Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
RF wireless interface enables remotely-powered implantable devices. Current studies in wireless power transmission into biological tissue tend to operate below 10 MHz due to tissue absorption loss, which results in large receive antennas. This paper examines the range of frequencies that will optimize the tradeoff between received power and tissue absorption. It first models biological tissue as a dispersive dielectric in a homogeneous medium and performs full-wave analysis to show that the optimal frequency is above 1 GHz for small receive coil and typical transmit-receive separations. Then, it includes the air-tissue interface and models human body as a planarly layered medium. The optimal frequency is shown to remain in the GHz-range. Finally, electromagnetic simulations are performed to include the effect of load impedance and look at the matched power gain. The optimal frequency is in the GHz-range for mm-sized transmit antenna and shifts to the sub-GHz range for cm-sized transmit antenna. The multiple orders of magnitude increase in the operating frequency enables dramatic miniaturization of implantable devices.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Theoretical studies have shown that energy transfer implemented with these characteristics can be 2-3 orders of magnitude more efficient than near-field systems (23,26).”
From Wireless power transfer to deep-tissue microimplants (2014) · cites this paper as [26]
Citations
Cites
Greiner, W. (1998) · Theoretical Physics · doi:10.1007/978-1-4612-0587-6 · Cited by 6,657
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 4×
“1 The real part begins to vary 1 The parameters in [23] are for the 4-term Cole-Cole model which is a variant of the Debye relaxation model.”
BackgroundMethodInfluentialWaves and Fields in Inhomogenous Media
Chew, W. C. (1999) · doi:10.1109/9780470547052 · Cited by 3,986
Classical Electrodynamics, 3rd ed .
Jackson, J. D., & Fox, R. F. (1999) · American Journal of Physics · doi:10.1119/1.19136 · Cited by 3,073
Implanted Antennas Inside a Human Body: Simulations, Designs, and Characterizations
Kim, J., & Rahmat-Samii, Y. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.832018 · Cited by 757
Design of Implantable Microstrip Antenna for Communication With Medical Implants
Soontornpipit, P., Furse, C. M., & Chung, Y. C. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.831976 · Cited by 472
Geometric approach for coupling enhancement of magnetically coupled coils
Zierhofer, C. M., & Hochmair, E. S. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.503178 · Cited by 420
Design of radio-frequency powered coils for implant instruments
Ko, W. H., Liang, S. P., & Fung, C. D. F. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457921 · Cited by 374
A neuro-stimulus chip with telemetry unit for retinal prosthetic device
Liu, W., Vichienchom, K., Clements, M., DeMarco, S. C., Hughes, C., McGucken, E., Humayun, M. S., De Juan, E., Weiland, J. D., & Greenberg, R. (2000) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.871327 · Cited by 371
Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems
Baker, M. W., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.893180 · Cited by 317
Research works printed but not linked: 4
- donaldson, 1986, frequency-hopping in r.f. energy-transfer links, Electron Wireless World, 24
- galbraith, 1984, An implantable multichannel neural stimulator
- schuder, 1961, high-level electromagnetic energy transfer through a closed chest wall, IRE Int Conv Record, 9, 119
- 0, IE3D Version 12 2
Cited by
Items 401–469 of 469
Electrical Properties Measurement of Rat Blood in 10 kHz-10 MHz
Li, G. (2013) · Advanced materials research · doi:10.4028/www.scientific.net/amr.774-776.836
“Blood shows nonlinear characteristics in the frequency domain, measurement of dielectric and conductive properties of biological tissue in frequency domain has always been a hot issue for research scholars [1-8], techniques and principles of testing electrical characteristics of biological tissue are similar with the…”
BackgroundProduce of Strong Pulse Electromagnetic Field and its Biological Effect
Li, G. (2014) · Advanced materials research · doi:10.4028/www.scientific.net/amr.933.216
“Electromagnetic environment which is an important factor, especially in recent years the development and progress of the medical industry, people have been increasingly aware of these environmental magnetic fields on the human body, but also can make use of an external magnetic field region of the lesion performed the…”
BackgroundStudy of displacement current effect for planar coils in layered medium
Li, Y., & Sun, S. (2014) · Digest - IEEE Antennas and Propagation Society. International Symposium · doi:10.1109/aps.2014.6904543
“Hz), which is consistent with the conclusion in [5].”
BackgroundMethodResultA HF-RFID, -19 dBm sensitivity fully integrated RF-DC voltage multiplier
Pasca, M., Catarinucci, L., Colella, R., Donno, D. D., Tarricone, L., & D'Amico, S. (2015) · Mediterranean Microwave Symposium · doi:10.1109/mms.2015.7375374
“In fact, the specific absorption rate (SAR) increases with frequency [11].”
BackgroundA study of methodology and technology for wireless monitoring of blood pressure inside a stent
Brox, D. (2015) · cIRcle (University of British Columbia) · doi:10.14288/1.0167345
Electromagnetic Energy and Data Transfer for a Neural Implant
(2013) · Journal of Ubiquitous Systems and Pervasive Networks · doi:10.5383/juspn.05.01.002
Inductive Power Transmission Systems
Kiani, M., & Ghovanloo, M. (2016) · Wiley eBooks · doi:10.1002/047134608x.w8306
A robust low quiescent current power receiver for inductive power transmission in bio implants
Helalian, H., Pasandi, G., & Ashtiani, S. J. (2016) · International Journal of Electronics · doi:10.1080/00207217.2016.1244863 · Cited by 1
Dual band electrically small non-uniform pitch ellipsoidal helix antenna for cardiac pacemakers
Huang, H., Chen, P., Mauro Ferrari, B., Hu, Y., & Akinwande, D. (2013) · IEEE Topical Conference on Wireless Sensors and Sensor Networks (WiSNeT) · doi:10.1109/wisnet.2013.6488654
Ultra-low energy electronics for synthetic biological sensors
Nadeau, P. (2016) · DSpace@MIT (Massachusetts Institute of Technology)
Jow, U.-M. (2013) · SMARTech Repository (Georgia Institute of Technology) · Cited by 1
A wireless power transfer route to magnetically mediated hyperthermia
Lang, H.-D., Xu, G., & Sarris, C. D. (2017) · European Conference on Antennas and Propagation · doi:10.23919/eucap.2017.7928729
“2) Optimal Operating Frequency: It has been shown that the optimal choice of operating frequency for WPT to implants (depending on their electrical sizes and implant depths) can lie in a much higher range than intuitively expected [25]: For device dimensions in the millimeters, a frequency in the range of hundreds of…”
BackgroundMethodInfluentialDual band electrically small non-uniform pitch ellipsoidal helix antenna for cardiac pacemakers
Huang, H., Chen, P., Mauro Ferrari, B., Hu, Y., & Akinwande, D. (2013) · IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS) · doi:10.1109/biowireless.2013.6613704
Power Link Optimization for a Neurostimulator in Nasal Cavity
Lee, S., Kim, J., & Kim, S. (2017) · International Journal of Antennas and Propagation · doi:10.1155/2017/9096217
“Specifically, for an implant with a size of few millimeters, the optimal frequency lies in the low gigahertz range [12].”
BackgroundMethodFull-Duplex Wireless-Powered Communications
Mohammadi, M., Chalise, B. K., & Suraweera, H. A. (2017) · Springer eBooks · doi:10.1007/978-3-319-56669-6_2
“In addition, characteristics of the propagation environment is an important factor for wireless power transmission and the received power level depends on the range of frequencies used [24].”
BackgroundIntegration of inductive energy harvesting in a biotelemetry implant
Koulouridis, S., Diet, A. M., Bihan, Y. L., & Pichon, L. (2017) · Digest - IEEE Antennas and Propagation Society. International Symposium · doi:10.1109/apusncursinrsm.2017.8072886
“As shown in [1] and [2] optimum frequency for such sizes is the sub-GHz region.”
BackgroundManoufali, M., & Abbosh, A. M. (2017) · Asia-Pacific Microwave Conference (APMC) · doi:10.1109/apmc.2017.8251509
“Externally powered IMDs necessitate EM fields exposure to avail power for the device operation [1], [2], [3], [4].”
BackgroundSkinnySensor: Enabling Battery-Less Wearable Sensors Via Intrabody Power Transfer
Kiran, N. (2021) · Scholarworks (University of Massachusetts Amherst) · doi:10.7275/12764526
RF power transmission and its considerations for ECoG implants
Ha, S., Kim, C., Mercier, P. P., & Cauwenberghs, G. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815115-0.00013-1
Introduction to ECoG interfaces
Ha, S., Kim, C., Mercier, P. P., & Cauwenberghs, G. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815115-0.00008-8
Power management for mm-sized ECoG implants
Ha, S., Kim, C., Mercier, P. P., & Cauwenberghs, G. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815115-0.00012-x
Wireless Transfer of Energy Alongside Information in Wireless Sensor Networks
Javaheri, H., & Noubir, G. (2019) · Studies in systems, decision and control · doi:10.1007/978-3-319-92384-0_13
Air-core Transcutaneous Transformers Embedded in a Biological Tissue:
SUNADA, S., & Shiba, K. (2019) · Journal of the Japan Society of Applied Electromagnetics and Mechanics · doi:10.14243/jsaem.27.315
Design and Development of a Wireless Lamp Charging System
Abiodun, E. A.-S. E. (2017)
Khalili, H. F., Kirchner, J., Bartunik, M., Werner, S., Ebel, N., Schubert, D. W., Weyand, M., & Fischer, G. (2021) · doi:10.36227/techrxiv.13561985.v1
“In [12], the optimal frequency, suitable for small-sized WPT in contact with a dispersive medium, is investigated.”
BackgroundAppendix A Antennas and Sensors for Medical Applications: A Representative Literature Review
Song, L., & Rahmat‐Samii, Y. (2021) · Wiley eBooks · doi:10.1002/9781119683285.app1
Islam, M. S., Kiourti, A., & Islam, M. A. (2021) · Sensors · doi:10.3390/s21206730
“At the resonant frequency of 4.8GHz, the system264 shows a transmission loss of −11.27dB in the simulation in HFSS (−10.50dB in the265 simulation in CST).”
BackgroundInfluentialDesign Techniques for Log Based Closed-Loop Neurostimulation System-On-Chip.
Rhew, H.-G. (2012) · Deep Blue (University of Michigan)
Technologies for Wireless Transcutaneous Transfer of Power to Implanted Devices
Vavilov, V. E., Заико, А. И., Азатовна, Н. Р., Петунин, В. И., & Николаевич, В. А. (2021) · International Conference on Electrotechnical Complexes and Systems (ICOECS) · doi:10.1109/icoecs52783.2021.9657226
Wireless Bioelectronic Interfaces Electromagnetic Performance and Safety
Kim, H., Dong, Z., & Ho, J. S. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_24-2
Alomrani, B., Javed, M., Ali, H. S. H. M., Abo‐Aba, S. E. M., AlBakheet, A., AlQudairy, H., & Kaya, N. (2022) · Journal of Contemporary Medical Sciences · doi:10.22317/jcms.v8i1.1167
Khalili, H. F., Kirchner, J., Bartunik, M., Werner, S., Ebel, N., Schubert, D. W., Weyand, M., & Fischer, G. (2021) · IEEE transactions on magnetics · doi:10.36227/techrxiv.13561985
“In [12], the optimal frequency, suitable for small-sized WPT in contact with a dispersive medium, is investigated.”
Design of mm-Sized Wirelessly Powered Sensors
Bolus, J. F. (2014) · doi:10.18130/v3xf9k
Wireless Implant Communications Using the Human Body
Teshome, A. K., Kibret, B., & Lai, D. T. H. (2018) · Advances in computer and electrical engineering book series · doi:10.4018/978-1-5225-7598-6.ch085
Freedman, D. S., Şahin, M., & Towe, B. C. (2015) · Springer eBooks · doi:10.1007/978-1-4614-6675-8_605
Freedman, D. S., Şahin, M., & Towe, B. C. (2013) · Springer eBooks · doi:10.1007/978-1-4614-7320-6_605-2
Wireless transfer of energy alongside information
Javaheri, H. (2012) · doi:10.17760/d20002886
Freedman, D. S., Şahin, M., & Towe, B. C. (2014) · Encyclopedia of Computational Neuroscience · doi:10.1007/978-1-4614-7320-6_605-3
Wasky, R. P. (2022) · IEEE Antennas and Propagation Magazine · doi:10.1109/map.2022.3162804
Amaya, J. P. (2015) · Louisiana State University · doi:10.31390/gradschool_theses.1990
State-of-the-Art Technology on Highly Miniaturized Free-Floating Neural Implants
Khalifa, A., & Etienne‐Cummings, R. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_114-1 · Cited by 1
Light Interaction With an Ensemble of Quantum Dots [Guest Editorial]
Chew, W. C., Boag, A., & Hanson, G. W. (2022) · IEEE Antennas and Propagation Magazine · doi:10.1109/map.2022.3198219
Joshi, A. C., Dash, J. C., & Sarkar, D. (2022) · doi:10.36227/techrxiv.21641654.v1 · Cited by 1
Development of Wireless Control Technique for Photodynamic Therapy In-Vivo Deep Tissue
An, J., Kim, S.-U., & Sa, G. (2023) · The Journal of Korean Institute of Information Technology · doi:10.14801/jkiit.2023.21.1.69
A Design Of Wideband Midfield Transmitter for Wireless Power Transfer To Biomedical Implants
Le-Huu, H., & Seo, C. (2023) · IEEE Wireless Power Technology Conference and Expo (WPTCE) · doi:10.1109/wptce56855.2023.10216013
High-Performance Radiative Near-Field Transmitter for Wireless Power Transfer to Biomedical Implants
Le-Huu, H., & Seo, C. (2023) · URSI General Assembly and Scientific Symposium · doi:10.23919/ursigass57860.2023.10265601
“However, the proposed Tx was excited on the antenna’s boundary, which cannot achieve the third condition of current distribution, as presented in [3].”
BackgroundOptimal Frequency for Biomedical Wireless Power TransferPreprint
van Nunen, T., Mestrom, R., & Visser, H. J. (2023) · Research Square · doi:10.21203/rs.3.rs-3527426/v1
Far‐field Wireless Power Transmission for Biomedical Application
Guo, Y., Feng, Y., & Liu, C. (2024) · doi:10.1002/9781119189947.ch8
Near‐field Wireless Power Transfer for Biomedical Applications
Guo, Y., Feng, Y., & Liu, C. (2024) · Wiley eBooks · doi:10.1002/9781119189947.ch7
Wireless Power Transfer with Silicon Steel Core and Copper Wire for Various MediumsPreprint
Somashekar, B., & Moger, G. D. (2024) · Research Square · doi:10.21203/rs.3.rs-4261450/v1
Fu, S., Song, L., Wang, Y., Wang, J., Su, D., & Rahmat‐Samii, Y. (2024) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2024.3486043
“Poon et al. [12] examined the range of frequencies that optimizes the tradeoff between received power and tissue absorption via theoretical analysis and full-wave simulations.”
Systems for power and data transfer
Qu, Y., Vilathgamuwa, D. M., McCormick, D., & McGiffin, D. C. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-22148-4.00022-8
Passive Acoustic Temperature Sensor Characterization with Animal Tissue
Maini, L., Furrer, R., Hierold, C., & Roman, C. I. (2024) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors60989.2024.10784938
“Acoustic waves are significantly less absorbed by tissue, leading to considerably lower power levels introduced in the body, and allowing a safer long-term and continuous interrogation [6], [7].”
Biswas, D. K. (2022) · University of North Texas Digital Library (University of North Texas) · doi:10.12794/metadc1944251
Shah, S. A. A. (2025) · Springer eBooks · doi:10.1007/978-981-96-2995-4_3
Design of Fat-Intra Body Power Transfer System for Implantable Biomedical Devices
Shaw, T., Mandal, B., & Augustine, R. (2025) · European Conference on Antennas and Propagation · doi:10.23919/eucap63536.2025.10999400
“However, it has been shown by Poon et al. that the better performance from implantable systems are attained in gigahertz and sub-gigahertz frequency domains [10].”
Saroglia, G., Marocco, S., Nicoloso, S., Diana, S., Tozzi, M., & Stefanini, I. (2025) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2025.100645 · Cited by 1
Marini, E., Coviello, A., & Magarini, M. (2025) · International Symposium on Medical Information and Communication Technology · doi:10.1109/ismict64722.2025.11059400
“Additionally, higher frequencies contribute to increased heating, as observed in [15].”
Wireless Power Transfer Through Biological Tissue: The Role of The Interface
Simovski, C., Nam, H.-V., & Tretyakov, S. (2025) · 2025 IEEE Wireless Power Technology Conference and Expo (WPTCE) · doi:10.1109/wptce62521.2025.11062190
“The authors of works [2], [4]–[6] targeting the capsule endoscopy and cardiac implants assumed the following reason why their optimal frequency range turned out to be so high.”
Ayaz, H., Khan, A. A., Khan, N., Hasnain, M., Mesbah, S., Ahmad, A., Ahmed, M. R., Ayaz, H., Ahmed, R., & Sana, A. (2025) · International Journal of Scientific Research and Modern Technology. · doi:10.38124/ijsrmt.v4i10.912 · Cited by 1
Compact WPT System Using Four Resonators for Biomedical Implants
Aboualalaa, M., & Pokharel, R. K. (2025) · European Microwave Conference (EuMC) · doi:10.23919/eumc65286.2025.11235013
“However, for compact WPT systems with minimal displacement current, sub-GHz frequencies offer greater efficiency [6], [10] – [12].”
Radiation Efficiency and In Vivo Link Model of Implantable Antennas in Lossy Media
Xiao, F., Li, Z. Z., & Plettemeier, D. (2026) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2026.3671375
“As reported in [27], the radiation e ffi ciency of electrically small magnetic antennas exceeds that of their electric counter-parts when operating in lossy biological media.”
Pasquier, A. (2022) · theses.fr (ABES) · doi:10.70675/73a1f28azf3f1z432ez9472z582eb450ff16 · Cited by 2
Adaptive wireless powering of miniature implantable bioelectronics
Soares, Í. V. (2023) · theses.fr (ABES) · doi:10.70675/b2b9ce81zb224z4d5fza9c5z5eab0befed54
Narayana, I. O. U., Elias, F., Ekpo, S., Ghosh, S., & Alabi, S. (2026) · Discover Electronics · doi:10.1007/s44291-026-00207-w
Hui, S. Y. R., Li, K., Yu, J., & Tan, S. C. (2026) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2026.3691097
“…Sengupta and Weisshaar [15], Chen et al. [16], Wang et al. [17], and Harris and Ricketts [18], published in subsequent years, point to the same complex nature of the mutual inductance highlighted in [8], [9], and [13] for WPT systems in the presence of conductive and magnetic slabs or metasurfaces.”
InfluentialA Wearable 3D-Printed Embroidered Antenna for Wireless Powering of Deep Medical Implants
Gawade, D. R., O'Callaghan, B., Liao, W., Elobied, A. A., Moloudian, G., Kumar, S., O’Flynn, B., O’Hare, D., & Buckley, J. L. (2026) · European Conference on Antennas and Propagation · doi:10.23919/eucap68105.2026.11612175
“The optimal frequency ( f opt ) for maximum WPT in the mid-field is derived in [2] and shown in Equation (1).”
A wearable-to-implant wireless power transfer technology with variation tolerance
Nam, S., Seo, T., Yoo, S., Park, C., Kim, T., Yu, M., Kim, Y., Kang, H., Yeom, D., Cho, Y., et al. (2026) · Nature Electronics · doi:10.1038/s41928-026-01714-0 · Cited by 2
“W input power, well within safety guidelines 59 (Supplementary Fig.”
Metadata
- Authors
- Poon, A. S. Y., O'Driscoll, S., & Meng, T. H.
- Affiliations
- Stanford University (US)
- ORCID
- Poon, Ada S Y
- Venue
- IEEE Transactions on Antennas and Propagation
- Published
- 2010-05
- Volume
- 58
- Issue
- 5
- Pages
- 1739-1750
- ISSN
- 0018-926X (ISSN-L)
- 1558-2221
- OpenAlex
- W2110545851
- Semantic Scholar
- e6a37dc9b793041a01befbefb870dde9882038d3
- Cited by
- 469
- References
- 25
- Citations by year
- 2026: 7 · 2025: 25 · 2024: 32 · 2023: 31 · 2022: 30 · 2021: 42 · 2020: 23 · 2019: 38 · 2018: 27 · 2017: 36 · 2016: 34 · 2015: 32 · 2014: 33 · 2013: 31 · 2012: 29
- FWCI
- 19.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Antennas and Propagation (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Energy Harvesting in Wireless Networks
- Keywords
- wireless power transfer, biomedical implants, optimal operating frequency, air-tissue interface, load impedance matching, RF power transmission
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.