In this work, a switched-capacitor-based stimulator circuit that enables efficient energy harvesting for neurostimulation applications is presented, followed by the discussion on the optimization of the inductive coupling front-end through a codesign approach. The stimulator salvages input energy and stores it in a storage capacitor, and, when the voltage reaches a threshold, releases the energy as an output stimulus. The dynamics of the circuit are automatically enabled by a positive feedback, eliminating any stimulation control circuit blocks. The IC is fabricated in a 180 nm CMOS process and achieves a quiescent current consumption of 1.8 μA. The inductive coupling front-end is optimized as a loaded resonator, in which the input impedance of the custom rectifier directly loads the inductive loop antenna. The loaded quality factor and the rectifier's efficiency determine the reception sensitivity of the stimulator, while a balance should be achieved for the robustness of the system against dielectric medium variations by increasing the reception bandwidth. The finalized stimulator adopts a 4.9 mm × 4.9 mm inductive loop antenna and achieves an overall assembly dimension of 5 mm × 7.5 mm. Operating at the resonant frequency of 198 MHz, the stimulator works at a 14 cm distance from the transmitter in the air. An animal experiment was performed, in which a fully implanted stimulator excited the sciatic nerve of a rat that consequently triggered the movement of the limb.

Overview

Integrity signals

Registry

Crossref · 10.1109/tbcas.2018.2852680

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 47

Metadata

Authors
Lyu, H., Wang, J., La, J.-H., Chung, J. M., & Babakhani, A.
Affiliations
  • Rice University (US)
  • The University of Texas Medical Branch at Galveston (US)
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2018-10
Volume
12
Issue
5
Pages
1131-1143
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2886324498
Cited by
47
References
44
Citations by year
2026: 4 · 2025: 2 · 2024: 5 · 2023: 5 · 2022: 6 · 2021: 7 · 2020: 9 · 2019: 7 · 2018: 2
FWCI
2.39
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Science Foundation
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
implantable neurostimulator, wireless power transfer, inductive coupling, rectifier, switched-capacitor circuits, energy harvesting, co-design, positive feedback, sciatic nerve stimulation, rat experiments
MeSH terms
Animals, Electric Stimulation, Electrodes, Electromyography, Equipment Design, Electric Power Supplies, Sciatic Nerve, Rats, Sprague-Dawley, Prostheses and Implants, Rats, Wireless Technology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.