A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
This paper presents a fully integrated programmable biomedical sensor interface chip dedicated to the processing of various types of biomedical signals. The chip, optimized for high power efficiency, contains a low noise amplifier, a tunable bandpass filter, a programmable gain stage, and a successive approximation register analog-to-digital converter. A novel balanced tunable pseudo-resistor is proposed to achieve low signal distortion and high dynamic range under low voltage operations. A 53 nW, 30 kHz relaxation oscillator is included on-chip for low power consumption and full integration. The design was fabricated in a 0.35 mum standard CMOS process and tested at 1 V supply. The analog front-end has measured frequency response from 4.5 mHz to 292 Hz, programmable gains from 45.6 dB to 60 dB, input referred noise of 2.5 muVrmsin the amplifier bandwidth, a noise efficiency factor (NEF) of 3.26, and a low distortion of less than 0.6% with full voltage swing at the ADC input. The system consumes 445 nA in the 31 Hz narrowband mode for heart rate detection and 895 nA in the 292 Hz wideband mode for ECG recording.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The most common way is to add a low noise amplifier (LNA) to the front end of the recording (Harrison and Charles, 2003; Harrison et al., 2007) and then to add the digital quantization circuits (Zou et al., 2009; Liu et al., 2017; Yu et al., 2018).”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Zou et al., 2009
Citations
Cites
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451 · cited 1×
“power, and area as demonstrated in [4], [5].”
BackgroundAn Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441
A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.894804 · Cited by 382 · cited 3×
“2 [2]–[6].”
BackgroundOlssonIII, R. H., Buhl, D. L., Sirota, A. M., Buzsaki, G., & Wise, K. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847540 · Cited by 181 · cited 1×
“However, the existing tunable pseudo-resistor [7]–[9], as shown in Fig.”
MethodA 128-Channel 6mW Wireless Neural Recording IC with On-the-Fly Spike Sorting and UWB Tansmitter
Chae, M., Liu, W., Yang, Z., Chen, T., Kim, J., Sivaprakasam, M., & Yuce, M. (2008) · 2008 IEEE International Solid-State Circuits Conference - Digest of Technical Papers · doi:10.1109/isscc.2008.4523099 · Cited by 159
A Low-Noise Preamplifier with Adjustable Gain and Bandwidth for Biopotential Recording Applications
Yin, M., & Ghovanloo, M. (2007) · 2007 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2007.378400 · Cited by 129 · cited 1×
“In the single amplifier approach, the bandwidth and gain tuning features are implemented within one closed-loop amplifier [6].”
BackgroundA 1-V 450-nW fully integrated biomedical sensor interface system
Xu, X., Zou, X., Yao, L., & Lian, Y. (2008) · Symposium on VLSI Circuits · doi:10.1109/vlsic.2008.4585959 · Cited by 41 · cited 1×
“interface IC (first presented in [10]).”
Self-citationA low-voltage low-power QFG-based Sigma-Delta modulator for electroencephalogram applications
López-Morillo, E., Carvajal, R. G., Galán, J., Ramirez‐Angulo, J., López‐Martín, A. J., & Rodriguez–Villegas, E. (2006) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2006.4600322 · Cited by 9 · cited 1×
“The OTA incorporates a push-pull output scheme by adopting ( , and ) and ( , and ) [12], where the slew rate is not limited by the quiescent current of the OTA and the driving capability of the OTA is greatly enhanced.”
Background
Research works printed but not linked: 3
- zou, 2008, a 1-v 1.1-<ref_formula><tex notation="tex">$\mu\hbox{w}$</tex> </ref_formula> sensor interface ic for wearable biomedical devices, Proc IEEE Int Symp Circuits and Systems (ISCAS 2008), 2725
- wu, 2006, a 1 v 2.3 <ref_formula><tex notation="tex">$\mu\hbox{w}$</tex> </ref_formula> biomedical signal acquisition ic, IEEE ISSCC Dig Tech Papers, 58
- 1998, Medical Instrumentation Application and Design, 259
Cited by
Items 201–300 of 457
Kandpal, N., Singh, A., & Agarwal, A. (2025) · Integration · doi:10.1016/j.vlsi.2025.102407 · Cited by 8
A High Performance Delta-Sigma Modulator for Neurosensing
Xu, J., Zhao, M., Wu, X., Islam, M., & Yang, Z. (2015) · Sensors · doi:10.3390/s150819466 · Cited by 8
Design optimisation of front-end neural interfaces for spike sorting systems
Barsakcioglu, D. Y., Eftekhar, A., & Constandinou, T. G. (2013) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2013.6572387 · Cited by 8
“27† 1 [5] 0.”
Sharma, K., Pathania, A., Madan, J., Pandey, R., & Sharma, R. (2021) · Circuit World · doi:10.1108/cw-08-2020-0213 · Cited by 8
Design of low frequency analog low pass filter using tunable pseudo resistors
Neshatvar, N., Al-Nashash, H. A., & Albasha, L. (2014) · Middle East Conference on Biomedical Engineering · doi:10.1109/mecbme.2014.6783202 · Cited by 8
An 8-mode reconfigurable sensor-independent readout circuit for trillion sensors era
Musa, A., Minotani, T., Matsunaga, K., Kondo, T., & Morimura, H. (2015) · International Conference on Intelligent Sensors, Sensor Networks and Information Processing · doi:10.1109/issnip.2015.7106913 · Cited by 8
“Such an approach can be used to interface an array of the same sensor for increased measurement accuracy and reliability.”
A digitally trimmable low-noise low-power analog front-end for EEG signal acquisition
Liu, H., Tang, K., Wu, J.-Y., & Wang, G. (2012) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2012.6211547 · Cited by 8
“Some amplifier designs with adjustable gain and bandwidth have been reported recently [6] [7] [8] [9].”
BackgroundLi, H., Zhang, J., & Wang, L. (2012) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2012.20 · Cited by 8
Power and area efficient MOSFET-C filter for very low frequency applications
Tajalli, A., & Leblebici, Y. (2011) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-011-9640-7 · Cited by 8
A pseudo resistor with temperature self-adaptive scheme
Salem, A. M., Wahba, A., Hamed, H. F. A., & Mohamed, A. R. (2024) · Integration · doi:10.1016/j.vlsi.2024.102229 · Cited by 7
A Power Efficient ECG Front-End with Input-Adaptive Gain Reaching 67.6-dB Dynamic Range
Liheng, L., Zhang, Y., Dong, L., Xin, Y., Gao, S., & Geng, L. (2020) · IEEE Asian Solid-State Circuits Conference (A-SSCC) · doi:10.1109/a-sscc48613.2020.9336108 · Cited by 7
“6 demonstrates the schematic of PGA, which is a differential switched-capacitor amplifier based on the flip-overcapacitor architecture [6].”
BackgroundA Programmable Analog Front-End IC Applied for Biomedical Signal Monitoring Systems
Chen, Y., Tang, H., Wang, Z., Xu, P., & Zhuang, Y. (2022) · Circuits Systems and Signal Processing · doi:10.1007/s00034-022-02119-y · Cited by 7
“Moreover, the turn-off resistance of the corresponding control switch in PGA requires a great deal of attention, which may affect the frequency response and reduce the low-frequency amplification bandwidth of PGA, so that the low-frequency signal cannot be effectively amplified [4, 31].”
BackgroundTao, J., Liao, C., Zeng, X., & Li, X. (2015) · IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems · doi:10.1109/tcad.2015.2449240 · Cited by 7
“, biomedical circuits [29], [30], automotive electronics [31], [32], and Internet of things [33], [34]) where mature manufacturing technologies are preferred due to their high reliability and/or low cost.”
BackgroundVamsi, N., Priya, V., Dutta, A., & Singh, S. G. (2016) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2016.7538854 · Cited by 7
“ultra low power wearable bio-medical systems [5] [6] and”
BackgroundDesign of low power CMOS subthreshold current mode instrumentation amplifier based on CCII
Eldeeb, M. A., Ghallab, Y. H., Ismail, Y., & El-Ghitani, H. (2016) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2016.7870137 · Cited by 7
“1 shows some physiological signals with their voltage and frequency conponents; it’s clear that neither high bandwidth nor high voltage headroom are required in bioelectronics [3].”
BackgroundA Power Processing Circuit for Indoor Wi-Fi Energy Harvesting for Ultra-Low Power Wireless Sensors
Kadir, E. B. A., & Hu, A. P. (2017) · Applied Sciences · doi:10.3390/app7080827 · Cited by 7
Ultra-Low Power Application-Specific Integrated Circuits for Sensing
Kassanos, P., Ip, H. M. D., & Yang, G. (2018) · Springer eBooks · doi:10.1007/978-3-319-69748-2_5 · Cited by 7
Flexible Multi-Channel Analog-Frontend for Ultra-Low Power Environmental Sensing
Jotschke, M., Reichel, P., Ossa, W. C., Koh, J., Reich, T., & Mayr, C. (2021) · IEEE Open Journal of Circuits and Systems · doi:10.1109/ojcas.2021.3081250 · Cited by 7
Suo, Y., Han, X., Zhao, Y., Chen, M., Li, Y., Liu, Y., & Lian, Y. (2023) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas46773.2023.10181843 · Cited by 7
“To facilitate the acquisition of ExG signals, tunable bandwidth and gain are necessary [23].”
BackgroundMethodSelf-citationAn ultra low power 9-bit 1-MS/s pipelined SAR ADC for bio-medical applications
Yin, G., Chio, U.-F., Wei, H.-G., Sin, S., Seng‐Pan, U., Martins, R. P., & Wang, Z. (2010) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs.2010.5724652 · Cited by 7
A 300-mV ΔΣ Modulator Using a Gain-Enhanced, Inverter-Based Amplifier for Medical Implant Devices
Yeknami, A. F. (2016) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea6010004 · Cited by 7
“Pacemakers need to sense the cardiac signals, which mainly are situated in very low frequencies from nearly DC to several hundred hertz [3–7].”
BackgroundUltra-low distortion linearized pseudo-RC low-pass filter
Elfaramawy, T., Rezaei, M., Morissette, M., Lellouche, F., & Gosselin, B. J. (2016) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs.2016.7841172 · Cited by 7
“In [7] and [8], a single-transistor common drain voltage follower is used as a level shifter linearizing a bootstrap pseudo resistor, but the dynamic ranges is limited by the imperfections coming from the open loop amplifier.”
BackgroundMethodIto, K., Tani, T., Iwagami, T., Nishino, S., Kiyoyama, K., & Tanaka, T. (2017) · Electronics and Communications in Japan · doi:10.1002/ecj.12021 · Cited by 7
Design of a Programmable Biomedical Front-End Amplifier with Pseudo Resistors
Leung, F.-S., Liu, D., Lai, W., Shiau, M., Wu, H.-C., & Zheng, Z. (2019) · International Symposium on Next-Generation Electronics · doi:10.1109/isne.2019.8896529 · Cited by 7
“Gated Pseudo Resistor with Floationg Gate According to [2][3], Pseudo Resistor with Gate voltage, Fig.”
MethodDumphart, G. (2020) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-b-000445440 · Cited by 7
5 mHz highpass filter with −80 dB total harmonic distortions
Li, H., Zhang, J., & Wang, L. (2012) · Electronics Letters · doi:10.1049/el.2012.0132 · Cited by 6
Design of robust pseudo-resistors with optimized frequency response
Palomeque-Mangut, D., Ausín, J. L., Duque-Carrillo, J. F., & Torelli, G. (2017) · European Conference on Circuit Theory and Design · doi:10.1109/ecctd.2017.8093269 · Cited by 6
A 4×32-Channel Neural Recording System for Deep Brain Stimulation Systems
Kim, S., Na, S.-I., Yang, Y., Kim, H., Kim, T., Cho, J. S., Kim, J.-H., Chang, J. W., & Kim, S. (2017) · JSTS Journal of Semiconductor Technology and Science · doi:10.5573/jsts.2017.17.1.129 · Cited by 6
“To achieve the dynamic range up to 60 dB, the ADC requires at least 10-bit resolution [27].”
BackgroundDutta, A., & Bhattacharyya, T. K. (2011) · International Conference on VLSI Design · doi:10.1109/vlsid.2011.39 · Cited by 6
“There are various hybrid topologies reported for low offset and 1/f noise, (as low as 100nV input offset [5]) but all of them have either very low system bandwidth or low dynamic range [6], [7], [8] .”
BackgroundA Quasi-Delay-Insensitive Dual-Rail low-pass filter working in subthreshold region
Chang, X., & Lian, Y. (2010) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2010.5709609 · Cited by 6
Self-citationPatra, P., Yadav, K., Vamsi, N., & Dutta, A. (2016) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2016.7527548 · Cited by 6
“The bio-potential signal amplitude varies from tens of μV to tens of mV [3].”
BackgroundDesign and Implementation of Tunable Bandpass Filter for Biomedical Applications
Saurabh, B. K., Siddharth, R. K., Kumar, Y. B. N., Patidar, S., & Vasantha, M. H. (2016) · IEEE International Symposium on Nanoelectronic and Information Systems (iNIS) · doi:10.1109/inis.2016.021 · Cited by 6
“Standard CMOS technology based biosensors are widely used in biomedical applications [1].”
BackgroundA current-reuse dual-channel bio-signal amplifier for WBAN nodes
Liu, L., Zhang, Y., Song, Y. J., Zhu, Z., & Yang, Y. (2017) · Microelectronics Journal · doi:10.1016/j.mejo.2017.10.007 · Cited by 6
A VGA Linearity Improvement Technique for ECG Analog Front-End in 65nm CMOS
Nagulapalli, R., Hayatleh, K., & Barker, S. (2019) · Journal of Circuits Systems and Computers · doi:10.1142/s0218126620501133 · Cited by 6
A Design of Cmos based 4th Order Low Pass Biquad Filter for Biomedical Applications
Bagavathiyammal, R., & Muruganantham, T. (2020) · International Conference on Inventive Research in Computing Applications (ICIRCA) · doi:10.1109/icirca48905.2020.9182851 · Cited by 6
A 32-channel neural recording system with a liquid-crystal polymer MEA
Na, S.-I., Kim, S., Kim, T., Lee, H., Lee, H., & Kim, S. (2013) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2013.6679628 · Cited by 6
A highly linear, Sigma-Delta based, sub-Hz high-pass filtered ExG readout system
Mohan, R., Hiseni, S., & Serdijn, W. A. (2013) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2013.6571812 · Cited by 6
“Pseudo-resistors are widely used to integrate large timeconstants [3], [4], [5].”
BackgroundA wearable wireless ECG sensor with real-time QRS detection for continuous cardiac monitoring
Wong, D. L. T., & Lian, Y. (2012) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2012.6418407 · Cited by 6
“This includes ultra-low power ECG acquisition front-end [5], system-on-chip solutions [6], [7].”
BackgroundMethodSelf-citationRout, S., & Serdijn, W. A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2817926 · Cited by 6
“As these transistors are intrinsically non-linear, the resistances vary with the signal level, eventually leading to clipping at the extremes [13].”
BackgroundA 9.6 nW, 8-Bit, 100 S/s Envelope-to-Digital Converter for Respiratory Monitoring
Shi, E., de Godoy, D., Kinget, P. R., & Pun, K. (2019) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2019.2922661 · Cited by 6
Novel Low Noise Amplifier for Neural Signals Based on STT-MTJ Spintronic Device
Pan, G., Karymy, A., Yu, P., & Jiang, Y. (2019) · IEEE Access · doi:10.1109/access.2019.2945036 · Cited by 6
“That is a major factor limiting the dynamic range of the low voltage circuit [23].”
BackgroundLuo, D., Zhang, M., & Wang, Z. (2018) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2018.8357026 · Cited by 6
“For LFPs and APs acquisition applications, with an expectation of uV level input-referred noise for the amplifier and approximately 10-bit ADC resolution, up to 60dB dynamic range is required, which is almost impossible for the pseudoresistor-based structure to achieve, even with an elaborate bias scheme integrated [4…”
MethodSong, J., Wen, K., Ding, R., Chen, M., Liu, S., & Zhu, Z. (2024) · Microelectronics Journal · doi:10.1016/j.mejo.2024.106305 · Cited by 5
Low-Power High Sensitive Capacitance Read-Out Circuit Using a-InGaZnO TFTs
Bhatnagar, P., Bahubalindruni, P. G., & Barquinha, P. M. C. (2021) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas51556.2021.9401699 · Cited by 5
A Floating-Gate-Based Four-Channel Reconfigurable Analog Front-End Integrated Circuit
Lo, Z.-J., Nath, B., Wang, Y.-C., Huang, Y.-J., Huang, H.-C., & Peng, S.-Y. (2021) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas51556.2021.9401325 · Cited by 5
Integrated 16-channel neural recording and stimulation circuit
Kursu, O., Vähäsöyrinki, M., & Rahkonen, T. E. (2015) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-015-0593-0 · Cited by 5
High Linearity and Large Output Swing Sub-Hz Pre-amplifier for Portable Biomedical Applications
Monteiro, M. F. C., Klimach, H., & Bampi, S. (2014) · Symposium on Integrated Circuits and Systems Design · doi:10.1145/2660540.2660975 · Cited by 5
Design optimization for an 8-bit microcontroller in wireless biomédical sensors
Li, Y., Lian, Y., & Pérez, V. (2009) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2009.5372090 · Cited by 5
“Much effort has been made to the improvement of circuits in WWBS devices in the past [1, 2].”
BackgroundSelf-citationAn event-driven SoC for neural recording
Luan, S., Liu, Y., Williams, I. A., & Constandinou, T. G. (2016) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2016.7833817 · Cited by 5
“The 4 th stage amplifier provides tunable gain by changing the capacitor ratio [9].”
BackgroundA reusable stage based reduced comparator count binary search ADC
Dipti, Singh, S. V., Joshi, R., Misra, P. K., & Goswami, M. (2020) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-020-01686-x · Cited by 5
A 90 nm CMOS low noise readout front-end for portable biopotential signal acquisition
Huang, W.-C., & Tang, K. (2012) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2012.6418476 · Cited by 5
A self-calibration method for capacitance mismatch in SAR ADC with split-capacitor DAC
Dai, P., Zhao, Y., Sheng, Y., & Zhang, Y. (2015) · Microelectronics Journal · doi:10.1016/j.mejo.2015.03.011 · Cited by 5
A high CMRR, high resolution bio-ASIC for ECG signals
Garje, K. K., Kumar, S., Tripathi, A. K., Maruthi, G., & Kumar, M. M. (2016) · International Symposium on VLSI Design and Test (VDAT) · doi:10.1109/isvdat.2016.8064890 · Cited by 5
“5-150Hz [4].”
Ultra-low-power biomedical circuit design and optimization: Catching the don't cares
Li, X., Blanton, R. D., Grover, P., & Thomas, D. E. (2014) · International Symposium on Integrated Circuits · doi:10.1109/isicir.2014.7029551 · Cited by 5
“Especially for the implantable applications where power consumption is highly constrained (e.g., less than 100 μW), it is necessary to design an ASIC circuit, instead of relying on general-purpose microprocessors and/or programmable devices such as FPGAs, to meet the tight power budget [22]-[28].”
BackgroundA current mode feed-forward gain control system for a 0.8 V CMOS hearing aid
Li, F., Yang, H., Liu, F., & Yin, T. (2011) · Journal of Semiconductors · doi:10.1088/1674-4926/32/6/065010 · Cited by 5
“With the simplest architecture of amplifierŒ12; 13 applied in the amplifier Av1 and Av2, the minimum power supply can be as low as Vdd;min D Vgs; PMOS C Vgs;NMOS Vth;NMOS: (7) Our design is based on the Chartered 0.13 m standard CMOS process, and its typical threshold voltages of PMOS and NMOS are equal to 400 mV and…”
InfluentialCurrent Mode Feed-Forward Gain Control for 0.8V CMOS hearing aid
Li, F., Yang, H., Wang, Y., & Wu, Q. (2011) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2011.5937685 · Cited by 5
“The phenomenon may attribute to the varied output impedance that sources or sinks the current from the OTA.”
BackgroundInfluentialImpact of parasitic capacitances on the performance of SAR ADCs based on capacitive arrays
Rodríguez‐Pérez, A., Rodríguez-Rodríguez, J. A., Medeiro, F., & Delgado‐Restituto, M. (2010) · IEEE Latin American Symposium on Circuits and Systems (LASCAS) · doi:10.1109/lascas.2010.7410236 · Cited by 5
“Binary weighted arrays with an attenuation capacitor [5][7] and C-2C structures [8]-[10] are the most commonly used alternatives.”
MethodIwagami, T., Tani, T., Ito, K., Nishino, S., Harashima, T., Kino, H., Kiyoyama, K., & Tanaka, T. (2016) · Japanese Journal of Applied Physics · doi:10.7567/jjap.55.04em12 · Cited by 5
Dual-Mode Urinalysis Chip by Using Electrochemical Impedance Spectroscopy
Chen, T.-A., Wei, C., Liu, T.-H., Lin, R.-Y., & Liu, B.-D. (2011) · International Conference on Intelligent Computation and Bio-Medical Instrumentation (ICBMI) · doi:10.1109/icbmi.2011.55 · Cited by 5
“2 shows the IA circuit, whose core is a operational amplifier [7][8].”
BackgroundFully Integrated Analog Front-end for a 2-electrode ECG device
Mohan, R. (2011) · Research Repository (Delft University of Technology) · Cited by 5
Marcelo, V., & Vanesa, F. (2011) · Communities in DSpace (Pontifical Catholic University of Peru) · Cited by 5
Wen, Y., Liu, W., Li, W., Zheng, B., Li, D., & Feng, Q. (2025) · IEICE Electronics Express · doi:10.1587/elex.22.20250097 · Cited by 4
Low Power Analog to Digital Converter for Neuro Stimulator using Cadence Tool
Banu, S., & Gupta, S. (2022) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2325/1/012005 · Cited by 4
A 12-bit 1-MS/s 26-μW SAR ADC for Sensor Applications
Chung, Y., Yen, C., & Tsai, C. (2016) · Physical Sciences Reviews · doi:10.1515/psr-2016-0014 · Cited by 4
“[7] was suitable for low-frequency sensor signals, but not for sophisticated sensor array systems, which have to process high-frequency sensor signals [6].”
BackgroundMethodInfluentialNanopower sub-threshold biquadratic cells and its application to portable ECG system
Bano, S., Narejo, G. B., & Ali, S. M. U. (2019) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2019.05.001 · Cited by 4
Liu, L., Xu, J., Yin, J., Liao, X., & Tian, Y. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3309392 · Cited by 4
“The AFE achieves this using a programmable gain amplifier (PGA) [22], [23], [24], which usually uses capacitive structures because it is relatively simple and leads to low-power dissipation [25], [26].”
MethodStatistical modeling of capacitor mismatch effects for successive approximation register ADCs
Lee, Y., Song, J., & Park, I. (2011) · International SoC Design Conference · doi:10.1109/isocc.2011.6138770 · Cited by 4
A Time-Based Analogue-to-Digital Converter for ECG Applications
Karimlou, A., & Yavari, M. (2021) · Iranian Conference on Electrical Engineering · doi:10.1109/icee52715.2021.9544304 · Cited by 4
The Design of Integrated Circuit for Biomedical and mHealth Application
Cheng, Y., & Li, Y. (2015) · Springer series in bio-/neuroinformatics · doi:10.1007/978-3-319-12817-7_23 · Cited by 4
Jha, P. K., Patra, P., Naik, J., Dutta, A., Acharya, A., Rajalakshmi, P., & Singh, S. G. (2015) · IEEE International New Circuits and Systems Conference (NEWCAS) · doi:10.1109/newcas.2015.7182054 · Cited by 4
“Parameter Value This work [26] [20] [27] Technology (μm) 0.”
BackgroundMethodEnergy efficiency of micropipelines under wide dynamic supply voltages
Baz, A., Shang, D., Xia, F., Gu, X., & Yakovlev, A. (2014) · IEEE Faible Tension Faible Consommation · doi:10.1109/ftfc.2014.6828609 · Cited by 4
Patra, P., Yadav, K., Naik, J., & Dutta, A. (2015) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2015.7373182 · Cited by 4
“Thus for achieving a high linearity, an output swing of 100mV is generally used [3].”
MethodMishra, B., Thakkar, S., & Jain, N. (2019) · IET Computers & Digital Techniques · doi:10.1049/iet-cdt.2019.0027 · Cited by 4
Temperature effect and compensation scheme for tunable ultra-high-resistance pseudo resistor
Mohamed, A. R., & Wang, G. (2020) · Microelectronics Journal · doi:10.1016/j.mejo.2020.104820 · Cited by 4
An ultra‐low‐power, low‐noise tunable electrocardiogram amplifier
Saeidian, F., & Ashraf, M. (2020) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.2867 · Cited by 4
A compact sub-Hertz local field potential amplifier for implantable biomedical devices
Dwivedi, S., & Gogoi, A. K. (2022) · Microelectronics Journal · doi:10.1016/j.mejo.2022.105539 · Cited by 4
Preamplifier Design Strategies for Capacitive Sensing of Electrophysiological Signals
Zhang, Y., Ouzounov, S. F., Meftah, M., Cantatore, E., & Harpe, P. J. A. (2022) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs202256217.2022.9970991 · Cited by 4
A 455 nW 220 fJ/conversion-step 12 bits 2 kS/s SAR ADC for portable biopotential acquisition systems
Zhang, H., Qin, Y., Yang, S., & Hong, Z. (2011) · Journal of Semiconductors · doi:10.1088/1674-4926/32/1/015001 · Cited by 4
A high-gain, low-noise CMOS amplifier for sampled bio-potential recording
Rieger, R., & Huang, Y.-R. (2010) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2010.5537291 · Cited by 4
SAR Analog to Digital Converter for bio-potential signals: A review
Singh, W., Kumar, R., V, & Kumar, M. (2015) · International Conference on Soft Computing Techniques and Implementations (ICSCTI) · doi:10.1109/icscti.2015.7489544 · Cited by 4
Miniaturized Resonant Power Conversion for Implanted Medical Devices
Kumar, V., & Kakkar, V. (2017) · IEEE Access · doi:10.1109/access.2017.2728364 · Cited by 4
“Due to this challenge, energy harvesting methods [1]–[4], [19] are attracting lot of research efforts especially in biomedical implants.”
BackgroundMagneto-Inductive Powering and Uplink of In-Body Microsensors: Feasibility and High-Density Effects
Dumphart, G., Bitachon, B. I., & Wittneben, A. (2019) · IEEE Wireless Communications and Networking Conference · doi:10.1109/wcnc.2019.8885956 · Cited by 4
“450 nW reported in [14]) and that 50% of the excess received power is then used as transmit power in the uplink.”
BackgroundPark, Y., Mo, Y.-J., Kim, J. H., Cauwenberghs, G., & Kim, S. (2025) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2025.3613410 · Cited by 3
“The low-pass corner frequencies were measured as from 140 to 220 Hz, depending on PGA gains, because of the flip-over-capacitor configuration [30].”
A Wide-Dynamic-Range, DC-Coupled, Time-Based Neural-Recording IC With Optimized CCO Frequency
Youn, D., Kim, Y.-I., Choi, I., Jung, Y., Jeon, H., Lee, K., Kweon, S.-J., Ha, S., & Je, M. (2024) · IEEE Access · doi:10.1109/access.2024.3424228 · Cited by 3
“2(a) consists of an instrumentation amplifier (IA) and analog-to-digital converter (ADC) [32], [33], [34], [35], [36], [37], [38], [39], [40], [41], [42], [43], [44], [45], [46], [47], [48], [49], [50], [51], [52], [53], [54], [55], [56], [57], [58], [59], [60], [61], [62], [63], [64], and it can…”
InfluentialNekoui, M., Sodagar, A. M., & Ehsanian, M. (2014) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2014.6981746 · Cited by 3
“This provide the opportunity to replace the MOS pseudoresistors traditionally used to set a very low fCL, which are both nonlinear and vulnerable to process variations [1], [4], [5], with reliable linear circuits comprising standard passive and active components.”
BackgroundMethodDemonstration of a fully differential VGA chip with small THD for ECG acquisition system
Xiao, G., Qin, Y., Xu, W., Wei, B., Duan, J., & Wei, X. (2015) · Journal of Semiconductors · doi:10.1088/1674-4926/36/10/105005 · Cited by 3
“Parameter This work Reference [6] Reference [10] Reference [13] Reference [14]”
BackgroundA 11-bit 1.2V 40.3μW SAR ADC with self-dithering technique
Shuangshuang, Z., Li, T., Jin, L., Yang, J., He, L., & Lin, F. (2016) · IEEE MTT-S International Wireless Symposium (IWS) · doi:10.1109/ieee-iws.2016.7585432 · Cited by 3
“For this reason, SAR ADCs were widely used in fully integrated bio-sensing systems [1, 2].”
MethodZafarkhah, E., Zare, M., Anzabi-Nezhad, N. S., & Sohrabi, Z. (2024) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-023-02246-9 · Cited by 3
Design of a wireless and batteryless heart rate monitor
Sosa, J., & Solar, H. (2017) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2017.8053167 · Cited by 3
“We optimized and implemented the programmable gain amplifier (PGA) presented in [11] using the same 90 nm CMOS technology than the TC–ADC and the RF–Unit.”
MethodA Current-mode pH-Sensor Interface based on Carbon Nanotube Field Effect Transistor
Tripathi, S. K., Ansari, M. S., & Joshi, A. M. (2017) · Materials Today Proceedings · doi:10.1016/j.matpr.2017.06.372 · Cited by 3
Jyoti, J., Pandey, R., & Raghava, N. S. (2023) · Microsystem Technologies · doi:10.1007/s00542-023-05466-1 · Cited by 3
“In (Zou et al. 2009), the author used a low-noise operational transconductance amplifier (LNOTA) for ECG signals.”
MethodIntegrated circuit for neural recording and stimulation
Kursu, O., & Rahkonen, T. E. (2014) · NORCHIP · doi:10.1109/norchip.2014.7004738 · Cited by 3
“Several neural signal recording and stimulation systems have been presented in the literature [1]–[11].”
BackgroundUltra-Low-Power Biomedical Circuit Design and Optimization: Catching the Don’t Cares
Li, X., Blanton, R. D., Grover, P., & Thomas, D. E. (2017) · Springer eBooks · doi:10.1007/978-3-319-54840-1_7 · Cited by 3
Yu, L., Wang, X., & Wang, L. (2010) · Asia Pacific Conference on Postgraduate Research in Microelectronics and Electronics · doi:10.1109/primeasia.2010.5604879 · Cited by 3
Implantable Neural Sensors for Brain Machine Interface
Jang, J., Lee, J.-H., Kang, M., & Song, Y. (2015) · KAIST research series · doi:10.1007/978-94-017-9981-2_3 · Cited by 3
Automatic Patency Discrimination in the Pig Bilateral Femoral Veins for Biomedical Implants
Rothfuss, M. A., Gimbel, M. L., & Sejdić, E. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2765239 · Cited by 3
“in the IBM 130 nm CMOS process and designed for operation with a 1 V supply voltage, which is sufficient for integration into low-voltage wirelessly powered biomedical implants [20], [21], [22].”
MethodA Fully Tunable Low-power Low-noise and High Swing EMG Amplifier with 8.26 PEF
Naderi, K., Shad, E. H. T., Molinas, M., & Heidari, A. (2020) · IEEE International New Circuits and Systems Conference (NEWCAS) · doi:10.1109/newcas49341.2020.9159824 · Cited by 3
“The lower cut-off frequency of the PGA (1/2R2C2) should be much smaller than the TBLNA.”
MethodInfluentialShi, W., Zhang, J., Zhang, Z., Hu, L., & Su, Y. (2020) · Brain Science Advances · doi:10.26599/bsa.2020.9050024 · Cited by 3
Yazıcıoğlu, R. F. (2010) · Integrated circuits and systems · doi:10.1007/978-1-4419-6597-4_4 · Cited by 3
Silicon Integrated High-density Electrocortical and Retinal Neural Interfaces
Ha, S. (2016) · eScholarship (California Digital Library) · Cited by 3
Metadata
- Authors
- Zou, X., Xu, X., Yao, L., & Lian, Y.
- Affiliations
- National University of Singapore (SG)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2009-04
- Volume
- 44
- Issue
- 4
- Pages
- 1067-1077
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2152776190
- Cited by
- 414
- References
- 10
- Citations by year
- 2026: 6 · 2025: 16 · 2024: 16 · 2023: 9 · 2022: 12 · 2021: 22 · 2020: 25 · 2019: 29 · 2018: 27 · 2017: 31 · 2016: 35 · 2015: 35 · 2014: 40 · 2013: 31 · 2012: 29
- FWCI
- 16.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- National University of Singapore (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- low-power analog front-end, low-voltage operation, low noise amplifier, tunable bandpass filter, successive approximation register ADC, relaxation oscillator, heartbeat detection, ECG recording, noise efficiency factor, CMOS integrated circuit
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.