Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems
Abstract
This paper presents a feedback-loop technique for analyzing and designing RF power links for transcutaneous bionic systems, i.e., between an external RF coil and an internal RF coil implanted inside the body. The feedback techniques shed geometric insight into link design and minimize algebraic manipulations. We demonstrate that when the loop transmission of the link's feedback loop is -1, the link is critically coupled, i.e., the magnitude of the voltage transfer function across the link is maximal. We also derive an optimal loading condition that maximizes the energy efficiency of the link and use it as a basis for our link design. We present an example of a bionic implant system designed for load power consumptions in the 1-10-mW range, a low-power regime not significantly explored in prior designs. Such low power levels add to the challenge of link efficiency, because the overhead associated with switching losses in power amplifiers at the link input and with rectifiers at the link output significantly degrade link efficiency. We describe a novel integrated Class-E power amplifier design that uses a simple control strategy to minimize such losses. At 10-mW load power consumption, we measure overall link efficiencies of 74% and 54% at 1- and 10-mm coil separations, respectively, in good agreement with our theoretical predictions of the link's efficiency. At 1-mW load power consumption, we measure link efficiencies of 67% and 51% at 1- and 10-mm coil separations, respectively, also in good accord with our theoretical predictions. In both cases, the link's rectified output dc voltage varied by less than 16% over link distances that ranged from 2 to 10 mm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feedback control of dynamic systems
Kahne, S. (1987) · Automatica · doi:10.1016/0005-1098(87)90017-3 · Cited by 3,450
Feedback Control of Dynamic Systems
Franklin, G. F., Powell, D. J., & Emami-Naeini, A. (1986) · Cited by 2,293
Class E-A new class of high-efficiency tuned single-ended switching power amplifiers
Sokal, N. O., & Sokal, A. D. (1975) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1975.1050582 · Cited by 2,033
Terman, F. E. (1943) · Virtual Defense Library (Ministerio de Defensa) · Cited by 1,017
Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants
Wang, G., Liu, W., Sivaprakasam, M., & Kendir, G. A. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.852923 · Cited by 435
An optimal design methodology for inductive power link with class-E amplifier
Kendir, G. A., Liu, W., Wang, G., Sivaprakasam, M., Bashirullah, R., Humayun, M. S., & Weiland, J. D. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.846208 · Cited by 222
Zierhofer, C. M., & Hochmair, E. S. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55682 · Cited by 214
Analysis of resonant coupled coils in the design of radio frequency transcutaneous links
Donaldson, N. D. N., & Perkins, T. A. (1983) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442388 · Cited by 211
Closed-loop class E transcutaneous power and data link for MicroImplants
Troyk, P. R., & Schwan, M. A. K. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141197 · Cited by 177
An Ultra-Low-Power Programmable Analog Bionic Ear Processor
Sarpeshkar, R., Salthouse, C., Sit, J.-J., Baker, M. W., Zhak, S. M., Lu, T. K.-T., Turicchia, L., & Balster, S. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.844043 · Cited by 171
Self-citation
Cited by
RamRakhyani, A. K., Mirabbasi, S., & Chiao, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2072782 · Cited by 945
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Jow, U.-M., & Ghovanloo, M. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.913130 · Cited by 630
Design and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission
Kiani, M., Jow, U.-M., & Ghovanloo, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2158431 · Cited by 591
Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue
Poon, A. S. Y., O'Driscoll, S., & Meng, T. H. (2010) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2010.2044310 · Cited by 469
The Circuit Theory Behind Coupled-Mode Magnetic Resonance-Based Wireless Power Transmission
Kiani, M., & Ghovanloo, M. (2012) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2011.2180446 · Cited by 421
Effect of Coupling Between Multiple Transmitters or Multiple Receivers on Wireless Power Transfer
Ahn, D., & Hong, S. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2196902 · Cited by 382
A Study on Magnetic Field Repeater in Wireless Power Transfer
Ahn, D., & Hong, S. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188254 · Cited by 351
Maximum Achievable Efficiency in Near-Field Coupled Power-Transfer Systems
Zargham, M., & Gulak, P. G. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2174794 · Cited by 349
Xue, R.-F., Cheng, K.-W., & Je, M. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2012.2209297 · Cited by 340
Review of piezoelectric micromachined ultrasonic transducers and their applications
Jung, J., Lee, W., Kang, W., Shin, E., Ryu, J., & Choi, H. (2017) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aa851b · Cited by 340
Analysis and Tracking of Optimal Load in Wireless Power Transfer Systems
Fu, M., Yin, H., Zhu, X., & Ma, C. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2347071 · Cited by 330
Energy harvesting for the implantable biomedical devices: issues and challenges
Hannan, M. A., Mutashar, S., Samad, S. A., & Hussain, A. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-79 · Cited by 322
Wireless Power Transmission With Self-Regulated Output Voltage for Biomedical Implant
Ahn, D., & Hong, S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2273472 · Cited by 315
Towards glucose biofuel cells implanted in human body for powering artificial organs: Review
Cosnier, S., Le Goff, A., & Holzinger, M. (2014) · Electrochemistry Communications · doi:10.1016/j.elecom.2013.09.021 · Cited by 291
Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments
Jow, U.-M., & Ghovanloo, M. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2025366 · Cited by 241
“maximize the amount of power induced in [5], [10]–[15].”
A Figure-of-Merit for Designing High-Performance Inductive Power Transmission Links
Kiani, M., & Ghovanloo, M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2227914 · Cited by 146
Wireless power transfer: systems, circuits, standards, and use cases
Van Mulders, J., Delabie, D., Lecluyse, C., Buyle, C., Callebaut, G., Van der Perre, L., & De Strycker, L. (2022) · Sensors · doi:10.3390/s22155573 · Cited by 141
Low-Power Circuits for Brain–Machine Interfaces
Sarpeshkar, R., Wattanapanitch, W., Arfin, S. K., Rapoport, B. I., Mandal, S., Baker, M. W., Fee, M. S., Musallam, S., & Andersen, R. A. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2003198 · Cited by 91
Self-citationIbrahim, A., Meng, M., & Kiani, M. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2812420 · Cited by 83
Inductive link design for medical implants
Ali, H., Ahmad, T. J., & Khan, S. A. (2009) · 2009 IEEE Symposium on Industrial Electronics & Applications · doi:10.1109/isiea.2009.5356376 · Cited by 41
Fundamental trade-offs between power and data transfer in inductive links for biomedical implants
Dehghanzadeh, P., Zamani, H., & Mandal, S. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3063376 · Cited by 7
“The properties of inductive power links have been extensively analyzed in prior work [6]–[8].”
BackgroundDesign Considerations for Implantable Neural Circuits and Systems
Hsu, W.-Y., Hsieh, P.-H., & Chen, H. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_19 · Cited by 1
Metadata
- Authors
- Baker, M. W., & Sarpeshkar, R.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2007-03
- Volume
- 1
- Issue
- 1
- Pages
- 28-38
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2158019432
- Cited by
- 317
- References
- 15
- FWCI
- 14.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.