The DOI matches its Crossref record; 69 of the 70 references it cites were found in a registry or an index.
A mm-Sized Wireless Implantable Device for Electrical Stimulation of Peripheral Nerves
Abstract
A wireless electrical stimulation implant for peripheral nerves, achieving >10× improvement over state of the art in the depth/volume figure of merit, is presented. The fully integrated implant measures just 2 mm × 3 mm × 6.5 mm (39 mm3, 78 mg), and operates at a large depth of 10.5 cm in a tissue phantom. The implant is powered using ultrasound and includes a miniaturized piezoelectric receiver (piezo), an IC designed in 180 nm HV BCD process, an off-chip energy storage capacitor, and platinum stimulation electrodes. The package also includes an optional blue light-emitting diode for potential applications in optogenetic stimulation in the future. A system-level design strategy for complete operation of the implant during the charging transient of the storage capacitor, as well as a unique downlink command/data transfer protocol, is presented. The implant enables externally programmable current-controlled stimulation of peripheral nerves, with a wide range of stimulation parameters, both for electrical (22 to 5000 μA amplitude, ~14 to 470 μs pulse-width, 0 to 60 Hz repetition rate) and optical (up to 23 mW/mm2optical intensity) stimulation. Additionally, the implant achieves 15 V compliance voltage for chronic applications. Full integration of the implant components, end-to-end in vitro system characterizations, and results for the electrical stimulation of a sciatic nerve, demonstrate the feasibility and efficacy of the proposed stimulator for peripheral nerves.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This depth is significantly greater than what current technologies offer, and it maintains a wide range of stimulation parameters, from 22 to 5,000 μA in amplitude and 14 to 470 μs in pulse-width (Charthad et al., 2018).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Charthad et al., 2018
In the citing paper
“This depth is significantly greater than what current technologies offer, and it maintains a wide range of stimulation parameters, from 22 to 5,000 μA in amplitude and 14 to 470 μs in pulse-width (Charthad et al., 2018).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Charthad et al., 2018
In the citing paper
“In a subsequent study by the same group, an implant of 2 mm × 3 mm × 6.5 mm dimensions achieved a remarkable depth of operation—10.5 cm in a tissue phantom.”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Charthad et al., 2018
In the citing paper
“Biphasic delivery of stimulus pulses is commonly achieved using a set of switches placed in a H-bridge structure. Each electrode operates as either a cathode or an anode from a single supply current, maximising flexibility and limiting the reliance on storage capacitors [57], [134].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [57]
In the citing paper
“The resulting increase in headroom that limits voltage compliance is addressed by external biasing, such as in wide swing current mirrors [57] shown in Fig. 5(a).”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [57]
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Comprehensive compilation of empirical ultrasonic properties of mammalian tissues
Goss, S. A., Johnston, R. L., & DUNN, F. L. (1978) · The Journal of the Acoustical Society of America · doi:10.1121/1.382016 · Cited by 1,126
Recruitment Patterns in Human Skeletal Muscle During Electrical Stimulation
Gregory, C. M., & Bickel, C. S. (2005) · Physical Therapy · doi:10.1093/ptj/85.4.358 · Cited by 615
Wirelessly powered, fully internal optogenetics for brain, spinal and peripheral circuits in mice
Montgomery, K. L., Yeh, A. J., Ho, J. S., Tsao, V., Mohan Iyer, S., Grosenick, L., Ferenczi, E. A., Tanabe, Y., Deisseroth, K., Delp, S. L., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3536 · Cited by 565
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557
A jump-start for electroceuticals
Famm, K., Litt, B., Tracey, K. J., Boyden, E. S., & Slaoui, M. (2013) · Nature · doi:10.1038/496159a · Cited by 554
Wireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541
Shin, G., Gomez, A. M., Al-Hasani, R., Jeong, Y. R., Kim, J., Xie, Z., Banks, A., Lee, S. M., Han, S. Y., Yoo, C. J., et al. (2017) · Neuron · doi:10.1016/j.neuron.2016.12.031 · Cited by 396
A Minimally Invasive 64-Channel Wireless μECoG Implant
Muller, R., Le, H., Li, W., Ledochowitsch, P., Gambini, S., Björninen, T., Koralek, A. C., Carmena, J. M., Maharbiz, M. M., Alon, E., et al. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2364824 · Cited by 372
Charge Pump Circuits: An Overview on Design Strategies and Topologies
Palumbo, G., & Pappalardo, D. (2010) · IEEE Circuits and Systems Magazine · doi:10.1109/mcas.2009.935695 · Cited by 341
Research works printed but not linked: 4
- zhou, 2009, Implantable Neural Prostheses 2 Techniques and Engineering Approaches
- chang, 0, A 30.5�mm3 fully packaged implantable device with duplex ultrasonic data and power links achieving 95�kb/s with <10?4 BER at 8.5 cm depth, Proc IEEE Int Solid-State Circuits Conf, 460
- yakovlev, 0, A 11 ?W sub-pJ/bit reconfigurable transceiver for�mm-sized wireless implants, Proc 2013 IEEE Custom Integrated Circuits Conf, 1
- lo, 0, A 176-channel 0.5 cm3 0.7 g wireless implant for motor function recovery after spinal cord injury, Proc IEEE Int Solid-State Circuits Conf, 382
Cited by
Sorted by citations
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Piezoelectric nanogenerators for personalized healthcare
Deng, W., Zhou, Y., Libanori, A., Chen, G., Yang, W., & Chen, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00858g · Cited by 448
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
Roy, S., Azad, A. N. M. W., Baidya, S., Alam, M. K., & Khan, F. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3164890 · Cited by 273
Ultrasound Technologies for Imaging and Modulating Neural Activity
Rabut, C., Yoo, S., Hurt, R. C., Jin, Z., Li, H., Guo, H., Ling, B., & Shapiro, M. G. (2020) · Neuron · doi:10.1016/j.neuron.2020.09.003 · Cited by 250
Sood, A., Desseigne, M., Dev, A., Maurizi, L., Kumar, A., Millot, N., & Han, S. S. (2022) · Small · doi:10.1002/smll.202206401 · Cited by 242
Zhang, M., Tang, Z., Liu, X., & Van der Spiegel, J. (2020) · Nature Electronics · doi:10.1038/s41928-020-0390-3 · Cited by 231
Triboelectric Nanogenerators for Therapeutic Electrical Stimulation
Conta, G., Libanori, A., Tat, T., Chen, G., & Chen, J. (2021) · Advanced Materials · doi:10.1002/adma.202007502 · Cited by 205
Zaeimbashi, M., Nasrollahpour, M., Khalifa, A., Romano, A., Liang, X., Chen, H., Sun, N., Matyushov, A. D., Lin, H., Dong, C., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23256-z · Cited by 205
Magnetoelectric effect: principles and applications in biology and medicine– a review
Kopyl, S., Surmenev, R., Surmeneva, M., Fetisov, Y., & Kholkin, A. (2021) · Materials Today Bio · doi:10.1016/j.mtbio.2021.100149 · Cited by 202
Liu, G., Lv, Z., Batool, S. A., Li, M.-Z., Zhao, P., Guo, L., Wang, Y., Zhou, Y., & Han, S. (2023) · Small · doi:10.1002/smll.202207879 · Cited by 196
Biointegrated and Wirelessly Powered Implantable Brain Devices: A Review
Das, R., Moradi, F., & Heidari, H. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2966920 · Cited by 174
Metasurfaces for bioelectronics and healthcare
Li, Z., Tian, X., Qiu, C., & Ho, J. S. (2021) · Nature Electronics · doi:10.1038/s41928-021-00589-7 · Cited by 167
Translational opportunities and challenges of invasive electrodes for neural interfaces
Shen, K., Chen, O., Edmunds, J. L., Piech, D. K., & Maharbiz, M. M. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01021-5 · Cited by 150
Dinis, H., & Mendes, P. M. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112781 · Cited by 138
Miniature battery-free bioelectronics
Nair, V., Dalrymple, A. N., Yu, Z., Balakrishnan, G., Bettinger, C. J., Weber, D. J., Yang, K., & Robinson, J. T. (2023) · Science · doi:10.1126/science.abn4732 · Cited by 128
Wireless technologies for implantable devices
Nelson, B. D., Karipott, S. S., Wang, Y., & Ong, K. G. (2020) · Sensors · doi:10.3390/s20164604 · Cited by 125
Lab‐on‐a‐Contact Lens: Recent Advances and Future Opportunities in Diagnostics and Therapeutics
Zhu, Y., Li, S., Li, J., Falcone, N., Cui, Q., Shah, S., Hartel, M. C., Yu, N., Young, P., de Barros, N. R., et al. (2022) · Advanced Materials · doi:10.1002/adma.202108389 · Cited by 125
NanoNeuroRFID: A Wireless Implantable Device Based on Magnetoelectric Antennas
Zaeimbashi, M., Lin, H., Dong, C., Liang, X., Nasrollahpour, M., Chen, H., Sun, N., Matyushov, A. D., He, Y., Wang, X., et al. (2019) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2019.2903930 · Cited by 120
The Microbead: A 0.009 mm 3 Implantable Wireless Neural Stimulator
Khalifa, A., Liu, Y., Karimi, Y., Wang, Q., Eisape, A. A., Stanaćević, M., Thakor, N. V., Bao, Z., & Etienne‐Cummings, R. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2939014 · Cited by 121
Application of a sub–0.1-mm 3 implantable mote for in vivo real-time wireless temperature sensing
Shi, C., Andino-Pavlovsky, V., Lee, S. A., Costa, T. L., Elloian, J. M., Konofagou, E. E., & Shepard, K. L. (2021) · Science Advances · doi:10.1126/sciadv.abf6312 · Cited by 119
A Trimodal Wireless Implantable Neural Interface System-on-Chip
Jia, Y., Güler, Ü., Lai, Y.-P., Gong, Y. P., Weber, A. J., Li, W., & Ghovanloo, M. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3037452 · Cited by 104
Bioelectronic Implantable Devices for Physiological Signal Recording and Closed‐Loop Neuromodulation
Oh, S., Jekal, J., Jia Liu, B., Kim, J., Park, J., Lee, T., & Jang, K. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202403562 · Cited by 104
Applications of Microwaves in Medicine
Chiao, J. ‐., Li, C., Lin, J., Caverly, R. H., Hwang, J. C. M., Rosen, H. D., & Rosen, A. (2022) · IEEE Journal of Microwaves · doi:10.1109/jmw.2022.3223301 · Cited by 94
An Inductively-Powered Wireless Neural Recording and Stimulation System for Freely-Behaving Animals
Lee, B., Jia, Y., Mirbozorgi, S. A., Connolly, M. J., Tong, X., Zeng, Z., Mahmoudi, B., & Ghovanloo, M. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2891303 · Cited by 92
Ultrasound‐Powered Implants: A Critical Review of Piezoelectric Material Selection and Applications
Turner, B. L., Senevirathne, S., Kilgour, K. M., McArt, D. G., Biggs, M. J. P., Menegatti, S., & Daniele, M. A.-A. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100986 · Cited by 90
An Implantable Ultrasonically-Powered Micro-Light-Source (µLight) for Photodynamic Therapy
Kim, A., Zhou, J., Samaddar, S., Song, S. H., Elzey, B. D., Thompson, D. H., & Ziaie, B. (2019) · Scientific Reports · doi:10.1038/s41598-019-38554-2 · Cited by 85
A Dual-Band Wireless Power Transmission System for Evaluating mm-Sized Implants
Jia, Y., Mirbozorgi, S. A., Zhang, P., Inan, O. T., Li, W., & Ghovanloo, M. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2915649 · Cited by 69
MagNI: A Magnetoelectrically Powered and Controlled Wireless Neurostimulating Implant
Yu, Z., Chen, J. C., Alrashdan, F. T., Avants, B. W., He, Y., Singer, A., Robinson, J. T., & Yang, K. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3037862 · Cited by 72
A mm-Sized Free-Floating Wirelessly Powered Implantable Optical Stimulation Device
Jia, Y., Mirbozorgi, S. A., Lee, B., Khan, W., Madi, F., Inan, O. T., Weber, A. J., Li, W., & Ghovanloo, M. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2918761 · Cited by 67
Xu, S., Momin, M., Ahmed, S., Hossain, A., Veeramuthu, L., Pandiyan, A., Kuo, C., & Zhou, T. (2023) · Advanced Materials · doi:10.1002/adma.202303267 · Cited by 70
Integrated Circuits for Medical Ultrasound Applications: Imaging and Beyond
Zhang, Y., & Demosthenous, A. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3120886 · Cited by 64
Shi, C., Costa, T. L., Elloian, J. M., Zhang, Y., & Shepard, K. L. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2971066 · Cited by 56
Chang, T. C., Weber, M. J., Charthad, J., Baltsavias, S., & Arbabian, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2871470 · Cited by 53
Self-citationReStore: A wireless peripheral nerve stimulation system
Sivaji, V., Grasse, D. W., Hays, S. A., Bucksot, J. E., Saini, R., Kilgard, M. P., & Rennaker, R. L. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.02.010 · Cited by 52
Physical Cue‐Based Strategies on Peripheral Nerve Regeneration
Wei, Z., Jin, F., Li, T., Qian, L., Zheng, W., Wang, T., & Feng, Z. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202209658 · Cited by 50
An Integrated 2D Ultrasound Phased Array Transmitter in CMOS With Pixel Pitch-Matched Beamforming
Costa, T. L., Shi, C., Tien, K., Elloian, J. M., Cardoso, F. A., & Shepard, K. L. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3096722 · Cited by 51
ElAnsary, M., Xu, J., Filho, J. S., Dutta, G., Long, L., Tejeiro, C., Shoukry, A., Tang, C., Kilinc, E., Joshi, J., et al. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3113354 · Cited by 48
Lyu, H., Wang, J., La, J.-H., Chung, J. M., & Babakhani, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2852680 · Cited by 47
Roy, S., Azad, A. N. M. W., Baidya, S., & Khan, F. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3075245 · Cited by 46
Electrical Stimulation for Immune Modulation in Cancer Treatments
Das, R., Langou, S., Le, T. T., Prasad, P., Lin, F., & Nguyen, T. D. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.795300 · Cited by 44
Direct AC–AC Active-Clamped Half-Bridge Converter for Inductive Charging Applications
Huynh, P. S., Ronanki, D., Vincent, D., & Williamson, S. S. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3009395 · Cited by 44
Xu, Z., Khalifa, A., Mittal, A., Nasrollahpour, M., Das, D., Onabajo, M., Sun, N. X., Cash, S. S., & Shrivastava, A. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2022.3180633 · Cited by 43
Ceramic packaging in neural implants
Shen, K., & Maharbiz, M. M. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abd683 · Cited by 47
Developing Next-Generation Brain Sensing Technologies—A Review
Robinson, J. T., Xie, C., Pohlmeyer, E. A., Gather, M. C., Kemere, C. T., Kitching, J. E., Malliaras, G. G., Marblestone, A. H., Shepard, K. L., & Stieglitz, T. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2931159 · Cited by 45
Marques‐Almeida, T., Lanceros-Méndez, S., & Ribeiro, C. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202301494 · Cited by 42
Injectable wireless microdevices: challenges and opportunities
Khalifa, A., Lee, S., Molnar, A. C., & Cash, S. S. (2021) · Bioelectronic Medicine · doi:10.1186/s42234-021-00080-w · Cited by 39
Wu, P., Zhao, Y., Chen, F., Xiao, A., Du, Q., Dong, Q., Ke, M., Liang, X., Zhou, Q., & Chen, Y. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00709 · Cited by 38
Threat Modeling and Risk Analysis for Miniaturized Wireless Biomedical Devices
Vakhter, V., Soysal, B., Schaumont, P. R., & Güler, Ü. (2022) · IEEE Internet of Things Journal · doi:10.1109/jiot.2022.3144130 · Cited by 49
Kashani, Z., Ilham, S. J., & Kiani, M. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3140591 · Cited by 38
A Reconfigurable Passive RF-to-DC Converter for Wireless IoT Applications
Güler, Ü., Jia, Y., & Ghovanloo, M. (2019) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2019.2894562 · Cited by 35
26.8 A Trimodal Wireless Implantable Neural Interface System-on-Chip
Jia, Y., Güler, Ü., Lai, Y.-P., Gong, Y. P., Weber, A. J., Li, W., & Ghovanloo, M. (2020) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc19947.2020.9063065 · Cited by 35
Challenges in Scaling Down of Free-Floating Implantable Neural Interfaces to Millimeter Scale
Yang, K.-W. K., Oh, K., & Ha, S. (2020) · IEEE Access · doi:10.1109/access.2020.3007517 · Cited by 32
Magnetoelectrics enables large power delivery to mm-sized wireless bioelectronics
Kim, W., Tuppen, C. A., Alrashdan, F. T., Singer, A. L., Weirnick, R., & Robinson, J. T. (2023) · Journal of Applied Physics · doi:10.1063/5.0156015 · Cited by 31
Lee, H.-S., Ahn, J., Eom, K., Jung, W., Lee, S. H., Jung, Y.-W., Shin, S.-U., & Lee, H. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3151427 · Cited by 31
Phased Array Beamforming Methods for Powering Biomedical Ultrasonic Implants
Benedict, B. C., Ghanbari, M. M., & Muller, R. (2022) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2022.3197705 · Cited by 30
Rashidi, A., Laursen, K., Hosseini, S., Huynh, H.-A., & Moradi, F. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2949154 · Cited by 30
A Study on Ultrasonic Wireless Power Transfer With Phased Array for Biomedical Implants
Kashani, Z., & Kiani, M. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3282197 · Cited by 28
Magnetoelectric backscatter communication for millimeter-sized wireless biomedical implants
Yu, Z., Alrashdan, F. T., Wang, W., Parker, M., Chen, X., Chen, F. Y., Woods, J. E., Chen, Z., Robinson, J. T., & Yang, K. (2022) · ACM Annual International Conference on Mobile Computing and Networking (MobiCom) · doi:10.1145/3495243.3560541 · Cited by 27
Ultrasonically Powered Compact Implantable Dust for Optogenetics
Laursen, K., Rashidi, A., Hosseini, S., Mondal, T., Corbett, B., & Moradi, F. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2984921 · Cited by 27
Lyu, H., Gad, P., Zhong, H., Edgerton, V. R., & Babakhani, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2879357 · Cited by 26
Javan‐Khoshkholgh, A., & Farajidavar, A. (2021) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2021.3084516 · Cited by 27
Bijak, M., Schmoll, M., Jarvis, J. C., Unger, E., & Lanmüller, H. (2020) · PLoS ONE · doi:10.1371/journal.pone.0241638 · Cited by 26
Omnidirectional Wireless Power Transfer for Millimetric Magnetoelectric Biomedical Implants
Wang, W., Yu, Z., Zou, Y., Woods, J. E., Chari, P., Su, Y., Robinson, J. T., & Yang, K. (2024) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2024.3464533 · Cited by 26
Physical Stimulation Combined with Biomaterials Promotes Peripheral Nerve Injury Repair
Zeng, Z., Yang, Y., Deng, J., Rahman, M. S. U., Sun, C., & Xu, S. (2022) · Bioengineering · doi:10.3390/bioengineering9070292 · Cited by 25
Ultrasonic Implant Localization for Wireless Power Transfer: Active Uplink and Harmonic Backscatter
Wang, M. L., Chang, T. C., & Arbabian, A. (2019) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2019.8926006 · Cited by 24
Self-citationComparative analysis of energy transfer mechanisms for neural implants
Miziev, S., Pawlak, W. A., & Howard, N. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1320441 · Cited by 21
ElAnsary, M., Xu, J., Filho, J. S., Dutta, G., Long, L., Shoukry, A., Tejeiro, C., Tang, C., Kilinc, E. G., Joshi, J., et al. (2021) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc42613.2021.9365856 · Cited by 22
Kawasaki, S., Westhoek, Y., Subramaniam, I., Saccher, M., & Dekker, R. H. (2021) · IEEE Wireless Power Transfer Conference · doi:10.1109/wptc51349.2021.9458104 · Cited by 21
A Fully Implantable Opto-Electro Closed-Loop Neural Interface for Motor Neuron Disease Studies
Liu, F., Wu, Y., Almarri, N., Habibollahi, M., Lancashire, H. T., Bryson, J. B., Greensmith, L., Jiang, D., & Demosthenous, A. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3202026 · Cited by 21
A Circularly Polarized Implantable Rectenna for Microwave Wireless Power Transfer
Xu, C., Fan, Y., & Liu, X. (2022) · Micromachines · doi:10.3390/mi13010121 · Cited by 21
Allam, A., Sabra, K. G., & Ertürk, A. (2022) · Smart Materials and Structures · doi:10.1088/1361-665x/ac7b57 · Cited by 20
SenseBack - An Implantable System for Bidirectional Neural Interfacing
Williams, I., Brunton, E., Rapeaux, A., Liu, Y., Luan, S., Nazarpour, K., & Constandinou, T. G. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3022839 · Cited by 23
A Highly Miniaturized, Chronically Implanted ASIC for Electrical Nerve Stimulation
Shah, J. V., Quinkert, C., Collar, B., Williams, M., Biggs, E. N., & Irazoqui, P. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3153282 · Cited by 19
An Ultrasonic Energy Harvesting IC Providing Adjustable Bias Voltage for Pre-Charged CMUT
Zhao, L.-R., Annayev, M., Oralkan, O., & Jia, Y.-Y. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3178581 · Cited by 15
Evolution of Biotelemetry in Medical Devices: From Radio Pills to mm-Scale Implants
Valente, V. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3190767 · Cited by 19
Wireless Power Transfer and Management for Medical Applications: Wireless power
Kiani, M. (2022) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2022.3178671 · Cited by 19
Miniaturized Wirelessly Powered and Controlled Implants for Multisite Stimulation
Habibagahi, I., Jang, J., & Babakhani, A. (2023) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2022.3233368 · Cited by 19
Shon, A., Brakel, K., Hook, M. A., & Park, H. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3072894 · Cited by 19
Kassiri, H., Muneeb, A., Salahi, R., & Dabbaghian, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3456825 · Cited by 19
A Wireless Implantable Closed-Loop Electrochemical Drug Delivery System
Wang, M. L., Yeon, P., Mofidfar, M., Chamberlayne, C. F., Xu, H., Annes, J. P., Zare, R. N., & Arbabian, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3507022 · Cited by 18
Self-citationBhat, A. R., Pratihar, S., Manzoor, S., Chandran, A. M., Yella, A., & Mural, P. K. S. (2024) · ACS Applied Nano Materials · doi:10.1021/acsanm.4c00732 · Cited by 18
Metasurface Patch for Wireless Power Transfer in Implantable Devices
Jo, S., Lee, W., & Lee, H. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202300027 · Cited by 18
Inductively coupled, mm-sized, single channel optical neuro-stimulator with intensity enhancer
Khan, W., Jia, Y., Madi, F., Weber, A. J., Ghovanloo, M., & Li, W. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0061-6 · Cited by 17
Assessment of miniaturized ultrasound-powered implants: an in vivo study
Vo, J., Chang, T. C., Shea, K. I., Myers, M. R., Arbabian, A., & Vasudevan, S. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab6fc2 · Cited by 16
Self-citationKhan, S. R., Mugisha, A. J., Tsiamis, A., & Mitra, S. (2022) · Sensors · doi:10.3390/s22103635 · Cited by 16
Recent Advances in Implantable Neural Interfaces for Multimodal Electrical Neuromodulation
Wang, L., Liu, S., Zhao, W., Li, J., Zeng, H., Kang, S., Sheng, X., Wang, L., Fan, Y., & Yin, L. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202303316 · Cited by 16
An Ultrasonically Powered and Controlled Ultra-High-Frequency Biphasic Electrical Neurostimulator
Tacchetti, L., Serdijn, W. A., & Giagka, V. (2018) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2018.8584718 · Cited by 15
Lamkaddem, A., Yousfi, A. E., Huang, Y., González‐Posadas, V., & Segovia-Vargas, D. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3587334 · Cited by 14
Cho, J., Seong, G., Chang, Y., & Kim, C. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.667447 · Cited by 18
Minimum On-the-node Data Security for the Next-generation Miniaturized Wireless Biomedical Devices
Vakhter, V., Soysal, B., Schaumont, P. R., & Güler, Ü. (2020) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas48704.2020.9184564 · Cited by 14
Park, M., Eom, K., Lee, H.-S., Ku, S.-B., & Lee, H. (2023) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2023.3335158 · Cited by 13
A simple method for implanting free-floating microdevices into the nervous tissue
Khalifa, A., Eisape, A. A., Coughlin, B. F., & Cash, S. S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf590 · Cited by 13
Zhou, Y., Wang, K., Yin, S., Li, W.-Y., Meng, F., Wang, Z.-G., & Ma, K. (2024) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2024.3376370 · Cited by 12
Eom, K., Lee, H.-S., Park, M., Yang, S. M., Choe, J. C., Hwang, S., Suh, Y.-W., & Lee, H. (2023) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2023.3334753 · Cited by 12
Yuan, N., Carnicer‐Lombarte, A., Gong, Y., Sun, S., Rong, Z., Middya, S., Pang, W., Malliaras, G. G., & Zhang, M. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.135382 · Cited by 12
Kim, H., Park, Y., Sung, C., Cho, J., Park, S., & Kim, C. (2024) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2024.3372418 · Cited by 13
Augmented ultrasonography with implanted CMOS electronic motes
Zhang, Y., Muthuraman, P., Andino-Pavlovsky, V., Uguz, I., Elloian, J. M., & Shepard, K. L. (2022) · Nature Communications · doi:10.1038/s41467-022-31166-x · Cited by 12
Bioelectronic devices for light-based diagnostics and therapies
Kim, H., Sritandi, W., Xiong, Z., & Ho, J. S. (2023) · Biophysics Reviews · doi:10.1063/5.0102811 · Cited by 12
Holzapfel, L., & Giagka, V. (2024) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2024.3465268 · Cited by 12
Metadata
- Authors
- Charthad, J., Chang, T. C., Liu, Z., Sawaby, A., Weber, M. J., Baker, S., Gore, F., Felt, S. A., & Arbabian, A.
- Affiliations
- Stanford University (US)
- University of California, Berkeley (US)
- ORCID
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2018-04
- Volume
- 12
- Issue
- 2
- Pages
- 257-270
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2790547683
- Cited by
- 230
- References
- 70
- Citations by year
- 2026: 16 · 2025: 17 · 2024: 24 · 2023: 41 · 2022: 40 · 2021: 32 · 2020: 38 · 2019: 16 · 2018: 6
- FWCI
- 10.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
- PubMed (publishedVersion)
- Funders
- DARPA Young Faculty Award
- National Science Foundation CAREER Award (ECCS-1454107)
- NSF Graduate Research Fellowships Program (DGE-114747)
- Stanford internal seed funds
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- peripheral nerve stimulation, piezoelectric receiver, energy storage capacitors, optogenetic stimulation, blue LEDs, sciatic nerve stimulation
- MeSH terms
- Electrodes, Implanted, Electric Stimulation Therapy, Equipment Design, Humans, Models, Theoretical, Peripheral Nerves
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review