A Novel Continuous Blood Pressure Estimation Approach Based on Data Mining Techniques
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Continuous blood pressure (BP) estimation using pulse transit time (PTT) is a promising method for unobtrusive BP measurement. However, the accuracy of this approach must be improved for it to be viable for a wide range of applications. This study proposes a novel continuous BP estimation approach that combines data mining techniques with a traditional mechanism-driven model. First, 14 features derived from simultaneous electrocardiogram and photoplethysmogram signals were extracted for beat-to-beat BP estimation. A genetic algorithm-based feature selection method was then used to select BP indicators for each subject. Multivariate linear regression and support vector regression were employed to develop the BP model. The accuracy and robustness of the proposed approach were validated for static, dynamic, and follow-up performance. Experimental results based on 73 subjects showed that the proposed approach exhibited excellent accuracy in static BP estimation, with a correlation coefficient and mean error of 0.852 and -0.001 ± 3.102 mmHg for systolic BP, and 0.790 and -0.004 ± 2.199 mmHg for diastolic BP. Similar performance was observed for dynamic BP estimation. The robustness results indicated that the estimation accuracy was lower by a certain degree one day after model construction but was relatively stable from one day to six months after construction. The proposed approach is superior to the state-of-the-art PTT-based model for an approximately 2-mmHg reduction in the standard derivation at different time intervals, thus providing potentially novel insights for cuffless BP estimation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Genetic algorithms in search, optimization, and machine learning
(1989) · Choice Reviews Online · doi:10.5860/choice.27-0936 · Cited by 49,010
Chobanian, A. V. (2003) · JAMA · doi:10.1001/jama.289.19.2560 · Cited by 25,386
An introduction to variable and feature selection
GuyonIsabelle, & ElisseeffAndré (2003) · Journal of Machine Learning Research · doi:10.5555/944919.944968 · Cited by 7,715
Support Vector Regression Machines
Drucker, H., Burges, C. J. C., Kaufman, L., Smola, A. J., & Vapnik, V. N. (1996) · Cited by 4,658
Feature subset selection using a genetic algorithm
Yang, J., & Honavar, V. (1998) · IEEE Intelligent Systems · doi:10.1109/5254.671091 · Cited by 1,362
Westerhof, N., Lankhaar, J.-W., & Westerhof, B. E. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0359-2 · Cited by 1,181
Computation of aortic flow from pressure in humans using a nonlinear, three-element model
Wesseling, K. H., Jansen, J. R., Settels, J. J., & Schreuder, J. J. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.5.2566 · Cited by 1,137
Data mining techniques and applications – A decade review from 2000 to 2011
Liao, S.-H., Chu, P.-H., & Hsiao, P.-Y. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2012.02.063 · Cited by 665
Determination of age-related increases in large artery stiffness by digital pulse contour analysis
MILLASSEAU, S. C., KELLY, R. P., RITTER, J. M., & CHOWIENCZYK, P. J. (2002) · Clinical Science · doi:10.1042/cs1030371 · Cited by 613
Takazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., & Ibukiyama, C. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.365 · Cited by 589
Gesche, H., Grosskurth, D., Küchler, G., & Patzak, A. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1983-3 · Cited by 470
Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00657.2005 · Cited by 418
Cuff-less and Noninvasive Measurements of Arterial Blood Pressure by Pulse Transit Time
Poon, C. C. Y., & Zhang, Y. T. (2005) · 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference · doi:10.1109/iembs.2005.1615827 · Cited by 375
Self-citationPhotoplethysmographic assessment of pulse wave reflection
Chowienczyk, P. J., Kelly, R. P., MacCallum, H., Millasseau, S. C., Andersson, T. L. G., Gosling, R. G., Ritter, J. M., & Änggård, E. E. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00441-6 · Cited by 363
Ding, X.-R., Zhang, Y.-T., Liu, J., Dai, W.-X., & Tsang, H. K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2480679 · Cited by 330
Self-citationNoninvasive Assessment of the Digital Volume Pulse: Comparison With the Peripheral Pressure Pulse
Millasseau, S. C., Guigui, F. G., Kelly, R. P., Prasad, K., Cockcroft, J. R., Ritter, J. M., & Chowienczyk, P. J. (2000) · Hypertension · doi:10.1161/01.hyp.36.6.952 · Cited by 294
Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin®
Martina, J. R., Westerhof, B. E., van Goudoever, J., de Beaumont, E. M. F. H., Truijen, J., Kim, Y.-S., Immink, R. V., Jöbsis, D. A., Hollmann, M. W., Lahpor, J. R., et al. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31824f94ed · Cited by 292
Silke, B., & McAuley, D. (1998) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000600 · Cited by 289
Teng, X. F., & Zhang, Y. T. (2004) · Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439) · doi:10.1109/iembs.2003.1280811 · Cited by 237
Self-citationZakopoulos, N. A., Tsivgoulis, G., Barlas, G., Papamichael, C., Spengos, K., Manios, E., Ikonomidis, I., Kotsis, V., Spiliopoulou, I., Vemmos, K., et al. (2005) · Hypertension · doi:10.1161/01.hyp.0000158306.87582.43 · Cited by 204
Palatini, P., Reboldi, G., Beilin, L. J., Casiglia, E., Eguchi, K., Imai, Y., Kario, K., Ohkubo, T., Pierdomenico, S. D., Schwartz, J. E., et al. (2014) · Hypertension · doi:10.1161/hypertensionaha.114.03694 · Cited by 193
Measurements of Young's modulus of elasticity of the canine aorta with ultrasound
Hughes, D. (1979) · Ultrasonic Imaging · doi:10.1016/0161-7346(79)90028-2 · Cited by 189
Use of Data Mining Techniques to Determine and Predict Length of Stay of Cardiac Patients
Hachesu, P. R., Ahmadi, M., Alizadeh, S., & Sadoughi, F. (2013) · Healthcare Informatics Research · doi:10.4258/hir.2013.19.2.121 · Cited by 184
Ding, X.-R., Zhao, N., Yang, G.-Z., Pettigrew, R. I., Lo, B., Miao, F., Li, Y., Liu, J., & Zhang, Y.-T. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2620995 · Cited by 181
Self-citationAn Armband Wearable Device for Overnight and Cuff-Less Blood Pressure Measurement
Zheng, Y.-L., Yan, B. P., Zhang, Y.-T., & Poon, C. C. Y. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2318779 · Cited by 177
Self-citationMuehlsteff, J., Aubert, X. L., & Schuett, M. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260275 · Cited by 134
The vascular impact of aging andvasoactive drugs: comparison of twodigital volume pulse measurements
Millasseau, S., Kelly, R. P., Ritter, J. M., & Chowienczyk, P. J. (2003) · American Journal of Hypertension · doi:10.1016/s0895-7061(03)00569-7 · Cited by 113
Liu, Q., Yan, B. P., Yu, C.-M., Zhang, Y.-T., & Poon, C. C. Y. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2286998 · Cited by 109
Self-citationFinger arterial pressure measurement with Finapres.
Wesseling, K. H. (1996) · PubMed · Cited by 105
Relationships ol Pulse Transmission Times to Pre‐ejection Period and Blood Pressure
Newlin, D. B. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb03042.x · Cited by 89
Coefficient-Free Blood Pressure Estimation Based on Pulse Transit Time–Cuff Pressure Dependence
Forouzanfar, M., Ahmad, S., Batkin, I., Dajani, H. R., Groza, V. Z., & Bolic, M. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2243148 · Cited by 80
Wong, M. Y. M., Pickwell‐MacPherson, E., Zhang, Y., & Cheng, J. C. Y. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1626-0 · Cited by 80
Self-citationMcCarthy, B. M., Vaughan, C. J., O’Flynn, B., Mathewson, A., & Mathúna, C. Ó. (2013) · Journal of Human Hypertension · doi:10.1038/jhh.2013.41 · Cited by 80
Challenges and Opportunities in Cardiovascular Health Informatics
Zhang, Y., Zheng, Y.-L., Lin, W.-H., Zhang, H., & Zhou, X.-L. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2244892 · Cited by 63
Self-citationBeat-to-beat ambulatory blood pressure estimation based on random forest
He, R., Huang, Z., Ji, L., Wu, J., Li, H., & Zhang, Z. (2016) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2016.7516258 · Cited by 62
Noninvasive and cuffless measurements of blood pressure for telemedicine
Chan, K. W., Hung, K., & Zhang, Y. T. (2005) · 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2001.1019611 · Cited by 61
Self-citationDing, X., Zhang, Y., & Tsang, H. K. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/2/227 · Cited by 55
Self-citationFeature Selection Method for Estimating Systolic Blood Pressure Using the Taguchi Method
Suzuki, A., & Ryu, K. (2014) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2013.2288498 · Cited by 46
Kim, J. Y., Cho, B. H., Im, S. M., Jeon, M.-J., Kim, I. Y., & Kim, S. I. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616102 · Cited by 45
Suzuki, S., & Oguri, K. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649409 · Cited by 38
Using Individualized Pulse Transit Time Calibration to Monitor Blood Pressure During Exercise
cheol, J. I., Jeffrey, W., & Finkelstein, J. (2013) · Studies in health technology and informatics · doi:10.3233/978-1-61499-276-9-39 · Cited by 17
A new methodology of continuous and noninvasive blood pressure measurement by pulse wave velocity
Chen, Y., Wen, C., Tao, G., & Bi, M. (2010) · International Conference on Control, Automation, Robotics and Vision (ICARCV) · doi:10.1109/icarcv.2010.5707813 · Cited by 16
Parameters for mean blood pressure estimation based on electrocardiography and photoplethysmography
Špulák, D., Čmejla, R., & Fabián, V. (2011) · International Conference on Applied Electronics · Cited by 14
Uangpairoj, P., & Shibata (2013) · Vascular Health and Risk Management · doi:10.2147/vhrm.s43784 · Cited by 14
Cited by
El-Hajj, C., & Kyriacou, P. A. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.101870 · Cited by 294
Wearable Sensing and Telehealth Technology with Potential Applications in the Coronavirus Pandemic
Ding, X., Clifton, D., Ji, N., Lovell, N. H., Bonato, P., Chen, W., Yu, X., Xue, Z., Xiang, T., Long, X., et al. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2992838 · Cited by 281
“estimation to develop regression models between signal features and BP, and demonstrating promising estimation accuracy [115-120].”
Self-citationLong-term blood pressure prediction with deep recurrent neural networks
Su, P., Ding, X.-R., Zhang, Y.-T., Liu, J., Miao, F., & Zhao, N. (2018) · 2018 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI) · doi:10.1109/bhi.2018.8333434 · Cited by 203
“Existing methods for cuffless and continuous BP estimation can be categorized into two groups, namely physiological model, i.e., pulse transit time model [3] [4], and regression model, such as decision tree, support vector regression and etc [5] [6].”
MethodSelf-citationHuynh, T. H., Jafari, R., & Chung, W.-Y. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2865751 · Cited by 178
“To address this challenge, as in some investigations [15], [31], [32], PTT is”
MethodKhalid, S. G., Zhang, J., Chen, F., & Zheng, D. (2018) · Journal of Healthcare Engineering · doi:10.1155/2018/1548647 · Cited by 171
“Previous research only presented overall BP accuracies (overall mean of Journal of Healthcare Engineering difference ± SD of difference) rather than individual categorical BP accuracies [3, 9, 36].”
Background
Metadata
- Authors
- Miao, F., Fu, N., Zhang, Y.-T., Ding, X.-R., Hong, X., He, Q., & Li, Y.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2017-11
- Volume
- 21
- Issue
- 6
- Pages
- 1730-1740
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2608498389
- Cited by
- 174
- References
- 45
- FWCI
- 7.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.