A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
This paper presents a fully integrated programmable biomedical sensor interface chip dedicated to the processing of various types of biomedical signals. The chip, optimized for high power efficiency, contains a low noise amplifier, a tunable bandpass filter, a programmable gain stage, and a successive approximation register analog-to-digital converter. A novel balanced tunable pseudo-resistor is proposed to achieve low signal distortion and high dynamic range under low voltage operations. A 53 nW, 30 kHz relaxation oscillator is included on-chip for low power consumption and full integration. The design was fabricated in a 0.35 mum standard CMOS process and tested at 1 V supply. The analog front-end has measured frequency response from 4.5 mHz to 292 Hz, programmable gains from 45.6 dB to 60 dB, input referred noise of 2.5 muVrmsin the amplifier bandwidth, a noise efficiency factor (NEF) of 3.26, and a low distortion of less than 0.6% with full voltage swing at the ADC input. The system consumes 445 nA in the 31 Hz narrowband mode for heart rate detection and 895 nA in the 292 Hz wideband mode for ECG recording.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The most common way is to add a low noise amplifier (LNA) to the front end of the recording (Harrison and Charles, 2003; Harrison et al., 2007) and then to add the digital quantization circuits (Zou et al., 2009; Liu et al., 2017; Yu et al., 2018).”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Zou et al., 2009
Citations
Cites
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451 · cited 1×
“power, and area as demonstrated in [4], [5].”
BackgroundAn Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441
A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.894804 · Cited by 382 · cited 3×
“2 [2]–[6].”
BackgroundOlssonIII, R. H., Buhl, D. L., Sirota, A. M., Buzsaki, G., & Wise, K. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847540 · Cited by 181 · cited 1×
“However, the existing tunable pseudo-resistor [7]–[9], as shown in Fig.”
MethodA 128-Channel 6mW Wireless Neural Recording IC with On-the-Fly Spike Sorting and UWB Tansmitter
Chae, M., Liu, W., Yang, Z., Chen, T., Kim, J., Sivaprakasam, M., & Yuce, M. (2008) · 2008 IEEE International Solid-State Circuits Conference - Digest of Technical Papers · doi:10.1109/isscc.2008.4523099 · Cited by 159
A Low-Noise Preamplifier with Adjustable Gain and Bandwidth for Biopotential Recording Applications
Yin, M., & Ghovanloo, M. (2007) · 2007 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2007.378400 · Cited by 129 · cited 1×
“In the single amplifier approach, the bandwidth and gain tuning features are implemented within one closed-loop amplifier [6].”
BackgroundA 1-V 450-nW fully integrated biomedical sensor interface system
Xu, X., Zou, X., Yao, L., & Lian, Y. (2008) · Symposium on VLSI Circuits · doi:10.1109/vlsic.2008.4585959 · Cited by 41 · cited 1×
“interface IC (first presented in [10]).”
Self-citationA low-voltage low-power QFG-based Sigma-Delta modulator for electroencephalogram applications
López-Morillo, E., Carvajal, R. G., Galán, J., Ramirez‐Angulo, J., López‐Martín, A. J., & Rodriguez–Villegas, E. (2006) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2006.4600322 · Cited by 9 · cited 1×
“The OTA incorporates a push-pull output scheme by adopting ( , and ) and ( , and ) [12], where the slew rate is not limited by the quiescent current of the OTA and the driving capability of the OTA is greatly enhanced.”
Background
Research works printed but not linked: 3
- zou, 2008, a 1-v 1.1-<ref_formula><tex notation="tex">$\mu\hbox{w}$</tex> </ref_formula> sensor interface ic for wearable biomedical devices, Proc IEEE Int Symp Circuits and Systems (ISCAS 2008), 2725
- wu, 2006, a 1 v 2.3 <ref_formula><tex notation="tex">$\mu\hbox{w}$</tex> </ref_formula> biomedical signal acquisition ic, IEEE ISSCC Dig Tech Papers, 58
- 1998, Medical Instrumentation Application and Design, 259
Cited by
Items 301–400 of 457
Lee, T., & Je, M. (2023) · arXiv (Cornell University) · doi:10.48550/arxiv.2305.13463 · Cited by 3
An All Analog Temporal Power-supply Trojan to Subvert ECG Biometric Authentication
Ranganatham, R., Ramos-Brito, R., Zuzak, M., & Das, T. (2025) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas56072.2025.11043350 · Cited by 2
Jeon, N., Kim, J., Bok, S., & Jang, Y. (2025) · Microelectronics Journal · doi:10.1016/j.mejo.2025.106869 · Cited by 2
Integrated Bioelectronics for Precision Health Monitoring
Xu, Y., Lee, M. S., Balaji, A., Uppal, A., Djassemi, O., Zhang, Y., Zhao, H., & Cauwenberghs, G. (2025) · Springer eBooks · doi:10.1007/978-981-95-2117-3_12 · Cited by 2
Low-Power, High-Dynamic Range Class-AB Tunable CMOS Filter for EEG, ECG, and EMG Signal Processing
Muñiz-Montero, C., Salas-Barradas, L. H., Díaz‐Sánchez, A., Tlelo‐Cuautle, E., Sánchez-López, C., Rodríguez, R. R., & Gaspariano, L. A. S. (2026) · Circuits Systems and Signal Processing · doi:10.1007/s00034-026-03653-9 · Cited by 2
Gosselin, B. J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091448 · Cited by 2
Li, F., Yin, T., & Wang, X. (2014) · Journal of Circuits Systems and Computers · doi:10.1142/s021812661450056x · Cited by 2
Zheng, H., Ding, Y., & Liu, X. (2024) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas58744.2024.10558392 · Cited by 2
“1(a) contains only a low-noise amplifier (LNA) stage[8].”
BackgroundA reconfigurable medically cohesive biomedical front-end with ΣΔ ADC in 0.18µm CMOS
Jha, P. K., Patra, P., Naik, J., Acharya, A., Rajalakshmi, P., Singh, S. G., & Dutta, A. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318491 · Cited by 2
“The high resistance value is obtained using a tunable pseudo-resistor [19] .”
BackgroundMethodA digitally self-calibration method with recursive DFT algorithm for 12-bit SAR ADC realization
Juan, Y.-H., Huang, H., Lee, S.-Y., Lai, S.-C., Juang, W.-H., & Luo, C. (2016) · International Conference on Applied System Innovation · doi:10.1109/icasi.2016.7539802 · Cited by 2
A 26.24uW 9.26-ENOB Dynamic RAM Based SAR ADC for Biomedical Applications
Ibrahim, O., Hesham, R., & Soltan, A. (2020) · doi:10.1109/icm50269.2020.9331493 · Cited by 2
“Successive Approximation Register (SAR) ADC is the commonly used for the signals that need processing is slow signals having a frequency range from DC to few kHz [1].”
BackgroundRaj, A., Singh, S., & Kumar, P. (2022) · International Journal of Electronics Letters · doi:10.1080/21681724.2022.2129808 · Cited by 2
“Filtering has become an indispensable elementary signal processing function in many applications like biomedical sensing, portable, wearable, and injectable devices (Yakovlev et al., 2012; Wise et al., 2008; Harrison, 2008; Zou et al., 2009; M. B. M. B. Elamien & Mahmoud, 2017).”
BackgroundA 32-bit Two-step Incremental-ADC with 125.6 dB Dynamic-range for Non-invasive BCI Applications
Gao, Z., Wang, S., & Chen, M. (2024) · IEEE Asia Pacific Conference on Circuits and Systems (APCCAS) · doi:10.1109/apccas62602.2024.10808500 · Cited by 2
Designing a reconfigurable biopotential amplifiers for medical instrumentation course
Kuo, Y.-C., Kuo, C.-Y., & Kuo, C. (2014) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2014.6974075 · Cited by 2
“By referring the ranges of amplitudes and frequencies of various biopotential sources indicated in [11], the available ranges of amplitudes and frequencies of the EOG, ECG and EMG are summarized in Table I.”
BackgroundA 0.4V 6.5nW 10b 2.5kS/s asynchronous SAR ADC
Jo, D., & Ryu, S. (2011) · IEEE MTT-S International Microwave Workshop Series on Intelligent Radio for Future Personal Terminals (IMWS-IRFPT) · doi:10.1109/imws2.2011.6027215 · Cited by 2
“Successive approximation ADC (SAR ADC) has been a popular choice for low speed design owing to its simple architecture and low power consumption [1, 2].”
BackgroundA hearing aid on-chip system based on accuracy optimized front- and back-end blocks
Li, F., & Jiang, H. (2014) · Journal of Semiconductors · doi:10.1088/1674-4926/35/3/035006 · Cited by 2
A 1.04µW wireless integrated MEMS interface in UMC 0.18µm CMOS
Laurenson, C., Rivet, F., Yuce, M. R., & Redouté, J. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318505 · Cited by 2
A 1.2 V 600 nW 12-bit 2 kS/s incremental ADC for biosensor application
Huang, T., Jin, L., Li, H., Diao, S., Wang, G., Yao, L., & He, L. (2014) · Journal of Semiconductors · doi:10.1088/1674-4926/35/11/115007 · Cited by 2
Self-citationA Self-Testing Platform with a Foreground Digital Calibration Technique for SAR ADCs
Juan, Y.-H., Huang, H.-Y., Lee, S.-Y., Lai, S.-C., Juang, W.-H., & Luo, C. (2016) · Applied Sciences · doi:10.3390/app6080217 · Cited by 2
“A calibration method is thus essential to ensure system quality [1,2].”
MethodAn 11‐μ W, 9‐bit fully differential, cyclic/algorithmic ADC in 0.13 μm CMOS
Bako, N., Fricke, K., Sobot, R., & Barić, A. (2016) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.2278 · Cited by 2
“The CMFB resistors are implemented by pMOS transistors MR, that is, pMOS transistors are actually pseudo-resistors [17].”
MethodAn 11-Bit Single-Ended SAR ADC with an Inverter-Based Comparator for Design Automation
Guan-Wei, J. E. N., & Lin, W.-L. (2016) · IEICE Transactions on Electronics · doi:10.1587/transele.e99.c.1331 · Cited by 2
Ito, K., Tani, T., Iwagami, T., Nishino, S., Kiyoyama, K., & Tanaka, T. (2017) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss.137.348 · Cited by 2
Sharma, K., Pathania, A., & Sharma, R. (2019) · Devices for Integrated Circuit (DevIC) · doi:10.1109/devic.2019.8783406 · Cited by 2
“Non-conventional techniques like Common Mode Linearization (CML) [10], SGL [6], FG [15], Quasi-Floating-Gate [16] have been found useful in overcoming the problem of nonlinearity in PRs.”
BackgroundMethodInfluentialIntegrated circuits design for neural recording sensor interface
Zou, X., Liu, L., Tan, Y. S., Je, M., & Seng, Y. K. (2012) · IEEE Asia Pacific Conference on Circuits and Systems (APCCAS) · doi:10.1109/apccas.2012.6418960 · Cited by 2
“Some of them modify the pseudo-resistor structure to get tunable resistance as shown in Figure (a) [17], so as to control the cut-off frequency of the amplifier.”
BackgroundMethodInfluentialSelf-citationCurrent mode sensor interface system for biomedical implantable applications
Maghsoudloo, E., Moradi, S., & Arian, A. (2012) · Iranian Conference on Electrical Engineering · doi:10.1109/iraniancee.2012.6292316 · Cited by 2
Ma, S., Chen, C., Zhang, Y., & Ren, J. (2012) · IEEE Asia Pacific Conference on Circuits and Systems (APCCAS) · doi:10.1109/apccas.2012.6419014 · Cited by 2
“Pseudo-resistor was proposed to solve this problem [2], but the asymmetry and nonlinearity of pseudoresistor degrade the dynamic range in low-voltage circuits [3].”
BackgroundInfluentialA variable bandwidth amplifier for a dual-mode low-power ΔΣ modulator in cardiac pacemaker system
Yeknami, A. F., & Alvandpour, A. (2013) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2013.6572242 · Cited by 2
A 0.5-V multi-channel low-noise readout front-end for portable EEG acquisition
Huang, W.-Y., Cheng, Y.-W., & Tang, K. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318492 · Cited by 2
A 0.36 μW/channel recorder for external ambulatory ECG recorders
Rezaeiyan, Y., & Shoaei, O. (2018) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-018-1124-6 · Cited by 2
A programmable analog baseband filter with DC offset reduction using servo loop feedback
Chang, C. (2018) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.2470 · Cited by 2
Ultra Low Power Digital Front-End for Single Lead ECG Acquisition
Thakkar, S., & Mishra, B. (2019) · International Conference on VLSI Design · doi:10.1109/vlsid.2019.00044 · Cited by 2
“Low input referred noise, reconfigurable bandwidth, and programmable gain are required in the front end processing block to accommodate the weak signals and the high dynamic range [1].”
BackgroundWagih, M., Komolafe, A. O., & Zaghari, B. (2019) · International Conference on Micro and Nanotechnology for Power Generation and Energy Conversion Applications (PowerMEMS) · doi:10.1109/powermems49317.2019.51289502905 · Cited by 2
“While such low power limits constrain this WPT technology to ultra-low power applications, multiple systems have been presented with sub-μW power consumption for implants and biomedical applications [5].”
BackgroundExperimental silicon tunnel-FET device model applied to design a Gm-C filter
Rangel, R. S., Agopian, P. G. D., & Martino, J. A. (2020) · Semiconductor Science and Technology · doi:10.1088/1361-6641/ab9ea8 · Cited by 2
Reduced Low-Voltage Electromyographic Signal Acquisition System Using Subthreshold Technique
Sanchez, J. R., Vazquez, A. M. L., & Padilla-Cantoya, I. R. (2020) · International Conference on Electrical Engineering, Computing Science and Automatic Control (CCE) · doi:10.1109/cce50788.2020.9299183 · Cited by 2
Low power high performance CMOS amplifier for epileptic seizure prediction
Renuga, M., & Gnanambal, K. (2021) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-021-01918-8 · Cited by 2
Nonvolatile Processor Architecture Exploration for Energy-Harvesting Application Scenarios
Ma, K., Li, S., Narayanan, V., & Xie, Y. (2019) · Springer eBooks · doi:10.1007/978-3-030-16949-7_8 · Cited by 2
Level-Crossing ADCs and Their Applications in Biomedical Readout Systems
Li, Y. (2015) · Research Repository (Delft University of Technology) · doi:10.4233/uuid:69f7fbd3-4922-4526-b92d-0f3a6bbe6ba8 · Cited by 2
“The LC sampling system is not yet comparable to standard approaches ([33, 36]) in terms of power.”
BackgroundTechniques and circuits for ultra-efficient energy harvesting sensor nodes
Savanth, P. A. (2021) · ePrints Soton (University of Southampton) · Cited by 2
A 33 µW Sub-3 dB Noise Figure Low Noise Amplifier for Medical Ultrasound Applications
Hansen, H. (2011) · BIBSYS Brage (BIBSYS (Norway)) · Cited by 2
CMOS Tunable Pseudo-Resistor with Low Harmonic Distortion
Solis, J. E. M., Padilla-Cantoya, I. R., Ocampo‐Hidalgo, J. J., Pérez, S. S., & Rivera-Mejia, J. (2023) · Electronics · doi:10.3390/electronics12163376 · Cited by 1
“…M3 and then, it must be extracted from the P-R itself, affecting the current of this device 3 of 12 Moreover, PMOS transistors allow dealing with the bulk-effect with the source-bulk terminals short-circuited on isolated devices. configuration, as depicted in Figure 3b, is commonly used [7,11,12].”
A mixed-mode on-chip automatic frequency tuning technique for biopotential amplifiers
Jha, P. K., Patra, P., Naik, K. R. J., Singh, A. K., & Dutta, A. (2024) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-024-02294-9 · Cited by 1
“Since 6-10 bit digitization of ECG signals have been reported in multiple front-ends [7, 12, 22, 34, 39], the degradation of the performance of the PGA emanating from the pseudo-resistor is unexpected.”
Wang, Y., Zhang, C., Zheng, C., Jin, H., Zhang, G., Zhao, Y., Zhang, J., Xu, J., & Zhang, H. (2024) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas61083.2024.10798398 · Cited by 1
Cai, Q., Xu, X., Suo, Y., Qian, G., Li, Y., Wang, G., Lian, Y., & Zhao, Y. (2025) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2025.3567524 · Cited by 1
“Conventional open-loop AFEs, designed with high gain followed by a medium-resolution ADC are energy-efficient but prone to saturation under sudden large artifacts [19], [20], [21], [22], [23].”
Self-citationHao, Y., Fan, H., Lian, Y., & Chen, M. (2025) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2025.3612895 · Cited by 1
“In order to improve the linearity, [16] introduced a fully balanced PR tuned via a 3-bit I-DAC, achieving 0.6% THD with a full-scale output 0018-9200 © 2025 IEEE.”
InfluentialSelf-citationMathews, R. P., Habibagahi, I., Sharemi, H. J., Alderete, J. A., Danesh, K., Cahill, C. M., & Babakhani, A. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11251531 · Cited by 1
SkinECG: An orthogonal remote powering wearable skin-like sensor
Tan, J. S. Y., Li, Z., Xiong, S., Lee, S., Fong, J. Y., Tang, T., Li, Z., Li, Z., Park, K., Kim, G., et al. (2026) · Science Advances · doi:10.1126/sciadv.aec9803 · Cited by 1
Sala, R. D., Privitera, M., Scotti, G., Grasso, A. D., & Alioto, M. (2026) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2026.3694840 · Cited by 1
“1(a),(b) and being m in the range of [1], [2], [3], [4], [5], [6], [7], and [8] Authorized licensed use limited to the terms of the applicable license agreement with IEEE.”
Fan, Y., Ma, Y., Zolotavin, P., Topalli, G., Wang, W., Karlsson, M. P., Karlsson, M., Luan, L., Xie, C., & Chi, T. (2026) · npj Biomedical Innovations. · doi:10.1038/s44385-026-00103-8 · Cited by 1
“The bonding parameters are as follows: ultrasonic generator power (USG) of 130 – 150 mW, bonding time of 40 – 70 ms, bonding force of 25 – 45 mN, and a USG ramp of 50%.”
Kmon, P., & Gryboś, P. (2015) · International Conference Mixed Design of Integrated Circuits and Systems · doi:10.1109/mixdes.2015.7208534 · Cited by 1
“These are mainly problems with treatment human nervous system disorders or with developing implantable systems for disabled persons assistance [1-3].”
BackgroundJitter in ultra-low power audio-range PLLs
Luo, F., & Fischer, G. (2012) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2012.6292079 · Cited by 1
“INTRODUCTION Ultra-lower power circuits are well suited for battery operated systems found in many wireless sensing applications or portable miniature biomedical devices, which mandate minimum power to provide maximum battery life [1], [2].”
BackgroundWireless wearable ECG sensor design based on level-crossing sampling and linear interpolation
Hong, Y., Xie, Z., & Lian, Y. (2013) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2013.6572092 · Cited by 1
Self-citationBio‐signal acquisition circuit with high signal‐to‐noise ratio for u‐healthcare system
Nam, I., Kang, H.-S., & Woo, D. H. (2014) · Electronics Letters · doi:10.1049/el.2014.3088 · Cited by 1
Low noise amplifier with active feedback structure for implantable neural recording
Li, H., Zhao, W. G., Shen, H., & Zhang, Y. (2013) · IEICE Electronics Express · doi:10.1587/elex.10.20130312 · Cited by 1
Qin, Y., Xu, W., Xiao, G., Deng, D., Gui, F., & Li, X. (2015) · CRC Press eBooks · doi:10.1201/b18776-29 · Cited by 1
Urine Microchip Sensing System
Luo, C., Syu, M., Shiesh, S., Lai, S.-C., Ma, W.-J., Juan, Y.-H., & Juang, W.-H. (2016) · Springer eBooks · doi:10.1007/978-3-319-33201-7_13 · Cited by 1
A low power relaxation oscillator with process insensitive auto-calibration scheme
Lu, X., Wang, B., Wen, Z., Zhao, X., Cao, Y., & Bermak, A. (2016) · IEEE Asia Pacific Conference on Circuits and Systems (APCCAS) · doi:10.1109/apccas.2016.7804068 · Cited by 1
A Successive Approximation ADC using PWM Technique for Bio-Medical Applications
Cleber, T., Della, G., Dutra, O. D. O., Paulo, C. C., Leonardo, B. A., & Ferreira, L. H. C. (2013) · InTech eBooks · doi:10.5772/51715 · Cited by 1
A wireless readout front-end device for portable EEG acquisition system
Chen, Y., Hsieh, Z.-H., & Fang, W.-C. (2013) · IEEE International Symposium on Consumer Electronics (ISCE) · doi:10.1109/isce.2013.6570196 · Cited by 1
“It is necessary to acquire the accurate biopotential, but its CMRR is usually limited by the mismatch while fabricating [6]–[7].”
BackgroundA low-power sensor interface circuit for remotely powered implants
Liu, X., & Dehollain, C. (2013) · Conference on Ph.D. Research in Microelectronics and Electronics · doi:10.1109/prime.2013.6603173 · Cited by 1
“Also, in order to adapt the vital bio-signals for disease identification or scientific research, such as EEG, heartbeats, blood pressure, and body temperature [2], the circuits needs to realize a moderate range of bandwidth and amplitude for various signals [3].”
BackgroundDubey, R., Kumar, A., & Pattanaik, M. (2014) · International Conference on Computing, Communication and Networking Technologies (ICCCNT) · doi:10.1109/icccnt.2014.6963111 · Cited by 1
“I. INTRODUCTION Rapid advances in miniature implantable microelectronics are accelerating the development in neuroscience and igniting the clinical research for operating the brain disorders [1]-[2] and [4]-[6].”
BackgroundA 1.83 μW, 0.78 μVrms input referred noise neural recording front end
Wu, J., Law, M. K., Mak, P., & Martins, R. P. (2013) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2013.6571866 · Cited by 1
“In [5], a tunable pseudo-resistor for DC offset cancellation was proposed, with the tradeoff of increased signal distortion.”
BackgroundLow-Voltage Analog-to-Digital Converters and Mixed-Signal Interfaces
Harikumar, P. (2015) · Linköping studies in science and technology. Dissertations · doi:10.3384/diss.diva-122730 · Cited by 1
“Specification [63] [1] [8] [64] This work Technology (nm) 350 65 65 65 65 Supply voltage (V) 1 0.”
PHIDIAS: ultra-low-power holistic design for smart bio-signals computing platforms
Bortolotti, D., Bartolini, A., Benini, L., Pamula, V. R., Helleputte, N. V., Hoof, C. A. V., Verhelst, M., Gemmeke, T., Braojos, R., Ansaloni, G., et al. (2016) · ACM International Conference on Computing Frontiers (CF) · doi:10.1145/2903150.2903469 · Cited by 1
Low Power Techniques for Analog Building Blocks of the Ultra Low Power Systems
Chen, Y. (2016) · Deep Blue (University of Michigan) · Cited by 1
A sub 125 nW sub-threshold analog adaptive sampler in 180 nm CMOS
Laurenson, C., Yuce, M. R., & Redouté, J. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8036926 · Cited by 1
“proposed a miniaturised implantable sensing device in 350 nm CMOS, which requires only 445 nW [5].”
BackgroundA 1.2-V 730-nW 10-Hz-3.5-kHz programmable biopotential front-end
Pulido, R., Santana-Abril, J., Sosa, J., & Montiel-Nelson, J. A. (2017) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2017.8053235 · Cited by 1
“It is composed by a tunable bandwidth frontend ampli er (TB-FEA) and a programmable gain stage (PGA) [2].”
BackgroundResultInfluentialA sub-μW bio-potential front end in 65nm CMOS
Kifle, Y., Saleh, H. H., Mohammad, B. S., & Ismail, M. (2017) · IFIP/IEEE International Conference on Very Large Scale Integration · doi:10.1109/vlsi-soc.2017.8203463 · Cited by 1
“Capacitive feedback instrumentation amplifier [11]-[14] with pseudo-resistors in the feedback for setting the dc path between the input and output and for high pass filter response presents a promising solution.”
BackgroundA 1.2 pJ/cycle KHz Timer Circuit for Heavily Duty-Cycled Systems
Manikandan, R. R., Singhal, V., Chauhan, R., Menezes, V., & Mehendale, M. M. (2018) · International Conference on VLSI Design · doi:10.1109/vlsid.2018.57 · Cited by 1
“Recent advances in the ultra low power sensor platforms and Internet-of-Things (IoT) led to a development of many new applications of environmental (temperature/gas/humidity sensors, thermostats, intruder detection) and health monitoring systems (blood glucose and eye pressure monitors) [1].”
BackgroundSelf-Powered SoC Platform for Wearable Health Care
Alhawari, M., Kilani, D., Habte, T. T., Kifle, Y., Bayasi, N., Elnaggar, I., Hallfors, N., Mohammad, B. S., Saleh, H. H., & Ismail, M. (2018) · Springer eBooks · doi:10.1007/978-3-319-93100-5_18 · Cited by 1
ECoG signal coding and digitization
Ha, S., Kim, C., Mercier, P. P., & Cauwenberghs, G. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815115-0.00010-6 · Cited by 1
Unity-Gain Zero-Offset CMOS Buffer with Improved Feedforward Path
Jendernalik, W., Jakusz, J., Piotrowski, R., Blakiewicz, G., & Szczepański, S. (2021) · Electronics · doi:10.3390/electronics10141613 · Cited by 1
Implement Tunable Sub-TΩ On-chip Resistor for Vital Signal Acquisition: A Review
Chen, M., Hao, Y., Qi, L., Li, Y., & Yan, J. (2021) · International SoC Design Conference · doi:10.1109/isocc53507.2021.9613917 · Cited by 1
“In [2], a bootstrapped-PR is adopted to realize tunable fHP and improve the linearity.”
MethodBontems, W., & Dzahini, D. (2023) · Chips · doi:10.3390/chips2010003 · Cited by 1
A novel interface architecture for differential capacitive sensors
Barile, G., Esposito, P., Stornelli, V., & Ferri, G. (2023) · International Workshop on Advances in Sensors and Interfaces (IWASI) · doi:10.1109/iwasi58316.2023.10164374 · Cited by 1
“In the methodology to design interfaces for capacitive sensors in the biomedical field, hybrid analog-digital systems are exploited, and capacitances are converted into a digital value mainly through the usage of Σ-Δ techniques [12], [13] or Successive Approximation Registers (SAR) [14], [15], both for single, differe…”
MethodSağlıcan, E., Dur, B., & Afacan, E. (2023) · International Conference on Synthesis, Modeling, Analysis and Simulation Methods and Applications to Circuit Design · doi:10.1109/smacd58065.2023.10192202 · Cited by 1
“Modern technology has enabled wearable devices for insitu measurements of several bio signals such as electrocardiogram (ECG), electroencephalogram (EEG), electromyogram (EMG), and axon action potential (AAP) [1]–[3].”
BackgroundA 4.0-μVrms 7.5-kHz-BW Neural Signal Recording Circuit for Closed-Loop Deep Brain Stimulation
Tian, R., Zhou, F., Xia, Q., You, Y., Lu, W., Zhang, Y., & Chen, Z. (2023) · International Conference on Integrated Circuits and Microsystems (ICICM) · doi:10.1109/icicm59499.2023.10365813 · Cited by 1
“A strategy proposed in [10] resues the C x as a part of the input capacitor in a large-gain configuration, eliminating the R x C x serial branch in the feedback loop, thus avoiding deteriorating frequency response.”
MethodAn ultra low power implantable neural recording system for brain-machine interfaces
Wattanapanitch, W. (2011) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 1
Nano-Watt Modular Integrated Circuits for Wireless Neural Interface.
Chang, S.-I. (2013) · Deep Blue (University of Michigan) · Cited by 1
Low-Power Low-Noise CMOS Analog and Mixed-Signal Design towards Epileptic Seizure Detection
Qian, C. (2013) · OakTrust (Texas A&M University Libraries) · Cited by 1
Design of an ultra low-power CMOS analog-to-digital converter for biomedical applications
Yuan, C. (2014) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/61732 · Cited by 1
“1: Voltage and frequency ranges of some conventional biomedical signals [9].”
BackgroundMethodRobust, Reconfigurable, and Power-Efficient Electrophysiological Recording Systems
Karkare, V. (2014) · eScholarship (California Digital Library) · Cited by 1
The development of a miniaturized hydration sensor based on the principle of osmotic pressure
Fernandes, L. A. L. (2017) · NORA - Norwegian Open Research Archives · Cited by 1
High performance filter and variable gain amplifier design for biosignal measurement devices
Wang, K. (2015) · Digital Repository Service (Northeastern University) · doi:10.17760/d20200519 · Cited by 1
Circuit and System Designs for Millimeter Scale IoT and Wireless Neural Recording
Jang, T. (2017) · Deep Blue (University of Michigan) · Cited by 1
Low Power Circuits for Smart Flexible ECG Sensors
Zhao, Y. (2020) · YorkSpace (York University) · Cited by 1
Low-Power Biopotential Signal Acquisition System for Biomedical Applications
Tasneem, N. T. (2022) · University of North Texas Digital Library (University of North Texas) · doi:10.12794/metadc1944354 · Cited by 1
Rummens, F. (2015) · theses.fr (ABES) · doi:10.70675/ac5d34b9zcd84z48cezb9fcz5d2b8e9edb14 · Cited by 1
“Alors que beaucoup d’auteurs s’appliquent à concevoir des amplificateurs linéaires (Reid R. Harrison & Charles, 2003), (Zou et al., 2009), (Zhang, Member, Holleman, Otis, & Member, 2012), d’autres tirent profit de la non-linéarité naturelle des transistors dans l’espoir d’amplifier le SNR des…”
BackgroundAn Ultra Low Power Fully Integrated Sensor Interface IC for Pacemakers
Al-Ahdab, S. (2009) · Research Repository (Delft University of Technology)
A sub-1µW, 16kHz Current-Mode SAR-ADC for Neural Spike Recording
Haaheim, B. (2011) · NORA - Norwegian Open Research Archives
Cross‐Hierarchy Design Exploration for Implantable Electronics
Sharad, M., & Roy, K. (2014) · Wiley eBooks · doi:10.1002/9783527673148.ch5
A 15-fJ/conversion-step 0.4-V 100-kS/s rail- to-rail 10-bit SARADC
Roshani, S., Salimpour, N., & Mohamadpour, G. (2014) · International Journal of Electronics Letters · doi:10.1080/21681724.2014.966773
A 700mV low power low noise implantable neural recording system design
An, G., Hutchens, C. G., & Rennaker, R. L. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6945130
A variable-gain superregenerative amplifier controlled by duty-cycle for signal conditioning
de Sousa, F. R., & Antayhua, R. A. R. (2014) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-014-0473-z
Low Power Analog Front End for ExG Acquisition with Automatic Gain Control and Analog Classification
Naik, J. (2015) · Research Archive of Indian Institute of Technology Hyderabad (Indian Institute of Technology Hyderabad)
Design of Ultra-Low-Power Electrocardiography Sensors
Zhang, X., Li, Y., Wang, L., Zou, W., Sun, Y., Liu, Y., Yang, H., Lian, Y., & Zhao, B. (2015) · Springer eBooks · doi:10.1007/978-3-319-14711-6_14
“Wearable wireless ECG sensor is one of the best candidates for continuous heart condition monitoring [2–5].”
BackgroundSelf-citationKuang, X., & Fang, X. (2015) · IEEE International Conference on Communication Technology (ICCT) · doi:10.1109/icct.2015.7399897
Analog and Mixed Signal Design towards a Miniaturized Sleep Apnea Monitoring Device
Jin, J. (2014) · OakTrust (Texas A&M University Libraries)
Oreggioni, J., Lisboa, P. C., & Silveira, F. (2016) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.2188
“[2], based on capacitors for alternating current (ac) coupling and MOS-bipolar high valued pseudo-resistors, is widely used [3, 4].”
BackgroundPower and area efficient continuous time ΣΔ modulator based on local feedback
López-Morillo, E., Muñoz, F., Torralba, A., Galán, J., Márquez, F., & Carvajal, R. G. (2016) · Microelectronics Journal · doi:10.1016/j.mejo.2016.04.017
“Algorithmic data converter architectures, like the Successive Approximation Register (SAR), are the most common choice for moderate resolution specifications (less than 10 bits) when ultralow power consumption is required, which is the case of RFID systems [2] or wearable biomedical signal acquisition systems [3].”
BackgroundSensor signal conditioning circuit design for multi-electrode intra-cortical recording
Yi, C. (2014) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/62570
“A balanced t uneable pseudo-resistors structure is proposed by [69], as depicted in Fig.”
Background
Metadata
- Authors
- Zou, X., Xu, X., Yao, L., & Lian, Y.
- Affiliations
- National University of Singapore (SG)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2009-04
- Volume
- 44
- Issue
- 4
- Pages
- 1067-1077
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2152776190
- Cited by
- 414
- References
- 10
- Citations by year
- 2026: 6 · 2025: 16 · 2024: 16 · 2023: 9 · 2022: 12 · 2021: 22 · 2020: 25 · 2019: 29 · 2018: 27 · 2017: 31 · 2016: 35 · 2015: 35 · 2014: 40 · 2013: 31 · 2012: 29
- FWCI
- 16.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- National University of Singapore (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- low-power analog front-end, low-voltage operation, low noise amplifier, tunable bandpass filter, successive approximation register ADC, relaxation oscillator, heartbeat detection, ECG recording, noise efficiency factor, CMOS integrated circuit
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.