A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
This paper presents a fully integrated programmable biomedical sensor interface chip dedicated to the processing of various types of biomedical signals. The chip, optimized for high power efficiency, contains a low noise amplifier, a tunable bandpass filter, a programmable gain stage, and a successive approximation register analog-to-digital converter. A novel balanced tunable pseudo-resistor is proposed to achieve low signal distortion and high dynamic range under low voltage operations. A 53 nW, 30 kHz relaxation oscillator is included on-chip for low power consumption and full integration. The design was fabricated in a 0.35 mum standard CMOS process and tested at 1 V supply. The analog front-end has measured frequency response from 4.5 mHz to 292 Hz, programmable gains from 45.6 dB to 60 dB, input referred noise of 2.5 muVrmsin the amplifier bandwidth, a noise efficiency factor (NEF) of 3.26, and a low distortion of less than 0.6% with full voltage swing at the ADC input. The system consumes 445 nA in the 31 Hz narrowband mode for heart rate detection and 895 nA in the 292 Hz wideband mode for ECG recording.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The most common way is to add a low noise amplifier (LNA) to the front end of the recording (Harrison and Charles, 2003; Harrison et al., 2007) and then to add the digital quantization circuits (Zou et al., 2009; Liu et al., 2017; Yu et al., 2018).”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Zou et al., 2009
Citations
Cites
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451 · cited 1×
“power, and area as demonstrated in [4], [5].”
BackgroundAn Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441
A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.894804 · Cited by 382 · cited 3×
“2 [2]–[6].”
BackgroundOlssonIII, R. H., Buhl, D. L., Sirota, A. M., Buzsaki, G., & Wise, K. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847540 · Cited by 181 · cited 1×
“However, the existing tunable pseudo-resistor [7]–[9], as shown in Fig.”
MethodA 128-Channel 6mW Wireless Neural Recording IC with On-the-Fly Spike Sorting and UWB Tansmitter
Chae, M., Liu, W., Yang, Z., Chen, T., Kim, J., Sivaprakasam, M., & Yuce, M. (2008) · 2008 IEEE International Solid-State Circuits Conference - Digest of Technical Papers · doi:10.1109/isscc.2008.4523099 · Cited by 159
A Low-Noise Preamplifier with Adjustable Gain and Bandwidth for Biopotential Recording Applications
Yin, M., & Ghovanloo, M. (2007) · 2007 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2007.378400 · Cited by 129 · cited 1×
“In the single amplifier approach, the bandwidth and gain tuning features are implemented within one closed-loop amplifier [6].”
BackgroundA 1-V 450-nW fully integrated biomedical sensor interface system
Xu, X., Zou, X., Yao, L., & Lian, Y. (2008) · Symposium on VLSI Circuits · doi:10.1109/vlsic.2008.4585959 · Cited by 41 · cited 1×
“interface IC (first presented in [10]).”
Self-citationA low-voltage low-power QFG-based Sigma-Delta modulator for electroencephalogram applications
López-Morillo, E., Carvajal, R. G., Galán, J., Ramirez‐Angulo, J., López‐Martín, A. J., & Rodriguez–Villegas, E. (2006) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2006.4600322 · Cited by 9 · cited 1×
“The OTA incorporates a push-pull output scheme by adopting ( , and ) and ( , and ) [12], where the slew rate is not limited by the quiescent current of the OTA and the driving capability of the OTA is greatly enhanced.”
Background
Research works printed but not linked: 3
- zou, 2008, a 1-v 1.1-<ref_formula><tex notation="tex">$\mu\hbox{w}$</tex> </ref_formula> sensor interface ic for wearable biomedical devices, Proc IEEE Int Symp Circuits and Systems (ISCAS 2008), 2725
- wu, 2006, a 1 v 2.3 <ref_formula><tex notation="tex">$\mu\hbox{w}$</tex> </ref_formula> biomedical signal acquisition ic, IEEE ISSCC Dig Tech Papers, 58
- 1998, Medical Instrumentation Application and Design, 259
Cited by
Items 401–457 of 457
Brain–Machine Interface: System Optimization
Zjajo, A. (2016) · Springer eBooks · doi:10.1007/978-3-319-31541-6_5
Design of a variable rate low power SAR ADC with bypass window for biomedical application
Liu, Y. (2014) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/62157
“Biomedical signals normally have different characteristics [2]-[4], with the amplitude ranging from the order of tens of μV to tens of mV and the frequencies spanning from DC to a few kHz [5], [6].”
BackgroundMonteiro, M. F. C. (2015) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Optimizing simulation times in biomedical systems containing Quasi-Infinite Resistors
Iranmanesh, S., Eid, M. H., & Rodriguez–Villegas, E. (2016) · IEEE Nordic Circuits and Systems Conference (NorCAS) · doi:10.1109/norchip.2016.7792912
“Furthermore, Quasi-Infinite Resistor (QIR) elements have recently been widely used in creating circuits to reject DC offsets in biomedical systems [3].”
BackgroundBrain Activity Measurement with Implantable Microchip
Kárász, Z. (2016) · REAL-PhD (Hungarian Academy of Sciences)
Low power SAR ADC designs for sensing applications
Yang, Y. (2017) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/70201
“To achieve the features of wireless sensor nodes such as long life and small volume, energyand area- efficient electronic circuits have been popularly engaged, including sensor interface circuits [14, 44, 51, 53, 69], digital signal processing [6, 7, 21] and wireless communication subsystem [96-98].”
BackgroundMethodKim, B. (2014) · University of Minnesota Digital Conservancy (University of Minnesota)
Diseño de Circuitos Integrados para interfaz neural
Oreggioni, J. (2013) · Americanae (AECID Library)
A 76μW, 58-dB SNDR analog front-end chip for implantable intraocular pressure detection
Chen, C., Chen, L., Wang, X., & Zhang, F. (2017) · IEEE International Conference on ASIC (ASICON) · doi:10.1109/asicon.2017.8252439
Ultra-Low-Power Techniques in Small Autonomous Implants and Sensor Nodes
Gosselin, B. J., Roy, S., & Hosseini, F. S. (2017) · CRC Press eBooks · doi:10.1201/b15283-23
An Active Electrode Readout Circuit
Xu, J., Yazıcıoğlu, R. F., Hoof, C. A. V., & Makinwa, K. A. A. (2018) · Analog circuits and signal processing/Analog circuits and signal processing series · doi:10.1007/978-3-319-74863-4_3
Designing of Digital Front-End Structure for ECG Acquisition System
Subhan, K. M. (2018) · International Journal for Research in Applied Science and Engineering Technology · doi:10.22214/ijraset.2018.3353
130nm CMOS SAR-ADC with Low Complexity Digital Control Logic
Borgarino, M., Verrascina, N., & Bégueret, J.-B. (2018) · IRIS UNIMORE (University of Modena and Reggio Emilia)
Low Voltage Digital ECG Acquisition System
Prakash, A. S., & Ravindran, A. (2019)
Introduction to ECoG interfaces
Ha, S., Kim, C., Mercier, P. P., & Cauwenberghs, G. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815115-0.00008-8
Integrated circuit interfaces for ECoG signal recording
Ha, S., Kim, C., Mercier, P. P., & Cauwenberghs, G. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815115-0.00009-x
Fully integrated modular ECoG recording and stimulation
Ha, S., Kim, C., Mercier, P. P., & Cauwenberghs, G. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815115-0.00015-5
Clock-less 8-bit SAR-ADC with delay-line based digital control circuit
Borgarino, M., Giacomini, L., Luppi, G., Digiaro, F., Bégueret, J.-B., & Verrascina, N. (2019) · Microelectronics Journal · doi:10.1016/j.mejo.2019.104641
Shimamura, T., & Morimura, H. (2021) · IEICE Transactions on Electronics · doi:10.1587/transele.2020cdp0001
Demin, G. D., Andrushin, R., & Djuzhev, N. A. (2020) · IEEE All-Russian Microwave Conference (RMC) · doi:10.1109/rmc50626.2020.9312370
“4 Biomedical sensor 450 [14] 5 Actuator 1000 [15]”
BackgroundPark, S. (2016) · Deep Blue (University of Michigan)
Energy efficient SAR ADC with resolution enhancement for sensor signals
Khurana, H. S. (2021) · DSpace@MIT (Massachusetts Institute of Technology)
Circuits and Techniques for Power-Efficiency Enhancement of IoT Sensor Nodes
Mondal, S. (2020) · eScholarship (California Digital Library)
A 59 pA/V and 62 nW Differential OTA with 0.35% THD for Biomedical Applications
Silva, R. S., Rodovalho, L. H., Marques, J. L. B., & Rodrigues, C. R. (2021) · Journal of Integrated Circuits and Systems · doi:10.29292/jics.v16i2.490
Circuit and architecture solutions for the low-voltage, low-power domain
Albano, D., Pantano, P., & Crupi, F. (2016) · Archive of Doctoral Theses and Digital Collections (University of Calabria)
Low Area Digital Front-End for Single Lead ECG Acquisition
Neelamsetty, S. K., & Balivada, L. K. (2021) · International Conference on Electrical, Electronics, Communication, Computer and Optimization Techniques (ICEECCOT) · doi:10.1109/iceeccot52851.2021.9708032
Murillo, C. A., Calvo, B., & Pueyo, S. C. (2012) · Springer eBooks · doi:10.1007/978-1-4614-6237-8_1
Ultralow Power Techniques in Small Autonomous Implants and Sensor Nodes
Gosselin, B. J., Roy, S., & Hosseini, F. S. (2017) · CRC Press eBooks · doi:10.1201/b13870-11
Energy Saving Techniques for Energy Constrained CMOS Circuits and SystemsPreprint
Sankar, S. (2022) · arXiv (Cornell University) · doi:10.48550/arxiv.2206.07639
Jeon, H., Park, J., Byeon, K., Jung, J., & Kim, H. (2023) · International Technical Conference on Circuits/Systems, Computers and Communications (ITC-CSCC) · doi:10.1109/itc-cscc58803.2023.10212698
“Reference [4] relies on a statistics-based method to calibrate the capacitor errors in the foreground.”
MethodXu, H., Liu, Y., Duan, Y., Li, T., Zhang, J., Li, Z., & Zhang, H. (2024) · Electronics · doi:10.3390/electronics13020366
Wide EDO handling range chopper amplifier based on high linearity PRs bulk-feedback DSL
Hu, S., Xu, W., Zhu, J., Wei, B., & Wei, X. (2024) · Workshop on Electronics Communication Engineering (WECE) · doi:10.1117/12.3015257
“Fortunately, a Pseudo-Resistor (PR) composed of sub-threshold MOSFETs can provide high value resistance in a small chip area [2-4] .”
BackgroundInfluentialGhafar‐Zadeh, E., Forouhi, S., & Azadmousavi, T. (2024) · Analog circuits and signal processing/Analog circuits and signal processing series · doi:10.1007/978-94-007-0099-4_4
Nonlinear Modeling and Precision Analysis of Neural Recording System in Simulink
He, J., Wang, Y., & Xu, J. (2024) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas61083.2024.10798142
“However, this improvement also brings challenges in chip area, power consumption, and system noise [5].”
Mii, K., Kanemoto, D., & Hirose, T. (2025) · Asia and South Pacific Design Automation Conference (ASP-DAC) · doi:10.1145/3658617.3698493
“However, because the EEG signal is distributed mainly in the frequency band below 100 Hz [7], reducing flicker noise is important for improving the signal-to-noise ratio.”
A 6 bits 10 MS/s SAR ADC with multi-conversion dynamic amplifier
Lee, J.-K., & Oh, D. (2025) · IEICE Electronics Express · doi:10.1587/elex.22.20250204
Liu, Q., Shu, Z., Alphones, A., & Gao, Y. (2025) · Electronics · doi:10.3390/electronics14142766
Lin, X., Wang, B., Liu, L., Zhou, X., Yang, W., & Wang, H. (2025) · Circuits Systems and Signal Processing · doi:10.1007/s00034-025-03268-6
“Typical low-power acquisition systems [ 3 , 13 , 32 ] employ ADCs with resolutions of 8–12 bits, and considering the trade-off between resolution and clock rate, the SS ADC in this paper is chosen to have a 9-bit resolution.”
Jha, P. K., Patra, P., Gundlapalle, V., Dutta, A., Acharyya, A., & Vadnala, S. (2025) · Circuits Systems and Signal Processing · doi:10.1007/s00034-025-03324-1
He, J., Xu, J., & Wang, Y. (2025) · Micromachines · doi:10.3390/mi16101176
“(2) To further enhance gain and linearity, the PGA adopts a programmable feedback architecture with adjustable capacitors, as shown in Figure 2b [39].”
Layout-accurate Ultra-fast System-level Design Exploration Through Verilog-ams
Zheng, G. (2013) · University of North Texas Digital Library (University of North Texas) · doi:10.12794/metadc271923
“The CT DSM should have at least 10-bit resolution and be able to handle input signals up to 10 kHz to meet the biomedical application requirements [100, 110].”
Low-Power Active Electrodes for Wearable EEG Acquisition
Xu, J. (2016) · Research Repository (Delft University of Technology) · doi:10.4233/uuid:0f80a5f1-d81f-4f1d-b6ae-01289f8dfef0
Σχεδίαση βιο-αισθητήρα χαμηλής ισχύος SoC και ασύρματα δίκτυα βιο-αισθητήρων
Zakakis, P. (2016) · DSpace - NTUA (National Technical University of Athens) · doi:10.26240/heal.ntua.12002
A Low-Power Receiver for Simultaneous Electrocardiogram and Respiratory Rate Detection
Liang, J. (2016) · OhioLink ETD Center (Ohio Library and Information Network)
Ultra-Low Energy Time-Mode ADC with Background Calibration for Biomedical Sensing Applications
Kandilakis, M. (. (2021) · Research Repository (Delft University of Technology)
Noshahr, F. H. (2020) · PolyPublie (École Polytechnique de Montréal)
MULTI-CHANNEL EEG SENSOR FRONTEND FOR PORTABLEHEALTH CONDITION MONITORING APPLICATIONS
Hoseini, S. Z. (2018) · OhioLink ETD Center (Ohio Library and Information Network)
Aragonés, R., & Electrònics, U. A. D. B. D. D. M. I. S. (2012) · Tesis Doctorals en Xarxa (Consorci de Serveis Universitaris de Catalunya)
Neves, F. S. F. D. O. (2021) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Zeznick, D., Ranganatham, R., O’Donnell, J., Adiga, C., Wright, W., & Das, T. (2026) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2026.3651181
“In biosensing applications, front-end circuits operate on microvolt-level physiological signals at sub-kilohertz frequencies [1].”
Zainul, A. (2017) · Institutional Repositories DataBase (IRDB)
Non-volatile Spintronic Flip-Flops with Checkpoint Preservation Supported in RISC-V Platform
Su, J., Chen, M., Qiu, Z., Liu, B., & Cai, H. (2026) · Design, Automation, and Test in Europe · doi:10.23919/date69613.2026.11539123
“To accommodate the dynamic nature of energy harvest [5], [6], intermittent computing systems employ incremental computation strategies, utilizing available energy to progressively advance the compute process and compensate for frequent power interruptions [7], [8].”
DESIGN AND ANALYSIS OF OTAWITH SAPON CIRCUIT USING CMOS TECHNOLOGY
Mundinamani, C. S., Kulkarni, D. M., & Payannavar, A. (2026) · International Journal of Novel Research and Development · doi:10.56975/ijnrd.v11i6.326066
Kim, D. H., Jang, S., Rhee, H., Lee, M. G., Kim, D., Go, T., Cheong, W. H., Song, H., & Kim, K. M. (2026) · Advanced Materials · doi:10.1002/adma.74529
“In addition, the power consumption of these peripheral circuits could be reduced to the sub-µ W-level, as suggested by prior low-power CMOS sensor-interface circuit designs [ 54–56 ].”
A 0.3-V Bulk-Driven Current-Mode Capacitance Multiplier for Area-Efficient BiomedicalFiltersPreprint
Sala, R. D., Nicolini, G., & Scotti, G. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7505863
MANCINI, F. (2026) · Electronic Theses and Dissertations Repository (University of Pisa)
Metadata
- Authors
- Zou, X., Xu, X., Yao, L., & Lian, Y.
- Affiliations
- National University of Singapore (SG)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2009-04
- Volume
- 44
- Issue
- 4
- Pages
- 1067-1077
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2152776190
- Cited by
- 414
- References
- 10
- Citations by year
- 2026: 6 · 2025: 16 · 2024: 16 · 2023: 9 · 2022: 12 · 2021: 22 · 2020: 25 · 2019: 29 · 2018: 27 · 2017: 31 · 2016: 35 · 2015: 35 · 2014: 40 · 2013: 31 · 2012: 29
- FWCI
- 16.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- National University of Singapore (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- low-power analog front-end, low-voltage operation, low noise amplifier, tunable bandpass filter, successive approximation register ADC, relaxation oscillator, heartbeat detection, ECG recording, noise efficiency factor, CMOS integrated circuit
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.