A Novel Fault Diagnosis Technique for IPMSM Using Voltage Angle
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Different kinds of faults in the motor can occur, which causes various and independent variations in the magnetic flux distribution of machine and consequently causes different changes in the behavior of the motor and its performance. These changes reflect in the machine flux linkage, which can be determined by the machine voltage. A novel fault detection and identification technique for inter-turn-short fault and irreversible demagnetization fault in interior permanent magnet synchronous motor are presented in this paper. The deviation caused by the inter-turn short fault and irreversible demagnetization fault in the angle between d-axis voltage and q-axis voltage, which is termed as voltage or load angle is analyzed. It is observed that in case of demagnetization fault the voltage angle increases, whereas in case of inter-turns short fault it decreases. In this study, we used this unique phenomenon for the detection and identification of these faults. The proposed method is verified by simulation and experiments.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, the instantaneous value of the angle between the reference voltage components has been directly used as an efficient FI in [181].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [181]
In the citing paper
“This angle has been also used in order to distinguish between two different faults (ITSC and DF, as it decreases or increases with the fault, respectively).”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [181]
Citations
Cites
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544 · cited 1×
“It is due to the variation in harmonic components in the stator current [20].”
BackgroundFault Detection in Induction Machines Using Power Spectral Density in Wavelet Decomposition
Cusid�Cusido, J., Romeral, L., Ortega, J. A., Rosero, J. A., & Garc�aGarcia Espinosa, A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911960 · Cited by 512 · cited 5×
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
BackgroundInfluentialCruz, S. M. A., & Cardoso, A. J. M. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.952496 · Cited by 464
Henao, H., Demian, C., & Capolino, G.-A. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.816531 · Cited by 361 · cited 1×
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
BackgroundSchiferl, R. F., & Lipo, T. A. (1990) · IEEE Transactions on Industry Applications · doi:10.1109/28.52682 · Cited by 318
Inter-turn stator winding fault diagnosis in three-phase induction motors, by Park's vector approach
Marques Cardoso, A. J., Cruz, S. M. A., & Fonseca, D. S. B. (1999) · IEEE Transactions on Energy Conversion · doi:10.1109/60.790920 · Cited by 315
Schiferl, R., & Lipo, T. A. (2003) · Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1988.25037 · Cited by 311 · cited 1×
“INTRODUCTION Interior Permanent magnet synchronous motors (IPMSMs), due to their high torque density, compact rotor design, and excellent servo performances, widely used in various applications, such as electric vehicles (EV), aircrafts, unmanned aerial vehicles (UAV), and electric scooters [1].”
BackgroundDa, Y., Shi, X., & Krishnamurthy, M. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227808 · Cited by 303 · cited 1×
“An approach based on search coil voltage is proposed for the monitoring and identification of the faults [26].”
MethodModeling of Surface-Mounted Permanent Magnet Synchronous Motors With Stator Winding Interturn Faults
Romeral, L., Urresty, J. C., Riba Ruiz, J.-R., & Garcia Espinosa, A. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2062480 · Cited by 282 · cited 1×
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
BackgroundDetecting Rotor Faults in Low Power Permanent Magnet Synchronous Machines
le Roux, W., Harley, R. G., & Habetler, T. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886620 · Cited by 274 · cited 1×
“[24] and [25] proposed an indicator of magnetic defect using the average estimation of magnetic flux and torque constant, and CSA is used for diagnosing of EF, yet the temperature might affect such estimation.”
Cruz, S. M. A., & Marques Cardoso, A. J. (2002) · Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129) · doi:10.1109/ias.2000.881141 · Cited by 258 · cited 1×
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
BackgroundRuiz, J.-R. R., Rosero, J. A., Espinosa, A. G., & Romeral, L. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2015942 · Cited by 231 · cited 2×
“Frequency-time distribution of stator current analysis, such as Wavelet transform is used to extract frequency-time distribution from the current signal in the non-stationary condition [29].”
BackgroundMethodHong, J., Park, S., Hyun, D., Kang, T.-J., Lee, S. B., Kral, C., & Haumer, A. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2191253 · Cited by 219 · cited 1×
“Furthermore, in [28], the variation in equivalent inductance is monitored to distinguish EF and IDF.”
BackgroundSelf-citationA Model-Based Strategy for Interturn Short-Circuit Fault Diagnosis in PMSM
Mazzoletti, M. A., Bossio, G. R., De Angelo, C. H., & Espinoza-Trejo, D. R. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2688973 · Cited by 214
Kim, K.-H. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2060463 · Cited by 184 · cited 1×
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
BackgroundUrresty, J.-C., Riba, J.-R., Delgado, M., & Romeral, L. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2011.2176127 · Cited by 181 · cited 1×
“The partial demagnetization and eccentricity fault (EF) has some identical frequency characteristic in the current signature analysis (CSA), such as sideband frequency pattern [23].”
BackgroundSarikhani, A., & Mohammed, O. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222857 · Cited by 177 · cited 1×
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
BackgroundOnline stator fault diagnosis in inductionmotors
Arkan, M., Perović, D. K., & Unsworth, P. (2001) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20010588 · Cited by 164 · cited 1×
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
BackgroundRajagopalan, S., Roux, W. L., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904183 · Cited by 164 · cited 1×
“[24] and [25] proposed an indicator of magnetic defect using the average estimation of magnetic flux and torque constant, and CSA is used for diagnosing of EF, yet the temperature might affect such estimation.”
Cheng, S., Zhang, P., & Habetler, T. G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2064276 · Cited by 149 · cited 1×
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
BackgroundDiscernment of Broken Magnet and Static Eccentricity Faults in Permanent Magnet Synchronous Motors
Goktas, T., Zafarani, M., & Akin, B. (2016) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2015.2512602 · Cited by 140 · cited 1×
“For magnetic defects, a formula for back electromotive force (BEMF) has been proposed in [27], and certain frequencies in stator current spectrum are used as signature to separate IDF and EF.”
MethodAwadallah, M. A., Morcos, M. M., Gopalakrishnan, S., & Nehl, T. W. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847976 · Cited by 105 · cited 1×
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
BackgroundNeti, P., & Nandi, S. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2018905 · Cited by 103 · cited 1×
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
BackgroundStone, G., & Kapler, J. (1998) · IEEE Industry Applications Magazine · doi:10.1109/2943.715501 · Cited by 99 · cited 2×
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
BackgroundReal-Time Detection of Interturn Faults in PM Drives Using Back-EMF Estimation and Residual Analysis
Leboeuf, N., Boileau, T., Nahid-Mobarakeh, B., Clerc, G., & Meibody-Tabar, F. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168929 · Cited by 92 · cited 1×
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
BackgroundSynchronous Demodulation of Control Voltages for Stator Interturn Fault Detection in PMSM
Boileau, T., Leboeuf, N., Nahid-Mobarakeh, B., & Meibody-Tabar, F. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2254132 · Cited by 90 · cited 1×
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
BackgroundWinding condition monitoring scheme for a permanent magnet machine using high-frequency injection
Arellano-Padilla, J., Sumner, M., & Gerada, C. (2011) · IET Electric Power Applications · doi:10.1049/iet-epa.2009.0264 · Cited by 76 · cited 1×
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
BackgroundUrresty, J.-C., Riba, J.-R., & Romeral, L. (2012) · Electric Power Systems Research · doi:10.1016/j.epsr.2012.02.012 · Cited by 73 · cited 3×
“To overcome the shortcomings and limitations of MCSA method a zero sequence component based technique is proposed and has been successfully applied to diagnosis ITSF in the machine [21].”
BackgroundMethodGu, B.-G. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2496142 · Cited by 48 · cited 1×
“Hence, the IPMSM behavior under healthy and fault condition is the main reliability index for the entire system [2].”
BackgroundUrresty, J.-C., Riba, J., Saavedra, H., & Romeral, L. (2011) · RECERCAT (Consorci de Serveis Universitaris de Catalunya) · Cited by 39
Urresty, Riba, Saavedra, & Romeral (2011) · RECERCAT (Consorci de Serveis Universitaris de Catalunya) · Cited by 24
Research works printed but not linked: 2
- 10.1109/tie.2010.2062480 · DOI · Paper page
- 10.1109/tpel.2012.2227808 · DOI · Paper page
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“However, the instantaneous value of the angle between the reference voltage components has been directly used as an efficient FI in [181].”
MethodFault Detection and Diagnosis of the Electric Motor Drive and Battery System of Electric Vehicles
Khaneghah, M. Z., Alzayed, M., & Chaoui, H. (2023) · Machines · doi:10.3390/machines11070713 · Cited by 138
“This section reviews some of the recent data-driven FDD methods for electrical, mechanical and sensor faults”
BackgroundUllah, Z., Lodhi, B. A., & Hur, J. (2020) · Energies · doi:10.3390/en13153834 · Cited by 82
Self-citationUllah, Z., & Hur, J. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2961878 · Cited by 35
“2961878 make it an ideal choice for such applications [2].”
BackgroundSelf-citationA Torque Angle-Based Fault Detection and Identification Technique for IPMSM
Ullah, Z., Lee, S.-T., & Hur, J. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2947401 · Cited by 34
“This article proposed a simple method for the online detection and identification of ITSF and PIDF using the torque angle (δ) variation caused by mentioned faults [26].”
MethodSelf-citation
Metadata
- Authors
- Ullah, Z., Lee, S.-T., & Hur, J.
- Affiliations
- Incheon National University (KR)
- Venue
- 2018 IEEE Energy Conversion Congress and Exposition (ECCE)
- Publisher
- IEEE
- Published
- 2018-09
- Pages
- 3236-3243
- OpenAlex
- W2903822690
- Cited by
- 13
- References
- 31
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 3 · 2023: 1 · 2022: 2 · 2021: 1 · 2020: 2 · 2019: 2
- FWCI
- 1.99
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE Energy Conversion Congress and Exposition (ECCE) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- interior permanent magnet synchronous motor, fault diagnosis, irreversible demagnetization, flux linkage, fault detection and identification
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.