A Low Noise Amplifier for Neural Spike Recording Interfaces
Open accessAbstract
This paper presents a Low Noise Amplifier (LNA) for neural spike recording applications. The proposed topology, based on a capacitive feedback network using a two-stage OTA, efficiently solves the triple trade-off between power, area and noise. Additionally, this work introduces a novel transistor-level synthesis methodology for LNAs tailored for the minimization of their noise efficiency factor under area and noise constraints. The proposed LNA has been implemented in a 130 nm CMOS technology and occupies 0.053 mm-sq. Experimental results show that the LNA offers a noise efficiency factor of 2.16 and an input referred noise of 3.8 μVrms for 1.2 V power supply. It provides a gain of 46 dB over a nominal bandwidth of 192 Hz–7.4 kHz and consumes 1.92 μW. The performance of the proposed LNA has been validated through in vivo experiments with animal models.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A common element of integrated recording systems is an operational transconductance amplifier (OTA), used as the active amplifying element and can be implemented using a variety of techniques.
“A common element of integrated recording systems is an operational transconductance amplifier (OTA), used as the active amplifying element and can be implemented using a variety of techniques [157], [167].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [167]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · see citing works
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875 · see citing works
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695 · see citing works
Enz, C., Krummenacher, F., & Vittoz, E. A. (1995) · Analog Integrated Circuits and Signal Processing · doi:10.1007/bf01239381 · Cited by 1,234 · see citing works
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792 · see citing works
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782 · see citing works
A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R. R., Watkins, P., Kier, R. J., Lovejoy, R. O., Black, D., Normann, R. A., & Solzbacher, F. (2006) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2006.1696288 · Cited by 731 · see citing works
Impedance Characterization and Modeling of Electrodes for Biomedical Applications
Franks, W., Schenker, I., Schmutz, P., & Hierlemann, A. R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847523 · Cited by 660 · see citing works
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577 · see citing works
An Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441 · see citing works
A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
Zou, X., Xu, X., Yao, L., & Lian, Y. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2014707 · Cited by 414 · see citing works
A 128-Channel 6 mW Wireless Neural Recording IC With Spike Feature Extraction and UWB Transmitter
Chae, M. S., Yang, Z., Yuce, M. R., Hoang, L., & Liu, W. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2021607 · Cited by 369 · see citing works
Muller, R., Gambini, S., & Rabaey, J. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2163552 · Cited by 338 · see citing works
The Design of Integrated Circuits to Observe Brain Activity
Harrison, R. R. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922581 · Cited by 330 · see citing works
Toward a comparison of microelectrodes for acute and chronic recordings
Ward, M. P., Rajdev, P., Ellison, C., & Irazoqui, P. P. (2009) · Brain Research · doi:10.1016/j.brainres.2009.05.052 · Cited by 296 · see citing works
An Implantable 455-Active-Electrode 52-Channel CMOS Neural Probe
Lopez, C. M., Andrei, A., Mitra, S., Welkenhuysen, M., Eberle, W., Bartic, C., Puers, R., Yazicioglu, R. F., & Gielen, G. G. E. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284347 · Cited by 264 · see citing works
The 128-Channel Fully Differential Digital Integrated Neural Recording and Stimulation Interface
Shahrokhi, F., Abdelhalim, K., Serletis, D., Carlen, P. L., & Genov, R. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2041350 · Cited by 263 · see citing works
Design of Ultra-Low Power Biopotential Amplifiers for Biosignal Acquisition Applications
Zhang, F., Holleman, J. H., & Otis, B. P. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2177089 · Cited by 237 · see citing works
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220 · see citing works
An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording
Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2023159 · Cited by 218 · see citing works
Single-unit neural recording with active microelectrode arrays
Bai, Q., & Wise, K. D. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.936367 · Cited by 214 · see citing works
A Mixed-Signal Multichip Neural Recording Interface With Bandwidth Reduction
Gosselin, B. J., Ayoub, A. E., Roy, J.-F., Sawan, M., Leporé, F., Chaudhuri, A., & Guitton, D. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2013718 · Cited by 203 · see citing works
A Low-Power Integrated Bioamplifier With Active Low-Frequency Suppression
Gosselin, B. J., Sawan, M., & Chapman, C. A. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.914490 · Cited by 174 · see citing works
A Fully Integrated Neural Recording Amplifier With DC Input Stabilization
Mohseni, P., & Najafi, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.824126 · Cited by 173 · see citing works
Energy Efficient Low-Noise Neural Recording Amplifier With Enhanced Noise Efficiency Factor
Majidzadeh, V., Schmid, A., & Leblebici, Y. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078815 · Cited by 165 · see citing works
A Micropower Low-Noise Neural Recording Front-End Circuit for Epileptic Seizure Detection
Qian, C., Parramon, J., & Sanchez-Sinencio, E. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2126370 · Cited by 145 · see citing works
A 5 $\mu$W/Channel Spectral Analysis IC for Chronic Bidirectional Brain–Machine Interfaces
Avestruz, A.-T., Santa, W. A., Carlson, D., Jensen, R. M., Stanslaski, S. R., Helfenstine, A., & Denison, T. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006460 · Cited by 143 · see citing works
Recent Advances in Neural Recording Microsystems
Gosselin, B. (2011) · Sensors · doi:10.3390/s110504572 · Cited by 138 · see citing works
Eliasmith, C. (2002) · Cited by 134 · see citing works
A 100-Channel 1-mW Implantable Neural Recording IC
Zou, X., Liu, L., Cheong, J. H., Yao, L., Li, P., Cheng, M.-Y., Goh, W. L., Rajkumar, R., Dawe, G. S., Cheng, K.-W., et al. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2013.2249175 · Cited by 132 · see citing works
Perelman, Y., & Ginosar, R. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883732 · Cited by 116 · see citing works
Analysis and Design of Tunable Amplifiers for Implantable Neural Recording Applications
Rezaee-Dehsorkh, H., Ravanshad, N., Lotfi, R., Mafinezhad, K., & Sodagar, A. M. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2174492 · Cited by 103 · see citing works
A vertically integrated tool for automated design of ΣΔ modulators
Medeiro, F., Pérez-Verdú, B., Rodriguez-Vazquez, A., & Huertas, J. L. (1995) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.391115 · Cited by 97 · see citing works
Stimulus-activated changes in brain tissue temperature in the anesthetized rat
LaManna, J. C., McCracken, K. A., Patil, M., & Prohaska, O. J. (1989) · Metabolic Brain Disease · doi:10.1007/bf00999769 · Cited by 94 · see citing works
Joye, N., Schmid, A., & Leblebici, Y. (2009) · Neurocomputing · doi:10.1016/j.neucom.2009.09.006 · Cited by 70 · see citing works
An Area-Efficient Noise-Adaptive Neural Amplifier in 130 nm CMOS Technology
Chaturvedi, V., & Amrutur, B. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2178731 · Cited by 60 · see citing works
A 500µW neural tag with 2µVrms AFE and frequency-multiplying MICS/ISM FSK transmitter
Rai, S., Holleman, J. H., Pandey, J., Zhang, F., & Otis, B. P. (2009) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2009.4977383 · Cited by 54 · see citing works
A 1-V 60-µW 16-channel interface chip for implantable neural recording
Liew, W.-S., Zou, X., Yao, L., & Lian, Y. (2009) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2009.5280795 · Cited by 43 · see citing works
A CMOS Power-Efficient Low-Noise Current-Mode Front-End Amplifier for Neural Signal Recording
Wu, C., Chen, W., & Kuo, L.-T. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2256422 · Cited by 40 · see citing works
Chang, C., & Chiou, J. (2013) · Sensors · doi:10.3390/s130404624 · Cited by 35 · see citing works
An Implantable Neural Sensing Microsystem with Fiber-Optic Data Transmission and Power Delivery
Park, S., Borton, D. A., Kang, M., Nurmikko, A. V., & Song, Y. (2013) · Sensors · doi:10.3390/s130506014 · Cited by 34 · see citing works
A low-noise integrated bioamplifier with active DC offset suppression
Zhao, W. G., Li, H., & Zhang, Y. (2009) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2009.5372099 · Cited by 31 · see citing works
He, B. (2013) · Springer eBooks · doi:10.1007/978-1-4614-5227-0 · Cited by 31 · see citing works
A 1V 22µW 32-channel implantable EEG recording IC
Zou, X., Liew, W.-S., Yao, L., & Lian, Y. (2010) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2010.5434024 · Cited by 30 · see citing works
Advances in Microelectronics for Implantable Medical Devices
Demosthenous, A. (2014) · Advances in Electronics · doi:10.1155/2014/981295 · Cited by 27 · see citing works
Ruiz‐Amaya, J., Delgado‐Restituto, M., & Rodriguez-Vazquez, A. (2011) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2011.2157746 · Cited by 15 · see citing works
Self-citation
Flagged first, then by citations
1 of the 47 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Multi-Channel Neural Recording Implants: A Review
Hashemi Noshahr, F., Nabavi, M., & Sawan, M. (2020) · Sensors · doi:10.3390/s20030904 · Cited by 66 · see citing works
Design of high gain, high bandwidth neural amplifier IC considering noise-power trade-off
Laskar, N. M., Guha, K., Nath, S., Chanda, S., Baishnab, K. L., Paul, P. K., & Rao, K. S. (2018) · Microsystem Technologies · doi:10.1007/s00542-018-4142-5 · Cited by 33 · see citing works
Low power DDA-based instrumentation amplifier for neural recording applications in 65 nm CMOS
Avoli, M., Centurelli, F., Monsurrò, P., Scotti, G., & Trifiletti, A. (2018) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2018.05.014 · Cited by 30 · see citing works
System-Level Design of a 64-Channel Low Power Neural Spike Recording Sensor
Delgado‐Restituto, M., Rodríguez‐Pérez, A., Darie, A., Soto‐Sánchez, C., Fernandez-Jover, E., & Rodriguez-Vazquez, A. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2618319 · Cited by 30 · see citing works
Self-citationIn Vivo Penetrating Microelectrodes for Brain Electrophysiology
Erofeev, A., Antifeev, I., Bolshakova, A. V., Борисович, Б. И., & Власова, О. Л. (2022) · Sensors · doi:10.3390/s22239085 · Cited by 24 · see citing works
Passive Impedance Matching for Implanted Brain–Electrode Interfaces
Chen, W.-C., Guido, K., & Kiourti, A. (2019) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2019.2904024 · Cited by 21 · see citing works
Survey on various architectures of preamplifiers for electroencephalogram (EEG) signal acquisition
Devi, S., Guha, K., Baishnab, K. L., Iannacci, J., & Narayan, K. S. (2022) · Microsystem Technologies · doi:10.1007/s00542-022-05253-4 · Cited by 12 · see citing works
Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11 · see citing works
“A common element of integrated recording systems is an operational transconductance amplifier (OTA), used as the active amplifying element and can be implemented using a variety of techniques [157], [167].”
Distributed switched-resistor approach for high-Q biquad filters
Centurelli, F., Fava, A., Scotti, G., & Trifiletti, A. (2021) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2021.153894 · Cited by 8 · see citing works
Design of low noise amplifier for sensor applications
Jana, D., & Mal, A. K. (2017) · Devices for Integrated Circuit (DevIC) · doi:10.1109/devic.2017.8073990 · Cited by 5 · see citing works
Abdelgaliel, B. H., Exalto, M., Ou-Yang, Y.-H., & Muratore, D. G. (2024) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas61083.2024.10798201 · Cited by 4 · see citing works
A Novel Approach for the Design of Fast-Settling Amplifiers for Biosignal Detection
Rivas, E. A., Scandurra, G., Ciofi, C., García, C. R.-M., & Giannetti, R. (2021) · Electronics · doi:10.3390/electronics10212631 · Cited by 4 · see citing works
Devi, S., Guha, K., Jaksic, O. M., Baishnab, K. L., & Jakšić, Z. (2022) · Micromachines · doi:10.3390/mi13071104 · Cited by 3 · see citing works
A Review on Neural Amplifier Design for Brain–Machine Interface
Nath, S., Guha, K., & Baishnab, K. L. (2023) · Lecture notes in electrical engineering · doi:10.1007/978-981-99-4495-8_28 · Cited by 3 · see citing works
Nath, S., Kumar, N., Guha, K., Baishnab, K. L., & Rao, K. S. (2024) · Microsystem Technologies · doi:10.1007/s00542-023-05588-6 · Cited by 2 · see citing works
An 86 DB Gain 18.06 mVrms Input-Referred Noise LNA for Bio-Medical Applications
Kumar, G. R., Sunanda, K. N., & Prakash, M. D. (2020) · Lecture notes in electrical engineering · doi:10.1007/978-981-15-5546-6_67 · Cited by 1 · see citing works
Rathore, S. P. (2019) · International Journal for Research in Applied Science and Engineering Technology · doi:10.22214/ijraset.2019.5508
Matching Considerations for Wireless, Batteryless Brain Implants to High Impedance Electrodes
Guido, K., & Kiourti, A. (2019) · Digest - IEEE Antennas and Propagation Society. International Symposium · doi:10.1109/apusncursinrsm.2019.8889159
Optimal Design of a Biomedical Amplifier for Minimum Offset Using a Modified ABC Algorithm
Laskar, N. M., Devi, S., Kumaravel, S., Hasan, M. N., Choudhury, S., & Pandey, A. (2024) · Springer tracts in nature-inspired computing · doi:10.1007/978-981-97-7344-2_7
Optimal Design of Biomedical Operational Amplifier Using Improved Golden Jackal Optimization
Laskar, N. M., Devi, S., Maurya, A., Mohanty, P., Verma, P., & Nath, S. (2025) · Lecture notes in electrical engineering · doi:10.1007/978-981-96-3758-4_24
Design of a noise efficient bio-amplifier using CCFVF OTA for neurological signal acquisition
Nath, S., Devi, S., Laskar, N. M., Guha, K., & Baishnab, K. L. (2025) · Microsystem Technologies · doi:10.1007/s00542-025-05932-y
Design of Low Noise Amplifier using NMOS CVF OTA for Neural Recording Applications
Singh, N., Laskar, N. M., Kumar, G., Dhanaji, T. H., & Singh, A. K. (2026) · International Conference on Next Generation Electronics (NELEX) · doi:10.1109/nelex69209.2026.11590824
Design and Analysis of Low-Power, Low-Noise OTA for Biomedical Application
Nath, S., Devi, S., Laskar, N. M., Guha, K., & Baishnab, K. L. (2026) · Lecture notes in electrical engineering · doi:10.1007/978-981-92-0217-1_63
- Authors
- Ruiz-Amaya, J., Rodriguez-Perez, A., & Delgado-Restituto, M.
- Affiliations
- Institute of Microelectronics of Seville, Avda. Americo Vespucio s/n, Sevilla 41092, Spain
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2015-09-30
- Volume
- 15
- Issue
- 10
- Pages
- 25313-25335
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC4634474
- OpenAlex
- W2108919718
- Cited by
- 23
- References
- 47
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 4 · 2023: 1 · 2022: 3 · 2021: 2 · 2020: 2 · 2019: 3 · 2018: 2 · 2017: 2
- FWCI
- 0.66
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (publishedVersion, cc-by-nc-nd)
- DIGITAL.CSIC (Spanish National Research Council (CSIC)) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Deposito de Investigacion Universidad de Sevilla (University of Seville) (submittedVersion, cc-by-nc-nd)
- Funders
- Ministerio de Economía y Competitividad (TEC2012-33634)
- FEDER Programme (2013-15)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Low-power high-performance VLSI design
- Keywords
- low noise amplifier, two-stage OTA, noise efficiency factor, input-referred noise, low-power analog front-end, 130 nm CMOS, in vivo neural recording
- MeSH terms
- Action Potentials, Amplifiers, Electronic, Brain Mapping, Equipment Design, Feedback, Neurons, Signal Processing, Computer-Assisted, Biosensing Techniques, Limit of Detection, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review