A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
This paper presents a fully integrated programmable biomedical sensor interface chip dedicated to the processing of various types of biomedical signals. The chip, optimized for high power efficiency, contains a low noise amplifier, a tunable bandpass filter, a programmable gain stage, and a successive approximation register analog-to-digital converter. A novel balanced tunable pseudo-resistor is proposed to achieve low signal distortion and high dynamic range under low voltage operations. A 53 nW, 30 kHz relaxation oscillator is included on-chip for low power consumption and full integration. The design was fabricated in a 0.35 mum standard CMOS process and tested at 1 V supply. The analog front-end has measured frequency response from 4.5 mHz to 292 Hz, programmable gains from 45.6 dB to 60 dB, input referred noise of 2.5 muVrmsin the amplifier bandwidth, a noise efficiency factor (NEF) of 3.26, and a low distortion of less than 0.6% with full voltage swing at the ADC input. The system consumes 445 nA in the 31 Hz narrowband mode for heart rate detection and 895 nA in the 292 Hz wideband mode for ECG recording.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The most common way is to add a low noise amplifier (LNA) to the front end of the recording (Harrison and Charles, 2003; Harrison et al., 2007) and then to add the digital quantization circuits (Zou et al., 2009; Liu et al., 2017; Yu et al., 2018).”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Zou et al., 2009
Citations
Cites
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451 · cited 1×
“power, and area as demonstrated in [4], [5].”
BackgroundAn Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441
A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.894804 · Cited by 382 · cited 3×
“2 [2]–[6].”
BackgroundOlssonIII, R. H., Buhl, D. L., Sirota, A. M., Buzsaki, G., & Wise, K. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847540 · Cited by 181 · cited 1×
“However, the existing tunable pseudo-resistor [7]–[9], as shown in Fig.”
MethodA 128-Channel 6mW Wireless Neural Recording IC with On-the-Fly Spike Sorting and UWB Tansmitter
Chae, M., Liu, W., Yang, Z., Chen, T., Kim, J., Sivaprakasam, M., & Yuce, M. (2008) · 2008 IEEE International Solid-State Circuits Conference - Digest of Technical Papers · doi:10.1109/isscc.2008.4523099 · Cited by 159
A Low-Noise Preamplifier with Adjustable Gain and Bandwidth for Biopotential Recording Applications
Yin, M., & Ghovanloo, M. (2007) · 2007 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2007.378400 · Cited by 129 · cited 1×
“In the single amplifier approach, the bandwidth and gain tuning features are implemented within one closed-loop amplifier [6].”
BackgroundA 1-V 450-nW fully integrated biomedical sensor interface system
Xu, X., Zou, X., Yao, L., & Lian, Y. (2008) · Symposium on VLSI Circuits · doi:10.1109/vlsic.2008.4585959 · Cited by 41 · cited 1×
“interface IC (first presented in [10]).”
Self-citationA low-voltage low-power QFG-based Sigma-Delta modulator for electroencephalogram applications
López-Morillo, E., Carvajal, R. G., Galán, J., Ramirez‐Angulo, J., López‐Martín, A. J., & Rodriguez–Villegas, E. (2006) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2006.4600322 · Cited by 9 · cited 1×
“The OTA incorporates a push-pull output scheme by adopting ( , and ) and ( , and ) [12], where the slew rate is not limited by the quiescent current of the OTA and the driving capability of the OTA is greatly enhanced.”
Background
Research works printed but not linked: 3
- zou, 2008, a 1-v 1.1-<ref_formula><tex notation="tex">$\mu\hbox{w}$</tex> </ref_formula> sensor interface ic for wearable biomedical devices, Proc IEEE Int Symp Circuits and Systems (ISCAS 2008), 2725
- wu, 2006, a 1 v 2.3 <ref_formula><tex notation="tex">$\mu\hbox{w}$</tex> </ref_formula> biomedical signal acquisition ic, IEEE ISSCC Dig Tech Papers, 58
- 1998, Medical Instrumentation Application and Design, 259
Cited by
Items 101–200 of 457
A Chopper-Stabilized Amplifier With a Tunable Bandwidth for EEG Acquisition Applications
Lee, C.-J., & Song, J. (2019) · IEEE Access · doi:10.1109/access.2019.2919607 · Cited by 31
“The neural signal amplifiers reported in [7] and [8] changed the low-pass corner frequency by adjusting the corner frequency of a tunable filter or the bandwidth of the amplifier.”
BackgroundA Dynamically Reconfigurable ECG Analog Front-End With a 2.5× Data-Dependent Power Reduction
Mondal, S., Hsu, C.-L., Jafari, R., & Hall, D. A. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3114415 · Cited by 31
Tunable high resistance voltage-controlled pseudo-resistor with wide input voltage swing capability
Shiue, M., Yao, K.-W., & Gong, C.-S. A. (2011) · Electronics Letters · doi:10.1049/el.2010.3286 · Cited by 30
Rodríguez‐Pérez, A., Delgado‐Restituto, M., & Medeiro, F. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2270180 · Cited by 30
“1(a)], not only because of the reduced sampling time [18],”
BackgroundA 0.5-V 1.13-μW/channel neural recording interface with digital multiplexing scheme
Liew, W.-S., Zou, X., & Lian, Y. (2011) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2011.6044946 · Cited by 29
Self-citationA 0.4-V Subnanowatt 8-Bit 1-kS/s SAR ADC in 65-nm CMOS for Wireless Sensor Applications
Harikumar, P., Wikner, J. J., & Alvandpour, A. (2016) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2016.2531099 · Cited by 29
A Biomedical Sensor System With Stochastic A/D Conversion and Error Correction by Machine Learning
Hirai, Y., Matsuoka, T., Tani, S., Isami, S., Tatsumi, K., Ueda, M., & Kamata, T. (2019) · IEEE Access · doi:10.1109/access.2019.2898154 · Cited by 29
“Since the frequency range of biomedical signals is the DC to a few kHz [7], the SARADC can realize low power operations in exchange for low speed operations.”
BackgroundA near-threshold, multi-node, wireless body area sensor network powered by RF energy harvesting
Cheng, J., Xia, L., Ma, C., Lian, Y., Xu, X., Yue, C. P., Hong, Z., & Chiang, P. Y. (2012) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2012.6330681 · Cited by 28
Self-citationShimamura, T., Ugajin, M., Suzuki, K., Ono, K., Sato, N., Kuwabara, K., Morimura, H., & Mutoh, S. (2010) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2010.5433864 · Cited by 28
“On the other hand, the previous works for capacitive-sensing [3-4] and voltage reference [5] consume more than sub-microwatt since they use amplifiers and DCbiased resistors.”
BackgroundSegmented Architecture for Successive Approximation Analog-to-Digital Converters
Saberi, M., & Lotfi, R. (2013) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2013.2246592 · Cited by 27
“One of the most important building blocks that determine the accuracy and conversion speed of the converter and also consumes a major part of the overall power of the SA-ADC (specifically for medium-to-high resolutions) is the DAC [1], [5].”
BackgroundRatiometric Voltage-to-Frequency Converter for Long-Life Autonomous Portable Equipment
Azcona, C., Calvo, B., Celma, S., Medrano, N. J., & Martinez, P. A. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2254595 · Cited by 26
0.6‐V CMOS cascode OTA with complementary gate‐driven gain‐boosting and forward body bias
Cellucci, D., Centurelli, F., Stefano, V. D., Monsurrò, P., Pennisi, S., Scotti, G., & Trifiletti, A. (2019) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.2703 · Cited by 26
“Large R values are needed not to decrease the differential gain, thus they can be implemented using MOS pseudo‐ resistors as in Zou et al.(13)”
MethodStraintronics: A leap toward ultimate energy efficiency of magnetic random access memories
Barangi, M., & Mazumder, P. (2015) · IEEE Nanotechnology Magazine · doi:10.1109/mnano.2015.2441106 · Cited by 26
“leakage is more pronounced in low-speed applications, such as biomedical devices, where the performance is limited to a few megahertz [2].”
BackgroundUltra-low-power circuit techniques for mm-size wireless sensor nodes with energy harvesting
Morimura, H., Oshima, S., Matsunaga, K., Shimamura, T., & Harada, M. (2014) · IEICE Electronics Express · doi:10.1587/elex.11.20142009 · Cited by 25
An ECG-SoC with 535nW/channel lossless data compression for wearable sensors
Deepu, C. J., Zhang, X., Liew, W.-S., Wong, D. L. T., & Lian, Y. (2013) · IEEE Asian Solid-State Circuits Conference (A-SSCC) · doi:10.1109/asscc.2013.6691003 · Cited by 25
Self-citationA 0.5V 1KS/s 2.5nW 8.52-ENOB 6.8fJ/conversion-step SAR ADC for biomedical applications
Lu, T.-C., Van, L.-D., Lin, C.-S., & Huang, C.-M. (2011) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2011.6055325 · Cited by 25
“JSSC’10 [1] JSSC’03 [2] JSSC’09 [3] JSSC’11 [4] ISSCC’11 [5] ISSCC’06 [6] This Work”
A 53-nW 9.12-ENOB 1-kS/s SAR ADC in 0.13-μm CMOS for medical implant devices
Zhang, D., Bhide, A., & Alvandpour, A. (2011) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2011.6045008 · Cited by 25
“22 (24) published SAR ADCs with comparable sampling rates [28]-[30].”
BackgroundLow-Power Low-Noise Pseudo-Open-Loop Preamplifier for Neural Interfaces
Chang, S.-I., Park, S., & Yoon, E. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2717787 · Cited by 25
Bano, S., Narejo, G. B., & Ali, S. M. U. (2019) · Integration · doi:10.1016/j.vlsi.2019.12.003 · Cited by 24
A Low Noise Amplifier for Neural Spike Recording Interfaces
Ruiz-Amaya, J., Rodriguez-Perez, A., & Delgado-Restituto, M. (2015) · Sensors · doi:10.3390/s151025313 · Cited by 23
“Introduction During the last years, there has been a growing interest on the design of implanted neural recording interfaces for the monitoring of brain activity [1–21].”
BackgroundMethodAkgun, Ö. C., Rodrigues, J. N., Leblebici, Y., & Öwall, V. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2157505 · Cited by 22
“Together with a low-power analog-to-digital converter (ADC) [11], digital implementation has the advantage of accommodating more extensive signal processing, such as features for morphology classification (e.g., in implantable cardioverter defibrillators (ICDs) and data compression for postanalysis [12], [13]).”
MethodA bandwidth-tunable bioamplifier with voltage-controlled symmetric pseudo-resistors
Shiue, M., Yao, K., & Gong, C. A. (2015) · Microelectronics Journal · doi:10.1016/j.mejo.2015.03.013 · Cited by 22
A 1-nS 1-V Sub-1-µW Linear CMOS OTA with Rail-to-Rail Input for Hz-Band Sensory Interfaces
Jakusz, J., Jendernalik, W., Blakiewicz, G., Kłosowski, M., & Szczepański, S. (2020) · Sensors · doi:10.3390/s20113303 · Cited by 22
A low complexity lossless compression scheme for wearable ECG sensors
Deepu, C. J., & Lian, Y. (2015) · IEEE International Conference on Digital Signal Processing (DSP) · doi:10.1109/icdsp.2015.7251912 · Cited by 22
Self-citationAdvances in Neural Recording and Stimulation Integrated Circuits
Li, J., Liu, X., Mao, W., Chen, T., & Yu, H. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.663204 · Cited by 21
“, 2007) and then to add the digital quantization circuits (Zou et al., 2009; Liu et al., 2017; Yu et al., 2018).”
BackgroundSharma, K., & Sharma, R. (2017) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2017.8227913 · Cited by 21
“Tunable amplifier for bio-potential signal recording applications using voltage controlled depletion-mode PMOS pseudo-resistor [20] and low noise tunable front-end amplifier with fully balanced tunable pseudo-resistor [9] are two good examples of the same.”
BackgroundMethodInfluentialA novel programmable attenuator based low Gm-OTA for biomedical applications
Rajan, V., Kishore, K. H., Sanjay, R., Kumaravel, S., & Venkataramani, B. (2020) · Microelectronics Journal · doi:10.1016/j.mejo.2020.104721 · Cited by 21
Kledrowetz, V., Fujčík, L., Prokop, R., & Háze, J. (2020) · Sensors · doi:10.3390/s20154137 · Cited by 21
Rothe, R., Cho, M., Choo, K. D., Jeong, S., Oh, S., Lee, J., Sylvester, D., & Blaauw, D. T. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3135899 · Cited by 20
A 0.7-V 17.4-µW 3-lead wireless ECG SoC
Khayatzadeh, M., Zhang, X., Tan, J. H., Liew, W.-S., & Lian, Y. (2012) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2012.6418426 · Cited by 20
“A capacitive coupled 2-channel analog front-end [1] is implemented in this SoC.”
BackgroundMethodSelf-citationDesign of an ultra-low power SAR ADC for biomedical applications
Zhang, H., Qin, Y., Yang, S., & Hong, Z. (2010) · IEEE International Conference on Solid-State and Integrated Circuit Technology · doi:10.1109/icsict.2010.5667670 · Cited by 20
“Comparison with the state-of-the art designs Specifications Thiswork JSSC’07 [6] JSSC’09 [2] Technology 0.18 m 0.18 m 0.35 m Supply Voltage (V) 1.8 1 1V Sampling Rate (S/s) 2K 100K 1K Resolution (Bit) 12 12 12 ENOB (Bit) 10 10.5 10.2 SFDR (dB) 78.7 71 74 Power 455nW 25 W 233nW FOM (fJ/Conv-Step) 220 165 200”
BackgroundInfluentialA wireless ecg plaster for real-time cardiac health monitoring in body sensor networks
Zhang, D. R., Deepu, C. J., Xu, X. Y., & Lian, Y. (2011) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2011.6107763 · Cited by 19
“In our proposed ECG plaster, we use a proprietary biomedical data acquisition frontend chip that employs and extends the solutions we demonstrated in [4][5].”
MethodSelf-citationYuan, C., & Lam, Y. Y. H. (2013) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2013.6571919 · Cited by 19
“INTRODUCTION SAR ADCs have been extensively used in biomedical applications, such as EEG, ECG and bioimplantable systems [1] [2] [3].”
BackgroundDouble-Differential Recording and AGC Using Microcontrolled Variable Gain ASIC
Rieger, R., & Deng, S.-L. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2213842 · Cited by 19
A Fully Digital Front-End Architecture for ECG Acquisition System With 0.5 V Supply
Zare, M., & Maymandi‐Nejad, M. (2015) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2015.2395540 · Cited by 18
“Biomedical signal acquisition systems [1]–[5] typically consist of a low-noise amplifier (LNA), a bandpass filter, an analog sample-and-hold, and an analog-to-digital converter (ADC), as shown in Fig.”
BackgroundMethodKárász, Z., Fiáth, R., Földesy, P., & Vázquez, Á. R. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2294971 · Cited by 18
An event-based ECG-monitoring and QRS-detection system based on level-crossing sampling
Ravanshad, N., & Rezaee-Dehsorkh, H. (2017) · Iranian Conference on Electrical Engineering · doi:10.1109/iraniancee.2017.7985460 · Cited by 18
A High-Linearity Low-Noise Amplifier with Variable Bandwidth for Neural Recoding Systems
Yoshida, T., Sueishi, K., Iwata, A., Matsushita, K., Hirata, M., & Suzuki, T. J. (2011) · Japanese Journal of Applied Physics · doi:10.1143/jjap.50.04de07 · Cited by 18
High-density neural recording system design
Lee, H.-S., Eom, K., Park, M., Ku, S.-B., Lee, K., & Lee, H.-M. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00233-z · Cited by 17
Impact of parasitics on even symmetric split‐capacitor arrays
Rodríguez‐Pérez, A., Delgado‐Restituto, M., & Medeiro, F. (2012) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.1806 · Cited by 17
A sub-1µW, 16kHz current-mode SAR-ADC for single-neuron spike recording
Haaheim, B., & Constandinou, T. G. (2012) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2012.6271937 · Cited by 17
“Parameter [5] [7] [6] [12] This work VDD 1V 0.”
BackgroundAbidin, Z., Tanno, K., Mago, S., & Tamura, H. (2017) · International Journal of Electrical and Computer Engineering (IJECE) · doi:10.11591/ijece.v7i2.pp759-766 · Cited by 17
A fabrication of a low-power low-noise neural recording amplifier based on flipped voltage follower
Farouk, T., Dessouky, M. A., & Elkhatib, M. (2020) · Microelectronics Journal · doi:10.1016/j.mejo.2020.104817 · Cited by 17
Ultralow-Power Synchronous Demodulation for Low-Level Sensor Signal Detection
Maya-Hernandez, P. M., Calvo, B., & Sanz, M. T. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2881821 · Cited by 17
“We focused on active structures commonly used in the area of biomedical instrumentation under the name of pseudoresistors, which lead to very high resistive values [32]–[37].”
BackgroundMii, K., Kanemoto, D., & Hirose, T. (2024) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ad264f · Cited by 16
“30) Figure 5 shows the input EEG signal and output differential voltage waveform of the CCIA during chopping.”
BackgroundIntegrated ExG, Vibration and Temperature Measurement Front-End for Wearable Sensing
Rieger, R., & Rif’an, M. (2018) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2017.2785863 · Cited by 16
“Examples for sensing circuits developed in this design space are front-end amplifiers with variable gain reported in [5]–[7] and multisignal systems as in [8]–[12].”
BackgroundAn 8-bit single-ended ultra-low-power SAR ADC with a novel DAC switching method
Hu, W., Lie, D. Y. C., & Liu, Y. (2012) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2012.6271767 · Cited by 16
Juan, Y.-H., Huang, H., Lai, S.-C., Juang, W.-H., Lee, S.-Y., & Luo, C. (2015) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2015.2468918 · Cited by 16
“In addition, the required ADC resolution is 8–12 b in electrocardiogram and electroencephalography applications [1]–[3].”
BackgroundCMOS analog front end for ECG measurement system
Lyu, Y.-J., Wu, Q.-X., Huang, P.-S., & Chen, H. (2012) · International Symposium on Intelligent Signal Processing and Communication Systems (ISPACS) · doi:10.1109/ispacs.2012.6473505 · Cited by 15
“In the system, a low-noise, low-power, high-gain amplifier is required [1]-[3].”
Background0.3‐V bulk‐driven programmable gain amplifier in 0.18‐µm CMOS
Kulej, T., & Khateb, F. (2016) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.2269 · Cited by 15
“According to our survey, the VGA/PGA circuits presented so far in open literature were supplied with relatively large voltages, ranging from 1V for ULP biomedical circuits [7], to several volts for high-frequency VGAs devoted to communication receivers [8–22].”
BackgroundMethodInfluentialEnergy-Efficient Amplifiers Based on Quasi-Floating Gate Techniques
López‐Martín, A. J., Garde, M. P., Algueta, J. M., Beloso‐Legarra, J., Carvajal, R. G., & Ramirez‐Angulo, J. (2021) · Applied Sciences · doi:10.3390/app11073271 · Cited by 15
“An efficient approach to achieve the large time constant required is replacing resistor RB in Figure 1b by a pseudo-resistor (also known as quasi-infinite resistor, QIR) [6,7].”
MethodUm, J., Kim, J.-H., Sim, J., & Park, H.-J. (2011) · IEEE Asian Solid-State Circuits Conference (A-SSCC) · doi:10.1109/asscc.2011.6123608 · Cited by 15
Low-Power Integrated Circuit Design for Wearable Biopotential Sensing
Ha, S., Kim, C., Yu, M., & Cauwenberghs, G. (2014) · Elsevier eBooks · doi:10.1016/b978-0-12-418662-0.00018-0 · Cited by 15
Sharma, K., Jamuar, S. S., & Sharma, R. (2020) · Review of Scientific Instruments · doi:10.1063/1.5125409 · Cited by 15
Low-power integrated circuits for wearable electrophysiology
Ha, S., Kim, C., Wang, H., Yu, M., Mercier, P. P., & Cauwenberghs, G. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819246-7.00006-1 · Cited by 16
A Bootstrapped Pseudo Resistor by Reusing OTA-C Filter for Neural Signal Processing
Zhou, Z., Liao, H., Zhu, L., Liu, Y., Zhu, L., Wang, K., & Wang, Z. (2021) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2021.3102249 · Cited by 15
Tateno, T., & Nishikawa, J. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00039 · Cited by 15
Power Efficient ADCs for Biomedical Signal Acquisition
Rodríguez‐Pérez, A., Delgado‐Restituto, M., & Medeiro, F. (2011) · InTech eBooks · doi:10.5772/13070 · Cited by 15
“For the design of the ADCs, many authors choose the SAR architecture with capacitivebased DACs due to their suitability for low-power and low-voltage needed requirements (Agnes et al., 2008; Hong and Lee, 2007; Saurbrey et al., 2003; Scott et al., 2003; Verma and Chandrakasan, 2007; Zou et al., 2009).”
BackgroundMethodInfluentialThakur, D., Sharma, K., & Sharma, R. (2022) · ECS Transactions · doi:10.1149/10701.10969ecst · Cited by 14
A 0.5 μA/Channel front-end for implantable and external ambulatory ECG recorders
Rezaeiyan, Y., Zamani, M., Shoaei, O., & Serdijn, W. A. (2018) · Microelectronics Journal · doi:10.1016/j.mejo.2018.01.016 · Cited by 14
“TABLE II BIO-POTENTIAL PERFORMANCE SUMMARY AND COMPARISON WITH THE STATE OF THE ART This Work [12] [9] [3] [5] [7] [16] [18]”
MethodA Voltage Swing Robust Pseudo-Resistor Structure for Biomedical Front-end Amplifier
Zhang, S., Zhou, X., & Li, Q. (2018) · IEEE Asia Pacific Conference on Circuits and Systems (APCCAS) · doi:10.1109/apccas.2018.8605717 · Cited by 14
“Voltage-controlled pseudoresistor offers tunable and voltage swing robust resistance at the cost of additional biasing circuit which increases the complexity [4] [5].”
BackgroundSelf-Dithering Technique for High-Resolution SAR ADC Design
He, L., Jin, L., Yang, J., Lin, F., Yao, L., & Jiang, X. (2015) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2015.2468921 · Cited by 14
“For this reason, successive-approximation-register ADCs (SAR ADCs) were widely used in fully integrated biosensing systems [1]–[3].”
MethodSelf-citationLow Noise Amplifier in Smart Healthcare Applications
Bansal, M., & Jyoti (2019) · International Conference on Signal Processing and Integrated Networks (SPIN) · doi:10.1109/spin.2019.8711705 · Cited by 14
“The low noise front-end amplifier employs capacitance feedback circuitry with a fully differential operational transconductance amplifier to obtain low signal distortion and high dynamic range using balanced tunable pseudoresistors which is implement in feedback loop [37].”
MethodUsing biopotential and bio-impedance for intuitive human–robot interaction
Park, K., Jeong, H., Jung, Y., Suh, J.-H., Je, M., & Kim, J. (2025) · Nature Reviews Electrical Engineering · doi:10.1038/s44287-025-00191-5 · Cited by 13
Review on Variable and Programmable Gain Amplifiers and Applications
de Deus, M. S., Catunda, S. Y. C., Soares, A. W. A., & Belfort, D. R. (2022) · Journal of Integrated Circuits and Systems · doi:10.29292/jics.v17i1.583 · Cited by 12
“ECG systems can use fixed gain amplifiers [113], but the use of VGA/PGA [50, 100, 102] usually improves readings, since it optimizes the ADC performance.”
MethodInfluentialAdaptive successive approximation ADC for biomedical acquisition system
Chang, H.-W., Huang, H., Juan, Y.-H., Wang, W.-S., & Luo, C. (2013) · Microelectronics Journal · doi:10.1016/j.mejo.2013.06.015 · Cited by 12
A Low-Power CMOS Analog Front-End IC with Adjustable On-Chip Filters for Biosensors
Lie, D. Y. C., Das, V. R., Hu, W., Liu, Y., & Nguyen, T. (2013) · Open Journal of Applied Biosensor · doi:10.4236/ojab.2013.24014 · Cited by 12
“pass filter (HPF) is usually placed before an INA to remove the DC voltages, especially due to the concerns of large DC offsets across differential electrodes that can be caused by the electrochemical effects at the electrodetissue interface that can saturate the subsequent AFE circuitry [2-5].”
BackgroundMethodInfluentialA novel pseudo resistor structure for biomedical front-end amplifiers
Huang, Y., Yang, T., Hsu, S., Chen, X., & Chiou, J. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318952 · Cited by 12
Abidin, Z., Tanno, K., Mago, S., & Tamura, H. (2016) · IEEE International Symposium on Multiple-Valued Logic (ISMVL) · doi:10.1109/ismvl.2016.46 · Cited by 12
“So that Common-Mode Rejection Ratio (CMRR) is one of the key parameters to measure the performance of an IA [2].”
BackgroundA 0.6V, 8.4uW AFE circuit for biomedical signal recording
Chen, C., Chen, L., Wang, X., & Zhang, F. (2018) · Microelectronics Journal · doi:10.1016/j.mejo.2018.03.009 · Cited by 12
Hao, Y., Chen, M., Chen, W., Zhao, Y., & Li, Y. (2021) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2021.3065973 · Cited by 12
“In [10], a bootstrapped-PR is adopted to realize tunable fHP and improve the linearity.”
MethodUltra-Low-Power Analog-to-Digital Converters for Medical Applications
Zhang, D. (2014) · Linköping studies in science and technology. Dissertations · doi:10.3384/diss.diva-110387 · Cited by 12
“61 4.6 Measured ADC Performance Under Different Supply Voltages . . . 61 4.7 ADC Comparison . . . . . . . . . . . . . . . . . . . . . . . . . .”
InfluentialAnti-artifacts techniques for neural recording front-ends in closed-loop brain-machine interface ICs
Chen, W., Liu, X., Wan, P., Chen, Z., & Chen, Y. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1393206 · Cited by 11
Ali, İ., Rikhan, B., Kim, D.-G., Lee, D., Rehman, M., Abbasizadeh, H., Asif, M., Lee, M., Hwang, K. C., Yang, Y., et al. (2018) · Sensors · doi:10.3390/s18051555 · Cited by 11
“Reference [12] focuses on a sensor interface IC for biomedical applications, in which the ADC outputs the sensor data.”
BackgroundAntayhua, R. A. R., Silva, G. M. D., & de Sousa, F. R. (2012) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2012.6229394 · Cited by 11
A low-power 84-dB dynamic-range tunable Gm-C filter for bio-signal acquisition
Lu, J., Tan, Y., Jahan, M. S., & Holleman, J. H. (2014) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2014.6908593 · Cited by 11
“Keywords— Gm-C filter, transconductor, bio-signal acquisition I. INTRODUCTION Bio-potential signals provide vital information about the patient for disease diagnosis and health monitoring.”
BackgroundA low-noise low-power amplifier for implantable device for neural signal acquisition
Li, M., & Tang, K. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5335204 · Cited by 11
Wu, C.-C., Chuang, W.-Y., Wu, C.-D., Su, Y.-C., Huang, Y.-Y., Huang, Y.-J., Peng, S.-Y., Yu, S.-A., Lin, C., & Lu, S. (2017) · Sensors · doi:10.3390/s17040715 · Cited by 11
An 8-channel readout front-end for long-term sleep quality monitoring
Pu, X., Zhang, H., Qin, Y., & Hong, Z. (2011) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2011.6107808 · Cited by 11
“TABLE I. COMPARISON OF THE PROPOSED AC COUPLED IA TO SEVERAL PRIOR WORKS Parameter This Work [3]* [4]* [5]* Supply Voltage (V) 2.7 3 1.8 3 Supply Current (µ A) 9.9 11.1 1.2 2.3 Input Impedance (MΩ) >1000 >100 >7.5 >1000 Electrode Offset (mV) 54 50 50 45 Noise (µ Vrms) 0.49 0.6 0.94 0.59 CMRR (dB) 118 >120 105 >120 NEF…”
BackgroundInfluentialA linear tunable amplifier for implantable neural recording applications
Rezaee-Dehsorkh, H., Ravanshad, N., Lotfi, R., & Mafinezhad, K. (2011) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2011.6026523 · Cited by 11
“Although several attempts have been reported to decrease the power consumption and increase the signal-to-noise-ratio (SNR) of biomedical sensor interface systems [1]-[4], only a few works have discussed the linearity of these systems [2] [5].”
BackgroundInfluentialAn Osmotic Pressure Sensor for Monitoring the Level of Hydration in Biological Fluids
Fernandes, L. A. L., Azadmehr, M., Johannessen, E. A., & Hafliger, P. D. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2548361 · Cited by 11
“Ultra low-power integrated circuit architectures push the power consumption down to the lowest reported figures known today in combination with a small circuit footprint [21].”
BackgroundA low-power reconfigurable ADC for biomedical sensor interfaces
Rodríguez‐Pérez, A., Delgado‐Restituto, M., Medeiro, F., & Rodriguez-Vazquez, A. (2009) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2009.5372037 · Cited by 11
“In order to include programmability on this block, the multiplicity of transistors M1, M6 and M7 is selectable, controlling the bias current of the opamp and adapting it to the required bandwidth [3].”
BackgroundMethodInfluentialLi, F., Yang, H., Liu, F., Yin, T., & Wang, X. (2012) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-012-9844-5 · Cited by 10
“However, as reported in [16], changing the capacitive load gives no DC current saving with narrow bandwidth applications.”
BackgroundLow-Cutoff Frequency Reduction in Neural Amplifiers: Analysis and Implementation in CMOS 65 nm
Noshahr, F. H., Nabavi, M., Gosselin, B. J., & Sawan, M. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.667846 · Cited by 10
“This can be resolved by designing the neural amplifier in 2 or 3 gain stages (Zou et al., 2009; Rezaee-Dehsorkh et al., 2011).”
BackgroundZheng, G., Mohanty, S. P., & Kougianos, E. (2012) · International Conference on Computing, Communication and Networking Technologies (ICCCNT) · doi:10.1109/icccnt.2012.6396103 · Cited by 10
“The CT DSM should have at least 10-bit resolution and be able to handle input signals up to 10 kHz to meet the biomedical application requirements [8], [9].”
BackgroundA self-calibration circuit for a neural spike recording channel
Rodríguez‐Pérez, A., Ruiz‐Amaya, J., Delgado‐Restituto, M., Sawan, M., & Rodriguez-Vazquez, A. (2011) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2011.6107828 · Cited by 10
A 66-dB SNDR, 8-μW analog front-end for ECG/EEG recording application
Chen, C., Chen, L., Wang, X., & Zhang, F. (2018) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2018.8351783 · Cited by 10
A Wearable EEG Amplifier Using a Novel Teraohm Low-Distortion Tunable Hybrid Pseudo-Resistor
Abbasi, M. U. (2021) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas51556.2021.9401111 · Cited by 10
A fully-differential input amplifier with band-pass filter for biosensors
Meng, X., Li, W., & Temes, G. C. (2014) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2014.6865055 · Cited by 10
“In [6], a tunable “pseudo-resistor” was described using a set of almost turned-off MOSFETs, which can realize a wide range of resistances, but with poorly controlled value.”
BackgroundUm, J., Sim, J., & Park, H.-J. (2010) · JSTS Journal of Semiconductor Technology and Science · doi:10.5573/jsts.2010.10.4.309 · Cited by 10
“7 V compared to the published ECG amplifiers [4, 6-8].”
BackgroundMethodLow-Power Delta-Sigma Modulators for Medical Applications
Yeknami, A. F. (2014) · Linköping University Electronic Press eBooks · doi:10.3384/diss.diva-102903 · Cited by 10
Wearable Sensors for Vital Signs: A Review of 20 Years and Future Directions
Suo, Y., Guo, H., Yu, R., & Zhao, Y. (2024) · Integrated Circuits and Systems · doi:10.23919/ics.2024.3511474 · Cited by 9
Low Common-Mode Gain Instrumentation Amplifier Architecture Insensitive to Resistor Mismatches
Abidin, Z., Tanno, K., Mago, S., & Tamura, H. (2016) · International Journal of Electrical and Computer Engineering (IJECE) · doi:10.11591/ijece.v6i6.pp3247-3254 · Cited by 9
“The signals amplitude and frequency spans are in the order of μV to mV and from DC to a few kHz, respectively [1]-[4].”
BackgroundDynamic-Range-Enhancement Techniques for Artifact-Tolerant Biopotential-Acquisition ICs
Jung, Y., Kweon, S.-J., Lee, T., Jeong, K., Ha, S., & Je, M. (2022) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2022.3176272 · Cited by 9
A Low-power Low-noise Reconfigurable Bandwidth BiCMOS Neural Amplifier
Tasneem, N. T., & Mahbub, I. (2018) · IEEE Dallas Circuits and Systems Conference (DCAS) · doi:10.1109/dcas.2018.8620113 · Cited by 9
“By using the triple-well nMOS transistors the overall input-referred noise can be reduced as the body of the nMOS is isolated from the p-substrate by creating a deep n-well [19].”
MethodA Low-Noise Area-Efficient Current Feedback Instrumentation Amplifier
Sanjay, R., Venkataramani, B., Kumaravel, S., Rajan, V., & Kishore, K. H. (2020) · Circuits Systems and Signal Processing · doi:10.1007/s00034-020-01527-2 · Cited by 9
Kim, H., Park, Y.-H., Eom, K., & Park, S. (2021) · Electronics · doi:10.3390/electronics10161972 · Cited by 9
Internet of Things: Towards a Solid Ecosystem of Interconnected Things
Chakroun, M., Sayah, J., Kallab, C., & Haddad, S. (2022) · Advances in Internet of Things · doi:10.4236/ait.2022.123004 · Cited by 9
“Wi-Fi Direct is a peer-to-peer communication protocol that links devices without the necessity of an intermediary access point.”
BackgroundMethodInfluentialAn ultra-low power interface CMOS IC design for biosensor applications
Hu, W., Liu, Y., Das, V. R., Schecht, C., Nguyen, T., Lie, D. Y. C., Yan, T.-C., Kuo, C., Wu, S., Chu, Y., et al. (2012) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2012.6292240 · Cited by 9
“Both SAR ADCs and sigma-delta ADCs have been used as low-speed low-power ADCs in AFE ICs for bio-medical applications [1] [6] [7].”
MethodModeling of EXG (ECG, EMG and EEG) non-idealities using MATLAB
Adimulam, M. K., & Srinivas, M. B. (2016) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp-bmei.2016.7852968 · Cited by 8
Metadata
- Authors
- Zou, X., Xu, X., Yao, L., & Lian, Y.
- Affiliations
- National University of Singapore (SG)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2009-04
- Volume
- 44
- Issue
- 4
- Pages
- 1067-1077
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2152776190
- Cited by
- 414
- References
- 10
- Citations by year
- 2026: 6 · 2025: 16 · 2024: 16 · 2023: 9 · 2022: 12 · 2021: 22 · 2020: 25 · 2019: 29 · 2018: 27 · 2017: 31 · 2016: 35 · 2015: 35 · 2014: 40 · 2013: 31 · 2012: 29
- FWCI
- 16.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- National University of Singapore (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- low-power analog front-end, low-voltage operation, low noise amplifier, tunable bandpass filter, successive approximation register ADC, relaxation oscillator, heartbeat detection, ECG recording, noise efficiency factor, CMOS integrated circuit
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.