Mueller Matrix Polarimetry—An Emerging New Tool for Characterizing the Microstructural Feature of Complex Biological Specimen
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Recently, with the emergence of new light sources, polarization devices, and detectors, together with a prominent increase in data processing capability, polarization techniques find more and more applications in various areas, one of which is biomedicine. For probing the characteristic features of complex biomedical specimen, Mueller matrix polarimetry has demonstrated distinctive advantages. Mueller matrix polarimetry can be achieved on other optical techniques by adding the polarization state generator and analyzer to their existing optical paths appropriately. Common biomedical optical equipment, such as microscopes and endoscopes, can be upgraded to fulfill Mueller matrix imaging and measurement abilities. Compared with traditional non-polarization optical methods, Mueller matrix polarimetry can provide far more information to characterize the samples, including the anisotropic optical properties, such as birefringence and diattenuation, as well as the distinctive features of various scattering particles and microstructures. Also, Mueller matrix polarimetry is more sensitive to scattering by sub-wavelength microstructures. As a label-free and non-invasive tool, Mueller matrix polarimetry has broad application prospects in biomedical studies and clinical diagnosis. In this review, we provide an introduction to the Mueller matrix methodology, including the Stokes-Mueller formalism, and also the decomposition and transformation methods to derive new parameters. We also summarize the status of the Mueller matrix polarimetric field, including recent improvements, both in instrumentation and data analysis. The current and future applications of Mueller matrix polarimetry in biomedicine are provided and discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interpretation of Mueller matrices based on polar decomposition
Lu, S.-Y., & Chipman, R. A. (1996) · Journal of the Optical Society of America A · doi:10.1364/josaa.13.001106 · Cited by 1,409 · cited 1×
“Among the available decomposition schemes, the Lu-Chipman decomposition describes tissue-like media appropriately, thus is prevalent in biomedical polarimetric studies [25].”
BackgroundImaging skin pathology with polarized light
Jacques, S. L., Ramella-Roman, J. C., & Lee, K. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1484498 · Cited by 582 · cited 1×
“applied DOP to the detections of human skin basal cell carcinoma, squamous cell carcinoma tissues and so on [67], [68].”
MethodPolarized light interaction with tissues
Tuchin, V. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071114 · Cited by 384 · cited 1×
“ing capability, polarization techniques are attracting more and more attention in various areas, one of which is biomedicine [1]–[6].”
BackgroundGil, J. J. (2007) · The European Physical Journal Applied Physics · doi:10.1051/epjap:2007153 · Cited by 272
Mueller polarimetric imaging for surgical and diagnostic applications: a review
Qi, J., & Elson, D. S. (2017) · Journal of Biophotonics · doi:10.1002/jbio.201600152 · Cited by 268
Depolarization and Polarization Indices of an Optical System
Gil, J. J., & Bernabeu, E. (1986) · Optica Acta: International Journal of Optics · doi:10.1080/713821924 · Cited by 251 · cited 1×
“Besides, Gil and Bernabeu also proposed the well-known depolarization-index (DI) [43], [44] as:”
BackgroundPolarized Light and the Mueller Matrix Approach
Gil, J. J., & Ossikovski, R. (2017) · doi:10.1201/b19711 · Cited by 212
Diffuse backscattering Mueller matricesof highly scattering media
Hielscher, A., Eick, A., Mourant, J., Shen, D., Freyer, J., & Bigio, I. (1997) · Optics Express · doi:10.1364/oe.1.000441 · Cited by 183
Morio, J., & Goudail, F. (2004) · Optics Letters · doi:10.1364/ol.29.002234 · Cited by 117
Research works printed but not linked: 125
- 10.1364/OL.37.001061 · DOI
- 10.1364/BOE.5.004223 · DOI · Paper page
- 10.1364/OE.21.014120 · DOI · Paper page
- 10.1515/plm-2012-0052 · DOI
- he, 0, Transformation of full 4 × 4 Mueller matrices: A quantitative technique for biomedical diagnosis, Proc SPIE, 9707, 97070k
- 10.1117/1.JBO.20.6.065003 · DOI
- 10.1364/OL.39.000243 · DOI
- 10.1117/1.JBO.19.4.046020 · DOI
- 10.1364/OE.17.001600 · DOI
- 10.1117/1.JBO.18.4.046014 · DOI · Paper page
- 10.1364/JOSAA.34.000410 · doi:10.1364/josaa.34.000410
- 10.1063/1.3116129 · DOI
- 10.1364/OE.14.009324 · DOI · Paper page
- 10.1364/OL.37.000220 · DOI
- 10.1117/1.JBO.17.10.105006 · DOI
- 10.1364/OE.20.001151 · DOI
- 10.1016/j.optcom.2009.10.111 · DOI
- 10.1038/375254a0 · DOI
- 10.1117/1.2960934 · DOI · Paper page
- 10.1117/1.2397574 · DOI
- 10.1007/BF01271498 · DOI · Paper page
- 10.1038/328452a0 · doi:10.1038/328452a0
- 10.1117/1.JBO.21.7.071112 · DOI · Paper page
- 10.1016/j.micron.2015.07.014 · DOI
- 10.1364/AO.53.002236 · doi:10.1364/ao.53.002236
- 10.1364/BOE.8.003643 · DOI
- 10.1038/72692 · doi:10.1038/72692
- 10.1093/humrep/16.7.1464 · doi:10.1093/humrep/16.7.1464
- 10.1038/381811a0 · doi:10.1038/381811a0
- 10.1016/S0006-3495(91)82092-6 · doi:10.1016/s0006-3495(91)82092-6
- 10.1364/AO.53.002949 · DOI
- 10.1117/1.1489434 · DOI
- 10.1117/1.3652896 · DOI · Paper page
- 10.1117/1.JBO.21.7.071001 · doi:10.1117/1.jbo.21.7.071001
- 10.1007/978-3-540-45321-5 · doi:10.1007/978-3-540-45321-5
- 10.1038/nm1101-1245 · DOI · Paper page
- 10.1117/12.138793 · DOI
- 10.1038/nm.2138 · DOI · Paper page
- 10.1117/1.JBO.20.6.061104 · DOI · Paper page
- 10.1364/OL.2.000148 · DOI · Paper page
- liu, 0, Mueller matrix microscopy meets with machine learning on glaucoma post-operative fibrosis scar tissue discrimination, Invest Ophth Vis Sci
- 10.1364/JOSAA.7.000693 · doi:10.1364/josaa.7.000693
- 10.1364/AO.31.006676 · DOI · Paper page
- 10.1364/OE.26.003791 · DOI
- 10.1364/JOSAA.33.000052 · DOI
- 10.1080/713821732 · DOI · Paper page
- 10.1364/OE.18.010200 · DOI · Paper page
- 10.1117/1.3065545 · DOI
- 10.1364/AO.46.003038 · DOI · Paper page
- novikova, 2014, The origins of polarimetric image contrast between healthy and cancerous human colon tissue, Appl Phys Lett, 102
- 10.1364/AO.38.003399 · DOI · Paper page
- 10.1364/OL.23.000485 · DOI
- 10.1038/s41598-017-02645-9 · DOI
- 10.1364/OL.35.002323 · DOI
- 10.1364/BOE.2.001836 · DOI
- 10.1117/1.1781667 · DOI
- 10.1364/AO.45.004669 · DOI
- 10.1117/12.2290592 · DOI
- 10.1007/s11082-005-4199-0 · DOI
- 10.1117/1.2363347 · doi:10.1117/1.2363347
- 10.1117/1.JBO.19.7.076013 · DOI · Paper page
- 10.1002/jbio.201600008 · doi:10.1002/jbio.201600008
- 10.1016/j.jhep.2014.02.015 · DOI · Paper page
- 10.1364/OE.15.003998 · doi:10.1364/oe.15.003998
- 10.1038/s41598-017-14804-z · DOI
- 10.1117/1.2234278 · DOI
- 10.1117/1.JBO.19.10.106007 · DOI
- 10.1117/1.JBO.21.5.056002 · DOI
- 10.1117/1.JBO.23.1.016007 · DOI
- 10.1117/1.JBO.17.11.116001 · doi:10.1117/1.jbo.17.11.116001
- 10.1364/OE.23.004357 · DOI
- 10.1001/archderm.127.7.1000 · doi:10.1001/archderm.127.7.1000 · Paper page
- 10.1364/AO.37.003586 · DOI · Paper page
- 10.1002/(SICI)1096-9101(2000)26:2<119::AID-LSM3>3.0.CO;2-Y · DOI · Paper page
- 10.1002/jbio.201400104 · DOI · Paper page
- jacques, 0, Polarized light camera to guide surgical excision of skin cancers, Proc SPIE, 6842, 68420i(1?7)
- 10.1364/BOE.5.003562 · DOI
- 10.1364/JOSAB.9.000903 · DOI · Paper page
- 10.1016/S0006-3495(02)75673-7 · DOI · Paper page
- 10.1103/PhysRevLett.80.627 · DOI · Paper page
- 10.1117/1.1431967 · DOI · Paper page
- 10.1038/35017638 · DOI · Paper page
- 10.1364/AO.10.002350 · doi:10.1364/ao.10.002350
- 10.1364/OE.21.015475 · DOI
- lundblad, 1996, Fluorescence polarization analysis of protein-DNA and protein-protein interactions, Mol Endocrinol, 10, 607
- chen, 0, A colinear backscattering Mueller matrix microscope for reflection Muller matrix imaging, Proc Conf Opt Biopsy XVI Toward Real-Time Spectroscopic Imag Diagnosis Int Soc Opt Photon, 10489, 1048901-1?1048901-10
- 10.1002/jemt.20418 · DOI
- 10.1364/BOE.8.003559 · DOI
- 10.1117/1.2435710 · DOI
- 10.1364/OL.29.002010 · DOI
- 10.1364/BOE.6.003475 · doi:10.1364/boe.6.003475
- 10.1364/BOE.7.004054 · DOI
- campbell, 2018, Polarization-resolved second harmonic generation imaging of human ovarian cancer, J Biomed Opt, 23
- 10.1117/1.1509752 · DOI · Paper page
- 10.1117/1.2841024 · doi:10.1117/1.2841024
- 10.1364/OL.27.000101 · DOI · Paper page
- 10.1364/AO.42.005191 · doi:10.1364/ao.42.005191
- 10.1117/1.JBO.18.4.046002 · DOI
- goldstein, 2016, Polarized Light
- 10.1364/JOSA.68.001756 · DOI · Paper page
- 10.1364/BOE.4.002433 · DOI
- 10.1364/OL.36.002429 · DOI
- 10.1364/OE.9.000254 · DOI
- 10.1364/BOE.7.001116 · DOI
- 10.1364/OL.36.001942 · DOI
- 10.1117/1.1483315 · DOI · Paper page
- 10.1364/OL.36.002330 · DOI · Paper page
- 10.1117/1.JBO.17.12.126016 · DOI
- 10.1038/srep25953 · DOI
- 10.1364/OL.37.000578 · DOI
- 10.1364/OE.17.016590 · doi:10.1364/oe.17.016590
- 10.1364/AO.36.000150 · DOI · Paper page
- 10.1364/OE.7.000023 · DOI
- 10.1364/BOE.7.001160 · DOI
- 10.1103/PhysRevE.75.032501 · doi:10.1103/physreve.75.032501
- 10.1364/BOE.6.002934 · DOI
- 10.1117/1.JBO.21.7.071106 · DOI
- 10.1117/1.JBO.21.8.081209 · DOI
- 10.1364/OE.23.023768 · DOI
- 10.1109/TIM.2018.2803847 · DOI
- 10.1117/1.JBO.20.10.105009 · DOI
- 10.1142/S1793545813500284 · doi:10.1142/s1793545813500284
- 10.1364/OE.18.015104 · DOI · Paper page
- 10.1117/1.JBO.19.6.065001 · DOI
- 10.1364/OE.21.018361 · DOI
Cited by
Polarisation optics for biomedical and clinical applications: a review
He, C., He, H., Chang, J., Chen, B., Ma, H., & Booth, M. J. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00639-x · Cited by 604
Self-citationWang, H., Liao, R., Xiong, Z., Wang, Z., Li, J., Zhou, Q., Tao, Y., & Ma, H. (2022) · Biosensors · doi:10.3390/bios12030176 · Cited by 10
“Polarized light-scattering measurement, as an emerging technique, has been applied to characterize muscle tissue [15] and aerosol particles [16].”
MethodSelf-citation
Metadata
- Authors
- He, H., Liao, R., Zeng, N., Li, P., Chen, Z., Liu, X., & Ma, H.
- Venue
- Journal of Lightwave Technology
- Published
- 2019-06-01
- Volume
- 37
- Issue
- 11
- Pages
- 2534-2548
- ISSN
- 0733-8724 (ISSN-L)
- 1558-2213
- OpenAlex
- W2892267886
- Cited by
- 204
- References
- 9
- FWCI
- 4.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Funders
- National Natural Science Foundation of China (61405102, 61527826, 41475125, 11174178, 11374179, 10974114, 60778044, 60578003, 61205199, 41106034)
- National Key Research and Development Program of China (2016YFF0103000, 2016YFC0208600)
- Science and Technology Project of Shenzhen (JCYJ20170412170814624, GJHZ20150316160614844)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.