The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Microfluidics meets MEMS
Abstract
The use of planar fluidic devices for performing small-volume chemistry was first proposed by analytical chemists, who coined the term "miniaturized total chemical analysis systems" (μTAS) for this concept. More recently, the μTAS field has begun to encompass other areas of chemistry and biology. To reflect this expanded scope, the broader terms "microfluidics" and "lab-on-a-chip" are now often used in addition to μTAS. Most microfluidics researchers rely on micromachining technologies at least to some extent to produce microflow systems based on interconnected micrometer-dimensioned channels. As members of the microelectromechanical systems (MEMS) community know, however, one can do more with these techniques. It is possible to impart higher levels of functionality by making features in different materials and at different levels within a microfluidic device. Increasingly, researchers have considered how to integrate electrical or electrochemical function into chips for purposes as diverse as heating, temperature sensing, electrochemical detection, and pumping. MEMS processes applied to new materials have also resulted in new approaches for fabrication of microchannels. This review paper explores these and other developments that have emerged from the increasing interaction between the MEMS and microfluidics worlds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Miniaturized total chemical analysis systems: A novel concept for chemical sensing
Manz, A., Graber, N., & Widmer, H. M. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80209-i · Cited by 3,122
Silicon as a mechanical material
Petersen, K. E. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12331 · Cited by 2,902
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Fundamentals of Microfabrication
(2016) · Micromechatronics · doi:10.1201/b15830-17 · Cited by 2,109
Fundamentals of Microfabrication
Madou, M. J. (2018) · CRC Press eBooks · doi:10.1201/9781482274004 · Cited by 2,020
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
A gas chromatographic air analyzer fabricated on a silicon wafer
Terry, S. C., Jerman, J. H., & Angell, J. B. (1979) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1979.19791 · Cited by 1,452
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
Micromachined Transducers Sourcebook
Kovacs, G. T. A. (1998) · Cited by 1,200
Becker, H. (2002) · Talanta · doi:10.1016/s0039-9140(01)00594-x · Cited by 1,187
Microreaction engineering — is small better?
Jensen, K. F. (2001) · Chemical Engineering Science · doi:10.1016/s0009-2509(00)00230-x · Cited by 1,124
Three-dimensional micro-channel fabrication in polydimethylsiloxane (PDMS) elastomer
Jo, B.-H., Van Lerberghe, L. M., Motsegood, K. M., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.825780 · Cited by 1,098
Manz, A., Harrison, D. J., Verpoorte, E. M. J., Fettinger, J. C., Paulus, A., Lüdi, H., & Widmer, H. M. (1992) · Journal of Chromatography A · doi:10.1016/0021-9673(92)80293-4 · Cited by 1,042
Self-citationSU-8: a low-cost negative resist for MEMS
Lorenz, H., Despont, M., Fahrni, N., LaBianca, N., Renaud, P., & Vettiger, P. (1997) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/7/3/010 · Cited by 979
Hydrodynamic Focusing on a Silicon Chip: Mixing Nanoliters in Microseconds
Knight, J. B., Vishwanath, A., Brody, J. P., & Austin, R. H. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.3863 · Cited by 887
Polymer microfabrication methods for microfluidic analytical applications
Becker, H., & Gärtner, C. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<12::aid-elps12>3.0.co;2-7 · Cited by 795
Anderson, J. R., Chiu, D. T., Jackman, R. J., Cherniavskaya, O., McDonald, J. C., Wu, H., Whitesides, S. H., & Whitesides, G. M. (2000) · Analytical Chemistry · doi:10.1021/ac9912294 · Cited by 698
Jacobson, S. C., Hergenroder, R., Koutny, L. B., Warmack, R. J., & Ramsey, J. M. (1994) · Analytical Chemistry · doi:10.1021/ac00079a028 · Cited by 669
Effenhauser, C. S., Bruin, G. J. M., Paulus, A., & Ehrat, M. (1997) · Analytical Chemistry · doi:10.1021/ac9703919 · Cited by 640
High-aspect-ratio, ultrathick, negative-tone near-UV photoresist and its applications for MEMS
Lorenz, H., Despont, M., Fahrni, N., Brugger, J., Vettiger, P., & Renaud, P. (1998) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(98)80055-1 · Cited by 573
Johnson, T. J., Ross, D., & Locascio, L. E. (2002) · Analytical Chemistry · doi:10.1021/ac010895d · Cited by 547
Fabrication of Plastic Microfluid Channels by Imprinting Methods
Martynova, L., Locascio, L. E., Gaitan, M., Kramer, G. W., Christensen, R. G., & MacCrehan, W. A. (1997) · Analytical Chemistry · doi:10.1021/ac970558y · Cited by 533
Microfluidic chips for clinical and forensic analysis
Verpoorte, E. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200203)23:5<677::aid-elps677>3.0.co;2-8 · Cited by 526
Self-citationUV Laser Machined Polymer Substrates for the Development of Microdiagnostic Systems
Roberts, M. A., Rossier, J. S., Bercier, P., & Girault, H. (1997) · Analytical Chemistry · doi:10.1021/ac961038q · Cited by 497
Klank, H., Kutter, J. P., & Geschke, O. (2002) · Lab on a Chip · doi:10.1039/b206409j · Cited by 477
Printing meets lithography: Soft approaches to high-resolution patterning
Michel, B., Bernard, A., Bietsch, A., Delamarche, E., Geissler, M., Juncker, D., Kind, H., Renault, J.-P., Rothuizen, H., Schmid, H., et al. (2001) · IBM Journal of Research and Development · doi:10.1147/rd.455.0697 · Cited by 471
High-Speed Separations on a Microchip
Jacobson, S. C., Hergenroder, R., Koutny, L. B., & Ramsey, J. M. (1994) · Analytical Chemistry · doi:10.1021/ac00079a029 · Cited by 450
Microfabricated Multiphase Packed-Bed Reactors: Characterization of Mass Transfer and Reactions
Losey, M. W., Schmidt, M. A., & Jensen, K. F. (2001) · Industrial & Engineering Chemistry Research · doi:10.1021/ie000523f · Cited by 446
Autonomous Microfluidic Capillary System
Juncker, D., Schmid, H., Drechsler, U., Wolf, H., Wolf, M., Michel, B., de Rooij, N., & Delamarche, E. (2002) · Analytical Chemistry · doi:10.1021/ac0261449 · Cited by 426
Self-citationAn Integrated Fluorescence Detection System in Poly(dimethylsiloxane) for Microfluidic Applications
Chabinyc, M. L., Chiu, D. T., McDonald, J. C., Stroock, A. D., Christian, J. F., Karger, A. M., & Whitesides, G. M. (2001) · Analytical Chemistry · doi:10.1021/ac010423z · Cited by 419
Chip-based microsystems for genomic and proteomic analysis
Sanders, G. H. W., & Manz, A. (2000) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(00)00011-x · Cited by 366
Negative photoresists for optical lithography
Shaw, J. M., Gelorme, J. D., LaBianca, N. C., Conley, W. E., & Holmes, S. J. (1997) · IBM Journal of Research and Development · doi:10.1147/rd.411.0081 · Cited by 345
Arora, A., Eijkel, J. C. T., Morf, W. E., & Manz, A. (2001) · Analytical Chemistry · doi:10.1021/ac0100300 · Cited by 329
Liu, Y., Fanguy, J. C., Bledsoe, J. M., & Henry, C. S. (2000) · Analytical Chemistry · doi:10.1021/ac000932l · Cited by 293
Emrich, C. A., Tian, H., Medintz, I. L., & Mathies, R. A. (2002) · Analytical Chemistry · doi:10.1021/ac020236g · Cited by 284
Electroosmotic pumping and electrophoretic separations for miniaturized chemical analysis systems
Manz, A., Effenhauser, C. S., Burggraf, N., Harrison, D. J., Seiler, K., & Fluri, K. (1994) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/4/4/010 · Cited by 277
A microfabricated device for sizing and sorting DNA molecules
Chou, H.-P., Spence, C., Scherer, A., & Quake, S. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.1.11 · Cited by 274
Paegel, B. M., Emrich, C. A., Wedemayer, G. J., Scherer, J. R., & Mathies, R. A. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.012608699 · Cited by 263
Simpson, P. C., Roach, D., Woolley, A. T., Thorsen, T., Johnston, R., Sensabaugh, G. F., & Mathies, R. A. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.5.2256 · Cited by 234
Design and fabrication of microfluidic devices for multiphase mixing and reaction
Losey, M. W., Jackman, R. J., Firebaugh, S. L., Schmidt, M. A., & Jensen, K. F. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.803416 · Cited by 232
A miniature integrated device for automated multistep genetic assays
Anderson, R. C. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e60 · Cited by 227
Dodge, A., Fluri, K., Verpoorte, E., & de Rooij, N. F. (2001) · Analytical Chemistry · doi:10.1021/ac0015366 · Cited by 199
Self-citationNovel method of cell fusion in field constriction area in fluid integration circuit
Masuda, S., Washizu, M., & Nanba, T. (1989) · IEEE Transactions on Industry Applications · doi:10.1109/28.31255 · Cited by 190
Linder, V., Verpoorte, E., Thormann, W., de Rooij, N. F., & Sigrist, H. (2001) · Analytical Chemistry · doi:10.1021/ac010421e · Cited by 173
Self-citationReplication techniques for diffractive optical elements
Gale, M. T. (1997) · Microelectronic Engineering · doi:10.1016/s0167-9317(97)00189-5 · Cited by 172
Enzyme linked immunosorbent assay on a microchip with electrochemical detection
Rossier, J. S., & Girault, H. H. (2001) · Lab on a Chip · doi:10.1039/b104772h · Cited by 164
Christel, L. A., Petersen, K., McMillan, W., & Northrup, M. A. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2798037 · Cited by 160
A dc Microplasma on a Chip Employed as an Optical Emission Detector for Gas Chromatography
Eijkel, J. C. T., Stoeri, H., & Manz, A. (2000) · Analytical Chemistry · doi:10.1021/ac991380d · Cited by 159
A Molecular Emission Detector on a Chip Employing a Direct Current Microplasma
Eijkel, J. C. T., Stoeri, H., & Manz, A. (1999) · Analytical Chemistry · doi:10.1021/ac990257j · Cited by 144
Schwarz, M. A., Galliker, B., Fluri, K., Kappes, T., & Hauser, P. C. (2001) · The Analyst · doi:10.1039/b007383k · Cited by 122
Martin, R. S., Gawron, A. J., Lunte, S. M., et al. (2001) · The Analyst · doi:10.1039/b009827m · Cited by 122
Performance of an Integrated Microoptical System for Fluorescence Detection in Microfluidic Systems
Roulet, J.-C., Völkel, R., Herzig, H. P., Verpoorte, E. M. J., de Rooij, N. F., & Dändliker, R. (2002) · Analytical Chemistry · doi:10.1021/ac0112465 · Cited by 99
Self-citationDesign and Rapid Prototyping of Thin-Film Laminate-Based Microfluidic Devices
Weigl, B. H., Bardell, R. L., Schulte, T., Battrell, F., & Hayenga, J. W. (2001) · Biomedical Microdevices · doi:10.1023/a:1012448412811 · Cited by 97
Chemical sensing using an integrated microfluidic system based on the Berthelot reaction
Daridon, A., Sequeira, M., Pennarun-Thomas, G., Dirac, H., Krog, J. P., Gravesen, P., Lichtenberg, J., Diamond, D., Verpoorte, E. M. J., & de Rooij, N. F. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00573-1 · Cited by 93
Self-citationKikutani, Y., Hibara, A., Uchiyama, K., Hisamoto, H., Tokeshi, M., & Kitamori, T. (2002) · Lab on a Chip · doi:10.1039/b208383n · Cited by 92
Polymer microfabrication methods for microfluidic analytical applications
Becker, H., & Gärtner, C. (2000) · Electrophoresis · Cited by 86
Three-dimensional micro flow manifolds for miniaturized chemical analysis systems
Verpoorte, E. M. J., van der Schoot, B. H., Jeanneret, S., et al. (1994) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/4/4/009 · Cited by 84
Self-citationAn array of Pt-tip microelectrodes for extracellular monitoring of activity of brain slices.
Thiebaud, P., Beuret, C., Koudelka-Hep, M., Bove, M., Martinoia, S., Grattarola, M., Jahnsen, H., Rebaudo, R., Balestrino, M., Zimmer, J., et al. (1999) · Biosensors & bioelectronics · doi:10.1016/s0956-5663(98)00098-0 · Cited by 68
Development of Plastic Microfluidic Devices for Sample Preparation
Grodzinski, P. A., Liu, R. H., Chen, B., et al. (2001) · Biomedical Microdevices · doi:10.1023/a:1012400629650 · Cited by 47
Ueno, Y., Horiuchi, T., Tomita, M., Niwa, O., Zhou, H. S., Yamada, T., & Honma, I. (2002) · Analytical Chemistry · doi:10.1021/ac0201732 · Cited by 38
Medintz, I. L., Berti, L., Emrich, C. A., Tom, J. A., Scherer, J. R., & Mathies, R. A. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.9.1614 · Cited by 38
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Wongkaew, N., Simsek, M., Griesche, C., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00172 · Cited by 657
Abgrall, P., & Gué, A.-M. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/5/r01 · Cited by 561
Microfluidic Chips for Point‐of‐Care Immunodiagnostics
Gervais, L., de Rooij, N., & Delamarche, E. (2011) · Advanced Materials · doi:10.1002/adma.201100464 · Cited by 491
Self-citationLab-on-a-chip devices: How to close and plug the lab?
Temiz, Y., Lovchik, R. D., Kaigala, G. V., & Delamarche, E. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2014.10.013 · Cited by 475
Metadata
- Authors
- Verpoorte, E., & De Rooij, N. F.
- Venue
- Proceedings of the IEEE
- Published
- 2003-06
- Volume
- 91
- Issue
- 6
- Pages
- 930-953
- ISSN
- 0018-9219 (ISSN-L)
- OpenAlex
- W2127538459
- Cited by
- 503
- References
- 65
- FWCI
- 25.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.