G., Li, C., & Xu, D. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2941255 · Cited by 79
Overview of permanent-magnet fault-tolerant machines: Topology and design
Zhao, W., Xu, L. H., & Liu, G. (2018) · CES Transactions on Electrical Machines and Systems · doi:10.23919/tems.2018.8326451 · Cited by 78
Salmasi, F. R., Najafabadi, T. A., & Maralani, P. J. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2038268 · Cited by 77 · cited 2×
“fault the FTC strategy is usually based on the adaptive voltage observer [277], [278].”
BackgroundYang, Z. Y., Shi, X., & Krishnamurthy, M. (2014) · IEEE Transportation Electrification Conference and Expo · doi:10.1109/itec.2014.6861774 · Cited by 76 · cited 3×
“[99] Vibration FFT PDF, NINV, ON, NAOF SC, VM, MS”
BackgroundMethodUllah, Z., & Hur, J. (2018) · Energies · doi:10.3390/en11123309 · Cited by 76
Magnets faults characterization for Permanent Magnet Synchronous Motors
Casadei, D., Filippetti, F., Rossi, C., & Stefani, A. (2009) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2009.5292770 · Cited by 75 · cited 3×
“14 VOLUME XX, 2017 [94]-[96] BEMF FFT PDF, NINV, AOF SC, OFF, MS”
MethodIshikawa, T., Seki, Y., & Kurita, N. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2243135 · Cited by 75 · cited 2×
“[102]-[104] CWT/DWT UDF, RS, RL, NINV, EV MS”
BackgroundWelchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2003) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2003.1211315 · Cited by 75
Zhu, M., Hu, W., & Kar, N. C. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2634518 · Cited by 74
Zhang, J., Xu, Z., Wang, J., Zhao, J., Din, Z., & Cheng, M. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3009563 · Cited by 74
Urresty, J.-C., Riba, J.-R., & Romeral, L. (2012) · Electric Power Systems Research · doi:10.1016/j.epsr.2012.02.012 · Cited by 73 · cited 3×
“In recent years, the papers in which authors proposed the use of ZSVC spectral analysis using FFT for the detection of PMSM stator winding faults were also published [59]-[64].”
BackgroundUrresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2247046 · Cited by 73 · cited 5×
“The proper combination of the analyses of stator current and zero sequence current, or zero sequence and q-axis current enables fault determination for any range of speeds [87], [89].”
BackgroundInfluentialAirgap Search Coil Based Identification of PM Synchronous Motor Defects
Rafaq, M. S., Lee, H., Park, Y., Lee, S. B., Orviz, M., Fernández, D., Reigosa, D., & Briz, F. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3095810 · Cited by 73
Diagnosis Methods for IGBT Open Switch Fault Applied to 3-Phase AC/DC PWM Converter
Im, W.-S., Kim, J.-S., Kim, J.-M., Lee, D., & Lee, K. (2012) · Journal of Power Electronics · doi:10.6113/jpe.2012.12.1.120 · Cited by 72 · cited 2×
“Some of them utilize the solutions based on the current hodograph analysis [266].”
BackgroundMethodConvolutional Neural Network-Based Inter-Turn Fault Diagnosis in LSPMSMs
Maraaba, L. S., Milhem, A. S., Nemer, I. A., Al-Duwaish, H., & Abido, M. A. (2020) · IEEE Access · doi:10.1109/access.2020.2991137 · Cited by 72
Rafaq, M. S., Lee, H., Park, Y., Lee, S. B., Fernández, D., Reigosa, D., & Briz, F. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3088332 · Cited by 72
A review of current issues of marine current turbine blade fault detection
Xie, T., Wang, T., He, Q., Diallo, D., & Claramunt, C. (2020) · Ocean Engineering · doi:10.1016/j.oceaneng.2020.108194 · Cited by 72
Wang, C.-S., Kao, I.-H., & Perng, J. (2021) · Sensors · doi:10.3390/s21113608 · Cited by 70
Robust Stator Winding Fault Detection in PMSMs With Respect to Current Controller Bandwidth
Huang, S., Aggarwal, A., Strangas, E. G., Li, K., Niu, F., & Huang, X. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3030036 · Cited by 70
Bhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
Speed/position sensor fault tolerant control in adjustable speed drives – A review
Bourogaoui, M., Sethom, H. B. A., & Belkhodja, I. S. (2016) · ISA Transactions · doi:10.1016/j.isatra.2016.05.003 · Cited by 67 · cited 2×
“Since hardware redundancy is expensive or sometimes impossible to implement, software redundancy is a good solution, which involves the use of various types of state variable estimators and replacing the signals from the damaged sensors with estimated ones [33], [274].”
BackgroundMethodStudy on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines
Rosero, J. A., Cusido, J., Garcia, A., Ortega, J. A., & Romeral, L. (2006) · IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics · doi:10.1109/iecon.2006.347598 · Cited by 67 · cited 1×
“The usage of FFT analysis requires a compromise between the precision of the assessment of damage symptoms and the minimum computational effort [86], [88].”
MethodNovel Diagnostic Techniques for Rotating Electrical Machines—A Review
Frosini, L. (2020) · Energies · doi:10.3390/en13195066 · Cited by 67 · cited 10×
“The PM demagnetization can be uniform over all poles or partial over certain region or poles [15], [18], [29], [32].”
BackgroundMethodInfluentialReview of fault modeling methods for permanent magnet synchronous motors and their comparison
Usman, A., Joshi, B. M., & Rajpurohit, B. S. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062347 · Cited by 66
Fault Tolerant Flight Control - A Survey
Verhaegen, M., Kanev, S., Hallouzi, R., Jones, C., Maciejowski, J., & Smail, H. (2010) · Lecture Notes in Control and Information Sciences · doi:10.1007/978-3-642-11690-2_2 · Cited by 65 · cited 1×
“However, the use of PFTC is limited in AC drives for the following reasons [33], [306]: − when designing a PFTC system, only selected system failures can be taken into account, usually those that do”
BackgroundA Voltage-Based Approach for Fault Detection and Separation in Permanent Magnet Synchronous Machines
Haddad, R. Z., Lopez, C. A., Foster, S. N., & Strangas, E. G. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2726072 · Cited by 65
Sensor Fault-Resilient Control of Interior Permanent-Magnet Synchronous Motor Drives
Beng, G. F. H., Zhang, X., & Vilathgamuwa, D. M. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2311126 · Cited by 65 · cited 3×
“More interesting solution, which consists in a special kind of adaptive observer of the DC-link voltage is presented in [278].”
BackgroundMethodWang, X., Lu, S., Huang, W., Wang, Q., Zhang, S., & Xia, M. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3051668 · Cited by 65 · cited 6×
“[117], [118], [123]-[126] OA NINV, SM2 [118], SM3 [123], [124], [126], SM1 [125], MDB2 [125], TC [117], [118], [123]-[126], IIoT [118], validated on BLDCM [125] OD [123], [124], [126], VM”
BackgroundMethodInfluentialGarcía, J. R., Romeral, L., Ortega, J. A., & Urresty, J.-C. (2008) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2008.4677217 · Cited by 64
Fault-Tolerant Control of PMSM With Inter-Turn Short-Circuit Fault
Zhang, J., Zhan, W., & Ehsani, M. (2019) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2019.2936225 · Cited by 64
On the short-circuiting Fault Detection in a PMSM by means of Stator Current Transformations
Rosero, J. A., Romeral, L., Cusido, J., Garcia, A., & Ortega, J. A. (2007) · 2007 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2007.4342300 · Cited by 63 · cited 2×
“Additionally, as proven in [41], the stator winding ITSC may cause an increase in the slot harmonics, which are calculated with the following equation:”
BackgroundA review of Permanent Magnet Synchronous Motor fault diagnosis
ZhifuWang, Yang, J., Ye, H., & Zhou, W. (2014) · 2014 IEEE Conference and Expo Transportation Electrification Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itec-ap.2014.6940870 · Cited by 62 · cited 4×
“Few conference papers were published as well [24], [25], presenting very preliminary review of condition monitoring and fault diagnosis techniques for PM motors.”
BackgroundMethodInfluentialTrabelsi, M., Semail, E., & Nguyen, N. K. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2719634 · Cited by 61 · cited 1×
“Therefore, due to the hazardous effects of this type of the damage, many methods of its detection have been developed in last decades [253].”
BackgroundAn On-Line Stator Turn Fault Detection Method for Interior PM Synchronous Motor Drives
Lee, Y., & Habetler, T. G. (2007) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apex.2007.357610 · Cited by 60 · cited 1×
“[51]-[53] Reference voltage in dq frame FFT fDC, 2fs EV, ON, RL, RS SC, access to reference voltage in dq frame signal necessary”
BackgroundSayed, W. E., Abdel-Geliel, M., & Lotfy, A. (2020) · Energies · doi:10.3390/en13112972 · Cited by 60
Wang, W., Feng, Y., Shi, Y., Cheng, M., Hua, W., & Wang, Z. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2899168 · Cited by 59
Mohammed, O. A., Liu, S., & Liu, Z. (2006) · Digest of the Fifth Biennial IEEE Conference on Electromagnetic Field Computation · doi:10.1109/cefc-06.2006.1632949 · Cited by 59
Khojet El Khil, S., Jlassi, I., Estima, J. O., Mrabet‐Bellaaj, N., & Marques Cardoso, A. J. (2016) · Electronics Letters · doi:10.1049/el.2016.2198 · Cited by 58
García, J. R., Romeral, L., Rosero, E., & Urresty, J.-C. (2009) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2009.4802777 · Cited by 57 · cited 23×
“The CWT uses an adaptive time window, ensuring good resolution in both time and frequency domains.”
BackgroundMethodInfluentialMagnetic and corrosion characteristics of Nd-Fe-B magnet with various surface coatings
Cheng, C. W., Man, H. C., & Cheng, F. T. (1997) · IEEE Transactions on Magnetics · doi:10.1109/20.619612 · Cited by 56 · cited 1×
“They are made in powder technology, which is related to the problem of oxidation of the elements with increasing temperature [36].”
BackgroundConfiguration Impacts on Eccentricity Fault Detection in Permanent Magnet Synchronous Motors
Ebrahimi, B. M., & Faiz, J. (2012) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2011.2172977 · Cited by 54 · cited 9×
“In [65] the application of the PSD, MUSIC, and BS of the stator phase current signal to PMSM stator short-circuit detection is evaluated and compared.”
BackgroundMethodInfluentialLiang, Y., Wang, R., & Hu, B. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3003058 · Cited by 54 · cited 1×
“abnormal load operation, overheating, decreased efficiency and the motor output irresistible torque gap, resulting in large torque ripple or even braking torque [22], [251].”
BackgroundPietrzak, P., & Wolkiewicz, M. (2021) · Electronics · doi:10.3390/electronics10151786 · Cited by 54
Self-citationStrangas, E. G., Aviyente, S., Neely, J., & Zaidi, S. S. H. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2227913 · Cited by 53 · cited 3×
“This allows the detection of occurring failures at their initial stage and the prognosis of the drive system RUL [4]-[6].”
BackgroundObeid, N. H., Boileau, T., & Nahid-Mobarakeh, B. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2581760 · Cited by 52
Riba, J., Espinosa, A. G., Romeral, L., & Cusidó, J. (2010) · Electric Power Systems Research · doi:10.1016/j.epsr.2010.04.010 · Cited by 51 · cited 4×
“In conference papers [109], [110] and following articles [111], [112] the HHT was applied to stator current signal obtained from FEM simulation model of the PMSM with DF under different speed and load torque values.”
MethodInfluentialD-Q Current Signature-Based Faulted Phase Localization for SM-PMAC Machine Drives
Kuruppu, S. S., & Kulatunga, N. A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2334652 · Cited by 51 · cited 3×
“A simple and fast diagnostic method for single open phase fault detection based on control structure signals has been first proposed in [184] and further developed in [185].”
MethodYang, M., Chai, N., Liu, Z., Ren, B., & Xu, D. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2922919 · Cited by 49
State of the Art on Stray Flux Analysis in Faulted Electrical Machines
Capolino, G., Romary, R., Henao, H., & Pusca, R. (2019) · IEEE Workshop on Electrical Machines Design, Control and Diagnosis · doi:10.1109/wemdcd.2019.8887805 · Cited by 49
Detecting faults in rotors of PM drives
Roux, W., Harley, R., & Habetler, T. (2008) · IEEE Industry Applications Magazine · doi:10.1109/mia.2007.915789 · Cited by 48 · cited 4×
“Different, on-line operation based idea to detect the eccentricity is shown in [178].”
BackgroundInfluentialStator Faults Modeling and Diagnostics of Line-Start Permanent Magnet Synchronous Motors
Fonseca, D. S. B., Santos, C. M. C., & Cardoso, A. J. M. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2979674 · Cited by 48
Ewert, P., Orlowska-Kowalska, T., & Jankowska, K. (2021) · Energies · doi:10.3390/en14030712 · Cited by 48
Self-citationFault detection in voltage-fed PWM motor drive systems
Ribeiro, R. L. A., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2002) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2000.878849 · Cited by 48
Review of fault diagnosis of PMSM drive system in electric vehicles
Zheng, J., Wang, Z., Wang, D., Li, Y., & Li, M. (2017) · Chinese Control Conference (CCC) · doi:10.23919/chicc.2017.8028529 · Cited by 47 · cited 9×
“In [18], as well as in [16], the detection of mechanical damages and methods based on AI are not taken into account at all, while different categories of FIs for ITSC and irreversible demagnetization fault are discussed.”
BackgroundMethodInfluentialReal-Time Switches Fault Diagnosis for Voltage Source Inverter Driven Induction Motor Drive
Hichem, M., Bahi, T., Bedoud, K., et al. (2019) · International Journal of Electrical and Electronic Engineering & Telecommunications · doi:10.18178/ijeetc.8.2.103-107 · Cited by 47
Haddad, R. Z., & Strangas, E. G. (2013) · 2013 9th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2013.6645703 · Cited by 46 · cited 2×
“According to [40], the frequency components, the amplitudes of which increase as a result of the failure of the stator winding, are calculated as follows:”
BackgroundJiang, Y., Zhang, Z., Jiang, W., Geng, W., & Huang, J. (2018) · IET Electric Power Applications · doi:10.1049/iet-epa.2017.0754 · Cited by 45
Field programmable gate array-based fault-tolerant hysteresis current control for AC machine drives
Berriri, H., Naouar, W., Bahri, I., Slama-Belkhodja, I., & Monmasson, E. (2012) · IET Electric Power Applications · doi:10.1049/iet-epa.2011.0053 · Cited by 44
Rosero, J., Romeral, J. L., Cusido, J., Ortega, J. A., & Garcia, A. (2008) · 2008 Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2008.4522708 · Cited by 44 · cited 7×
“[116], [131], [132], [135]-[137] Stator current FFT fb =fs±kfu fu – characteristic failure frequency of the bearing k=1,2,3.”
BackgroundMethodInfluentialRajagopalan, S., Restrepo, J. A., Aller, J. M., Habetler, T. G., & Harley, R. G. (2005) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2005.4662511 · Cited by 44 · cited 2×
“: STFT [101], WT [102]-[106], WVD [101], [107], CWD [108], and HHT [109]-[112].”
MethodVold–Kalman Filtering Order Tracking Based Rotor Demagnetization Detection in PMSM
Zhu, M., Yang, B., Hu, W., Feng, G., & Kar, N. C. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2932692 · Cited by 44
Novel Bearing Fault Diagnosis Using Gaussian Mixture Model-Based Fault Band Selection
Maliuk, A. S., Prosvirin, A. E., Ahmad, Z., Kim, C. H., & Kim, J.-M. (2021) · Sensors · doi:10.3390/s21196579 · Cited by 44 · cited 6×
“In [127], the Gaussian mixture model-based bearing fault band selection method is used to remove information indicative of bearing damage from the high-frequency band, but not informing about the type of damaged bearing component.”
BackgroundMethodInfluentialElectrical monitoring for fault detection in an EMA
Romeral, L., Garcia, J. A. R., Espinosa, A. G., et al. (2010) · IEEE Aerospace and Electronic Systems Magazine · doi:10.1109/maes.2010.5463950 · Cited by 42 · cited 4×
“The basic diagnostic signals in eccentricity diagnosis are: stator current [135], [143]-[146], [150], [151], [156]-[159], [161], [162], mechanical vibrations [149], [155], [156], noise [155], an airgap search coil voltage [149], [152], [156], [160], stator voltage [159], speed [159], load torque [159], d-axis stator i…”
BackgroundMethodInfluentialQuiroga, J., Liu, L., & Cartes, D. A. (2008) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2008.4587163 · Cited by 42 · cited 3×
“[48]-[50] Stator current negative sequence component FFT fs, 3fs EV, ON, RL, RS SC, current negative sequence component has to be calculated”
BackgroundMethodDiagnosis of stator winding short-circuit faults in an interior permanent magnet synchronous machine
He, J., Somogyi, C. A., Strandt, A. P., & Demerdash, N. A. O. (2014) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6953825 · Cited by 42
A novel method based on self-sensing motor drive system for misalignment detection
Yao, Y., Li, Y., & Yin, Q. (2019) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2018.06.030 · Cited by 42 · cited 3×
“In [175], the frequency response of the tested PMSM drive with parallel misalignment was analyzed, while in [176] it was shown in simulations and in experimental tests that the virtual phase torque (VPT) diagram method based on self-”
BackgroundMethodEccentricity fault diagnosis indices for permanent magnet machines: state‐of‐the‐art
Faiz, J., & Nejadi-Koti, H. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2018.5751 · Cited by 41
Maraaba, L. S., Al‐Hamouz, Z., Milhem, A. S., & Abido, M. A. (2019) · IEEE Access · doi:10.1109/access.2019.2923746 · Cited by 41
Research works printed but not linked: 7
- Krichen, Fault detection and diagnosis methods in permanent magnet synchronous machines: A review, 229
- Varal, 2017, Bearing fault analysis of permanent magnet synchronous motor (PMSM) using current signature analysis, Int. Res. J. Eng. Technol., 4, 410
- Abbas, 2014, Bearings fault diagnosis in direct torque control permanent magnet synchronous motor based on discrete wavelet transform and artificial neural network, Int. J. Adv. Eng. Technol., 7, 341
- 10.1049/iet-epa.2012.0316 · DOI · Paper page
- 10.1109/TIE.2017.2688973 · DOI · Paper page
- 10.1109/TEC.2017.2726142 · DOI · Paper page
- 10.1109/TEC.2019.2936225 · DOI · Paper page
Cited by
Pietrzak, P., & Wolkiewicz, M. (2023) · Sensors · doi:10.3390/s23041757 · Cited by 76
“Damage to PMs can be divided into mechanical damage of the PM (cracks, chipping) and those associated with the phenomenon of demagnetization [1,8].”
BackgroundSelf-citationCheng, M., Zhou, J., Qian, W., Wang, B., Zhao, C., & Han, P. (2024) · Chinese Journal of Electrical Engineering · doi:10.23919/cjee.2023.000048 · Cited by 80
El-Dalahmeh, M., Al‐Greer, M., Bashir, I., El‐Dalahmeh, M., Demirel, A., & Keysan, O. (2023) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2023.108894 · Cited by 73
Mueller, P. N., Woelfl, L., & Can, S. (2023) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2023.106834 · Cited by 58
Fault Diagnosis of Electric Motors by a Channel-Wise Regulated CNN and Differential of STFT
Mohammad‐Alikhani, A., Jamshidpour, E., Dhale, S., Akrami, M., Pardhan, S., & Nahid‐Mobarakeh, B. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3532556 · Cited by 53
Metadata
- Authors
- Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T.
- Affiliations
- Department of Electrical Machines, Drives and Measurements, Wrocław University of Science and Technology, Wrocław, Poland
- Wrocław University of Science and Technology (PL)
- ORCID
- Venue
- IEEE Access
- Published
- 2022
- Volume
- 10
- Pages
- 59979-60024
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W4285271556
- Semantic Scholar
- dc069ddc2dd7fed25b6db8df368599dab4ad9d8b
- Cited by
- 328
- References
- 335
- Citations by year
- 2026: 72 · 2025: 112 · 2024: 81 · 2023: 52 · 2022: 11
- FWCI
- 21.95
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- IEEE Access (publishedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- National Science Centre Poland (2017/27/B/ST7/00816)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Keywords
- permanent magnet synchronous motor, fault diagnosis, fault-tolerant control, motor drives, stator winding faults, bearing defects, rotor faults, power converter faults, sensor faults, artificial neural networks, safety-critical systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-06, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-06 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.