The DOI matches its Crossref record; 43 of the 44 references it cites were found in a registry or an index.
An Energy-Efficient Wirelessly Powered Millimeter-Scale Neurostimulator Implant Based on Systematic Codesign of an Inductive Loop Antenna and a Custom Rectifier
Abstract
In this work, a switched-capacitor-based stimulator circuit that enables efficient energy harvesting for neurostimulation applications is presented, followed by the discussion on the optimization of the inductive coupling front-end through a codesign approach. The stimulator salvages input energy and stores it in a storage capacitor, and, when the voltage reaches a threshold, releases the energy as an output stimulus. The dynamics of the circuit are automatically enabled by a positive feedback, eliminating any stimulation control circuit blocks. The IC is fabricated in a 180 nm CMOS process and achieves a quiescent current consumption of 1.8 μA. The inductive coupling front-end is optimized as a loaded resonator, in which the input impedance of the custom rectifier directly loads the inductive loop antenna. The loaded quality factor and the rectifier's efficiency determine the reception sensitivity of the stimulator, while a balance should be achieved for the robustness of the system against dielectric medium variations by increasing the reception bandwidth. The finalized stimulator adopts a 4.9 mm × 4.9 mm inductive loop antenna and achieves an overall assembly dimension of 5 mm × 7.5 mm. Operating at the resonant frequency of 198 MHz, the stimulator works at a 14 cm distance from the transmitter in the air. An animal experiment was performed, in which a fully implanted stimulator excited the sciatic nerve of a rat that consequently triggered the movement of the limb.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While many remain battery-powered, wireless power transfer techniques can further reduce the form factor and invasiveness of these devices4–10.”
From Synchronized Biventricular Heart Pacing in a Closed-chest Porcine Model based on Wirelessly Powered Leadless Pacemakers (2020) · cites this paper as [6]
In the citing paper
“It is remarkable that unlike prior arts operating at hundreds of MHz4,6,7, the proposed inductive coupling links at 13.56 MHz and 40.68 MHz bands render SARs 2–3 orders of magnitude lower than the safety regulation threshold.”
From Synchronized Biventricular Heart Pacing in a Closed-chest Porcine Model based on Wirelessly Powered Leadless Pacemakers (2020) · cites this paper as [6]
In the citing paper
“For instance, a study by Lyu et al. developed a miniaturized stimulator measuring 5 mm × 7.5 mm in size, operating at a resonant frequency of 198 MHz and capable of functioning at a 14 cm distance from the external transmitter.”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Lyu et al., 2018
In the citing paper
“This compact stimulator uses stored energy to deliver its output stimulus, eliminating the need for a separate stimulation control circuit block (Lyu et al., 2018).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Lyu et al., 2018
Citations
Cites
Wireless Power Transfer via Strongly Coupled Magnetic Resonances
Kurs, A., Karalis, A., Moffatt, R., Joannopoulos, J. D., Fisher, P., & Soljačić, M. (2007) · Science · doi:10.1126/science.1143254 · Cited by 5,576
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Dickson, J. F. (1976) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1976.1050739 · Cited by 1,686
Efficient wireless non-radiative mid-range energy transfer
Karalis, A., Joannopoulos, J. D., & Soljačić, M. (2008) · Annals of Physics · doi:10.1016/j.aop.2007.04.017 · Cited by 1,394
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975 · cited 1×
“Energy sources such as solar [6], piezoelectric [7], bio-potential [8], and glucose biofuel [9], have been proposed to power IMDs.”
BackgroundRamRakhyani, A. K., Mirabbasi, S., & Chiao, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2072782 · Cited by 945
Efficient Far-Field Radio Frequency Energy Harvesting for Passively Powered Sensor Networks
Le, T., Mayaram, K., & Fiez, T. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.920318 · Cited by 734
High intensity focused ultrasound: surgery of the future?
Kennedy, J. E., ter Haar, G. R., & Cranston, D. (2003) · The British Journal of Radiology · doi:10.1259/bjr/17150274 · Cited by 709
Wirelessly powered, fully internal optogenetics for brain, spinal and peripheral circuits in mice
Montgomery, K. L., Yeh, A. J., Ho, J. S., Tsao, V., Mohan Iyer, S., Grosenick, L., Ferenczi, E. A., Tanabe, Y., Deisseroth, K., Delp, S. L., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3536 · Cited by 565
Cited by
Zaeimbashi, M., Nasrollahpour, M., Khalifa, A., Romano, A., Liang, X., Chen, H., Sun, N., Matyushov, A., Lin, H., Dong, C., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23256-z · Cited by 201
Magnetoelectric effect: principles and applications in biology and medicine– a review
Kopyl, S., Surmenev, R., Surmeneva, M., Fetisov, Y., & Kholkin, A. (2021) · Materials Today Bio · doi:10.1016/j.mtbio.2021.100149 · Cited by 202
Wireless power transfer approaches for medical implants: a review
Haerinia, M., & Shadid, R. (2020) · Signals · doi:10.3390/signals1020012 · Cited by 174
“[8] have developed a stimulator that occupies an area of 5 mm × 7.”
BackgroundEnergy Harvesting in Implantable and Wearable Medical Devices for Enduring Precision Healthcare
Shuvo, M. M. H., Titirsha, T., Amin, N., & ISLAM, S. K. (2022) · Energies · doi:10.3390/en15207495 · Cited by 147
NanoNeuroRFID: A Wireless Implantable Device Based on Magnetoelectric Antennas
Zaeimbashi, M., Lin, H., Dong, C., Liang, X., Nasrollahpour, M., Chen, H., Sun, N., Matyushov, A. D., He, Y., Wang, X., et al. (2019) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2019.2903930 · Cited by 125
The Microbead: A 0.009 mm 3 Implantable Wireless Neural Stimulator
Khalifa, A., Liu, Y., Karimi, Y., Wang, Q., Eisape, A. A., Stanaćević, M., Thakor, N. V., Bao, Z., & Etienne‐Cummings, R. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2939014 · Cited by 122
MagNI: A Magnetoelectrically Powered and Controlled Wireless Neurostimulating Implant
Yu, Z., Chen, J. C., Alrashdan, F. T., Avants, B. W., He, Y., Singer, A., Robinson, J. T., & Yang, K. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3037862 · Cited by 77
Near-field wireless power transfer used in biomedical implants: a comprehensive review
Mahmood, A. I., Gharghan, S. K., Eldosoky, M. A., & Soliman, A. M. (2022) · IET Power Electronics · doi:10.1049/pel2.12351 · Cited by 59
Lyu, H., John, M., Burkland, D., Greet, B., Post, A., Babakhani, A., & Razavi, M. (2020) · Scientific Reports · doi:10.1038/s41598-020-59017-z · Cited by 51
“While many remain battery-powered, wireless power transfer techniques can further reduce the form factor and invasiveness of these devices [4] [5] [6] [7] [8] [9] [10] .”
BackgroundSelf-citationA UHF/UWB Hybrid RFID Tag With a 51-m Energy-Harvesting Sensitivity for Remote Vital-Sign Monitoring
Lyu, H., Wang, Z., & Babakhani, A. (2020) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2020.3017674 · Cited by 40
“swing that may affect long-time endurance [31].”
Self-citationWireless energy and information transfer in WBAN: A comprehensive state-of-the-art review
Zhumayeva, M., Dautov, K., Hashmi, M., & Nauryzbayev, G. (2023) · Alexandria Engineering Journal · doi:10.1016/j.aej.2023.11.030 · Cited by 43
Vagus nerve stimulation using a miniaturized wirelessly powered stimulator in pigs
Habibagahi, I., Omidbeigi, M., Hadaya, J. E., Lyu, H., Jang, J., Ardell, J. L., Bari, A., & Babakhani, A. (2022) · Scientific Reports · doi:10.1038/s41598-022-11850-0 · Cited by 32
Self-citationTissue-Dependent Co-Matching Method for Dual-Mode Antenna in Implantable Neurostimulators
Feng, Y., Li, Y., Li, L., Ma, B., Hao, H., & Li, L. (2019) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2019.2916736 · Cited by 28
Lyu, H., Gad, P., Zhong, H., Edgerton, V. R., & Babakhani, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2879357 · Cited by 26
“multiplication of Q and the intrinsic conversion efficiency, η, of the rectifier [20].”
Self-citationLyu, H., Liu, X., Sun, Y., Jian, Z., & Babakhani, A. (2019) · IEEE Microwave and Wireless Components Letters · doi:10.1109/lmwc.2019.2923685 · Cited by 23
“The power conditioning circuit has been previously discussed in [1], [5].”
BackgroundSelf-citationComparative analysis of energy transfer mechanisms for neural implants
Miziev, S., Pawlak, W. A., & Howard, N. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1320441 · Cited by 21
Lyu, H., & Babakhani, A. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3047827 · Cited by 24
“to purposefully decrease the quality factor in a trade-off for a wider bandwidth, which, of course, sacrifices the optimal efficiency [24]–[26].”
BackgroundSelf-citationAn Integrated RF-Powered Wake-Up Wireless Transceiver With –26 dBm Sensitivity
Karami, M. A., & Moez, K. K. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2021.3116208 · Cited by 20
Dual-Band Antenna at 28 and 38 GHz Using Internal Stubs and Slot Perturbations
Shariff, B. G. P., Kumar, P., Mane, P. R., Pathan, S., Ali, T., Boulogeorgos, A. A., & Anguera, J. (2024) · Technologies · doi:10.3390/technologies12060084 · Cited by 19
Das, D., Xu, Z., Nasrollahpour, M., Martos-Repath, I., Zaeimbashi, M., Khalifa, A., Mittal, A., Cash, S. S., Sun, N. X., Shrivastava, A., et al. (2023) · IEEE Open Journal of Circuits and Systems · doi:10.1109/ojcas.2023.3259233 · Cited by 18
“CMOS-based rectifier topologies, such as the conventional Dickson rectifier [75] or the cross-connected differential topology [76], are widely used in modern wireless IMDs to inject charges to the tissue from scavenging the incoming RF energy [77], [78], [79].”
BackgroundStretchable Transparent Wireless Charging Coil Fabricated by Negative Transfer Printing
Zhang, Z., Alwen, A., Lyu, H., Liu, X., Li, Z., Xie, Z., Xie, Y. B., Guan, F., Babakhani, A., & Pei, Q. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b14728 · Cited by 15
Self-citationLyu, H., Jian, Z., Liu, X., Sun, Y., & Babakhani, A. (2019) · IEEE Sensors Letters · doi:10.1109/lsens.2019.2896185 · Cited by 13
Self-citationTaghadosi, M., & Kassiri, H. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3123160 · Cited by 13
Limpisawas, T., & Wattanapanitch, W. (2022) · IEEE Access · doi:10.1109/access.2022.3185630 · Cited by 11
Wirelessly-Powered Dielectric Sensor With On-Chip Antennas in 180 nm SOI CMOS Process
Sun, Y., & Babakhani, A. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2888620 · Cited by 10
Self-citationA Chip Integrity Monitor for Evaluating Moisture/Ion Ingress in mm-Sized Single-Chip Implants
Akgun, Ö. C., Nanbakhsh, K., Giagka, V., & Serdijn, W. A. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3007484 · Cited by 10
“In this regard, wireless energy transfer techniques using electromagnetic [5], [6], [7], [8], [9] and acoustic energy [10], [11], [12] have been recently proposed as alternative energy delivery solutions that can circumvent the size restriction of the battery and enable the realization of free-floating mm-sized single…”
BackgroundChu, Z., Zhou, Y., Li, S. Z., Xu, Q., & Pan, L. (2025) · Applied Sciences · doi:10.3390/app15137599 · Cited by 11
Remotely Controlled Electrochemical Degradation of Metallic Implants
Rivkin, B. B., Akbar, F., Otto, M., Beyer, L., Paul, B., Kosiba, K., Gustmann, T., Hufenbach, J., & Medina‐Sánchez, M. (2024) · Small · doi:10.1002/smll.202307742 · Cited by 9
Benbuk, A. A., Esmaeili, H., Liu, S., Patino-Guerrero, A., Migrino, R. Q., Chae, J., Nikkhah, M., & Christen, J. B. (2022) · ACS Sensors · doi:10.1021/acssensors.2c00794 · Cited by 7
Wireless closed-loop deep brain stimulation using microelectrode array probes
Jia, Q., Liu, Y., Lv, S., Wang, Y., Jiao, P., Xu, W., Xu, Z., Wang, M., & Cai, X. (2024) · Journal of Zhejiang University SCIENCE B · doi:10.1631/jzus.b2300400 · Cited by 7
“These types of energy are converted from alternating current to direct current by rectifiers in a wireless power supply module to prolong the lifespan of the batteries inside the body by increasing the efficiency of electrical conversion (Lyu et al., 2018; Gong, 2022).”
Compact Dual-Band Implantable Asymmetric Multi-Slot Patch Antenna for WMTS and ISM Applications
Bharadwaj, I. S., Kumar, S., & Kumar, V. (2023) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon58879.2023.10322398 · Cited by 5
“Loop antennas are suggested for biomedical applications by authors in [6] & [7].”
BackgroundA 100-M/s 2.6-pJ/pulse compact UWB impulse transmitter based on antenna-and-pulse-generator codesign
Lyu, H., Liu, X., & Babakhani, A. (2019) · IEICE Electronics Express · doi:10.1587/elex.16.20190672 · Cited by 5
“The folded-dipole antenna is selected for its compact size, wide bandwidth, and omnidirectional radiation pattern [18-23], which is particularly promising for a wide range of efforts on the miniaturization of various medical implants [24-29].”
BackgroundSelf-citationA Current-Switching Technique for Intra-Body Communication With Miniaturized Electrodes
Wang, W., Pun, K., & Zhao, B. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3125422 · Cited by 3
A State of Art Review on Wireless Power Transmission Approaches for Implantable Medical DevicesPreprint
Haerinia, M. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2003.01240 · Cited by 4
“Figure 2: In vivo experiment with the stimulator fully implanted on the sciatic nerve [8].”
BackgroundInfluentialNEMS magnetoelectric antennas: Physics, fabrication, and nanoscale wireless sensing paradigms
Al-Gburi, A. J. A. (2026) · Materials Science in Semiconductor Processing · doi:10.1016/j.mssp.2026.110832 · Cited by 2
Benbuk, A. A., Gulick, D. W., Garcia, D. P. M., Liu, S., Quiñones‐Hinojosa, A., & Christen, J. B. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3329447 · Cited by 2
“Delivering power at a higher frequency allows reduced size of the transmit and receive antennas, at the expense of increased signal attenuation in lossy tissue media [21].”
Hu, S., Bao, J., Hu, G., Ta, D., Liu, R., & Zheng, L. (2020) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2020.3037810 · Cited by 2
Wireless Power Transfer for Implantable and Wearable Medical Devices
Haerinia, M., Shadid, R., & Noghanian, S. (2021) · Signals and communication technology · doi:10.1007/978-3-030-74311-6_12 · Cited by 2
Wang, Y., Tian, J., Xu, Z., Zhang, C., Wu, J., Liu, M., Ye, Z., & Zhang, X. (2026) · Advanced Science · doi:10.1002/advs.75833 · Cited by 1
SPACEMan: Wireless SoC for Concurrent Potentiometry and Amperometry
Ma, D., Chen, Y., Ghoreishizadeh, S. S., & Georgiou, P. (2021) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas51556.2021.9401312 · Cited by 1
Fully Implantable Neural Stimulator with Variable Parameters
Pan, T., & Zou, Y. (2022) · Electronics · doi:10.3390/electronics11071104 · Cited by 1
“Both stainless steel electrodes [36] and Mg electrodes [5] can be used in experiments.”
MethodMethods and techniques for magnetic neural stimulation and recording
Zaeimbashi, M. (2020) · Digital Repository Service (Northeastern University) · doi:10.17760/d20385568 · Cited by 1
Yuvarajan, A., Vishnu, G., & Saranraj, N. (2025) · Biomedical Materials & Devices · doi:10.1007/s44174-025-00282-9 · Cited by 2
Taylor, P. S., & Batchelor, J. C. (2023) · International Conference on Smart and Sustainable Technologies (SpliTech) · doi:10.23919/splitech58164.2023.10193598
“Common AIMDs are cardiovascular devices [1], glucose monitors [2] – [4], defibrillators [5], neurostimulators [6] cochlear and ocular implants [7] – [9] and micro electromechanical systems (MEMS) [10].”
BackgroundSystem Design Examples: Peripheral Nerve Implants and Neurostimulators
Guo, Y., Feng, Y., & Liu, C. (2024) · doi:10.1002/9781119189947.ch9
Energy-efficient neural stimulation system design for implantable medical devices
Kang, J., Eom, K., Lee, H.-S., Lee, H.-S., Jung, H., Chon, H., Ahn, M., & Lee, H. (2026) · Biomedical Engineering Letters · doi:10.1007/s13534-026-00572-1 · Cited by 1
Burra, R., Movva, A. K., Tennyson, J. M., Yates, S. J., Sohn, M. O., Chen, A., Rocos, B., & Anastasio, A. T. (2026) · Electronics · doi:10.3390/electronics15112484
Metadata
- Authors
- Lyu, H., Wang, J., La, J.-H., Chung, J. M., & Babakhani, A.
- Affiliations
- Rice University (US)
- The University of Texas Medical Branch at Galveston (US)
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2018-10
- Volume
- 12
- Issue
- 5
- Pages
- 1131-1143
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2886324498
- Cited by
- 47
- References
- 44
- Citations by year
- 2026: 4 · 2025: 2 · 2024: 5 · 2023: 5 · 2022: 6 · 2021: 7 · 2020: 9 · 2019: 7 · 2018: 2
- FWCI
- 2.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- implantable neurostimulator, wireless power transfer, inductive coupling, rectifier, switched-capacitor circuits, energy harvesting, co-design, positive feedback, sciatic nerve stimulation, rat experiments
- MeSH terms
- Animals, Electric Stimulation, Electrodes, Electromyography, Equipment Design, Electric Power Supplies, Sciatic Nerve, Rats, Sprague-Dawley, Prostheses and Implants, Rats, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.