Open-Transistor Fault Diagnostics in Voltage-Source Inverters by Analyzing the Load Currents
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
A novel method is presented for the detection and isolation of open-transistor faults in voltage-source inverters feeding AC motors. The method is an extension of the normalized DC-components method. The normalized average currents are combined with additional diagnostic variables which convey information about the percentage of time spent by the phase currents in the near-zero zone. The combined diagnostic signals permit much more robust diagnostics of single-transistor faults and make feasible the diagnostics of multiple-transistor faults. Suggested in this paper is also an alternative solution for the normalization of DC components, which is easier interpreted and simpler to implement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140 · cited 2×
“By construction, Fault_Certainty(F) ∈ [0, 1 ] with 0 representing the lowest and 1 representing the highest level of”
BackgroundRecent developments of induction motor drives fault diagnosis using AI techniques
Filippetti, F., Franceschini, G., Tassoni, C., & Vas, P. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873207 · Cited by 511
Grubic, S., Aller, J. M., Lu, B., & Habetler, T. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004665 · Cited by 490
Fault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441
Investigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.297920 · Cited by 386
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J.-P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Investigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (2003) · Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1992.244307 · Cited by 370
Zidani, F., Diallo, D., Benbouzid, M. E. H., & Nait-Said, R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911951 · Cited by 335
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629048 · Cited by 304
Fault Diagnostic System for a Multilevel Inverter Using a Neural Network
Khomfoi, S., & Tolbert, L. M. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.897128 · Cited by 291
Cited by
Study and Handling Methods of Power IGBT Module Failures in Power Electronic Converter Systems
Choi, U.-M., Blaabjerg, F., & Lee, K.-B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2373390 · Cited by 700
Trends in Fault Diagnosis for Electrical Machines: A Review of Diagnostic Techniques
Henao, H., Capolino, G.-A., Fernandez-Cabanas, M., Filippetti, F., Bruzzese, C., Strangas, E., Pusca, R., Estima, J., Riera-Guasp, M., & Hedayati-Kia, S. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2287651 · Cited by 602
Riera-Guasp, M., Antonino-Daviu, J. A., & Capolino, G.-A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2375853 · Cited by 573
Survey of fault-tolerance techniques for three-phase voltage source inverters
Mirafzal, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301712 · Cited by 440
“) are compared with expected values (thresholds) [2], [3], [16], [17].”
BackgroundEstima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377
“These problems were mitigated by the normalization of the diagnostic variables, as proposed in [20].”
MethodLi, B., Shi, S., Wang, B., Wang, G., Wang, W., & Xu, D. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2454534 · Cited by 329
A New Approach for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Source Inverters
Estima, J. O., & Marques Cardoso, A. J. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168800 · Cited by 298
Jlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284
“shows that they may be classified as current signatures [12]– [20], [22]–[25], [30], [33]–[36] and voltage signatures based methods [26]–[29], [31], [32].”
BackgroundMethodInfluentialOpen-Circuit Fault Diagnosis in PMSG Drives for Wind Turbine Applications
Freire, N. M. A., Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2207655 · Cited by 277
Jung, S.-M., Park, J.-S., Kim, H.-W., Cho, K.-Y., & Youn, M.-J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212916 · Cited by 271
A Failure-Detection Strategy for IGBT Based on Gate-Voltage Behavior Applied to a Motor Drive System
Rodríguez-Blanco, M. A., Claudio-Sánchez, A., Theilliol, D., Vela-Valdés, L. G., Sibaja-Terán, P., Hernández-González, L., & Aguayo-Alquicira, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2098355 · Cited by 264
Model-Based Fault Detection and Identification for Switching Power Converters
Poon, J., Jain, P., Konstantakopoulos, I. C., Spanos, C., Panda, S. K., & Sanders, S. R. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2541342 · Cited by 257
Smet, V., Forest, F., Huselstein, J.-J., Rashed, A., & Richardeau, F. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2196894 · Cited by 232
Jlassi, I., Estima, J. O., Khojet El Khil, S., Mrabet Bellaaj, N., & Marques Cardoso, A. J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2342506 · Cited by 212
“These problems were mitigated by the normalization of the diagnostic variables, as proposed in [21].”
MethodGou, B., Ge, X., Wang, S., Feng, X., Kuo, J. B., & Habetler, T. G. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2465299 · Cited by 191
“Signal-based approaches to detect open-switch fault are classified as current-based [15], [16] and voltage-based [17], [18].”
BackgroundFreire, N. M. A., Estima, J. O., & Cardoso, A. J. M. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2279383 · Cited by 167
“were suggested and refined in [10] and [11].”
BackgroundMethodShu, C., Ya-Ting, C., Tian-Jian, Y., & Xun, W. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2535960 · Cited by 158
“An improved normalized dc-components-based diagnosis method is proposed in [18].”
MethodDiagnosis of Open-Switch and Current Sensor Faults in PMSM Drives Through Stator Current Analysis
Khojet El Khil, S., Jlassi, I., Marques Cardoso, A. J., Estima, J. O., & Mrabet-Bellaaj, N. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2930592 · Cited by 147
“Hence, this approach is usually associated with other algorithms, such as fuzzy logic approach [29], [30] or the motor currents slope variation in the α–β frame [31], to aim both single and multiple inverter fault diagnosis purpose.”
MethodBaudart, F., Dehez, B., Matagne, E., Telteu-Nedelcu, D., Alexandre, P., & Labrique, F. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2170393 · Cited by 98
Wu, F., & Zhao, J. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2587339 · Cited by 82
“Recently, load current analysis method, current sections analysis in dq-coordinate, and symmetry analysis based on allelic points are proposed in [22]–[24], these methods perform well in fault detection for their fair robustness to variable load and speed, as well as effective and accurate fault location.”
MethodTrabelsi, M., Semail, E., & Nguyen, N. K. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2719634 · Cited by 61
“In [23] and [24], for almost sinusoidal five-phase machines, it is shown clearly, as in [22], that the inverter fault induces a fault current component in the second plane instead of a near zero current component under a healthy operation of the VSI.”
Liang, Y., Wang, R., & Hu, B. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3003058 · Cited by 54
“The load currents are utilized in conventional current-based methods, which has been widely applied in two-level inverter systems [14]–[17].”
MethodFaults and Diagnosis Systems in Power Converters
Lee, K.-B., & Choi, U.-M. (2014) · Studies in Computational Intelligence · doi:10.1007/978-3-319-03401-0_4 · Cited by 6
Metadata
- Authors
- Sleszynski, W., Nieznanski, J., & Cichowski, A.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2009-11
- Volume
- 56
- Issue
- 11
- Pages
- 4681-4688
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2156740116
- Cited by
- 300
- References
- 24
- FWCI
- 12.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.