The DOI matches its Crossref record; 26 of the 27 references it cites were found in a registry or an index.
A 0.013 ${\hbox {mm}}^{2}$, 5 $\mu\hbox{W}$, DC-Coupled Neural Signal Acquisition IC With 0.5 V Supply
Abstract
We present an area-efficient neural signal-acquisition system that uses a digitally intensive architecture to reduce system area and enable operation from a 0.5 V supply. The architecture replaces ac coupling capacitors and analog filters with a dual mixed-signal servo loop, which allows simultaneous digitization of the action and local field potentials. A noise-efficient DAC topology and an compact, boxcar sampling ADC are used to cancel input offset and prevent noise folding while enabling “per-pixel” digitization, alleviating system-level complexity. Implemented in a 65 nm CMOS process, the prototype occupies 0.013 mm2while consuming 5 μW and achieving 4.9 μVrms of input-referred noise in a 10 kHz bandwidth.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, modern circuit designs [77, 92] and IC fabrication technologies [18, 86] have resulted in innovative designs, enabling designers to relax such compromises.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [86]
In the citing paper
“CNS amplifiers have also been developed that can acquire both types of signals, separately filtering, amplifying and outputting each signal type [46, 86, 100].”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [86]
In the citing paper
“Recently, Muller et al. [86] introduced the power efficiency factor (PEF), which takes into account both the operating current and the supply voltage and therefore provides a better comparison of the amplifier’s performance.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [86]
Citations
Cites
Operation and modeling of the MOS transistor
Tsividis, Y. (1987) · Cited by 3,162
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R. R., Watkins, P., Kier, R. J., Lovejoy, R. O., Black, D., Normann, R. A., & Solzbacher, F. (2006) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2006.1696288 · Cited by 728
Impedance Characterization and Modeling of Electrodes for Biomedical Applications
Franks, W., Schenker, I., Schmutz, P., & Hierlemann, A. R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847523 · Cited by 660
Emergence of a stable cortical map for neuroprosthetic control
Ganguly, K., & Carmena, J. M. (2009) · PLoS Biology · doi:10.1371/journal.pbio.1000153 · Cited by 578
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
0.5-V analog circuit techniques and their application in OTA and filter design
Chatterjee, S., Tsividis, Y., & Kinget, P. R. (2005) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2005.856280 · Cited by 503
An Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441
Flagged first, then by citations
1 of the 27 references couldn’t be matched to a known paper.
Research works printed but not linked: 2
- xiao, 2010, A 20 <ref_formula><tex Notation="TeX">$\mu{W}$</tex> </ref_formula> neural recording tag with supply-current-modulated AFE in 0.13 <ref_formula> <tex Notation="TeX">$\mu{\hbox {m}}$</tex></ref_formula> CMOS, IEEE Solid-State Circuits Conf Dig Tech Papers, 122
- muller, 2011, A 0.013 <ref_formula><tex Notation="TeX">${\hbox {mm}}^{2}$</tex></ref_formula>, 5 <ref_formula><tex Notation="TeX">$\mu{W}$</tex> </ref_formula>, DC-coupled neural signal acquisition IC with 0.5 V supply, IEEE Solid-State Circuits Conf Dig Tech Papers, 302
Cited by
Sorted by citations
Items 101–200 of 338
A DC-connectable multi-channel biomedical data acquisition ASIC with mains frequency cancellation
Schönle, P., Schulthess, F., Fateh, S., Ulrich, R., Huang, F., Burger, T., & Huang, Q. (2013) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2013.6649094 · Cited by 27
Rodríguez‐Pérez, A., Delgado‐Restituto, M., & Medeiro, F. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2270180 · Cited by 27
An ultra-low-power neural signal acquisition analog front-end IC
Tran, L., & Cha, H.-K. (2021) · Microelectronics Journal · doi:10.1016/j.mejo.2020.104950 · Cited by 26
Jiang, W., Hokhikyan, V., Chandrakumar, H., Karkare, V., & Markovic, D. M. (2016) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2016.7418118 · Cited by 26
Omnidirectional Wireless Power Transfer for Millimetric Magnetoelectric Biomedical Implants
Wang, W., Yu, Z., Zou, Y., Woods, J. E., Chari, P., Su, Y., Robinson, J. T., & Yang, K. (2024) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2024.3464533 · Cited by 26
A 0.5 V 68 nW ECG Monitoring Analog Front-End for Arrhythmia Diagnosis
Kosari, A., Breiholz, J., Liu, N., Calhoun, B. H., & Wentzloff, D. D. (2018) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea8030027 · Cited by 25
Analog Front-End Input-Impedance Boosting Techniques for Bio-Potential Monitoring—A Review
Yan, F., & Liu, J. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3370766 · Cited by 25
Khan, M. W. A., Björninen, T., Sydanheimo, L. T., & Ukkonen, L. (2015) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2015.2511187 · Cited by 24
Pham, X. T., Nguyen, N. T., Nguyen, V.-N., & Lee, J. (2021) · IEEE Access · doi:10.1109/access.2021.3087737 · Cited by 25
A Direct Digitizing Chopped Neural Recorder Using a Body-Induced Offset Based DC Servo Loop
Sporer, M., Reich, S., Kauffman, J. G., & Ortmanns, M. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3177241 · Cited by 24
An Adaptive Averaging Low Noise Front-End for Central and Peripheral Nerve Recording
Lee, B., & Ghovanloo, M. (2017) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2017.2725988 · Cited by 24
A Low-Noise, Wireless, Frequency-Shaping Neural Recorder
Xu, J., Nguyen, A. T., Zhao, W., Guo, H., Wu, T., Wiggins, H., Keefer, E. W., Lim, H. H., & Yang, Z. (2018) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2018.2812104 · Cited by 24
A 0.006 mm2 1.2 $\mu$ W Analog-to-Time Converter for Asynchronous Bio-Sensors
Leene, L. B., & Constandinou, T. G. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2850918 · Cited by 24
Greenwald, E., Masters, M. R., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1452-6 · Cited by 23
A Low Noise Amplifier for Neural Spike Recording Interfaces
Ruiz-Amaya, J., Rodriguez-Perez, A., & Delgado-Restituto, M. (2015) · Sensors · doi:10.3390/s151025313 · Cited by 23
A Bidirectional Neuromodulation Technology for Nerve Recording and Stimulation
Xu, J., Guo, H., Nguyen, A. T., Lim, H. H., & Yang, Z. (2018) · Micromachines · doi:10.3390/mi9110538 · Cited by 23
432 nW per Channel 130 nV/rtHz ECG Acquisition Front End With Multifrequency Chopping
Khatavkar, P., & Aniruddhan, S. (2019) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2019.2910202 · Cited by 23
Hsu, Y.-P., Liu, Z., & Hella, M. M. (2018) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2018.2809470 · Cited by 23
Emerging Trends of Biomedical Circuits and Systems
Sawan, M., Yang, J., Tarkhan, M., Chen, J., Wang, M., Wang, C., Xia, F., & Chen, Y.-H. (2021) · Foundations and Trends® in Integrated Circuits and Systems · doi:10.1561/3500000005 · Cited by 23
A 768-Channel CMOS Microelectrode Array With Angle Sensitive Pixels for Neuronal Recording
Johnson, B. C., Peace, S. T., Wang, A. Z., Cleland, T. A., & Molnar, A. C. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2266894 · Cited by 22
A fully-integrated 16-channel EEG readout front-end for neural recording applications
Nasserian, M., Peiravi, A., & Moradi, F. (2018) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2018.06.045 · Cited by 22
An 800MΩ-Input-Impedance 95.3dB-DR Δ-ΔΣ AFE for Dry-Electrode Wearable EEG Recording
Li, Y., Li, Y., Li, H., Hong, Z., & Xu, J. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3374891 · Cited by 21
Huang, X., Ballini, M., Wang, S., Miccoli, B., Hoof, C. A. V., Gielen, G. E., Craninckx, J., Helleputte, N. V., & López, C. M. (2021) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2021.3111257 · Cited by 22
Valtierra, J. L., Delgado‐Restituto, M., Fiorelli, R., & Rodriguez-Vazquez, A. (2020) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2020.2968087 · Cited by 20
Luo, D., Lei, J., Zhang, M., & Wang, Z. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3038632 · Cited by 23
Recording Strategies for High Channel Count, Densely Spaced Microelectrode Arrays
Pérez-Prieto, N., & Delgado‐Restituto, M. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.681085 · Cited by 23
Smith, W. A., Mogen, B. J., Fetz, E. E., Sathe, V., & Otis, B. P. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2518923 · Cited by 20
A 2.46-mm2 Miniaturized Brain-Machine Interface (MiBMI) Enabling 31-Class Brain-to-Text Decoding
Shaeri, M., Shin, U., Yadav, A., Caramellino, R., Rainer, G., & Shoaran, M. (2024) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2024.3443254 · Cited by 19
From Wearables to Implantables: Harnessing Sensor Technologies for Continuous Health Monitoring
Koruprolu, A., Hack, T., Ghadami, O., Jain, A., & Hall, D. A. (2025) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2025.3568754 · Cited by 20
A 4-μW Analog Front End Achieving 2.4 NEF for Long-Term ECG Monitoring
Yang, W., Jiang, H., Yin, Y., & Wang, Z. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3084152 · Cited by 19
Design considerations for neural amplifiers
Holleman, J. H. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592176 · Cited by 19
Low-power wide-bandwidth CMOS indirect current feedback instrumentation amplifier
Carrillo, J. M., Dominguez, M. A., Perez-Aloe, R., Cruz‐Blas, C. A. D. L., & Duque-Carrillo, J. F. (2020) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2020.153299 · Cited by 19
Kassiri, H., Muneeb, A., Salahi, R., & Dabbaghian, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3456825 · Cited by 19
Energy-efficient bridge-to-digital converters
Jiang, H., & Makinwa, K. A. A. (2018) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2018.8357027 · Cited by 18
Ashayeri, M., & Yavari, M. (2021) · Microelectronics Journal · doi:10.1016/j.mejo.2021.105333 · Cited by 18
Park, S., Cho, J., Lee, K., & Yoon, E. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2501304 · Cited by 18
Low-Voltage Low-Noise High-CMRR Biopotential Integrated Preamplifier
Cabrera, C., Caballero, R., Costa-Rauschert, M. C., Rossi-Aicardi, C., & Oreggioni, J. (2020) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2020.3035357 · Cited by 18
Lee, H.-S., Eom, K., Park, M., Ku, S.-B., Lee, K., Kim, T., Kim, T.-K., Shon, Y., Park, H., & Lee, H. (2023) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2023.3268686 · Cited by 17
A Fully Digital Front-End Architecture for ECG Acquisition System With 0.5 V Supply
Zare, M., & Maymandi‐Nejad, M. (2015) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2015.2395540 · Cited by 17
A chopper-stabilized instrumentation amplifier using area-efficient self-trimming technique
Akita, I., & Ishida, M. (2014) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-014-0371-4 · Cited by 17
Design and optimization of mm-size implantable and wearable on-body antennas for biomedical systems
Amendola, S., Moradi, E., Koski, K., Björninen, T., Sydanheimo, L. T., Ukkonen, L., Rabaey, J. M., & Rahmat‐Samii, Y. (2014) · European Conference on Antennas and Propagation · doi:10.1109/eucap.2014.6901807 · Cited by 17
Self-citationA Wide Linear Output Range Biopotential Amplifier for Physiological Measurement Frontend
Hasan, M. N., & Lee, K. (2014) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2014.2332240 · Cited by 17
Londoño‐Ramírez, H., Huang, X., Cools, J., Chrzanowska, A., Brunner, C., Ballini, M., Hoffman, L., Steudel, S., Rolin, C., López, C. M., et al. (2023) · Advanced Science · doi:10.1002/advs.202308507 · Cited by 20
Xu, J., Busze, B., Kim, H. J., Makinwa, K. A. A., Hoof, C. A. V., & Yazıcıoğlu, R. F. (2014) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2014.6757498 · Cited by 16
High-density neural recording system design
Lee, H.-S., Eom, K., Park, M., Ku, S.-B., Lee, K., & Lee, H.-M. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00233-z · Cited by 17
A 255nW ultra-high input impedance analog front-end for non-contact ECG monitoring
Lee, J., Kim, H., & Cho, S. (2017) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2017.7993707 · Cited by 15
Corbacho, I., Carrillo, J. M., Ausín, J. L., Dominguez, M. A., Perez-Aloe, R., & Duque-Carrillo, J. F. (2022) · Electronics · doi:10.3390/electronics11111668 · Cited by 14
Design of Low Power and Low Noise Instrumentation Amplifier for Biopotential Acquisition: A Review
Koo, N. (2025) · IEEE Access · doi:10.1109/access.2025.3537998 · Cited by 18
Uran, A., Leblebici, Y., Emami, A., & Cevher, V. (2020) · IEEE Solid-State Circuits Letters · doi:10.1109/lssc.2020.3013993 · Cited by 14
Cho, J., Seong, G., Chang, Y., & Kim, C. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.667447 · Cited by 18
Ultralow-Voltage High-Speed Flash ADC Design Strategy Based on FoM-Delay Product
Lin, J., Mano, I., Miyahara, M., & Matsuzawa, A. (2014) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2014.2340995 · Cited by 14
Chang, C., Chou, L.-C., Huang, P.-T., Wu, S.-L., Lee, S.-W., Chuang, C.-T. K., Chen, K., Hwang, W., Chen, K.-H., Chiu, C.-T., et al. (2015) · Biomedical Microdevices · doi:10.1007/s10544-014-9906-9 · Cited by 14
A 64-channel ultra-low power bioelectric signal acquisition system for brain-computer interface
Mahajan, A., Karimi-Bidhendi, A., Wang, P. T., McCrimmon, C. M., Liu, C. Y., Nenadić, Z., Do, A. H., & Heydari, P. (2015) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2015.7348355 · Cited by 14
A 2.89-μW clockless wireless dry-electrode ECG SoC for wearable sensors
Zhang, X., Zhang, Z., Li, Y., Liu, C., Guo, Y., & Lian, Y. (2015) · IEEE Asian Solid-State Circuits Conference (A-SSCC) · doi:10.1109/asscc.2015.7387498 · Cited by 14
Zulqarnain, M., Stanzione, S., van der Steen, J.-L. P. J., Gelinck, G. H., Abdinia, S., & Cantatore, E. (2018) · Flexible and Printed Electronics · doi:10.1088/2058-8585/aaf4d3 · Cited by 14
Plugging Electronics Into Minds: Recent Trends and Advances in Neural Interface Microsystems
Kim, M. K., Jeon, H., Lee, H. J., & Je, M. (2019) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2019.2939337 · Cited by 13
NeuroBus - Architecture for an Ultra-Flexible Neural Interface
Sporer, M., Vasilaş, I.-G., Adžemović, A., Graber, N., Reich, S., Gueli, C., Eickenscheidt, M., Diester, I., Stieglitz, T., & Ortmanns, M. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3354785 · Cited by 13
A low-power low-noise neural recording amplifier with an improved recycling telescopic-cascode OTA
Mohtashamnia, M., & Yavari, M. (2022) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2022.154312 · Cited by 14
Robust, reconfigurable, and power-efficient biosignal recording systems
Karkare, V., Chandrakumar, H., Rozgic, D., & Markovic, D. M. (2014) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2014.6946018 · Cited by 13
A 50 μW/Ch artifacts-insensitive neural recorder using frequency-shaping technique
Xu, J., & Yang, Z. (2013) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2013.6658532 · Cited by 13
Design of Low-Voltage Digital Building Blocks and ADCs for Energy-Efficient Systems
Sinangil, M. E., Yip, M., Qazi, M., Rithe, R., Kwong, J., & Chandrakasan, A. P. (2012) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2012.2208675 · Cited by 13
Large-Scale, High-Resolution Microelectrode Arrays for Interrogation of Neurons and Networks
Obien, M. E. J., & Frey, U. (2019) · Advances in neurobiology · doi:10.1007/978-3-030-11135-9_4 · Cited by 12
Survey on various architectures of preamplifiers for electroencephalogram (EEG) signal acquisition
Devi, S., Guha, K., Baishnab, K. L., Iannacci, J., & Narayan, K. S. (2022) · Microsystem Technologies · doi:10.1007/s00542-022-05253-4 · Cited by 12
A New System Architecture for Future Long-Term High-Density Neural Recording
Xu, J., Wu, T. F., & Yang, Z. (2013) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2013.2258270 · Cited by 12
Self-Biased Ultralow Power Current-Reused Neural Amplifier With On-Chip Analog Spike Detections
Kim, J., & Ko, H. (2019) · IEEE Access · doi:10.1109/access.2019.2933674 · Cited by 12
Pham, X. T., Kieu, X. T., & Hoàng, M. K. (2023) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea13020037 · Cited by 12
Nam, G., Choi, G., Yoo, M., Kang, S., Jin, B., Son, H., Kim, K., Wi, J., Ahn, S., & Ko, H. (2023) · IEEE Access · doi:10.1109/access.2023.3340427 · Cited by 11
Low-Noise Operational Amplifier Using Dual-Path Dual-Chopper Fill-in Technique
Yoo, M., Kang, S., Jin, B., Son, H., Kim, K., Wi, J., Nam, G., Bae, N. H., & Ko, H. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3368023 · Cited by 11
Anti-artifacts techniques for neural recording front-ends in closed-loop brain-machine interface ICs
Chen, W., Liu, X., Wan, P., Chen, Z., & Chen, Y. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1393206 · Cited by 10
Yoo, M., Son, H., Kim, K., Wi, J., Nam, G., Son, M., Choi, M., & Ko, H. (2024) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2024.3470833 · Cited by 11
Brain‐Computer Interfaces Using Flexible Electronics: An a‐IGZO Front‐End for Active ECoG Electrodes
van Oosterhout, K., Chilundo, A., Branco, M. P., Aarnoutse, E. J., Timmermans, M., Fattori, M., Ramsey, N. F., & Cantatore, E. (2024) · Advanced Science · doi:10.1002/advs.202408576 · Cited by 11
An implantable mixed-signal CMOS die for battery-powered in vivo blowfly neural recordings
Yue, X. A., Huang, J., Krapp, H. G., & Drakakis, E. M. (2018) · Microelectronics Journal · doi:10.1016/j.mejo.2018.01.022 · Cited by 11
A power efficient low-noise source degenerated bio-potential amplifier
Venishetty, S. R., Kumaravel, S., & Durai, S. A. (2020) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-020-01628-7 · Cited by 11
Pham, X. T., Nguyen, V.-N., Kim, J.-S., & Lee, J. (2020) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2020.3045491 · Cited by 11
Low-power integrated circuits for wearable electrophysiology
Ha, S., Kim, C., Wang, H., Yu, M., Mercier, P. P., & Cauwenberghs, G. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819246-7.00006-1 · Cited by 11
Hao, Y., Chen, M., Chen, W., Zhao, Y., & Li, Y. (2021) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2021.3065973 · Cited by 11
A configurable 5.9 μW analog front-end for biosignal acquisition
Tan, Y., Lu, J., Jahan, M. S., Griffin, K., Langford, J., & Holleman, J. H. (2015) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2015.7338491 · Cited by 11
Using biopotential and bio-impedance for intuitive human–robot interaction
Park, K., Jeong, H., Jung, Y., Suh, J.-H., Je, M., & Kim, J. (2025) · Nature Reviews Electrical Engineering · doi:10.1038/s44287-025-00191-5 · Cited by 10
Cha, J.-H., Park, J.-H., Park, Y., Shin, H., Hwang, K. S., Cho, I., & Kim, S. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3211275 · Cited by 10
Fathy, N. S. K., Vatsyayan, R., Bourhis, A. M., Dayeh, S. A., & Mercier, P. P. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3366649 · Cited by 11
2.5D Heterogeneously Integrated Microsystem for High-Density Neural Sensing Applications
Huang, P.-T., Wu, S.-L., Huang, Y., Chou, L.-C., Huang, T.-C., Wang, T.-H., Lin, Y.-R., Cheng, C.-A., Shen, W.-W., Chuang, C.-T. K., et al. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2385061 · Cited by 10
Time-Based Sensor Interface for Dopamine Detection
Olabode, O., Kosunen, M., Unnikrishnan, V., Palomäki, T., Laurila, T. T., Halonen, K. A. I., & Ryynänen, J. (2020) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2020.3008363 · Cited by 10
A Very Low SEF Neural Amplifier by Utilizing a High Swing Current-Reuse Amplifier
Naderi, K., Shad, E. H. T., Molinas, M., Heidari, A., & Ytterdal, T. (2020) · Conference on Design of Circuits and Integrated Systems · doi:10.1109/dcis51330.2020.9268627 · Cited by 10
Oh, S., Song, H., Slager, N., Ruiz, J. R. L., Park, S., & Yoon, E. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3298662 · Cited by 12
Fan, X., Gao, F., & Pak Kwong, C. H. A. N. (2023) · Sensors · doi:10.3390/s23249808 · Cited by 9
A dual slope charge sampling analog front-end for a wireless neural recording system
Lee, S. B., Lee, B., Gosselin, B. J., & Ghovanloo, M. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944287 · Cited by 9
Pourahmad, A., Dehghani, R., & Mehr, S. A. R. A. (2021) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2020.153585 · Cited by 9
A Chopper-Stabilized Switched-Capacitor Front-End for Peripheral Nervous System Recording
Liu, J., & Allstot, D. J. (2023) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2023.3282555 · Cited by 9
A low-power current-reuse analog front-end for multi-channel neural signal recording
Sepehrian, H., Mirbozorgi, S. A., & Gosselin, B. J. (2014) · IEEE International New Circuits and Systems Conference (NEWCAS) · doi:10.1109/newcas.2014.6934077 · Cited by 9
Low-Cutoff Frequency Reduction in Neural Amplifiers: Analysis and Implementation in CMOS 65 nm
Noshahr, F. H., Nabavi, M., Gosselin, B. J., & Sawan, M. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.667846 · Cited by 10
Vejdani, P., & Nabki, F. (2019) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2019.2893861 · Cited by 9
A 14-ENOB Delta-Sigma-Based Readout Architecture for ECoG Recording Systems
Ivanisevic, N., Rodriguez, S., & Rusu, A. (2018) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2018.2838135 · Cited by 9
Koleibi, E. R., Lemaire, W., Koua, K., Benhouria, M., Bostani, R., Mazandarani, M. S., Gauthier, L.-P., Besrour, M., Ménard, J., Majdoub, M., et al. (2025) · Sensors · doi:10.3390/s25072320 · Cited by 10
A closed-loop neural recording analog front-end with low noise and automatic gain control amplifiers
Mohtashamnia, M., & Yavari, M. (2025) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2025.155976 · Cited by 7
A High Performance Delta-Sigma Modulator for Neurosensing
Xu, J., Zhao, M., Wu, X., Islam, M., & Yang, Z. (2015) · Sensors · doi:10.3390/s150819466 · Cited by 8
A 0.25V 460nW asynchronous neural signal processor with inherent leakage suppression
Liu, T.-T., & Rabaey, J. M. (2012) · Symposium on VLSI Circuits · doi:10.1109/vlsic.2012.6243838 · Cited by 8
Self-citationA 0.5-V 250-nW 65-dB SNDR passive ΔΣ modulator for medical implant devices
Yeknami, A. F., & Alvandpour, A. (2013) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2013.6572265 · Cited by 8
A 0.672 μW, 2 μVrms CMOS Current-Feeback ECG Pre-amplifier With 77 dB CMRR
Pantuprecharat, P., Masaree, S., Pawarangkoon, P., & Sawigun, C. (2019) · IEEE Asia Pacific Conference on Circuits and Systems (APCCAS) · doi:10.1109/apccas47518.2019.8953079 · Cited by 8
Lee, T., Park, J.-H., Chou, N., Cho, I., Kim, S., & Je, M. (2021) · IEEE Access · doi:10.1109/access.2021.3107299 · Cited by 9
Dynamic-Range-Enhancement Techniques for Artifact-Tolerant Biopotential-Acquisition ICs
Jung, Y., Kweon, S.-J., Lee, T., Jeong, K., Ha, S., & Je, M. (2022) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2022.3176272 · Cited by 8
Metadata
- Authors
- Muller, R., Gambini, S., & Rabaey, J. M.
- Affiliations
- University of California, Berkeley (US)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2012-01
- Volume
- 47
- Issue
- 1
- Pages
- 232-243
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2003444784
- Cited by
- 338
- References
- 27
- Citations by year
- 2026: 11 · 2025: 23 · 2024: 18 · 2023: 21 · 2022: 22 · 2021: 26 · 2020: 26 · 2019: 25 · 2018: 34 · 2017: 28 · 2016: 25 · 2015: 26 · 2014: 26 · 2013: 20 · 2012: 7
- FWCI
- 10.04
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- neural signal acquisition, low-power integrated circuits, local field potentials, digital-to-analog converter, noise folding, low-voltage operation, 65 nm CMOS, area-efficient circuit design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review