Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
RF wireless interface enables remotely-powered implantable devices. Current studies in wireless power transmission into biological tissue tend to operate below 10 MHz due to tissue absorption loss, which results in large receive antennas. This paper examines the range of frequencies that will optimize the tradeoff between received power and tissue absorption. It first models biological tissue as a dispersive dielectric in a homogeneous medium and performs full-wave analysis to show that the optimal frequency is above 1 GHz for small receive coil and typical transmit-receive separations. Then, it includes the air-tissue interface and models human body as a planarly layered medium. The optimal frequency is shown to remain in the GHz-range. Finally, electromagnetic simulations are performed to include the effect of load impedance and look at the matched power gain. The optimal frequency is in the GHz-range for mm-sized transmit antenna and shifts to the sub-GHz range for cm-sized transmit antenna. The multiple orders of magnitude increase in the operating frequency enables dramatic miniaturization of implantable devices.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Theoretical studies have shown that energy transfer implemented with these characteristics can be 2-3 orders of magnitude more efficient than near-field systems (23,26).”
From Wireless power transfer to deep-tissue microimplants (2014) · cites this paper as [26]
Citations
Cites
Greiner, W. (1998) · Theoretical Physics · doi:10.1007/978-1-4612-0587-6 · Cited by 6,657
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 4×
“1 The real part begins to vary 1 The parameters in [23] are for the 4-term Cole-Cole model which is a variant of the Debye relaxation model.”
BackgroundMethodInfluentialWaves and Fields in Inhomogenous Media
Chew, W. C. (1999) · doi:10.1109/9780470547052 · Cited by 3,986
Classical Electrodynamics, 3rd ed .
Jackson, J. D., & Fox, R. F. (1999) · American Journal of Physics · doi:10.1119/1.19136 · Cited by 3,073
Implanted Antennas Inside a Human Body: Simulations, Designs, and Characterizations
Kim, J., & Rahmat-Samii, Y. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.832018 · Cited by 757
Design of Implantable Microstrip Antenna for Communication With Medical Implants
Soontornpipit, P., Furse, C. M., & Chung, Y. C. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.831976 · Cited by 472
Geometric approach for coupling enhancement of magnetically coupled coils
Zierhofer, C. M., & Hochmair, E. S. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.503178 · Cited by 420
Design of radio-frequency powered coils for implant instruments
Ko, W. H., Liang, S. P., & Fung, C. D. F. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457921 · Cited by 374
A neuro-stimulus chip with telemetry unit for retinal prosthetic device
Liu, W., Vichienchom, K., Clements, M., DeMarco, S. C., Hughes, C., McGucken, E., Humayun, M. S., De Juan, E., Weiland, J. D., & Greenberg, R. (2000) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.871327 · Cited by 371
Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems
Baker, M. W., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.893180 · Cited by 317
Research works printed but not linked: 4
- donaldson, 1986, frequency-hopping in r.f. energy-transfer links, Electron Wireless World, 24
- galbraith, 1984, An implantable multichannel neural stimulator
- schuder, 1961, high-level electromagnetic energy transfer through a closed chest wall, IRE Int Conv Record, 9, 119
- 0, IE3D Version 12 2
Cited by
Items 201–300 of 469
3D small antenna for energy harvesting applications on implantable micro-devices
Anacleto, P., Mendes, P. M., Gultepe, E., & Gracias, D. H. (2012) · Loughborough Antennas & Propagation Conference (LAPC) · doi:10.1109/lapc.2012.6402975 · Cited by 13
“This key feature of implantable devices is made possible by battery-free, ultra low power designs [15-17] and energy harvesting techniques that together contribute for smaller size implants with extended operational life times.”
BackgroundSafe inductive power transmission to millimeter-sized implantable microelectronics devices
Ibrahim, A., & Kiani, M. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318487 · Cited by 14
A Millimeter-Wave In-Phase Gate-Boosting Rectifier
Wang, Y.-J., Liao, I.-N., Tsai, C.-H., & Pakasiri, C. (2014) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2014.2352211 · Cited by 13
“The criteria, properties, and relating proofs of the IPVM are also discussed.”
BackgroundA CMOS fully-integrated wireless power receiver for autonomous implanted devices
Cabrera, F. L., & de Sousa, F. R. (2014) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2014.6865408 · Cited by 12
“The theoretical work discussed in [7] suggest that the optimal frequency for powering implants is in the GHz scale, without considering that the frequency where occurs the maximum quality factor of an inductor depends on its size and on the number of turns.”
BackgroundFujii, Y., Takagi, H., Wang, J., Yokoyama, Y., Saito, K., Takeshita, N., & Ito, K. (2022) · IEEE Antennas and Propagation Magazine · doi:10.1109/map.2022.3162808 · Cited by 12
Physical Bounds on Implant Powering Efficiency Using Body-Conformal WPT Systems
Soares, Í. V., Gao, M., Skrivervik, A. K., Šipuš, Z., Zhadobov, M., Sauleau, R., & Nikolayev, D. (2021) · IEEE Wireless Power Transfer Conference · doi:10.1109/wptc51349.2021.9458026 · Cited by 12
“The planar stratified model proposed in [9], [10], and various finite models were investigated by a spherical wave expansion in [11], [12] and by a full-wave approaches in [13].”
Le-Huu, H., & Seo, C. (2023) · IEEE Access · doi:10.1109/access.2023.3257343 · Cited by 12
“permittivity (εr ) and conductivity (σ ) [10].”
BackgroundA mm-sized implantable power receiver with adaptive matching
O’Driscoll, S. (2010) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2010.5690840 · Cited by 12
“Including this model for permittivity in the full-wave electromagnetic analysis of the link we derive the link efficiency from a transmitter, modeled by a magnetic current density, in free space to an area constrained receiver, modeled by a magnetic dipole of area Ar, in tissue dielectric and loaded by impedance ZL as…”
MethodSelf-citationAnalytical Model for Calculating Gain Pattern of Antennas Implanted in Large Host Bodies
Gao, M., Šipuš, Z., Soares, Í. V., Raman, S., Nikolayev, D., & Skrivervik, A. K. (2024) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2024.3392475 · Cited by 11
“By employing these simplified models, such as spherical, cylindrical, or planar body models, the EM radiation process is analyzed to obtain design strategies or benchmarks for realistic implanted antennas.”
MethodChallenges of ambient WiFi backscatter systems in healthcare applications
Lu, X., Yang, Y., & Gong, W. (2024) · Computer Networks · doi:10.1016/j.comnet.2024.110608 · Cited by 13
A New Efficient Dual-Band Circularly Polarized Implantable Patch Antenna for Wireless Power Transfer
Júnior, J. G. D., D’Assunção, A. G., & Neto, V. P. D. S. (2024) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2024.3488575 · Cited by 12
Rules of Thumb to Assess Losses of Implanted Antennas
Gao, M., Nikolayev, D., Bosiljevac, M., Šipuš, Z., & Skrivervik, A. K. (2021) · European Conference on Antennas and Propagation · doi:10.23919/eucap51087.2021.9411344 · Cited by 11
“[10] showed that the optimal frequency can be achieved at GHz-range for an inbody device operating in the midfield region.”
BackgroundEfficiency-Enhanced Wireless Power Transfer Based on Multiple Coupling Paths
Li, J., Lin, J.-K., Song, X., Yan, S., Xu, K., & Zhang, X. Y. (2021) · IEEE Microwave and Wireless Components Letters · doi:10.1109/lmwc.2021.3133259 · Cited by 12
High Gain Antenna Miniaturization With Parasitic Lens
Dang, D. N., & Seo, C. (2020) · IEEE Access · doi:10.1109/access.2020.3008234 · Cited by 11
“Consequently, the resonances of the source in simulation and measurement are 5.9 GHz and 5.95 GHz, respectively.”
BackgroundInfluentialBatteryless, Miniaturized Implantable Glucose Sensor Using a Fluorescent Hydrogel
Lee, H., Lee, J., Park, H., Nam, M. S., Heo, Y. J., & Kim, S. (2021) · Sensors · doi:10.3390/s21248464 · Cited by 12
“Since the operation frequency of a few GHz range is known to yield the highest power transfer efficiency for a millimeter-scale device [20], we operated the device at 1.”
MethodRecent Advances in Wireless Optoelectronic Biomedical Implants
Metuh, P., Petersen, P. M., & Ou, Y. (2024) · Laser & Photonics Review · doi:10.1002/lpor.202300752 · Cited by 13
Soares, Í., Šipuš, Z., Skrivervik, A., Sauleau, R., Alú, A., Ho, J. S., Nikolayev, D., & Kiourti, A. (2025) · IEEE Antennas & Propagation Magazine · doi:10.1109/map.2024.3482974 · Cited by 10
“For instance, semianalytical models based on planar [30], [71], [72] or spherical wave expansion [73], [74], although simplifications of the real problem, can provide physical insight into the energy exchange mechanism without requiring computationally costly full-wave simulations.”
A low-cost 2.45-GHz wireless power link for biomedical devices
Hu, S., Cheong, J. H., Gao, Y., Ho, M. C. K., Je, M., Madihian, M., & Khait, S. (2012) · IEEE Asia-Pacific Conference on Antennas and Propagation · doi:10.1109/apcap.2012.6333223 · Cited by 10
“Recently, this “old” topic becomes very promising [2] and attracts worldwide researchers and engineers, mainly driven by the “new” applications including biomedical devices [3][4], wireless powered vehicles/portable devices/RFID tags [5], noncontact wafer-level testing [6], and other batteryless systems.”
BackgroundFolded Spiral Resonator with Double-Layered Structure for Near-Field Wireless Power Transfer
Arai, T., & Hirayama, H. (2020) · Energies · doi:10.3390/en13071581 · Cited by 10
Andersen, E., Casados, C., Truong, B. D., & Roundy, S. (2021) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2021.3104787 · Cited by 10
“human tissue which further reduces efficiency [15].”
Amin, B., Rehman, M. R. U., Farooq, M., Elahi, A., Donaghey, K., Wijns, W. C., Shahzad, A., & Vazquez, P. (2023) · Sensors · doi:10.3390/s23073411 · Cited by 11
“In [21], the ideal frequency for efficient RF power transfer through multiple layers of biological tissues was examined.”
BackgroundGao, M., Rosenthal, J., Wu, K., Ramírez, G. A., Šipuš, Z., Lacour, S. P., & Skrivervik, A. K. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3300649 · Cited by 10
“A series of studies have been conducted with the help of simplified models, known as canonical body models, to analyze the fundamental limits and optimal radiation of body-implanted antennas [27], [28], [29], [30], [31], [32], [33], [34], [35], [36], [37].”
BackgroundYoon, I., & Ling, H. (2012) · InTech eBooks · doi:10.5772/28897 · Cited by 12
“…RFID (Fotopoulou & Flynn, 2007; Fotopoulou & Flynn, 2011; Sample & Smith, 2009; Bolomey et al., 2010; Yates et al., 2004), biomedical implants (Poon et al., 2010; RamRakhyani et al., 2011; Smith et al., 2007; Fotopoulou & Flynn, 2006), and electric car charging (Eom & Arai, 2009; Imura et…”
BackgroundEffects of Wireless Power Transfer on Capacitive Coupling Human Body Communication
Zhang, R., Liu, H., Shao, Q., Li, G., Fang, X., & Li, H. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2345254 · Cited by 10
“Currently, there is certain overlap between the frequency band of HBC and WPT that the former typically operates within the frequency range from 100 kHz to 100 MHz [20], while the latter is generally implemented in the frequency range of several kilohertz to several megahertz [21] due to tissue absorption loss and hum…”
BackgroundKhalili, H. F., Kirchner, J., Bartunik, M., Werner, S., Ebel, N., Schubert, D. W., Weyand, M., & Fischer, G. (2021) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2021.3119235 · Cited by 12
Energy transfer performance of mechanical nanoresonators coupled with electromagnetic fields
Javaheri, H., Barbiellini, B., & Noubir, G. (2012) · Nanoscale Research Letters · doi:10.1186/1556-276x-7-572 · Cited by 10
Investigation of on-chip coil in 130 nm standard CMOS for WPT and bio-applications
Kovac, M., Stopjaková, V., Arbet, D., Nagy, L., & Brenkuŝ, J. (2016) · International Conference on Emerging eLearning Technologies and Applications (ICETA) · doi:10.1109/iceta.2016.7802071 · Cited by 10
“of an optimal operating frequency for 1-2 cm implant depth [17], [18].”
BackgroundAnalytic Approximation of Free-Space Path Loss for Implanted Antennas
Gao, M., Raman, S., Šipuš, Z., & Skrivervik, A. K. (2024) · IEEE Open Journal of Antennas and Propagation · doi:10.1109/ojap.2024.3421923 · Cited by 9
“…antennas, analytical analysis of simplified body models offers a macroscopic perspective to investigate the electromagnetic (EM) radiation [19], [20] and wireless power transmission [21] characteristics of implants, with a special focus on near-field losses for different encapsulations [22], [23].”
Physical insights and design principles for efficient wireless implantable bioelectronics
Gao, M., Nikolayev, D., Šipuš, Z., & Skrivervik, A. K. (2025) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2025.102627 · Cited by 10
Optimizations of source distribution in wireless power transmission for implantable devices
Kim, S., & Poon, A. S. Y. (2010) · Digest - IEEE Antennas and Propagation Society. International Symposium · doi:10.1109/aps.2010.5562144 · Cited by 9
Self-citationManoufali, M., Naqvi, S. A. R., & Abbosh, A. M. (2018) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2018.2809621 · Cited by 10
“[6] showed that for millimeter(mm)-size implantable coil antennas, the optimum frequency for WPT operates at the order of 100s of MHz to around 1 GHz depending on the size of the exterior coil antenna.”
BackgroundAn Efficient Wireless Power Transfer for Retinal Prosthesis using Artificial Intelligent Algorithm
Ha‐Van, N., Vu, T. L., & Le, M. T. (2021) · European Microwave Conference (EuMC) · doi:10.23919/eumc48046.2021.9338235 · Cited by 10
“Beside the WPT technologies such as an inductive coupling system for very short distances of a few millimeters [5], [6], an electromagnetic wave system with the huge absorption rate in the human body [7], [8], a magnetic resonance WPT system is one of the most popular techniques for the implantable biomedical system […”
MethodMicrowave power penetration enhancement inside an inhomogeneous human head
Rokunuzzaman, M., Ahmed, A., Baum, T. C., & Rowe, W. S. T. (2021) · Scientific Reports · doi:10.1038/s41598-021-01293-4 · Cited by 9
Biological Effects of Environmental Electromagnetic Fields
Li, G., & Pang, X. F. (2011) · Advanced materials research · doi:10.4028/www.scientific.net/amr.183-185.532 · Cited by 9
Olivo, J., Carrara, S., & Micheli, G. D. (2010) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2010.5690847 · Cited by 11
“Recent works based on fullwave analysis [9,10] have questioned this assumption by showing that the penetration depth of the electromagnetic fields into the human body is asymptotically independent of the frequency.”
BackgroundNukala, B. T., Tsay, J., Lie, D. Y. C., López, J., & Nguyen, T. Q. (2016) · IEEE Texas Symposium on Wireless and Microwave Circuits and Systems (WMCS) · doi:10.1109/wmcas.2016.7577481 · Cited by 9
Modeling and Characterization of in-Body Antennas
Nikolayev, D. (2018) · International Conference on Mathematical Methods in Electromagnetic Theory · doi:10.1109/mmet.2018.8460279 · Cited by 9
“In addition to the aforementioned mechanisms, the radiation efficiency depends on the operating frequency, antenna position and depth in a body, arrangement of surrounding tissues, and polarization [17].”
BackgroundFeasibility Study of a Wireless Power Transfer System Applied to a Left Ventricular Assist Device
Campi, T., Cruciani, S., Orlando, F., Maradei, F., & Feliziani, M. (2019) · IEEE Wireless Power Transfer Conference · doi:10.1109/wptc45513.2019.9055691 · Cited by 8
“) is well known in literature [5]-[7], but there are only few studies for possible WPT application to an LVAD.”
BackgroundAn ultra-low-power monitoring system for inductively coupled biomedical implants
Keikhosravy, K., Kamalinejad, P., Mirabbasi, S., Takahata, K., & Leung, V. C. M. (2013) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2013.6572333 · Cited by 8
“Recent studies reveal that there is an optimum frequency for which the highest transmission efficiency can be obtained [2], [4].”
BackgroundPerryman, L. T., Larson, P. J., Glaser, J., & Consultant of Glaser Associates, L. A. (2016) · International Journal of Nano Studies & Technology · doi:10.19070/2167-8685-si02001 · Cited by 8
Comparison of Passive 2-D and 3-D Ring Arrays for Medical Telemetry Focusing
Bernety, H. M., Puckett, R. D., Schurig, D., & Furse, C. M. (2019) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2019.2911928 · Cited by 8
Wireless power transfer using multiple-transmitters for high stability for position
Onishi, K., Yamaguchi, K., & Iida, K. (2020) · International Journal of Electrical and Computer Engineering (IJECE) · doi:10.11591/ijece.v10i3.pp2245-2249 · Cited by 8
“INTRODUCTION 1Wireless power transfer (WPT) has been studied in various fields such as industry [1, 2], manufacturing [3], medicine [4, 5], and information [6, 7].”
Wireless Power Transmission: A survey
Pudur, R., Hanumante, V., Shukla, S., & Kumar, K. (2014) · IEEE International Conference on Recent Advances and Innovations in Engineering (ICRAIE) · doi:10.1109/icraie.2014.6909283 · Cited by 8
Optimal Frequencies for Wireless Power Transfer Through Biological Tissues
Ha‐Van, N., Tretyakov, S., & Simovski, C. R. (2025) · IEEE Open Journal of Antennas and Propagation · doi:10.1109/ojap.2025.3526414 · Cited by 8
“Transfer of power to devices in underground or underwater systems, and in-vivo medical devices faces challenges of high electromagnetic losses in the medium, resulting in limited battery lifetime [4], [5], [6].”
Challenges and Future Perspectives of Low-Power VLSI Circuits for Biomedical Applications: A Review
Jayaraman, S., Anithamary, M., Murugesh, K., & Dinesh, K. (2025) · IGI Global eBooks · doi:10.4018/979-8-3693-8084-0.ch011 · Cited by 10
Subwavelength-Scale Focused Wireless Powering of Implantable Medical Devices by Superoscillations
Abdolrazzaghi, M., Genov, R., & Eleftheriades, G. V. (2025) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2025.3568486 · Cited by 11
“Operating in the mid-field region—where the wavelength is comparable to the transmitter-RX separation—can enhance e ffi ciency by approximately 100 × [21].”
Research advances on a powering approach aimed toward electric nodes around the body region
Guo, Y., Zhang, S., Wu, C., Gong, Z., Zhang, Z., Zhang, Y., Park, J. H., Zhou, X., Guo, T., & Kim, T. W. (2023) · Nano Energy · doi:10.1016/j.nanoen.2023.109232 · Cited by 7
Experimental Study of In-Body Devices Misalignment Impact on Light-Based In-Body Communications
Fuada, S., Särestöniemi, M., Katz, M. D., Soderi, S., & Hämäläinen, M. (2024) · Communications in computer and information science · doi:10.1007/978-3-031-59091-7_30 · Cited by 9
Single-wire RF transmission lines for implanted devices
Besnoff, J. S., & Reynolds, M. S. (2013) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2013.6679679 · Cited by 7
“Magnetically coupled systems often have a modest implantation depth, on the order of centimeters, in part due to the tradeoff between antenna coil diameter and the depth at which good coupling efficiency can be achieved, given a particular operating frequency [5], [6].”
BackgroundAn optimal operating frequency selection scheme for maximizing inductive power link efficiency
Cheng, Y., Xuan, D., Su, X., Wu, W., & Wang, G. (2018) · Microwave and Optical Technology Letters · doi:10.1002/mop.31016 · Cited by 7
“[7] Sievenpiper DF, Dawson DC, Jacob MM, et al.”
BackgroundAntenna Array for Wireless Power Transfer to Deep-Brain Implants
Abdolrazzaghi, M., Genov, R., & Eleftheriades, G. V. (2022) · Digest - IEEE Antennas and Propagation Society. International Symposium · doi:10.1109/ap-s/usnc-ursi47032.2022.9887090 · Cited by 7
“In contrast, computational studies have demonstrated that the low-GHz regime can overcome these challenges (δ ∝ O(1)) [3] wherein both evanescent and propagating waves contribute to the power transfer to a load through diffraction effects in the tissue.”
BackgroundWearable Directional Button Antenna for On-Body Wireless Power Transfer
Xu, Y., Mu, L., Xu, Y., Mahmoud, A., Wang, Y., & Ramahi, O. M. (2023) · Electronics · doi:10.3390/electronics12081758 · Cited by 7
Micro antennas for implantable medical devices
Anacleto, P., Mendes, P. M., Gultepe, E., & Gracias, D. H. (2013) · IEEE Portuguese Meeting on Bioengineering · doi:10.1109/enbeng.2013.6518405 · Cited by 7
“Works on optimal frequency for energy harvesting have been presented [12][17], showing that a frequencies in the low gigahertz range are more suitable such applications.”
Wireless Charging Device for Artificial Cardiac Pacemaker
Xiong, Q. (2015) · International Conference on Information Technology and Management Innovation (ICITMI) · doi:10.2991/icitmi-15.2015.127 · Cited by 7
“Currently, the study of wireless power transfer in implantable device concentrates on coil optimization design [2-4], frequency optimization selection [5-7], and circuit design [8-10] and so on.”
BackgroundInductive power transmission to millimeter-sized biomedical implants using printed spiral coils
Ibrahim, A., & Kiani, M. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591801 · Cited by 8
“The optimal fp of low-GHz range has been proposed in [6] to deliver power to a wire-wound coil (WWC) with Do2 of 2 mm.”
BackgroundLe-Huu, H., & Seo, C. (2022) · 2022 Wireless Power Week (WPW) · doi:10.1109/wpw54272.2022.9853980 · Cited by 6
Electromagnetic field focusing for short-range wireless power transmission
Poon, A. S. Y. (2012) · IEEE Radio and Wireless Symposium (RWS) · doi:10.1109/rws.2012.6175400 · Cited by 6
Self-citationWireless powering of biomedical device via magnetic resonance
Jonah, O., & Georgakopoulos, S. V. (2012) · The ... IEEE Annual Wireless and Microwave Technology Conference · doi:10.1109/wamicon.2012.6208446 · Cited by 6
“For electromagnetic radiation method, energy transfer exhibits wave-like behavior through space, and full wave analysis is provided in [21] to identify the GHz-range is the optimal frequency for power transmission in biological media at the depth of 2 cm, and the PIFA working at 2.”
MethodFeasibility Study of a Wireless Power Transfer System Applied to a Leadless Pacemaker
Campi, T., Cruciani, S., Santis, V. D., Maradei, F., & Feliziani, M. (2018) · IEEE Wireless Power Transfer Conference · doi:10.1109/wpt.2018.8639120 · Cited by 6
Murphy, O. H., Borghi, A., Bahmanyar, M. R., McLeod, C. N., Navaratnarajah, M., Yacoub, M. H., & Toumazou, C. (2014) · Healthcare Technology Letters · doi:10.1049/htl.2014.0066 · Cited by 8
“Planar electromagnetic (EM) waves are used at higher frequencies for deeper implants, but the tissue induced losses are significant [14].”
BackgroundTalaat, M., Metwally, H. M. B., & Arafa, I. T. (2018) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2018.2847763 · Cited by 6
“affected by the exposed interference with other medical devices [12], [13].”
BackgroundInvestigation of inductive and radiating energy harvesting for an implanted biotelemetry antenna
Luu, Q.-T., Koulouridis, S., Diet, A. M., Bihan, Y. L., & Pichon, L. (2017) · European Conference on Antennas and Propagation · doi:10.23919/eucap.2017.7928620 · Cited by 6
“From [4]-[5] it is also indicated that the use of subGHz region is the optimum for inductive coupling in realistic scenarios.”
BackgroundInfluentialPower Transfer Efficiency Analyzed using Characteristic Mode Coupling Between Two Parallel Loops
Abderrazak, F., Antonino‐Daviu, E., & Ferrando‐Bataller, M. (2020) · European Conference on Antennas and Propagation · doi:10.23919/eucap48036.2020.9135229 · Cited by 6
“In order to observe the effect of coupling on modes in the frequency range from 1 to 4 GHz, the separation distance between two identical coplanar loop antennas sharing the same dimensions is varied.”
BackgroundInfluentialWireless powering and bidirectional telemetry front-end for implantable biomedical devices
Xue, R.-F., Cha, H., Cheong, J. H., Khannur, P. B., Je, M., & Zheng, Y. (2011) · International Symposium on Integrated Circuits · doi:10.1109/isicir.2011.6131898 · Cited by 6
“As for the overall efficiency of the wireless powering frontend, it is utmost important how efficiently the RF energy is coupled from the external device as well as how efficiently the power management blocks function, both of which should be designed elaborately.”
BackgroundLie, D. Y. C. (2017) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2017.02.00019 · Cited by 6
“Therefore, we conclude a well-designed 4-coil SCMR system should outperform the corresponding 2-coil system by successfully transferring about four times more power wirelessly into the tiny RX on-chip coil, which is about 330 times smaller in area than the previously reported smallest RX coil [12,13] for WPT using ind…”
BackgroundMethodInfluentialAutomatic Early-Onset Free Flap Failure Detection for Implantable Biomedical Devices
Rothfuss, M. A., Franconi, N. G., Star, A., Akçakaya, M., Gimbel, M. L., & Sejdić, E. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2793763 · Cited by 6
Antennas and Wireless Power Transfer for Brain‐Implantable Sensors
Ukkonen, L., Sydanheimo, L. T., Björninen, T., & Ma, S. (2021) · Wiley eBooks · doi:10.1002/9781119683285.ch4 · Cited by 7
Shaw, T., Mandal, B., Engstrand, J., Karlsson, R., Voigt, T., & Augustine, R. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3544346 · Cited by 5
“Typically, higher frequencies are unsuitable for IBC due to the lossy nature of biological tissues [17], [18].”
Fuada, S., Särestöniemi, M., & Katz, M. D. (2025) · Results in Optics · doi:10.1016/j.rio.2025.100801 · Cited by 7
Im, C., Kang, E., & Choo, H. (2024) · Journal of electromagnetic engineering and science · doi:10.26866/jees.2024.4.r.241 · Cited by 5
Annayev, M., Yamaner, F. Y., & Oralkan, Ö. (2025) · Microsystems & Nanoengineering · doi:10.1038/s41378-025-00902-w · Cited by 7
“Electromagnetic coupling is based on the principle of electromagnetic radiation 13,14 .”
A compact and low-power wireless receiver for implanted medical backscatter
Huo, D., Mao, L., Xie, S., & Liu, X. (2019) · IEICE Electronics Express · doi:10.1587/elex.16.20190501 · Cited by 5
“1 Operating frequency and sensitivity requirement As demonstrated in [7] and [19], the optimal frequency for wireless power transfer is in the GHz-range for mm-sized antennas.”
BackgroundA Systematic Design Method for a Wireless Power Transfer System Based on Filter Theory
Peng, C., Chen, Z. D., Xu, Z., Zhao, Z., Li, J., & Zhao, H. (2022) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2021.3138747 · Cited by 5
“the adverse effects of the distance changes and misalignments, such as frequency tracking [11]–[14], adaptive matching net-”
BackgroundOn the Maximum Power Density of Implanted Antennas within Simplified Body Phantoms
Gao, M., Šipuš, Z., & Skrivervik, A. K. (2022) · European Conference on Antennas and Propagation · doi:10.23919/eucap53622.2022.9768927 · Cited by 5
Song, S., Kim, M., & Park, S. (2022) · Electronics · doi:10.3390/electronics11223659 · Cited by 6
Characterization of chip-size electrically-small antennas for smart wireless biomedical devices
Dinis, H., Anacleto, P., Fernandes, J., & Mendes, P. M. (2015) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 5
Javaheri, H., Barbiellini, B., & Noubir, G. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090529 · Cited by 5
“However, most previous work investigates mechanisms operating in vacuum and relying on the effects of electrical fields [9], [13], [10].”
BackgroundEvaluation and optimization of high frequency wireless power links
Jegadeesan, R., & Guo, Y. (2011) · doi:10.1109/aps.2011.5996728 · Cited by 5
“However all of these power transfer methods use a lower frequency (< 20 MHz) of operation until recently when [4-5] proposed the use of high frequency (sub-GHz to GHz) for inductive power links in biomedical implants.”
BackgroundFULL-WAVE SEMI-ANALYTICAL MODELING OF PLANAR SPIRAL INDUCTORS IN LAYERED MEDIA
Li, Y.-L., & Sun, S. (2014) · Electromagnetic waves · doi:10.2528/pier14072404 · Cited by 5
“In [11, 14], the vertical magnetic dipole (VMD) model [15] was applied to describe a WPT system with two concentric loops.”
InfluentialCoil misalignment compensation techniques for wireless power transfer links in biomedical implants
Kong, F. (2015) · doi:10.7282/t3wh2s0m · Cited by 5
Inductive power transmission, charging and communication for implantable devices
Chandima, D. P., Dayarathna, K. D. U. I., Jayasinghe, H., Dharmasiri, W. K. K. R., & Weerasinghe, H. M. (2017) · IEEE International Conference on Industrial and Information Systems (ICIIS) · doi:10.1109/iciinfs.2017.8300356 · Cited by 5
“frequency should be below 10 MHz due to tissue absorption loss [5].”
BackgroundMishra, A., & Agrawal, D. P. (2019) · Journal of Sensor and Actuator Networks · doi:10.3390/jsan8040054 · Cited by 5
“[37] shows that for small transmitter–receiver separations across the air–tissue interface, the optimum frequency is in the GHz range indicating that higher channels in WirelessHART can still be used in an HSN.”
BackgroundEffect of Misaligned Relay on Output Power and Efficiency in Wireless Power Transfer
Lee, K., & Lee, W. (2021) · IEEE Access · doi:10.1109/access.2021.3069131 · Cited by 5
“Inspired by early research, there have been many attempts to investigate such characteristics as operating frequency [3], [4], mutual coupling [5], [6], and frequency splitting [7]–[9] in WPT.”
BackgroundAntenna operating frequency selection for energy harvesting on nano biomedical devices
Gracias, D. H., Gultepe, E., Anacleto, P., Correia, J. H., & Mendes, P. M. (2011) · European Microwave Conference (EuMC) · doi:10.23919/eumc.2011.6101969 · Cited by 5
“However, since human body tissue attenuation increases with frequency [1], it is challenging to obtain an efficient link.”
BackgroundAn in-body wireless communication system for targeted drug delivery: Design and simulation
Ramesh, M. V., Mohan, K. S. K. C. L., & Dilraj, N. (2014) · International Symposium on Technology Management and Emerging Technologies (ISTMET) · doi:10.1109/istmet.2014.6936477 · Cited by 5
Integrated CMOS wireless power transfer for neural implants
Zargham, M., & Gulak, P. G. (2011) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2011.6107753 · Cited by 5
“Question: Is there an optimum frequency for WPT through tissue? In references [6], [9] the authors state that the optimum frequency for powering a typical set of miniature coils, mmsized, through tissue is in the Giga-Hertz range, and that this frequency drops to a couple of hundred MHz for the case where one of the c…”
BackgroundCheong, Y. J., Ramiah, H., Lian, W. X., Lee, Y. C., Churchill, K. K. P., & Chen, Y. (2025) · IEEE Access · doi:10.1109/access.2025.3632861 · Cited by 6
“To safely transmit power to the RFEH-powered BSN devices, the RF transmitted power is recommended within sub-mW to mW for carrier frequencies more than GHz [114], [115], while tens of mW for carrier frequencies ranging in MHz level [113], [116].”
Optimal Frequency and Wireless Power Budget for Miniature Receivers in Obese People
de Steene, T. V., Tanghe, E., Martens, L., Garripoli, C., Stanzione, S., & Joseph, W. (2023) · Sensors · doi:10.3390/s23198084 · Cited by 4
“…focuses on the optimal efficiency for a depth of 20 cm. Interesting studies searching for the optimal frequency have been conducted already [40,49–52], although tissues are considered homogeneous, a far-field approximation is used, only tissue losses are considered for the efficiency, or the…”
BackgroundFaisal, F., Moulay, A., Chaker, M., & Djerafi, T. (2024) · European Conference on Antennas and Propagation · doi:10.23919/eucap60739.2024.10500918 · Cited by 4
“The midfield WPT concept and the related formula for calculating the optimal frequency for the mid-field WPT was first introduced in [9].”
BackgroundChen, B., Liu, X., Zhang, Z., & Wang, Y. (2025) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2025.3560341 · Cited by 5
“The high loss of human tissue results in low RF power input to the rectifier [18], which, in turn, reduces the e ffi ciency of the diodes [19].”
Avestruz, A.-T., Chang, A. H., & Leeb, S. B. (2015) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2015.7104836 · Cited by 4
“56 MHz [1]–[3], where device optimization along with RF exposure of humans are a concern, it is advantageous to use other frequencies [2], [21]–[23].”
BackgroundA robust wireless power transmission for charging low power consumption appliances
Palantei, E., Baharuddin, M., Tangkudung, R. R. S., & Sudirman, A. (2014) · Digest - IEEE Antennas and Propagation Society. International Symposium · doi:10.1109/aps.2014.6904546 · Cited by 4
Chang, C.-W., Hou, K.-C., Shieh, L.-J., Hung, S.-H., & Chiou, J. (2011) · IEEE International Nanoelectronics Conference · doi:10.1109/inec.2011.5991732 · Cited by 5
“Various approaches have been presented for inductive link optimization in implantable electronics [10–12].”
An RF-powered 58Mbps-TX 2.5Mbps-RX full-duplex transceiver for neural microimplants
Rajavi, Y., Taghivand, M., Aggarwal, K., Ma, A., & Poon, A. S. Y. (2016) · Digest of papers - IEEE Radio Frequency Integrated Circuits Symposium · doi:10.1109/rfic.2016.7508294 · Cited by 4
“Several applications such as brain-machine interface and retinal implants require data rates of tens of megabits per second, as the number of recorded channels increase [1], [2].”
BackgroundSelf-citationEnergy management integrated circuits for wireless power transmission
Lee, H., & Ghovanloo, M. (2015) · Elsevier eBooks · doi:10.1016/b978-0-323-26208-8.00005-4 · Cited by 5
Lyu, H., Wang, J., La, J., Chung, J. M., & Babakhani, A. (2018) · IEEE MTT-S International Microwave Symposium digest · doi:10.1109/mwsym.2018.8439143 · Cited by 4
“The resonant frequency is about 250 MHz.”
InfluentialMiozzi, C., Saggio, G., Gruppioni, E., & Marrocco, G. (2019) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2019.8771087 · Cited by 4
“The numerical analysis in [9], including the transmitting and receiving coils in a layered tissue model, revealed that the ratio between the received power and the total tissue absorption is maximized in the GHz band for mm-sized transmitting antenna and in sub-GHz band for the cm-sized one.”
BackgroundJoshi, A., Dash, J. C., & Sarkar, D. (2022) · European Conference on Antennas and Propagation · doi:10.23919/eucap53622.2022.9769618 · Cited by 3
A Systematic Design Method for Wireless Power Transfer Systems Using the High-Order Filter Theory
Peng, C., Chen, Z. D., Xu, X., Dong, J., Zhu, Y., & Yu, Y. (2023) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2023.3284260 · Cited by 4
“To ensure a stable and sufficient PTE, several methods were proposed; they include resonant frequency tracking [10], [11], [12], [13], adaptive impedance matching [14], [15], [16], use of metamaterials [17], [18], multisource methods [19], [20], and multicoil systems [21], [22].”
MethodWireless Power Harvesting During MRI
Venkateswaran, M., Kurpad, K. N., Brown, J. E., Fain, S. B., & van der Weide, D. W. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175648 · Cited by 4
“Also, to facilitate better artifact immunity a broadband system design (currently not a common clinical configuration) may allow choice of an optimal powering frequency that is distinct from that used for imaging [23].”
Background
Metadata
- Authors
- Poon, A. S. Y., O'Driscoll, S., & Meng, T. H.
- Affiliations
- Stanford University (US)
- ORCID
- Poon, Ada S Y
- Venue
- IEEE Transactions on Antennas and Propagation
- Published
- 2010-05
- Volume
- 58
- Issue
- 5
- Pages
- 1739-1750
- ISSN
- 0018-926X (ISSN-L)
- 1558-2221
- OpenAlex
- W2110545851
- Semantic Scholar
- e6a37dc9b793041a01befbefb870dde9882038d3
- Cited by
- 469
- References
- 25
- Citations by year
- 2026: 7 · 2025: 25 · 2024: 32 · 2023: 31 · 2022: 30 · 2021: 42 · 2020: 23 · 2019: 38 · 2018: 27 · 2017: 36 · 2016: 34 · 2015: 32 · 2014: 33 · 2013: 31 · 2012: 29
- FWCI
- 19.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Antennas and Propagation (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Energy Harvesting in Wireless Networks
- Keywords
- wireless power transfer, biomedical implants, optimal operating frequency, air-tissue interface, load impedance matching, RF power transmission
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.